| Location: | New York |
|---|---|
| Posted: | May 2, 2025 |
| Due: | May 29, 2025 |
| Agency: | The New York State Contract Reporter |
| Type of Government: | State & Local |
| Category: |
|
| Publication URL: | To access bid details, please log in. |
Description: Genesys Engineering, P.C. (Genesys), as agent for the Dormitory Authority State of New York (DASNY), is seeking qualifications information from firms that would like to participate in a future Bid Solicitation, as the Prime Contractor, for the construction of a project that involves Chiller Plant and Distribution System Upgrades at Queens College. All interested contractors shall submit a Statement of Qualification and NYS Vendor Responsibility Questionnaire ("VRQ"). Information submitted will be evaluated in order to develop a list of pre-Qualified Bidders for the subject Energy Project that Genesys intends to solicit construction bids for in the second quarter of 2025. A short list of three (3) to five (5) firms will be developed. This short list of Pre-Qualified Bidders will receive the Bid Solicitation. For this project, the successful low bidder, as a condition of being awarded the construction contract, must submit and have approved a project specific Utilization Plan for MBE, WBE and SDVOB Subcontractors in accordance with the goals that will be included in the Bid Documents and must execute a Project Labor Agreement (PLA) that will be included in the Bid Documents. The list of Pre-Qualified Bidders will be selected by Genesys and will be approved by DASNY. The minimum experience level required is as follows:
General Project Description: The anticipated scope of work for the project includes the following: CCNY Marshak Science Hall HVAC System Modifications, Post Kathabar The intent of this project is to upgrade the existing rooftop fresh air handling units following the decommissioning of the Kathabar system. The upgrade will involve adding new sections to the existing custom air handlers, thereby increasing their cooling capacities to meet the cooling and dehumidification demands of the science building. No upsizing of the heating coils will be required for AHUs-1&2, 5&6, and 7&8, as the existing coils are sufficient to maintain the required supply air temperatures under all anticipated operating conditions.
In addition to the above, all projects include ancillary trade work, including general construction, HVAC, electrical, etc. The estimated construction cost range is $5 to $10 Million. Statement of Qualifications The Statement of Qualifications shall include, at a minimum, a Transmittal Letter and the information requested in the below listed TABS, organized in the same manner. Transmittal Letter: In the Transmittal Letter, please indicate the contact information for the individual at your firm who will be receiving communications regarding the bidding of the project (Name, address, phone and fax numbers, and email address). TAB 1: Firm Background The information in this TAB shall include general information on the company background, TAB 2: Relevant DASNY Experience The information in this TAB shall include a list of DASNY projects (minimum of (5) projects and maximum ten (10) projects) where the firm was, or is, the prime contractor. For each of the contracts, provide the following information: 1) Project name; 2) Project location; 3) All project trades (under the prime contract); 4) Firm’s project role; 5) Trade(s) self performed; 6) Dollar value of Prime Contract; 7) Dollar value of all change orders; 8) Year construction completed; 9) DASNY Reference with contact information; and 10) Owner Reference with contact information. TAB 3: Relevant Project Experience The information in this TAB shall include a list of projects (minimum five (5) projects and maximum ten (10) projects) that clearly demonstrate relevant experience with multi-discipline projects for the replacement of the HVAC Infrastructure for major facilities, for which the firm has been the Prime Contractor. At least one (3) project shall be in excess of $25 Million. Experience in operating, educational facilities preferred. For each of the projects, provide the following information: 1) Project name; 2) Project location; 3) All project trades (under the prime contract); 4) Firm’s project role; 5) Trade(s) self performed; 6) Dollar value of Prime Contract; 7) Dollar value of all change orders; 8) Year construction completed; 9) DASNY Reference with contact information; and 10) Owner Reference with contact information. TAB 4: NYS Vendor Responsibility Questionnaire ("VRQ") RESPONSES ARE DUE NO LATER THAN May 29, 2025. Please submit four (4) sets of your Statement of Qualifications to: Genesys Engineering, P.C., 629 Fifth Avenue, Building 3, Pelham, New York 10803, Attention: Gina Tomero, Assistant Project Manager. Due Date: 05/29/2025 2:00 PMContract Term: Twelve (12) months Location: 181 Convent Avenue, New York, New York 10031 Ad Type: General
|

With GovernmentContracts, you can:
...and Water Service: Decommission existing wells and install new domestic water service laterals... ...
HOMELAND SECURITY, DEPARTMENT OF
Bid Due: 6/30/2026