Water Cooled X-Ray System
| Location: |
Oklahoma |
| Posted: |
May 29, 2025 |
| Due: |
Jun 4, 2025 |
| Agency: |
DEPT OF DEFENSE |
| Type of Government: |
Federal |
| Category: |
- 66 - Instruments and Laboratory Equipment
|
| Solicitation No: |
A24-007 |
| Publication URL: |
To access bid details, please log in. |
Water Cooled X-Ray System
Active
Contract Opportunity
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE AIR FORCE
Major Command
AIR FORCE MATERIEL COMMAND
Sub Command
AIR FORCE SUSTAINMENT CENTER
Office
FA8125 AFSC PZIMA
Looking for contract opportunity help?
General Information
-
Contract Opportunity Type: Presolicitation (Original)
-
Original Published Date: May 29, 2025 03:46 pm CDT
-
Original Response Date: Jun 04, 2025 10:00 am CDT
-
Inactive Policy: 15 days after response date
-
Original Inactive Date:
Jun 19, 2025
-
Initiative:
Classification
-
Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
-
Product Service Code: 6680 - LIQUID AND GAS FLOW, LIQUID LEVEL, AND MECHANICAL MOTION MEASURING INSTRUMENTS
-
NAICS Code:
-
334519 - Other Measuring and Controlling Device Manufacturing
-
Place of Performance:
Tinker AFB
,
OK
73145
USA
Description
The Air Force intends to solicit the following supply:
76 AMXG is requesting utilization of funds for Request for the purchase of 4 ea.
Water Cooled Xray System to include the following:
Input Line Requirements:
-
Automatically adapts to input line voltage100-130Vac, 50/60Hz, 20 Amperes maximum.
-
200-250Vac, 50/60Hz, 10 Amperes maximum
-
20 to 160kV, 0.5mA to 5.0mA (800 watts max.)
-
Constant potential, end-grounded anode, liquid cooled version
X-Ray Tube Window:
-
Beryllium 0.8mm (directional) 40° directional
Radiation Output:
-
14R/min at 50cm filtered with 0.5 inches (12.7mm)
-
Aluminum at 160kV, 5mA
Radiation Leakage:
-
Less than 2.0 Roentgens per hour at 1 meter from the X-Raytube target
-
Effective Focal Spot: Standard: 0.7mm x 1.0mm (0.03in x 0.04in) EN125430.5mm x 0.5mm (0.02in x 0.02in) nominal IEC60336
Ambient Temp:
-
100% duty cycle @ 120°F (49°C)
Storage Temp:
-
-30°F to 160°F (-35°C to 71°C)
Anode Cooling:
-
Liquid coolant solution closed loop between X-Ray tube anode and cooling unit.
-
Liquid Cooling Unit Weight: 54lbs. (15.4kg) approx.
-
Tube Head Dimensions: No greater than 7.25" Diameter, 30" Length
-
Liquid Cooled: 29lbs. (13.15kg)
X-Ray Control Unit:
-
X-Ray Control Unit Weight: 26lbs. (11.8kg) approx
Safety Devices:
-
Tubehead Pressure Relief Valve
-
Tubehead Thermal Cut-Out
-
Tubehead Pressure Gauge
-
Tubehead Low Pressure Cut-Out @ 25psi (1.72 Bar)
-
Coolant Flow Sensor (liquid cooled only)
-
Control Unit Safety Keyswitch
-
Microcomputer-based Self Diagnostics
-
Continuous Exposure Parameter Display
Standard Accessories:
-
Operation manual
-
Tubehead carrying case
-
Tubehead Cable- 100’ with strain relief
-
Extra key (1) for Control Unit Safety Lock
-
Power cable - 25’ with strain relief
-
Coolant hose - twin, 50’ with self-sealing terminations
-
(liquid cooled only)
-
Cooler power cable
-
GUI Control Software for the GUI is specifically designed for controlling series systems. As an alternative to the front panel control, the GUI will allow the user to control all necessary functions of the system from a user-friendly windows-based menu. Additionally, the GUI can be used as a diagnostic tool when the system is controlled via the front panel.
A Firm Fixed Price type contract is contemplated.
Estimated Period of Performance: 360 days ARO
This is a small business set-aside
System for Award Management (SAM) is required to receive any award. Contractors can register electronically at https://www.sam.gov/portal/public/SAM/. The NAICS code for this requirement is 334519 with a size standard of 600 EMP.
Interested persons may identify their interest and capability to respond to the requirement by submitting a proposal. Electronic procedures will be used for this solicitation through Beta.sam.gov at https://sam.gov/content/home. No telephone requests. See Note 22. Authority is 10 USC 2304 (c)(1).
For further information contact:
Sondra Groth
Contracting Specialist
Sondra.groth@us.af.mil
Attachments/Links
Contact Information
Contracting Office Address
-
CP 405 734 9107 3001 STAFF DR STE 2S76
-
TINKER AFB , OK 73145-3303
-
USA
Secondary Point of Contact
History
-
May 29, 2025 03:46 pm CDTPresolicitation (Original)
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.