Addendum No. 2 ? John Furbee Aquatics Center Pool and Spray Ground Maintenance Service

Location: California
Posted: Nov 4, 2026
Due: Nov 16, 2026
Agency: City of Desert Hot Springs
Type of Government: State & Local
Category:
  • F - Natural Resources and Conservation Services
  • S - Utilities and Training Services
Publication URL: To access bid details, please log in.
Addendum No. 2 – John Furbee Aquatics Center Pool and Spray Ground Maintenance Service Addendum No. 2 - John Furbee Aquatics Center Pool and Spray Ground Maintenance Service
Posted on November 4, 2026
Download

Attachment Preview

CITY OF DESERT HOT SPRINGS
PUBLIC WORKS
11999 Palm Drive * Desert Hot Springs * CA * 92240
ENGI NEERING & OPERATIONS (760) 329-6411* www.cityofdhs.org
ADDENDUM No. 2
JOHN FURBEE AQUATICS CENTER POOL
AND
SPRAY GROUND MAINTENANCE SERVICES
November 4, 2026
The Following is for clarification or changes to the John H Furbee Aquatics Center Pool and Spray Ground
Maintenance Services.
1. CHANGE TO BID DUE DATE
RECEIPT OF BID PROPOSALS: Sealed bid proposals will be received at the Office of the City Clerk, City
Hall, 11999 Palm Drive, Desert Hot Springs, CA 92240, on Thursday, November 16TH , 2026, at 2:00 PM.
2. QUESTIONS AND ANSWERS
The following addresses responses to questions and inquiries received at our office.
3. Bidders are required to use the NEW bid form attached to this addendum as part of their bid
submittal package.
---------------------------------------------------------------------------------------------------------------------------------------------------------
* What is the emergency call out response time required?
Answer: Staff will be required to be onsite within one hour.
* The main pool controller is owned by Eco-Lab. Will the awarded contractor be required to supply
a chemical controller as part of the bid or would you rather have a proposal submitted to install a
new controller that the City would own?
Answer: A new main pool controller must be included in the bid for both purchase and
installation. The City requires an IPS Controller model IPS-M920(ca) or equal (with City approval)
and the City will retain ownership of the controller.
* Should each contract submit an all-inclusive monthly costs proposal including chemicals for 5
days a week, year-round service including holidays and then a separate proposal for 7 days a
week year-round including holidays or do you just want the additional cost if Saturday and
Sunday were to be added?
Answer: Monthly - the cost of chemicals is determined by usage and specific requirements. A
proposal should be submitted outlining the services available seven days a week to address
emergencies. Additionally, monthly services will be necessary for five days each week.
* Splashpad chiller: Please confirm whether annual preventative maintenance of the splashpad

chiller is included in this contract. If so, please provide the manufacturer, model, and required
maintenance scope.
Answer: Complete cleaning of chiller and condenser coils. Set The Delta T.
* Chemical feed pumps: Please confirm whether the existing chemical feed pumps will remain in
service or be replaced under a separate bid. If replacement is planned, please provide the
anticipated completion date and confirm our maintenance and repair responsibilities before
and after replacement.
Answer: A new chemical feed pump must be purchased and installed within 72 hours following
the removal of the existing feed pump.
* ECOLAB controllers: Please confirm whether the existing ECOLAB controllers will remain in service
or be replaced under a separate bid. Please identify any services that must continue to be
performed by ECOLAB or an authorized provider, including responsibility for those costs.
Answer: After vendor is selected, Ecolab will no longer be of service, and they will be required to
remove their controllers. IPS Controller model IPS-M920(ca) will need to be purchased for the City
and installed by the newly selected vendor within a timely manner. This cost will need to be
included in the corresponding line item on the bid form.
* Five-day service and vacuuming: Please confirm that routine service is required five days per
week, Monday through Friday, for both the pool and splashpad. Please specify the required
vacuuming frequency and whether service must be completed before the facility opens at 7:00
a.m.
Answer: Services are for five days a week for the pool and splash pad. During summer season
(May 23 to August 29) services must be completed before 6:30 am. For winter season (August 30
to May 22) services must be completed before 7:00 am.
* Operating calendar: Please provide the annual operating calendar for the pool and splashpad,
including seasonal closures and holidays. Please confirm the service frequency required during
closures and whether the monthly maintenance fee remains consistent throughout the year.
Answer: Operating calendar days are January - September. Regular services will remain
throughout the year. Emergency responses will need to be available on holidays and weekends.
* Equipment inventory and condition: Please provide the equipment list referenced in Part III,
including quantities, manufacturers, models, and available maintenance records. Please identify
known deficiencies and equipment scheduled for repair or replacement before the contract
begins.
Answer: No list available.
* Included maintenance versus extra work: Exhibit A includes broad maintenance and repair
responsibilities, while the Extra Work section allows separate time-and-materials billing. Please
identify which repairs, replacement parts, and consumables must be included in the base fee
and which may be quoted separately.
Answer: Maintenance will include filter care, pump/skimmer baskets, chemical care, pool
vac/skim, heater service, chiller service, minor leaks and inspections.
Extra work- pumps, motors, valve replacement, large leaks, VFD, capacitors, electrical issues and
auto fill valves.

* Scheduled replacement parts: Please confirm whether UV lamps, seal kits, quartz sleeves, heater
filters, chemical pump overhaul kits, tubing, and replacement filter media must be included in the
base monthly service fee. Please provide equipment quantities and the most recent
replacement dates for these items.
Answer: Please see chart in Exhibit A for frequency schedules.
* Maintenance frequencies: Please clarify whether "Bi-Weekly" means twice per week or every two
weeks, and whether "Bi-Annually" means twice per year or every two years.
Answer: Bi-weekly refers to every other week.
Bi-Annually refers to twice per year.
* Chemical pricing and usage: Please confirm whether chemicals should be included in a fixed
contract price or billed separately based on actual quantities delivered or used. Please provide
the past 12-24 months of chemical usage and confirm the estimated annual quantities of 39,000
gallons of chlorine and 4,900 gallons of muriatic acid. Please also identify the required chemical
concentrations and any supplier restrictions.
Answer: Billed separately based on actual quantities delivered or used. Submit unit price per
chemical on bid form. See Exhibit A, Section 16 Chemical Acquisition chart. Use estimated total
units per annual budget estimate.
* Chemical delivery and onsite inventory: For the required onsite stock of wear items, please
identify minimum quantities and whether the City will purchase the initial inventory or the
contractor must include it in the base fee.
Answer: Minimum of 500 gallons of chlorine and 300 liters of acid will need to be onsite. Initial
inventory will need to be provided by vendor.
* Emergency response: Please confirm whether the required one-hour emergency response means
physical arrival onsite or initial acknowledgment and remote assessment. Please clarify how
emergency mitigation is authorized when written approval cannot be obtained before work
begins.
Answer: One-hour emergency response means physical arrival onsite. A verbal through Public
Works staff followed up with a written approval sent to Public Works Supervisor within 72 hours of
verbal approval.
* Seasonal activation and winterization: Please identify which systems require spring activation and
autumn winterization, the anticipated schedule, and whether draining, refilling, startup
chemicals, and permitting support must be included in the base fee.
Answer: The pool does not require seasonal winterization. However, the spray grounds will have
seasonal startups, autumn winterization, chiller and chemicals.
* Cleaning boundaries: Please clarify whether routine cleaning includes the entire pool deck,
splashpad surface, drains, and surrounding walkways, or only debris generated by our
maintenance activities. Please identify any required pressure washing or specialty surface
cleaning.
Answer: City will do routine cleaning. Vendors shall clean up any debris generated by
maintenance activities.

* Contract price adjustments: Please confirm whether annual adjustments are permitted for
prevailing wage increases, chemical costs, or CPI during the initial contract term and optional
extensions. If permitted, please identify the adjustment method and required notice.
Answer: Contract price will remain for 3.5 years without any increases. A Consumer Price Index
(CPI) increase may be considered during the review/approval of each of the two (2) additional
annual contract extensions. The CPI increase may be requested by the vendor and is based on
the County of Riverside's CPI Indexes for corresponding work.
* Would the Raypak high delta annual heater pm include the usual replacement of wear items
such as the 2 ignitors and the 2 flamer sensors. We always assume cleaning of burners/firebox is
part of the annual PMs. These items are not listed at all. We want to be certain we are only to
bid for doing the items from the provided list and then bill separately for other items as they wear
out.
Answer: The bid should include the replacement of two ignitors and two flamer sensors on an
annual basis. Additional cleaning of burners/fireboxes annually is required in the bid. Set The
Delta T.
Thank you,
Alisha Reller
Public Works Management Analyst
Receipt of this addendum shall be submitted with your bid by signing below. YOUR BID WILL BE
DISQUALIFIED IF THIS ADDENDUM NO. 2 IS NOT SIGNED AND SUBMITTED WITH YOUR BID PROPOSAL.
____________________________________________ ____________________
Name (please print) Date
___________________________________________
Signature
BID FORM

ITEM NO. EST. QTY DESCRIPTION UNIT PRICE TOTAL
1 1 Annual Equipment Maintenance Frequency Schedule - Cost Lump Sum
2 1 Annual Daily Water Maintenance Cost - 5 Days Service Year-Round Cost Lump Sum
3 39,000 Gallons of Chlorine Complete in place for the unit price per gallon _______per gallon
4 4,900 Gallons of Muriatic Acid Complete in place for the unit price per gallon _______per gallon
5 4,500 Pounds of Sodium Bicarbonate Complete in place for the unit price per pound _______per lb.
6 5,500 Pounds of Calcium Chloride Complete in place for the unit price per pound _______per lb.
7 1 Pool Controller IPS Controller model IPS- M920(ca - Purchase and Installation _______per controller
8 4 Chemical Feed Pump - Purchase and Installation _______per feed pump
9 2/2 Replacement of 2 burners and 2 ignitors, Purchase and Installation _______per burner _______per ignitor
Grand Total Annual Bid

ITEM EST.
DESCRIPTION UNIT PRICE TOTAL
NO. QTY
Annual Equipment Maintenance Frequency
1 1 Lump Sum
Schedule - Cost
Annual Daily Water Maintenance Cost - 5 Days
2 1 Lump Sum
Service Year-Round Cost
Gallons of Chlorine _______per
3 39,000
Complete in place for the unit price per gallon gallon
Gallons of Muriatic Acid _______per
4 4,900
Complete in place for the unit price per gallon gallon
Pounds of Sodium Bicarbonate _______per
5 4,500
Complete in place for the unit price per pound lb.
Pounds of Calcium Chloride _______per
6 5,500
Complete in place for the unit price per pound lb.
Pool Controller IPS Controller model IPS- _______per
7 1
M920(ca - Purchase and Installation controller
Chemical Feed Pump - Purchase and _______per
8 4
Installation feed pump
_______per
Replacement of 2 burners and 2 ignitors,
burner
9 2/2 Purchase and Installation
_______per
ignitor
Grand Total Annual Bid

This is the opportunity summary page. It provides an overview of this opportunity and a preview of the attached documentation.
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

Follow F108--Contaminated Soil Disposal Active Contract Opportunity Notice ID 36C26227Q0110 Related Notice Department/Ind.

VETERANS AFFAIRS, DEPARTMENT OF

Bid Due: 11/20/2026

EBMUD is soliciting proposals for landscape planning, planting, maintenance, and monitoring services for

East Bay Municipal Utility District

Bid Due: 11/17/2026

Basic Information Title RFP # C26708001: Aquatic Vegetation Control (Reposted) Agency Dept of

State Government of California

Bid Due: 11/24/2026

Project ID: 2026-IFB-MS-0577 Title: TREES FOR PLANTING Addenda: 0 Release Date: 11/3/2026 Due

City of Pasadena

Bid Due: 11/23/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.