A23-050 Portable Air Filtration Unit Solicitation

Agency: DEPT OF DEFENSE
State: Oklahoma
Type of Government: Federal
Category:
  • 44 - Furnace, Steam Plant, and Drying Equip, Nuclear Reactors
Posted: Jun 1, 2023
Due: Jun 9, 2023
Solicitation No: FA812523Q0072
Publication URL: To access bid details, please log in.
Follow
A23-050 Portable Air Filtration Unit Solicitation
Active
Contract Opportunity
Notice ID
FA812523Q0072
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE AIR FORCE
Major Command
AFMC
Sub Command
AIR FORCE SUSTAINMENT CENTER
Office
FA8125 AFSC PZIMA
Looking for contract opportunity help?

Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.

General Information
  • Contract Opportunity Type: Solicitation (Updated)
  • All Dates/Times are: (UTC-05:00) CENTRAL STANDARD TIME, CHICAGO, USA
  • Updated Published Date: Jun 01, 2023 02:39 pm CDT
  • Original Published Date: May 25, 2023 08:47 am CDT
  • Updated Date Offers Due: Jun 09, 2023 03:00 pm CDT
  • Original Date Offers Due: Jun 06, 2023 03:00 pm CDT
  • Inactive Policy: 15 days after date offers due
  • Updated Inactive Date: Jun 24, 2023
  • Original Inactive Date: Jun 21, 2023
  • Initiative:
    • None
Classification
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: 4460 - AIR PURIFICATION EQUIPMENT
  • NAICS Code:
    • 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
  • Place of Performance:
    Tinker AFB , OK 73145
    USA
Description

The purpose of this amendment is to add the diagram, approved filters list, and extend the solicitation to June 9, 2023.



Portable HEPA Air Filtration Unit

Item Description



The 76th AMXG is requesting the purchase of Portable HEPA Air Filtration Unit. This unit will be used for collection of dust / debris from blasting operations. (i.e. paint / coating removal)



This requirement must have the following specifications:



1. One (1) Portable Air Filtration unit, with the following specifications:



a. Shall have an air filtration system comprised of the following types of filter in sequential order (refer to attached sketch):

i. Automatically purging dust collection filter system

ii. National Emission Standards for Hazardous Air Pollutants (NESHAP) Method 319 compliant 3-stage dry particulate filter system (2 stages of panel filter, and 5-pocket bag filter) tested and certified in accordance with 40 CFR 63.750(o). A list of approved filter systems is attached.

iii. HEPA air filter.



b. Shall have a dust collection filter system (comprised of no fewer than six (6) cartridge filters of dimensions no smaller than 12.75" x 30" and efficiency no lower than 99.9% at 0.5 microns) mounted upstream of the NESHAP Method 319 compliant filter system per the attached diagram.



c. Shall have automated compressed air jet pulsation filter cleaning system for particulate removal/cleaning of dust collection filters.



d. Shall have compressed air filter cleaning system, Programmable Logic Controller controlled reverse jet pulse.

i. Shall use compressed air of 1.5 SCF/pulse.

ii. Shall have three (3) diaphragm valves.

iii. Shall have three (3) pilot valves.



e. Shall have IEC/NEMA-sized combination start/stop motor starter.

i. Starter is to be 208VAC/240VAC, 3 phase, with portable cord.

ii. Cord is to have four (4) conductors, have 10 AWG wire size, be rubber, be black, be 100 ft long, and be 600V SOOW.

f. Shall have analog differential pressure measurement across all three (3) stages of NESHAP Method 319 compliant filter.

i. Shall have ability to establish a set point to measure a pressure drop of up to one (1) inch of water column across the three (3) stages of filters (both panels and bag).

ii. Gauge shall have a span of at least three (3) inches of water.



g. Shall have HEPA after filters, 99.97% efficiency rating. 24" x 24" x 12" (nominal).

h. Each HEPA filter must be metal encased with rubber or neoprene gasket.

i. Shall include four (4) extra sets of all stages of filters

j. Shall have Minimum Air Flow of 4,000 CFM.

k. Shall have Minimum of 5 HP, 3 Phase, 1750 RPM, TEFC Motor with non-overloading blower with overload protection

l. Shall have voltage requirements of 208/230V (with L15-30 Amp, 4 Prong Locking Male Plug).

m. Shall have 100’ power cord

n. Shall have tow bar with lunette of toroidal steel construction.

o. Shall have epoxy coating (or equivalent protective coating)

p. Dimensional Requirements:

i. Shall have Maximum Height of 4-1/2 feet

ii. Shall have a Maximum Length of 10 feet (not including tow bar).

iii. Shall have a Maximum Width of 6 feet



q. Shall provide copy of schematic drawings and design specifications for approval prior to shipment.

r. Shall have two duct flanges capable of connecting to standard 12" ID flexible reinforced duct on the dust-collecting side of the unit.



s. Must ship with quantity four (4) of 25’ sections of flexible, reinforced, collapsible dust collection suction hose.

i. Shall include two (2) connectors, each of which can connect quantity two (2) of 25’ sections together.

ii. Hoses shall be compatible with duct flanges installed on the dust-collecting side of the unit.



t. Shall have welded, heavy gauge, carbon steel construction.



u. Shall have minimum four (4) heavy duty, industrial grade casters.





v. Casters on the towbar side shall swivel and casters opposite the towbar shall be rigid. All Casters shall:

i. have shock absorbers

ii. have wheels of solid material (i.e. rubber versus air filled)

iii. have wheels no smaller than 6” diameter

iv. be suitable for towing on rough surfaces

v. be lockable

vi. be suitable for being towed

vii. be rated for outdoor use

viii. be heavy duty.



w. Shall have multipurpose epoxy coating throughout collector.

x. Shall include One (1) Manual in PDF format, to be transmitted electronically.



2. Contractor shall furnish NESHAP Method 319 Filter System certification at time of bid submission. Method 319 certified filters shall comply with the filter efficiencies in Table 4 (liquid) and 5 (solid) of 40 CFR 63.745.



3. Contractor shall provide documentation certifying that HEPA Air Filtration Unit provided is NESHAP Method 319 compliant per 40 CFR 63.745 and 40 CFR 63.746 by date of unit shipment.


Attachments/Links
Contact Information
Contracting Office Address
  • CP 405 734 9107 3001 STAFF DR STE 2S76
  • TINKER AFB , OK 73145-3303
  • USA
Primary Point of Contact
Secondary Point of Contact
History

Related Document

Apr 27, 2023[Sources Sought (Original)] FA812523Q0072 - A23-050 Portable Air filtration unit Synopsis
May 25, 2023[Solicitation (Original)] A23-050 Portable Air Filtration Unit Solicitation
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...Follow Chemical Cleaning Systems Active Contract Opportunity Notice ID FA813224QCCS1 Related... MATERIEL COMMAND ...

Federal Agency

Bid Due: 4/12/2024

...SERVICES, DEPARTMENT OF Sub-tier INDIAN HEALTH SERVICE Office OK CITY AREA INDIAN HEALTH ...

HEALTH AND HUMAN SERVICES, DEPARTMENT OF

Bid Due: 4/05/2024

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only as a convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.