STATE OF NORTH CAROLINA
DEPARTMENT OF TRANSPORTATION
JOSH STEIN
GOVERNOR
DANIEL H. JOHNSON
SECRETARY
July 8, 2026
ADDENDUM # 1
Contract Number: DN01166
TIP Number:
N/A
Federal Aid Number: Helene
WBS Number:
DF18314.2045332
County:
Henderson
Description:
Grading, Drainage, Paving, And Structure At Bridge 440055 Over
Hungry River On SR 1802 (Big Hungry Road) in Henderson
County
Letting Date:
July 14, 2026
Plan Holders
Content Summary: Provision Changes & Plans Changes
The above contract has experienced the following revisions:
1. Replace the Structures Project Special Provisions with the attached
2. Replace sheet S-4 with the attached
These revisions do not change bid items or the associated quantities.
There is no ebsx addenda file associated with this addendum.
Thank you for your attention to this matter.
If you have any questions, please contact the Division Proposal Engineer at (828) 331-
5200.
Sincerely,
Mailing Address:
NC DEPARTMENT OF TRANSPORTATION
DIVISION OF HIGHWAYS - DIVISION 14
253 WEBSTER ROAD
SYLVA, NC 28779
Jeanette L. White, P.E.
Highway Division 14, Project Development-
Team Lead
Telephone: (828) 331-5200
Fax: (828) 331-5201
Customer Service: 1-877-368-4968
Location:
253 WEBSTER ROAD
SYLVA, NC 28779
Website: www.ncdot.gov
Docusign Envelope ID: 3BD5BB56-DC4D-868B-82A8-7FCAB901DAC1
DF18314.2045332
ST-1
Henderson County
Project Special Provisions
Structure
Table of Contents
Page #
FALSEWORK AND FORMWORK
(11-30-23) ...……………….ST-2
SUBMITTAL OF WORKING DRAWINGS
(01-31-25) ………..………..ST-8
CRANE SAFETY
(12-05-25) ..………………ST-14
GROUT FOR STRUCTURES
(12-01-17) ….…………….ST-15
ASBESTOS ASSESSMENT
(11-30-23) ………………..ST-16
CORED SLAB AND BOX BEAM
POST TENSIONING
(08-25-25) ………………..ST-19
CONSTRUCTION, MAINTENANCE AND
REMOVAL OF TEMPORARY ACCESS AT
STATION 13+70.81 -L-
(SPECIAL) ………………..ST-20
REMOVAL, STAGING, DEMOLITION AND
CONSTRUCTION OF STRUCTURE AT
STATION 13+70.81 -L-
(SPECIAL) ………………..ST-21
TEMPORARY TIMBER MATS
(SPECIAL) ………………..ST-23
ORTHFECSASRIOONLIN
SEAL
052672
TTHEENWG
INEER
R. ACO
6/29/2026
Docusign Envelope ID: 3BD5BB56-DC4D-868B-82A8-7FCAB901DAC1
DF18314.2045332
ST-2
Henderson County
FALSEWORK AND FORMWORK
(11-30-23)
GENERAL
Use this Special Provision as a guide to develop temporary works submittals required by the
Standard Specifications or other provisions; no additional submittals are required herein. Such
temporary works include, but are not limited to, falsework and formwork.
Falsework is any temporary construction used to support the permanent structure until it becomes
self-supporting. Formwork is the temporary structure or mold used to retain plastic or fluid
concrete in its designated shape until it hardens. Access scaffolding is a temporary structure that
functions as a work platform that supports construction personnel, materials, and tools, but is not
intended to support the structure. Scaffolding systems that are used to temporarily support
permanent structures (as opposed to functioning as work platforms) are considered to be falsework
under the definitions given. Shoring is a component of falsework such as horizontal, vertical, or
inclined support members. Where the term “temporary works” is used, it includes all of the
temporary facilities used in bridge construction that do not become part of the permanent structure.
Design and construct safe and adequate temporary works that will support all loads imposed and
provide the necessary rigidity to achieve the lines and grades shown on the plans in the final
structure.
MATERIALS
Select materials suitable for temporary works; however, select materials that also ensure the safety
and quality required by the design assumptions. The Engineer has authority to reject material on
the basis of its condition, inappropriate use, safety, or nonconformance with the plans. Clearly
identify allowable loads or stresses for all materials or manufactured devices on the plans. Revise
the plan and notify the Engineer if any change to materials or material strengths is required.
DESIGN REQUIREMENTS
(A) Working Drawings
Provide working drawings for items as specified in the contract, or as required by the Engineer,
with design calculations and supporting data in sufficient detail to permit a structural and safety
review of the proposed design of the temporary work.
On the drawings, show all information necessary to allow the design of any component to be
checked independently as determined by the Engineer.
When concrete placement is involved, include data such as the drawings of proposed sequence,
rate of placement, direction of placement, and location of all construction joints.
When required, have the drawings and calculations prepared under the guidance of, and sealed
by, a North Carolina Registered Professional Engineer who is knowledgeable in temporary
works design.
Docusign Envelope ID: 3BD5BB56-DC4D-868B-82A8-7FCAB901DAC1
DF18314.2045332
ST-3
Henderson County
If requested by the Engineer, submit with the working drawings manufacturer’s catalog data
listing the weight of all construction equipment that will be supported on the temporary work.
Show anticipated total settlements and/or deflections of falsework and forms on the working
drawings. Include falsework footing settlements, joint take-up, and deflection of beams or
girders.
As an option for the Contractor, overhang falsework hangers may be uniformly spaced, at a
maximum of 36 inches, provided the following conditions are met:
Member Member Max. Overhang Max. Slab Edge Max. Screed
Type Depth,
Width,
Thickness, Wheel Weight,
(PCG) (inches)
(inches)
(inches)
(lbs.)
II
36
39
III
45
42
IV
54
45
MBT
63
51
MBT
72
55
14
2000
14
2000
14
2000
12
2000
12
1700
Bracket Min.
Vertical Leg
Extension,
(inches)
26
35
44
50
48
Overhang width is measured from the centerline of the girder to the edge of the deck slab. For
Type II, III & IV prestressed concrete girders (PCG), 45-degree cast-in-place half hangers and
rods must have a minimum safe working load of 6,000 lbs.
For MBT prestressed concrete girders, 45-degree angle holes for falsework hanger rods shall
be cast through the girder top flange and located, measuring along the top of the member, 1’-
2 ½” from the edge of the top flange. Hanger hardware and rods must have a minimum safe
working load of 6,000 lbs.
For link slabs, the top of girders directly beneath the link slab shall be free of overhang
falsework attachments or other hardware. Submit calculations and working drawings for
overhang falsework in the link slab region.
The overhang bracket provided for the diagonal leg shall have a minimum safe working load
of 3,750 lbs. The vertical leg of the bracket shall extend to the point that the heel bears on the
girder bottom flange, no closer than 4 inches from the bottom of the member. However, for
72-inch members, the heel of the bracket shall bear on the web, near the bottom flange
transition.
Provide adequate overhang falsework and determine the appropriate adjustments for deck
geometry, equipment, casting procedures and casting conditions.
If the optional overhang falsework spacing is used, indicate this on the falsework submittal and
advise the girder producer of the proposed details. Failure to notify the Engineer of hanger type
and hanger spacing on prestressed concrete girder casting drawings may delay the approval of
those drawings.
Docusign Envelope ID: 3BD5BB56-DC4D-868B-82A8-7FCAB901DAC1
DF18314.2045332
ST-4
Henderson County
Falsework hangers that support concentrated loads and are installed at the edge of thin top
flange concrete girders (such as bulb tee girders) shall be spaced so as not to exceed 75% of
the manufacturer’s stated safe working load. Use of dual leg hangers (such as Meadow Burke
HF-42 and HF-43) are not allowed on concrete girders with thin top flanges. Design the
falsework and forms supporting deck slabs and overhangs on girder bridges so that there will
be no differential settlement between the girders and the deck forms during placement of deck
concrete.
When staged construction of the bridge deck is required, detail falsework and forms for screed
and fluid concrete loads to be independent of any previous deck pour components when the
mid-span girder deflection due to deck weight is greater than ¾”.
Note on the working drawings any anchorages, connectors, inserts, steel sleeves or other such
devices used as part of the falsework or formwork that remains in the permanent structure. If
the plan notes indicate that the structure contains the necessary corrosion protection required
for a Corrosive Site, epoxy coat, galvanize or metalize these devices. Electroplating will not
be allowed. Any coating required by the Engineer will be considered incidental to the various
pay items requiring temporary works.
Design falsework and formwork requiring submittals in accordance with the current edition of
AASHTO Guide Design Specifications for Bridge Temporary Works except as noted herein.
(1) Wind Loads
Table 2.2 of Article 2.2.5.1 is modified to include wind velocities up to 110 mph. In
addition, Table 2.2A is included to provide the maximum wind speeds by county in North
Carolina.
Table 2.2 - Wind Pressure Values
Height Zone
Pressure, lb/ft2 for Indicated Wind Velocity, mph
feet above ground
70
80
90
100
110
0 to 30
15
20
25
30
35
30 to 50
20
25
30
35
40
50 to 100
25
30
35
40
45
over 100
30
35
40
45
50
(2) Time of Removal
The following requirements replace those of Article 3.4.8.2.
Do not remove forms until the concrete has attained strengths required in Article 420-16
of the Standard Specifications and these Special Provisions.
Do not remove forms until the concrete has sufficient strength to prevent surface damage.