4120--36C242-24-AP-3358|528-25-4-4895-0087| Buffalo VA Room 61 Air Handler & Condenser
| Location: |
New York |
| Posted: |
Jun 16, 2025 |
| Due: |
Jun 23, 2025 |
| Agency: |
VETERANS AFFAIRS, DEPARTMENT OF |
| Type of Government: |
Federal |
| Category: |
- 41 - Refrigeration, Air Conditioning and Air Circulating Equip.
|
| Solicitation No: |
36C24225Q0741 |
| Publication URL: |
To access bid details, please log in. |
4120--36C242-24-AP-3358|528-25-4-4895-0087| Buffalo VA Room 61 Air Handler & Condenser
Active
Contract Opportunity
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
242-NETWORK CONTRACT OFFICE 02 (36C242)
Looking for contract opportunity help?
General Information
-
Contract Opportunity Type: Sources Sought (Original)
-
Original Published Date: Jun 16, 2025 02:26 pm EDT
-
Original Response Date: Jun 23, 2025 04:00 pm EDT
-
Inactive Policy: Manual
-
Original Inactive Date:
Sep 30, 2025
-
Initiative:
Classification
Description
SUMMARY:
The Veterans Affairs Western New York (VAWNY) Healthcare Facility located at 3495 Bailey Avenue Buffalo, New York, 14215 is seeking a one-time supply contract to purchase a new condensing and air handling unit for Building Six (6), Room Sixty-One (61).
SPECIFIC TASKS:
Supply one (1) Ten (10) ton condensing unit, air handler, and associated materials that matches the specifications provided within this statement of work (SOW).
GENERAL SPECIFICTIONS:
Per ASHRAE 62.1 recommendation, indoor air handling units will be stretch or shrink wrapped to protect unit from in-transit rain and debris.
Units shall be UL and C-UL Listed.
UNIT SPECIFICATIONS:
The condensing unit shall meet the following specifications:
Cooling Capacity: 117,000 BTUH
Cooling Efficiency: 11.2 EER
Maximum Fuse / Breaker Size: 60 Amps
MCA: 40.6 Amps
Nominal Tons: 10
Number of Circuits: 1
Refrigerant: R410A
Sound Rating: 83 Decibels
Voltage:208-240 / 3 phase
An example of a condensing unit that meets these specifications is Arcoaire CAS121HAA0A00A.
The air handling unit shall meet the following specifications:
2 Stage.
Direct-Expansion Coil Face Area: 10.01 Sq/Ft.
Fans Airflow Range: 3,000-5,000 CFM.
Fans Nominal Airflow: 4,000 CFM.
Fans Nominal Motor: 2.4 Horsepower.
Maximum Fuse / Breaker Size: 15 Amps.
MCA: 7.3/3.3 Amps.
Nominal Tons: 10.
Number of Circuits: 2.
Operating Weight (Lbs.): 425.
Sound Rating: 91.6 Decibels.
Voltage: 208-240/3 phase 460/3 Phase.
This will be a horizontal suspended unit that requires side panel access.
Ability to have a rear return to connect to the preexisting economizer.
Direct drive.
If no stub-outs for coil connections are present on the unit, the vendor shall provide supporting fittings that is required for connection.
An example of air handling unit that meets these specifications is Arcoaire FAX120MAAA0A0A.
The line-set and associated connections shall meet the following specifications:
A minimum of forty (40) feet of ACR tubing.
A minimum of forty (40) feet of ACR hard drawn tubing for suction.
Twelve (12) long radius ninety (90) degree fittings.
Two (2) T-fittings for 2-stage AHU.
1/2-inch wall Armacell Armaflex Insulation to include 1 pint of Armaflex 520 adhesive.
Two (2) Sight glasses with brazed connection.
Two (2) Filter driers with brazed connection.
If another unit that meets the above specifications is provided ensure all line sizing is provided accordingly.
DELIVERY SCHEDULE:
The successful bidder shall deliver all goods purchased under this contract to 3495 Bailey Avenue, Buffalo, NY 14215 within thirty (30) days of receiving the signed purchase order issued from the Contracting Officer (CO).
VA INSPECTION AND ACCEPTANCE CRITERIA:
Upon delivery of condensing and air handling units, the COR or designee will verify that the equipment satisfies this requirement, is complete, and free of defects and/or damage.
The vendor shall be notified within 3 duty days of receipt of unacceptable materials. The contractor shall deliver replacement materials within thirty (30) business days of notification of unacceptable materials.
QUALITY ASSURANCE:
The vendor shall provide a one (1) year warranty on all parts and labor associated with repairs of the air handling and condensing units purchased under this contract.
Attachments/Links
Contact Information
Contracting Office Address
-
113 HOLLAND AVE
-
ALBANY , NY 12208
-
USA
Secondary Point of Contact
History
-
Jun 16, 2025 02:26 pm EDTSources Sought (Original)
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
See also
...Classification Original Set Aside: Product Service Code: 4420 - HEAT EXCHANGERS AND STEAM ...
DEPT OF DEFENSE
Bid Due: 7/10/2026
...(10 units - Daikin RLP350BA, 12-Ton VRV Outdoor MegaQ Condensers; 10 units - ...
The City of New York
Bid Due: 7/02/2026
...condenser to CGC WALNUT (WLB-205) Item Description QTY QUINCY - 340 Reciprocating Air ...
HOMELAND SECURITY, DEPARTMENT OF
Bid Due: 6/08/2026
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.