Quaestor 8000 Standard
| Location: |
Missouri |
| Posted: |
Jun 3, 2025 |
| Due: |
Jun 12, 2025 |
| Agency: |
DEPT OF DEFENSE |
| Type of Government: |
Federal |
| Category: |
- 42 - Fire Fighting, Rescue, and Safety Equipment
|
| Solicitation No: |
W911S225U0848 |
| Publication URL: |
To access bid details, please log in. |
Quaestor 8000 Standard
Active
Contract Opportunity
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE ARMY
Major Command
AMC
Sub Command
ACC
Sub Command 2
MISSION INSTALLATION CONTRACTING COMMAND
Sub Command 3
419TH CSB
Office
W6QM MICC-FT DRUM
Looking for contract opportunity help?
General Information
-
Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
-
Original Published Date: Jun 03, 2025 07:14 am CDT
-
Original Date Offers Due: Jun 12, 2025 04:00 pm CDT
-
Inactive Policy: Manual
-
Original Inactive Date:
Jun 03, 2026
-
Initiative:
Classification
Description
Salient Characteristics:001: Quaestor 8000 Standard: (R63260) Must be able to test Drager PSS 7000SCBA?s and Drager Pas-Colt Escape paks Must be a fully automatic test instrument for thetesting of full-face masks, compressed air breathing apparatus and closed-circuit breathingapparatus Must have training on new equipment provided by seller Must have an externalmicrophone Must have a gauge holder Must have a low-pressure measuring point Musthave a test head with gel face Must have a storage area for components Must have a CPSfilling connection Must have a medium pressure extractable inlet and a rotatable outletMust have a high-pressure inlet and outlet Must have a breathing volume of at least 134L/min The breathing frequency of the artificial lung must be at least 5 to 38 strokes a min.Must have a pressure sensor accuracy less than 1 according to DIN EN 837 Must havepermitted air pressure no less than 22 inHg and no more than 36 inHg Must weigh at least45 lbs. Must have a permitted low storage temperature of -20F and a permitted high storagetemperature of 136F Must have a high-pressure range of at least 350 bar Must have amedium pressure range of at least 25 bar Must have a low-pressure range of at least -40 to+30 mbar Must have adapters for 4500 psi systems and adapters for 3000 psi escapedevices Must have a connection for external microphone and external microphone must beprovided Must have a 24V power adapter for 110/230V power supply.002: Case Quaestor (3712635)003: Set Q6/8k bypass relief valve (3731941)004: Bar module, Spare set 200 bar module with output. (R58367)005: Quaestor 8000 Training
Attachments/Links
Contact Information
Contracting Office Address
-
MICC FORT DRUM 4205 PO VALLEY RD
-
FORT DRUM , NY 13602-5220
-
USA
Secondary Point of Contact
History
-
Jun 03, 2025 07:14 am CDTCombined Synopsis/Solicitation (Original)
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.