| Location: | Georgia |
|---|---|
| Posted: | Oct 13, 2026 |
| Due: | Nov 13, 2026 |
| Agency: | State Government of Georgia |
| Type of Government: | State & Local |
| Category: |
|
| Solicitation No: | PE-66098-NONST-2027-000000152 |
| Publication URL: | To access bid details, please log in. |
| Event ID | Event Title | Government Entity | Start Date (ET) | End Date (ET) |
| PE-66098-NONST-2027-000000152 | Dunwoody Road Gap Fill Sidewalk T6026-2 | Sandy Springs, City Of |
Oct 13, 2026 @ 09:31 AM
|
Nov 13, 2026 @ 02:00 PM
|
Start Date: Oct 13, 2026 @ 09:31 AM ET
End Date:
Nov 13, 2026 @ 02:00 PM ET
The City of Sandy Springs is seeking bids from qualified contractors for the Dunwoody Road Gap Fill Sidewalk Project (T6026-2). The project includes constructing approximately 340 linear feet of six-foot-wide sidewalk with a two-foot landscape strip near Dunwoody Road and Spalding Drive. Additional work includes grading, curb and gutter installation, pavement markings, signage, utility adjustments, erosion control, and traffic management. The project aims to improve pedestrian safety and connectivity by closing the sidewalk gap between Sandy Springs and the City of Dunwoody.
| Code | Description |
| 91327 | Construction, Highway and Road |
| 91350 | Construction, Streets, Major and Residential, Including Reconstruction |
| 91319 | Construction, Curb and Gutter, Including Maintenance, Repair, and Removal Services |
| 91345 | Construction, Sewer and Storm Drain |
| 96861 | Pavement Marking Services, Including Removal of Markings |
| 91347 | Construction, Sidewalk and Driveway, Including Pedestrian and Handicap Ramps |
| 91382 | Maintenance and Repair, Sidewalk and Driveway, Including Removal |
Andre Jefferies
AJefferies@SandySpringsGA.gov
7702061489
| K | ET |
|---|
| DESIGN DATA: N/A SPEED DESIGN: 35 M PH |
|---|
| THIS PROJECT IS 100% IN FULTON COUNTY AND IS 100% IN CONG. DIST. NO. 5. |
city of sandy springs
department of public works
PLAN AND PROFILE OF PROPOSED
PROJECT
LOCATION
PROJECT NO. T6026-2
DESIGN DATA: N/A NOTE :
ALL REFERENCES IN THIS DOCUMENT, WHICH INCLUDES ALL PAPERS,
SPEED DESIGN: 35 MPH WRITINGS, DOCUMENTS, DRAWINGS, OR PHOTOGRAPHS USED, OR TO BE
USED IN CONNECTION WITH THIS DOCUMENT, TO " STATE HIGHWAY
DEPARTMENT OF GEORGIA ", " STATE HIGHWAY DEPARTMENT ", " GEORGIA
STATE HIGHWAY DEPARTMENT ", " HIGHWAY DEPARTMENT ", OR
" DEPARTMENT " WHEN THE CONTEXT THEREOF MEANS THE STATE
HIGHWAY DEPARTMENT OF GEORGIA, AND SHALL BE DEEMED TO MEAN
THE DEPARTMENT OF TRANSPORTATION.
THIS PROJECT IS 100% IN
FULTON COUNTY AND IS
100% IN CONG. DIST. NO. 5.
PROJECT DESIGNATION: EXEMPT
BEGIN CONSTRUCTION
STA 9+89.06
5 . 0 0 S S T P A A L 2 D + I 0 N 1 G . 7 D 0 RIVE
9 + 7 S T D A U N 9 W + O 9 O 2 D . Y 0 2 ROAD
B
O BEGIN PROJECT P
STA 9+75.00 N:1440719.432' 2
E:2241402.068' + 0 0
0 0 +
S69 degrees46'48.4"E
1
0
0
. 0
0 +
1 B O P
P
O
S
L
E
S
I
T
M
4
2
A
9
+
I
degrees
T
2
1
+
O
7'
4
F
5
3
C
5
.7
O
.2
8
N
"
S
W
TRUCTION S75 degrees41'24.1"E
S77 degrees51'04.2"E
S81 degrees43'54.9"E
S84 degrees33'14.9"E
EX ROW (GIS)
E
N
S EN T
:
:
2
1
A D
2
4
P 1
4
4
R 3
1
0
O +
7
6
7 J
9
5
E 5
4
3
C .0
.
.
T
1
0
0
7
8
2
2
'
'
P O
E
1
3 + 7 5
. 0 0
6
5 . 7 8 EX ROW S86 degrees13' (5 5 0 4. ' D 7U R "N I E G W H O T O - D O Y F - R W D AY) S8
S
E 6 N
T
D degrees
A
3 C
1
3 2 O
3
3 ' N
+
01 0 S
4
T 3
1
R .
.9
U 4
6
C " T E ION B PL Y A : NS PREPARED
LP
EX ROW
PLANS COMPLETED
REVISIONS
O A 1 C U T 9 H O M S F 8 I I O E N 3 S 1 R ) R G / 9 P I 9 D R C 8 T 4 I A 8 O H N W . N J E A E E V T H C S E E O T T R R S H T Z Y IZ A I O S C O S N T A N E B E L T M E , D A A E A L O N N T F G D P U E 1 R M 9 O T E 8 H R ( P 4 N G E A ( A N I R N A V A E O D D D R ) TH PP 11 DD II 11 .. DD 66 PP BB BB :: 55 .. .. HH ZZ BB UU OO 11 SS .. 66 II NN 77 PP 00 YY EE 00 AA 77 66 AA DD 00 LL 66 00 NN NN :: 22 DD .. 55 // RR 22 II TT FF EE 00 NN PP PP AA -- 00 GG GG GG SS 11 00 .. .. LL 11 RR 22 II 00 DD 11 11 MM 00 88 AA 55 NN 88 66 EE LENGTH OF PROJECT T P C F U O 6 r L o 0 U T 2 j N O e 6 N T c -2 Y t N No o . . 121
11
P &
8
A
5
U A L N
D
N
U
E
N
D C
W
W O N
O
A F /
O
R E F
D
D R
Y
V V
R
O O
D
L L L L
N
E E
E
FEET PID: 170022000100649
D.B. 56196, PG. 519
THE DATA, TOGETHER WITH ALL OTHER INFORMATION SHOWN ON THESE PLANS OR IN ANYWAY NET LENGTH OF ROADWAY 411 LF P.B. 76, PG. 21
INDICATED THEREBY, WHETHER BY DRAWINGS OR NOTES, OR IN ANY OTHER MANNER, ARE BASED NET LENGTH OF BRIDGES ZONED:RE-1
UPON FIELD INVESTIGATIONS AND ARE BELIEVED TO BE INDICATIVE OF ACTUAL CONDITIONS.
HOWEVER, THE SAME ARE SHOWN AS INFORMATION ONLY, ARE NOT GUARANTEED, AND DO NOT NET LENGTH OF PROJECT
BIND THE DEPARTMENT OF TRANSPORTATION IN ANY WAY. THE ATTENTION OF BIDDER IS NET LENGTH OF EXCEPTIONS
SPECIFICALLY DIRECTED TO SUBSECTIONS 102.04, 102.05, AND 104.03 OF THE SPECIFICATIONS.
GROSS LENGTH OF PROJECT
9/15/2026 GPLOT-ORD DUNWOODY_1 SERIES.dgn SANDY SPRINGS PROJECT NO.
mfrias gplotborder-ORD-PO.tbl CONCOV GEORGIA T6026-2
DUNWOODY
RD
1165 SPALDING DR & 1185 DUNWOODY RD NE
SIDEWALK GAP FILL IMPROVEMENTS
LOCATION SKETCH
EX
ROW
(GIS)
THESE PLANS HAVE BEEN PREPARED IN ACCORDANCE WITH THE CONSTRUCTION
9/16/2026 STANDARDS AND DETAILS BOOK AND ATTACHED APPLICABLE REVISIONS. THE
CONSTRUCTION STANDARDS AND DETAILS BOOK IS AVAILABLE AT:
http://mydocs.dot.ga.gov/info/gdotpubs/ConstructionStandardsAndDetails/Forms/AllItems.aspx
https://library.municode.com/ga/sandy_springs/codes/technical_manuals
EX
ROW
(GIS)
S
C
A
IT
N
Y
D Y
O F
SPRINGS
S
A
T
N
A
Y
N
R
D
E
A
V
R
I
D
SI
S
O
A
N
N
S
D
C O
D
N
ET
T
A
A
I
I
L
N
S
E
B
D
O
W
O
I
K
T H
W
IN
H I
T
C
H
H
I S
T H
PL
E
A
Y
N
R E
SE
V
T
IS
S
E
U
O
P
R
E R
IN
SE
W
D
H
E
I
P
T
C
H
H
E
E
T H
R
C
E
O
R
N
M
E
S
I
T
S
R
I
A
U
T
C
CT
O
I
N
O
F
N
LICT.
APPROVED
PERMITTED BY: ___N____i__c__o___l_e___ _B___r__o___w____n__________ DATE: _ 0 ___ 9 __ / _ 1 __ 8 ___ / _ 2 __ 0 __ 2 ___ 6 __
CITY OF PERMIT #: _ C ___ I _ T ___ Y ___ - _ 2 __ 6 ___ - _ 3 __ 3 _______________________________________________________
CITY LIMITS DUNWOODY T O P H L N U E L M S Y E . B I N P N L O G A E N D F S E F S W O IG R E N T R E W O T R A H E S E V M R IE A T W D H E E A D T N O W T C I O T H H C E O R C M E K S P T P A H E R E C E T S T T T H R O E U C S C I U T T B U Y M R B A I U T L T IL , E D M D I E N P C G L H A A A N N N S D IC W D A E I L T V , H E E T L L E H O C E P T M A R E P IC N PL A T I L C C O A O B R D L E E S
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
SCALE IN FEET O O W RD N I E N R A N A C N E D S T A H N E D O G W E N O E R R G 'S IA A S G T E A N T T E S L . A T W H S IS . PERMIT IS SUBJECT TO ALL SANDY SPRINGS
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR 0 20 40 80 TO THE CONCEALMENT OF WORK.
5901-C Peachtree Dunwoody Rd
Suite 350, Atlanta, GA 30328
EX ROW Tel 678.224.9730 | GFTInc.com
EX
ROW
N/A
411 LF
N/A DRAWING No.
411 LF 01 - 0001
11/05/2020 CONCOV-CE
| mfrias gplotborder-ORD-PO.tbl GEORGIA T6026-2 DRAWING NO. DESCRIPTION REVISION DATE DRAWING NO. DESCRIPTION REVISION DATE 01-0001 COVER 02-0001 INDEX 03-0001 REVISION SUMMARY 04-0001 - 04-0002 GENERAL NOTES 05-0001 TYPICAL SECTIONS 06-0001 SUMMARY OF QUANTITIES 07-0001 QUANTITIES REQUIRED BY AMMENDMENT 08-0001 QUANTITIES REQUIRED BY CONSTRUCTION 13-0001 CONSTRUCTION PLAN 17-0001 DRIVEWAY PROFILES 23-0001 - 23-0002 CROSS SECTIONS 24-000A - 24-0001 UTILITY PLANS 26-0001 SIGNING AND MARKING PLANS 29-0001 - 29-0002 TREE PROTECTION PLAN 38-0001 SPECIAL CONSTRUCTION DETAIL 52-0001 - 52-0007 EROSION CONTROL LEGEND AND UNIFORM CODE SHEET 54-0001 BMP LOCATION DETAILS 56-0001 - 56-0002 EROSION CONTROL DETAILS PERMIT APPROVED PERMITTED BY: ___N____i__c__o___l_e___ _B___r__o___w____n__________ DATE: _ 0 ___ 9 __ / _ 1 __ 8 ___ / _ 2 __ 0 __ 2 ___ 6 __ CITY-26-33 PERMIT #: ___________________________________________________________________________ THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE BUILDING CODES. STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS ORDINANCES AND GEORGIA STATE LAWS. A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS. THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR TO THE CONCEALMENT OF WORK. REVISION DATES SHEET INDEX 1185 DUNWOOD RD AND 5901-C Peachtree Dunwoody Rd 1165 SPALDING DR SIDEWALK Suite 350, Atlanta, GA 30328 CITY OF SAN DY SPRINGS Tel 678.224.9730 | GFTInc.com CHECKED: DATE: DRAWING No. BACKCHECKED: DATE: | ||||||||
|---|---|---|---|---|---|---|---|---|
| 5901-C Peachtree Dunwoody Rd Suite 350, Atlanta, GA 30328 Tel 678.224.9730 | GFTInc.com | 1165 SPALDING DR SIDEWALK CITY OF SAN DY SPRINGS CHECKED: DATE: DRAWING No. BACKCHECKED: DATE: |
| RAWING NO. DESCRIPTION REVISION DATE | ||
|---|---|---|
| 1-0001 | COVER | |
| 2-0001 | INDEX | |
| 3-0001 | REVISION SUMMARY | |
| 4-0001 - 04-0002 | GENERAL NOTES | |
| 5-0001 | TYPICAL SECTIONS | |
| 6-0001 | SUMMARY OF QUANTITIES | |
| 7-0001 | QUANTITIES REQUIRED BY AMMENDMENT | |
| 8-0001 | QUANTITIES REQUIRED BY CONSTRUCTION | |
| 3-0001 | CONSTRUCTION PLAN | |
| 7-0001 | DRIVEWAY PROFILES | |
| 3-0001 - 23-0002 | CROSS SECTIONS | |
| 4-000A - 24-0001 | UTILITY PLANS | |
| 6-0001 | SIGNING AND MARKING PLANS | |
| 9-0001 - 29-0002 | TREE PROTECTION PLAN | |
| 8-0001 | SPECIAL CONSTRUCTION DETAIL | |
| 2-0001 - 52-0007 | EROSION CONTROL LEGEND AND UNIFORM CODE SHEET | |
| 4-0001 | BMP LOCATION DETAILS | |
| 6-0001 - 56-0002 | EROSION CONTROL DETAILS | |
| DRAWING NO. DESCRIPTION REVISION DATE |
|---|
| PERMIT APPROVED PERMITTED BY: ___N____i__c__o___l_e___ _B___r__o___w____n__________ DATE: _ 0 ___ 9 __ / _ 1 __ 8 ___ / _ 2 __ 0 __ 2 ___ 6 __ CITY-26-33 PERMIT #: ___________________________________________________________________________ THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE BUILDING CODES. STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS ORDINANCES AND GEORGIA STATE LAWS. A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS. THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR TO THE CONCEALMENT OF WORK. |
9/17/2026 GPLOT-ORD DUNWOODY_2 SERIES.dgn SANDY SPRINGS PROJECT ID
mfrias gplotborder-ORD-PO.tbl GEORGIA
DRAWING NO. DESCRIPTION REVISION DATE DRAWING NO. DESCRIPTION REVISION DATE
01-0001 COVER
02-0001 INDEX
03-0001 REVISION SUMMARY
04-0001 - 04-0002 GENERAL NOTES
05-0001 TYPICAL SECTIONS
06-0001 SUMMARY OF QUANTITIES
07-0001 QUANTITIES REQUIRED BY AMMENDMENT
08-0001 QUANTITIES REQUIRED BY CONSTRUCTION
13-0001 CONSTRUCTION PLAN
17-0001 DRIVEWAY PROFILES
23-0001 - 23-0002 CROSS SECTIONS
24-000A - 24-0001 UTILITY PLANS
26-0001 SIGNING AND MARKING PLANS
29-0001 - 29-0002 TREE PROTECTION PLAN
38-0001 SPECIAL CONSTRUCTION DETAIL
52-0001 - 52-0007 EROSION CONTROL LEGEND AND UNIFORM CODE SHEET
54-0001 BMP LOCATION DETAILS
56-0001 - 56-0002 EROSION CONTROL DETAILS
REVISION DATES
CHECKED: DATE: DRAWING No.
BACKCHECKED: DATE:
CORRECTED: DATE:
VERIFIED: DATE:
11/05/2020
8:38:59 AM
T6026-2
PERMIT
APPROVED
PERMITTED BY: ___N____i__c__o___l_e___ _B___r__o___w____n__________ DATE: _ 0 ___ 9 __ / _ 1 __ 8 ___ / _ 2 __ 0 __ 2 ___ 6 __
CITY-26-33
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
SHEET INDEX
1185 DUNWOOD RD AND
5901-C Peachtree Dunwoody Rd 1165 SPALDING DR SIDEWALK
Suite 350, Atlanta, GA 30328 CITY OF SAN DY SPRINGS
Tel 678.224.9730 | GFTInc.com
02-0001
GPLN-CE
| mfrias gplotborder-ORD-PO.tbl GEORGIA T6026-2 DRAWING NO. DESCRIPTION REVISION DATE DRAWING NO. DESCRIPTION REVISION DATE PERMIT APPROVED PERMITTED BY: ___N____i__c__o___l_e___ _B___r__o___w____n__________ DATE: _ 0 ___ 9 __ / _ 1 __ 8 ___ / _ 2 __ 0 __ 2 ___ 6 __ CITY-26-33 PERMIT #: ___________________________________________________________________________ THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE BUILDING CODES. STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS ORDINANCES AND GEORGIA STATE LAWS. A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS. THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR TO THE CONCEALMENT OF WORK. REVISION DATES REVISON SUMMARY 1165 SPALDING DR & 1185 5901-C Peachtree Dunwoody Rd DUNWOODY RD NE SIDEWALK Suite 350, Atlanta, GA 30328 CITY OF SAN DY SPRINGS Tel 678.224.9730 | GFTInc.com CHECKED: DATE: DRAWING No. BACKCHECKED: DATE: | ||||||||
|---|---|---|---|---|---|---|---|---|
| 5901-C Peachtree Dunwoody Rd Suite 350, Atlanta, GA 30328 Tel 678.224.9730 | GFTInc.com | DUNWOODY RD NE SIDEWALK CITY OF SAN DY SPRINGS CHECKED: DATE: DRAWING No. BACKCHECKED: DATE: |
| DRAWING NO. DESCRIPTION REVISION DATE | ||
|---|---|---|
| DRAWING NO. DESCRIPTION REVISION DATE | |||
|---|---|---|---|
| PERM | IT | ||
| APPROV PERMITTED BY: ___N____i__c__o___l_e___ _ | ED B___r__o___w____n__________ DATE: _ 0 ___ 9 __ / _ 1 __ 8 ___ / _ 2 __ 0 __ 2 ___ 6 __ | ||
| CITY-26-33 PERMIT #: ________________________ THESE PLANS WERE REVIEWED WITH | ___________________________________________________ RESPECT TO CITY BUILDING AND DEVELOPMENT CODES | ||
| ONLY. NO EFFORT WAS MADE TO CH PLUMBING DESIGN OTHER THAN TO C BUILDING CODES. | ECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR OMPARE THE SUBMITTED PLANS WITH THE APPLICABLE | ||
| STRUCTURAL INTEGRITY DURING CO OWNER AND THE OWNER'S AGENTS. ORDINANCES AND GEORGIA STATE L A SITE PRE-CONSTRUCTION MEETING | NSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS AWS. AND A BUILDING PRE-CONSTRUCTION MEETING ARE | ||
| REQUIRED AT THE BEGINNING OF THE THE OWNER AND THE OWNER'S AGEN TO THE CONCEALMENT OF WORK. | REQUIRED AT THE BEGINNING OF THE THE OWNER AND THE OWNER'S AGEN TO THE CONCEALMENT OF WORK. | PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS. T SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR | |
9/14/2026 GPLOT-ORD DUNWOODY_3 SERIES.dgn SANDY SPRINGS PROJECT ID
mfrias gplotborder-ORD-PO.tbl GEORGIA
DRAWING NO. DESCRIPTION REVISION DATE DRAWING NO. DESCRIPTION REVISION DATE
REVISION DATES
CHECKED: DATE: DRAWING No.
BACKCHECKED: DATE:
CORRECTED: DATE:
VERIFIED: DATE:
11/05/2020
2:49:34 PM
T6026-2
PERMIT
APPROVED
PERMITTED BY: ___N____i__c__o___l_e___ _B___r__o___w____n__________ DATE: _ 0 ___ 9 __ / _ 1 __ 8 ___ / _ 2 __ 0 __ 2 ___ 6 __
CITY-26-33
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
REVISON SUMMARY
1165 SPALDING DR & 1185
5901-C Peachtree Dunwoody Rd DUNWOODY RD NE SIDEWALK
Suite 350, Atlanta, GA 30328
CITY OF SAN DY SPRINGS
Tel 678.224.9730 | GFTInc.com
03-0001
GPLN-CE
| mfrias gplotborder-ORD-PO.tbl GEORGIA T6026-2 GENERAL NOTES 1. ALL WORK TO BE DONE IN ACCORDANCE WITH CITY OF SANDY SPRINGS TECHNICAL MANUAL AND CODE, CLEARING AND EARTHWORK CURRENT EDITION, AS WELL AS GDOT STANDARDS AS A BACKUP SOURCE. 9. AT LOCATIONS WHERE NEW PAVEMENT IS TO BE PLACED ADJACENT TO EXISTING PAVEMENT WITHOUT AN OVERLAY OR WHERE CURBING IS TO BE PLACED ACROSS A PAVED AREA, A 2. ALL KNOWN UTILITY FACILITIES ARE SHOWN SCHEMATICALLY ON HIGHWAY PLANS AND ARE NOT JOINT SHALL BE SAWED ON A LINE ESTABLISHED BY THE ENGINEER TO ENSURE PAVEMENT NECESSARILY ACCURATE IN LOCATION AS TO PLAN OR ELEVATION. UTILITY FACILITIES SUCH AS REMOVAL TO A NEAT LINE. THE COST FOR SAWED JOINTS, WHEN REQUIRED, SHALL BE SERVICE LINES OR UNKNOWN FACILITIES NOT SHOWN ON HIGHWAY PLANS WILL NOT RELIEVE THE INCLUDED IN PRICE BID FOR OTHER CONTRACT ITEMS. EXCEPT WHEN SAWING P.C.C. CONTRACTOR OF HIS RESPONSIBILITY UNDER THIS REQUIREMENT. "EXISTING UTILITY FACILITIES" CONCRETE PAVEMENT. MEANS ANY UTILITY THAT EXISTS ON THE HIGHWAY PROJECT IN ITS ORIGINAL, RELOCATED, OR NEWLY INSTALLED POSITION. ALL UTILITY FACILITIES WHICH ARE IN CONFLICT WITH CONSTRUCTION 10. WHERE EXISTING PAVEMENT MARKINGS AND LINES ARE IN CONFLICT WITH THE TRAFFIC AND ARE NOT COVERED AS SPECIFIC ITEMS IN THE DETAILED ESTIMATE ARE TO BE REMOVED OR PATTERN BEING USED ON CONSTRUCTION, THE CONTRACTOR SHALL REMOVE OR OVERLAY RELOCATED TO CLEAR CONSTRUCTION IN ADVANCE OF HIS WORK. LINES TO THE SATISFACTION OF THE ENGINEER SUCH THAT THE LINES DO NOT CONFUSE THE TRAVELING PUBLIC. ALL REMAINING LINES OR MARKINGS SHALL BE IN ACCORDANCE 3. THE FOLLOWING UTILITIES HAVE FACILITIES IN THE PROJECT AREA: WITH THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, CURRENT EDITION OR AS DIRECTED BY THE ENGINEER. TRAFFIC SHALL NOT BE ALLOWED ON ANY PAVEMENT NOT UTILITY OWNER SERVICE CONTACT INFORMATION PROPERLY STRIPED. AT&T TELECOMMUNICATIONS 11. THE CONTRACTOR'S ATTENTION IS DIRECTED TO ARTICLES 104.05 & 107.07 OF THE ATLANTA GAS LIGHT GAS (404)584-4126 STANDARD SPECIFICATIONS AND THE SPECIAL PROVISIONS FOR TRAFFIC CONTROL AND COLONIAL PIPELINE FUEL SEQUENCE OF OPERATIONS IN REGARDS TO MAINTENANCE OF TRAFFIC DURING CONSTRUCTION. COMCAST COMMUNICATIONS (770)833-1014 12. PRICE BID FOR TRAFFIC CONTROL-LUMP SUM SHALL INCLUDE, BUT IS NOT LIMITED TO, DEKALB COUNTYITS TRAFFIC TRAFFIC CONSTRUCTION, MAINTENANCE, AND REMOVAL OF TEMPORARY SIGNING AND PAVEMENT MARKINGS, DEKALB COUNTY SEWER SEWER BARRICADES, CHANNELIZING DEVICES, ETC. REQUIRED FOR MAINTENANCE OF TRAFFIC DURING CONSTRUCTION. ALL TEMPORARY SIGNING AND PAVEMENT MARKING SHALL BE IN ACCORDANCE DEKALB COUNTY WATER WATER WITH THE "MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES" CURRENT EDITION AND/OR AS DIRECTED BY THE ENGINEER. FULTON COUNTY SEWER WATER (404)612-9456 GEORGIA POWER COMPANY ELECTRIC DISTRIBUTION JSALLEN@SOUTHERNCO.COM 13. HANDICAP RAMPS SHALL BE CONSTRUCTED AT ALL POINTS WHERE SIDEWALK TERMINATES AT GOOGLE FIBER GEORGIA LLC FIBER OPTICS (478)697-5783 CURB OR IS BISECTED BY DRIVEWAYS, IF NECESSARY. TYPE OF RAMP MAY BE MODIFIED AS DIRECTED BY THE ENGINEER. IF A HANDICAP RAMP IS NOT INDICATED IN THE PLANS, CITY OF ATLANTA(COA) WATER (404)904-1202 ENSURE SIDEWALK LONGITUDINAL SLOPE DOES NOT EXCEED 5.00% WHERE SIDEWALK TIES CITY OF SANDY SPRINGS TRAFFIC CONTROL (770)-730-5600 TO EXISTING DRIVEWAYS. IF THE ADJACENT ROADWAY LONGITUDINAL SLOPE EXCEEDS 5.00%, SIDEWALK LONGITUDINAL SLOPE SHALL NOT EXCEED THE ADJACENT ROADWAY LONGITUDINAL SLOPE. 14. STRUCTURES, TREES, SHRUBS AND OTHER PLANT MATERIAL THAT FALL WITHIN THE RIGHT-OF-WAY AND EASEMENT LIMITS, BUT OUTSIDE THE LIMITS OF CONSTRUCTION, SHALL NOT BE DISTURBED UNLESS DIRECTED BY THE ENGINEER. 15. ALL CONCRETE SIDEWALKS AND WHEELCHAIR RAMPS LOCATED IN THE RADIUS RETURN SHALL BE 8" THICKNESS. 4. THE CONTRACTOR SHALL STRICTLY ADHERE TO DUST CONTROL REGULATIONS. ALL AREAS SUBJECTED 16. ALL CUT AND FILL SLOPES SHALL BE GRASSED AS DIRECTED BY THE ENGINEER IMMEDIATELY TO DUST FORMATION MUST BE PERIODICALLY WATERED. SUFFICIENT TO RETARD DUST. ALL COSTS AFTER THE SLOPES ARE ESTABLISHED IN ORDER TO REDUCE EROSION. IF THE SEASON DOES FOR DUST CONTROL SHALL BE INCLUDED IN PRICE BID FOR GRADING COMPLETE. NOT PERMIT GRASSING, TEMPORARY MULCH SHALL BE USED AS DIRECTED BY THE ENGINEER. REFER TO SECTION 161 OF THE STANDARD SPECIFICATIONS. 5. THE TOTAL AREA SHOWN ON THE PLANS FOR GRASSING IS FOR INFORMATION ONLY. THE CITY OF SANDY SPRINGS ASSUMES NO RESPONSIBILITY FOR ITS ACCURACY. THE CONTRACTOR SHALL BID ON 17. THE CONTRACTOR SHALL ENSURE THAT POSITIVE AND ADEQUATE DRAINAGE IS MAINTAINED AT GRASSING COMPLETE. LUMP SUM. AND IT SHALL BE HIS RESPONSIBILITY TO DETERMINE THE ACTUAL ALL TIMES WITHIN THE PROJECT LIMITS. THIS MAY INCLUDE, BUT IS NOT LIMITED TO, AREA TO BE GRASSED. NO CLAIMS WILL BE CONSIDERED FOR EXTRA COMPENSATION IF THE CONTRACTOR REPLACEMENT OR RECONSTRUCTION OF EXISTING DRAINAGE STRUCTURES THAT HAVE BEEN RELIES ON THE AREA SHOWN ON THE PLANS. THE ESTIMATED TOTAL AREA FOR GRASSING IS 0.03 ACRES. DAMAGED OR REMOVED OR RE-GRADED AS REQUIRED BY THE ENGINEER EXCEPT FOR THOSE DRAINAGE ITEMS SHOWN AT SPECIFIC LOCATIONS IN THE PLANS AND HAVING SPECIFIC 6. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FURNISH SUITABLE BORROW MATERIAL FOR PAY ITEMS IN THE DETAILED ESTIMATE. NO SEPARATE PAYMENT WILL BE MADE FOR ANY THE PROJECT AND DISPOSE OF ANY UNSUITABLE OR WASTE MATERIAL. COSTS INCURRED TO COMPLY WITH THIS REQUIREMENT. 7. HORIZONTAL CONTROL IS BASED UPON GEORGIA STATE PLANE COORDINATE SYSTEM. SEE CONSTRUCTION PERMIT PLANS FOR LOCATIONS AND DESCRIPTIONS OF MONUMENTS USED. APPROVED PERMITTED BY: ____N___i__c__o___l__e__ _B___r___o__w____n__________ DATE: _ 0 ___ 9 __ / _ 1 __ 8 ___ / _ 2 __ 0 __ 2 ___ 6 __ 8. ALL EXISTING PIPES AND DRAINAGE STRUCTURES SHALL BE RETAINED UNLESS OTHERWISE NOTED ON PERMIT #: _C___I__T__Y___-_2___6__-_3__3_______________________________________________________ PLANS TO BE REMOVED OR AS DIRECTED BY THE ENGINEER. COST FOR REMOVAL SHALL BE INCLUDED TOPB H LU NU E I L LM SY D E.BI N INP NG LOG A C EN DO FS ED F S WO EIGS RE .NTR EWO T RAH ESE V MR IEA T WDHEE A DTN OW T CI O TH H CE O RCM EKS P TP AHE REC E TS T TT HRO EU C SCI UTT BUY M RBAI U TLT IL, E DMD IEN PCG LH A AAN NNS DIC W DAE ILT V,H EE TLLEH OCE PT M ARE PICN PLAT I LC C OA O BRD L E E S IN THE PRICE FOR GRADING COMPLETE. SOO TWR R DNU IEN CRA T N UACNR EDA S L T A IHN NET D EO G GWR ENI O TER YRG D'SI U A A R SGI T NEA GNT TE CS O L. A N TW SHT SISR . UPCETRIMOINT IISS TSHUEB JTEOCTTA LT OR EASLPL OSNASNIDBYIL SITPYR OINFG TSHE ARTTHO ES E QI T T U HO EI EW RP E CN RD OE E RN -AC C TA O ENTN A HD S L E T TM RBHE UEEN GC TOIT NWO ION FN NI NEW M RG O' E SO R E KAFT .GTIN EHG NE T AP N SRD HO AJA LE B LC U RTI E LFD QOI URN E GAS LP TLR A PE NE- D CR OMP N AITS SST S RE A UXLCC LET IN IPO STN PT E MRC EAT EDI T OEI N NPS GE R P AMR R IIE OTSR. REVISION DATES GENERAL NOTES 1165 SPALDING DR & 1185 5901-C Peachtree Dunwoody Rd DUNWOODY RD NE SIDEWALK Suite 350, Atlanta, GA 30328 CITY OF SANDY SPRINGS Tel 678.224.9730 | GFTInc.com CHECKED: DATE: DRAWING No. BACKCHECKED: DATE: | ||||||||
|---|---|---|---|---|---|---|---|---|
| 5901-C Peachtree Dunwoody Rd Suite 350, Atlanta, GA 30328 Tel 678.224.9730 | GFTInc.com | 1165 SPALDING DR & 1185 DUNWOODY RD NE SIDEWALK CITY OF SANDY SPRINGS CHECKED: DATE: DRAWING No. BACKCHECKED: DATE: | |||||||
| UTILITY OWNER AT&T ATLANTA GAS LIGHT | SERVICE TELECOMMUNICATIONS GAS | CONTACT INFORMATION (404)584-4126 |
|---|---|---|
| COLONIAL PIPELINE COMCAST DEKALB COUNTYITS TRAFFIC | FUEL COMMUNICATIONS TRAFFIC | (770)833-1014 |
| DEKALB COUNTY SEWER DEKALB COUNTY WATER | SEWER WATER | |
| FULTON COUNTY SEWER | WATER | (404)612-9456 |
| GEORGIA POWER COMPANY GOOGLE FIBER GEORGIA LLC | ELECTRIC DISTRIBUTION FIBER OPTICS | JSALLEN@SOUTHERNCO.COM (478)697-5783 |
9/14/2026 GPLOT-ORD DUNWOODY_4 SERIES.dgn SANDY SPRINGS PROJECT ID
mfrias gplotborder-ORD-PO.tbl GEORGIA
GENERAL NOTES
1. ALL WORK TO BE DONE IN ACCORDANCE WITH CITY OF SANDY SPRINGS TECHNICAL MANUAL AND CODE, CLEARING AND EARTHWORK
CURRENT EDITION, AS WELL AS GDOT STANDARDS AS A BACKUP SOURCE. 9. AT LOCATIONS WHERE NEW PAVEMENT IS TO BE PLACED ADJACENT TO EXISTING PAVEMENT
WITHOUT AN OVERLAY OR WHERE CURBING IS TO BE PLACED ACROSS A PAVED AREA, A
2. ALL KNOWN UTILITY FACILITIES ARE SHOWN SCHEMATICALLY ON HIGHWAY PLANS AND ARE NOT JOINT SHALL BE SAWED ON A LINE ESTABLISHED BY THE ENGINEER TO ENSURE PAVEMENT
NECESSARILY ACCURATE IN LOCATION AS TO PLAN OR ELEVATION. UTILITY FACILITIES SUCH AS REMOVAL TO A NEAT LINE. THE COST FOR SAWED JOINTS, WHEN REQUIRED, SHALL BE
SERVICE LINES OR UNKNOWN FACILITIES NOT SHOWN ON HIGHWAY PLANS WILL NOT RELIEVE THE INCLUDED IN PRICE BID FOR OTHER CONTRACT ITEMS. EXCEPT WHEN SAWING P.C.C.
CONTRACTOR OF HIS RESPONSIBILITY UNDER THIS REQUIREMENT. "EXISTING UTILITY FACILITIES" CONCRETE PAVEMENT.
MEANS ANY UTILITY THAT EXISTS ON THE HIGHWAY PROJECT IN ITS ORIGINAL, RELOCATED, OR
NEWLY INSTALLED POSITION. ALL UTILITY FACILITIES WHICH ARE IN CONFLICT WITH CONSTRUCTION 10. WHERE EXISTING PAVEMENT MARKINGS AND LINES ARE IN CONFLICT WITH THE TRAFFIC
AND ARE NOT COVERED AS SPECIFIC ITEMS IN THE DETAILED ESTIMATE ARE TO BE REMOVED OR PATTERN BEING USED ON CONSTRUCTION, THE CONTRACTOR SHALL REMOVE OR OVERLAY
RELOCATED TO CLEAR CONSTRUCTION IN ADVANCE OF HIS WORK. LINES TO THE SATISFACTION OF THE ENGINEER SUCH THAT THE LINES DO NOT CONFUSE
THE TRAVELING PUBLIC. ALL REMAINING LINES OR MARKINGS SHALL BE IN ACCORDANCE
3. THE FOLLOWING UTILITIES HAVE FACILITIES IN THE PROJECT AREA: WITH THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, CURRENT EDITION OR AS
DIRECTED BY THE ENGINEER. TRAFFIC SHALL NOT BE ALLOWED ON ANY PAVEMENT NOT
UTILITY OWNER SERVICE CONTACT INFORMATION
PROPERLY STRIPED.
AT&T TELECOMMUNICATIONS
11. THE CONTRACTOR'S ATTENTION IS DIRECTED TO ARTICLES 104.05 & 107.07 OF THE
ATLANTA GAS LIGHT GAS (404)584-4126
STANDARD SPECIFICATIONS AND THE SPECIAL PROVISIONS FOR TRAFFIC CONTROL AND
COLONIAL PIPELINE FUEL SEQUENCE OF OPERATIONS IN REGARDS TO MAINTENANCE OF TRAFFIC DURING CONSTRUCTION.
COMCAST COMMUNICATIONS (770)833-1014
12. PRICE BID FOR TRAFFIC CONTROL-LUMP SUM SHALL INCLUDE, BUT IS NOT LIMITED TO,
DEKALB COUNTYITS TRAFFIC TRAFFIC
CONSTRUCTION, MAINTENANCE, AND REMOVAL OF TEMPORARY SIGNING AND PAVEMENT MARKINGS,
DEKALB COUNTY SEWER SEWER BARRICADES, CHANNELIZING DEVICES, ETC. REQUIRED FOR MAINTENANCE OF TRAFFIC DURING
CONSTRUCTION. ALL TEMPORARY SIGNING AND PAVEMENT MARKING SHALL BE IN ACCORDANCE
DEKALB COUNTY WATER WATER WITH THE "MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES" CURRENT EDITION AND/OR AS
DIRECTED BY THE ENGINEER.
FULTON COUNTY SEWER WATER (404)612-9456
GEORGIA POWER COMPANY ELECTRIC DISTRIBUTION JSALLEN@SOUTHERNCO.COM 13. HANDICAP RAMPS SHALL BE CONSTRUCTED AT ALL POINTS WHERE SIDEWALK TERMINATES AT
GOOGLE FIBER GEORGIA LLC FIBER OPTICS (478)697-5783 CURB OR IS BISECTED BY DRIVEWAYS, IF NECESSARY. TYPE OF RAMP MAY BE MODIFIED AS
DIRECTED BY THE ENGINEER. IF A HANDICAP RAMP IS NOT INDICATED IN THE PLANS,
CITY OF ATLANTA(COA) WATER (404)904-1202
ENSURE SIDEWALK LONGITUDINAL SLOPE DOES NOT EXCEED 5.00% WHERE SIDEWALK TIES
CITY OF SANDY SPRINGS TRAFFIC CONTROL (770)-730-5600 TO EXISTING DRIVEWAYS. IF THE ADJACENT ROADWAY LONGITUDINAL SLOPE EXCEEDS 5.00%,
SIDEWALK LONGITUDINAL SLOPE SHALL NOT EXCEED THE ADJACENT ROADWAY LONGITUDINAL SLOPE.
14. STRUCTURES, TREES, SHRUBS AND OTHER PLANT MATERIAL THAT FALL WITHIN THE RIGHT-OF-WAY
AND EASEMENT LIMITS, BUT OUTSIDE THE LIMITS OF CONSTRUCTION, SHALL NOT BE DISTURBED
UNLESS DIRECTED BY THE ENGINEER.
15. ALL CONCRETE SIDEWALKS AND WHEELCHAIR RAMPS LOCATED IN THE RADIUS RETURN SHALL
BE 8" THICKNESS.
4. THE CONTRACTOR SHALL STRICTLY ADHERE TO DUST CONTROL REGULATIONS. ALL AREAS SUBJECTED
16. ALL CUT AND FILL SLOPES SHALL BE GRASSED AS DIRECTED BY THE ENGINEER IMMEDIATELY
TO DUST FORMATION MUST BE PERIODICALLY WATERED. SUFFICIENT TO RETARD DUST. ALL COSTS
AFTER THE SLOPES ARE ESTABLISHED IN ORDER TO REDUCE EROSION. IF THE SEASON DOES
FOR DUST CONTROL SHALL BE INCLUDED IN PRICE BID FOR GRADING COMPLETE.
NOT PERMIT GRASSING, TEMPORARY MULCH SHALL BE USED AS DIRECTED BY THE ENGINEER.
REFER TO SECTION 161 OF THE STANDARD SPECIFICATIONS.
5. THE TOTAL AREA SHOWN ON THE PLANS FOR GRASSING IS FOR INFORMATION ONLY. THE CITY OF
SANDY SPRINGS ASSUMES NO RESPONSIBILITY FOR ITS ACCURACY. THE CONTRACTOR SHALL BID ON
17. THE CONTRACTOR SHALL ENSURE THAT POSITIVE AND ADEQUATE DRAINAGE IS MAINTAINED AT
GRASSING COMPLETE. LUMP SUM. AND IT SHALL BE HIS RESPONSIBILITY TO DETERMINE THE ACTUAL
ALL TIMES WITHIN THE PROJECT LIMITS. THIS MAY INCLUDE, BUT IS NOT LIMITED TO,
AREA TO BE GRASSED. NO CLAIMS WILL BE CONSIDERED FOR EXTRA COMPENSATION IF THE CONTRACTOR
REPLACEMENT OR RECONSTRUCTION OF EXISTING DRAINAGE STRUCTURES THAT HAVE BEEN
RELIES ON THE AREA SHOWN ON THE PLANS. THE ESTIMATED TOTAL AREA FOR GRASSING IS 0.03 ACRES.
DAMAGED OR REMOVED OR RE-GRADED AS REQUIRED BY THE ENGINEER EXCEPT FOR THOSE
DRAINAGE ITEMS SHOWN AT SPECIFIC LOCATIONS IN THE PLANS AND HAVING SPECIFIC
6. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FURNISH SUITABLE BORROW MATERIAL FOR
PAY ITEMS IN THE DETAILED ESTIMATE. NO SEPARATE PAYMENT WILL BE MADE FOR ANY
THE PROJECT AND DISPOSE OF ANY UNSUITABLE OR WASTE MATERIAL.
COSTS INCURRED TO COMPLY WITH THIS REQUIREMENT.
7. HORIZONTAL CONTROL IS BASED UPON GEORGIA STATE PLANE COORDINATE SYSTEM. SEE CONSTRUCTION
PLANS FOR LOCATIONS AND DESCRIPTIONS OF MONUMENTS USED.
8. ALL EXISTING PIPES AND DRAINAGE STRUCTURES SHALL BE RETAINED UNLESS OTHERWISE NOTED ON
PLANS TO BE REMOVED OR AS DIRECTED BY THE ENGINEER. COST FOR REMOVAL SHALL BE INCLUDED
IN THE PRICE FOR GRADING COMPLETE.
REVISION DATES
CHECKED: DATE: DRAWING No.
BACKCHECKED: DATE:
CORRECTED: DATE:
VERIFIED: DATE:
11/05/2020
2:50:46 PM
T6026-2
PERMIT
APPROVED
PERMITTED BY: ____N___i__c__o___l__e__ _B___r___o__w____n__________ DATE: _ 0 ___ 9 __ / _ 1 __ 8 ___ / _ 2 __ 0 __ 2 ___ 6 __
PERMIT #: _C___I__T__Y___-_2___6__-_3__3_______________________________________________________
TOPB H LU NU E I L LM SY D E.BI N INP NG LOG A C EN DO FS ED F S WO EIGS RE .NTR EWO T RAH ESE V MR IEA T WDHEE A DTN OW T CI O TH H CE O RCM EKS P TP AHE REC E TS T TT HRO EU C SCI UTT BUY M RBAI U TLT IL, E DMD IEN PCG LH A AAN NNS DIC W DAE ILT V,H EE TLLEH OCE PT M ARE PICN PLAT I LC C OA O BRD L E E S
SOO TWR R DNU IEN CRA T N UACNR EDA S L T A IHN NET D EO G GWR ENI O TER YRG D'SI U A A R SGI T NEA GNT TE CS O L. A N TW SHT SISR . UPCETRIMOINT IISS TSHUEB JTEOCTTA LT OR EASLPL OSNASNIDBYIL SITPYR OINFG TSHE
ARTTHO ES E QI T T U HO EI EW RP E CN RD OE E RN -AC C TA O ENTN A HD S L E T TM RBHE UEEN GC TOIT NWO ION FN NI NEW M RG O' E SO R E KAFT .GTIN EHG NE T AP N SRD HO AJA LE B LC U RTI E LFD QOI URN E GAS LP TLR A PE NE- D CR OMP N AITS SST S RE A UXLCC LET IN IPO STN PT E MRC EAT EDI T OEI N NPS GE R P AMR R IIE OTSR.
GENERAL NOTES
1165 SPALDING DR & 1185
5901-C Peachtree Dunwoody Rd DUNWOODY RD NE SIDEWALK
Suite 350, Atlanta, GA 30328 CITY OF SANDY SPRINGS
Tel 678.224.9730 | GFTInc.com
04-0001
GPLN-CE
| mfrias gplotborder-ORD-PO.tbl GEORGIA T6026-4 CONCRETE DRIVES: 18. ALL SILT FENCES MUST BE PLACED AS ACCESS IS OBTAINED DURING CLEARING. NO GRADING SHALL BE DONE UNTIL SILT FENCE INSTALLATION IS COMPLETE. IT IS THE CONTRACTOR'S RESIDENTIAL RESPONSIBILITY TO MAINTAIN ALL SILT FENCES AND TO REPAIR OR REPLACE ANY SILT - 6" CONCRETE VALLEY GUTTER FENCE THAT IS NOT SATISFACTORY. EROSION CONTROL CHECK DAMS SHALL BE PLACED - 4" CONCRETE DRIVEWAY IMMEDIATELY AFTER DRAINAGE STRUCTURES ARE IN PLACE. ALL EROSION CONTROL DEVICES SHALL BE PLACED ACCORDING TO THE PLANS AND AS DIRECTED BY THE ENGINEER. SEE THE ALL DRIVEWAYS WILL BE CONSTRUCTED TO THE TIE-DOWN. CONTRACTOR IS TO SAWCUT THE EDGE GDOT STANDARD SPECIFICATION REGARDING EROSION CONTROL AND THE MANUAL FOR EROSION OF PAVEMENT TO PROVIDE A SMOOTH EDGE. AND SEDIMENT CONTROL BY G.S.W.C.C. THE CONTRACTOR SHALL OBTAIN AND ABIDE BY ALL CORPS OF ENGINEERS RULES AND REGULATIONS CONCERNING CONSTRUCTION ADJACENT TO 25. CONTRACTOR TO COORDINATE WITH PROPERTY OWNER AND FOLLOW USPS GUIDELINES FOR WATERWAYS AND MAINTAIN WATER QUALITY. MONUMENT MAILBOX RELOCATIONS. 19. EROSION CONTROL MEASURES SHALL BE INSTALLED PRIOR TO LAND DISTURBANCE ACTIVITIES 26. DECORATIVE LIGHTING OR WIRING CONFLICTS WILL BE COORDINATED BETWEEN SANDY SPRINGS AND SHALL BE MAINTAINED AT ALL TIMES. ADDITIONAL EROSION AND SEDIMENT CONTROL AND THE PROPERTY OWNER. CONTRACTOR TO ENSURE NOT TO DAMAGE DECORATIVE LIGHTING OR DEVICES SHALL BE INSTALLED IF DEEMED NECESSARY BY ON-SITE INSPECTION OR AS DIRECTED WIRING AND SET ASIDE FOR THE PROPERTY OWNER TO RECONNECT UPON COMPLETION OF BY THE ENGINEER. CONSTRUCTION. 20. A NOTICE OF INTENT (NOI) IS NOT REQUIRED FOR THIS PROJECT. THIS PROJECT HAS A TOTAL AREA OF 0.56 ACRES AND THE EXPECTED DISTURBED AREA OF IS 0.14 ACRES. THE MAINTENANCE OF TRAFFIC TOTAL AREA IS THE TOTAL AREA OF THE RIGHT OF WAY AND EASEMENTS, AND THE DISTURBED AREA IS THE AREA ASSOCIATED WITH CLEARING, GRADING, EXCAVATING, 1. ALL ITEMS NECESSARY FOR COMPLIANCE WITH THESE REQUIREMENTS SHALL BE INCLUDED IN THE FILLING OF LAND, OR OTHER SIMILAR ACTIVITIES WHICH MAY RESULT IN SOIL EROSION, PRICE BID FOR TRAFFIC CONTROL, LUMP SUM. AS DEFINED UNDER "CONSTRUCTION ACTIVITIES" IN THE STATE OF GEORGIA NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) GENERAL PERMIT NO. GAR100002. 2. ALL SIGNS AND PAVEMENT MARKINGS SHALL CONFORM TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, AND STANDARD HIGHWAY SIGNS, (LATEST EDITIONS). 21. TYPE OF SOD USED ON THIS PROJECT, UNLESS OTHERWISE SHOWN, WILL BE REQUIRED TO MATCH ANY TYPE OF GRASS OR SOD WHICH MAY BE PLANTED AND GROWING ON THE ADJACENT LAWN. I.E. 3. ALL TEMPORARY SIGNS SHALL HAVE HIGH INTENSITY REFLECTORIZED SHEETING ON METAL SIGN BERMUDA SOD FOR BERMUDA SOD, ZOYSIA FOR ZOYSIA, ETC. NO SEPARATE PAYMENT WILL BE MADE PANELS. PLYWOOD SIGN PANELS ARE PROHIBITED. FOR ANY COST INCURRED TO COMPLY WITH THIS REQUIREMENT. THE TOTAL COST OF THIS REQUIREMENT SHALL BE INCLUDED IN THE BID ITEM COST FOR NO. 700-9300 - SOD. 4. IN RESIDENTIAL AREAS SIGNS SHALL BE LOCATED ON, OR AS CLOSE AS POSSIBLE TO, PROPERTY LINES. 22. UNLESS OTHERWISE SPECIFIED OR DIRECTED BY THE INSPECTOR, ALL WATER LINES SHALL HAVE A MINIMUM OF 48 INCHES OF COVER. 5. EXISTING TRAFFIC SIGNS SHALL BE MAINTAINED BY THE CONTRACTOR THROUGHOUT CONSTRUCTION. MAINTENANCE INCLUDES REPLACING DAMAGED AND STOLEN SIGNS, AND 23. TRIM ALL TREE LIMBS TO PROVIDE A MINIMUM OF 10' CLEARANCE ABOVE THE SIDEWALK. PERIODIC CLEANING OF EXISTING SIGNS, BARRELS, AND OTHER CONSTRUCTION THIS WORK SHALL BE PAID FOR UNDER PAY ITEM 210-0100 GRADING COMPLETE. RELATED TRAFFIC CONTROL DEVICES. 24. ALL DRIVEWAYS, WHERE ACCESS IS ALLOWED, SHALL BE PLACED AS DIRECTED BY THE ENGINEER 6. EXISTING PAVEMENT MARKINGS THAT CONFLICT WITH TRAFFIC SHIFTS SHALL BE OBLITERATED IN ACCORDANCE WITH RULES AND REGULATIONS FOR CONTROL AND PROTECTION OF DEPARTMENT OF BY THE CONTRACTOR BY GRINDING OR PAVING OVER. "BLACK OUT" PAINT IS PROHIBITED. TRANSPORTATION RIGHTS-OF-WAY. ALL DRIVEWAYS THAT ARE TO BE RECONSTRUCTED SHALL BE REPLACED, IN KIND, I.E., ASPHALT FOR ASPHALT, CONCRETE FOR CONCRETE, AND ASPHALT 7. ONLY REFLECTORIZED PLASTIC DRUMS AND TEMPORARY CONCRETE BARRIERS SHALL BE USED SURFACE COURSE FOR EARTH, UNLESS DIRECTED BY THE ENGINEER. DRIVEWAY PROFILES OVER 11% ADJACENT TO TRAVEL LANES. TYPE I AND TYPE II BARRICADES AND CONES SHALL NOT BE USED. IN GRADE SHALL BE CONSTRUCTED WITH CONCRETE, UNLESS DIRECTED BY THE ENGINEER. THE DRIVEWAY LOCATIONS INDICATED ON THE PLANS ARE FROM THE BEST AVAILABLE DATA. 8. ALL REFLECTORIZED PLASTIC DRUMS AND TEMPORARY CONCRETE BARRIERS SHALL BE PLACED THE CONTRACTORS SHALL CONSTRUCT NEW DRIVEWAYS TO MATCH THE ACTUAL FIELD LOCATION A MINIMUM OF 2 FEET (0.6 M) FROM THE EDGE OF THE TRAVEL LANES UNLESS PRIOR APPROVAL OF EXISTING DRIVEWAYS WHERE THEY ARE NOT IN CONFLICT WITH THE RULES AND REGULATIONS. IS GRANTED BY THE DEPARTMENT OF PUBLIC WORKS. THE CONTRACTOR SHALL OBTAIN APPROVAL OF THE ENGINEER PRIOR TO MAKING ANY REVISIONS SUCH AS TO LOCATION, WIDTH AND/OR NUMBER OF DRIVES TO BE CONSTRUCTED. WHERE REQUIRED 9. THE CONTRACTOR SHALL MAINTAIN INGRESS AND EGRESS TO DRIVEWAYS AT ALL TIMES. THE DRIVES SHALL BE PAVED AS FOLLOWS: 10. ALL TRAFFIC CONTROL DEVICES SHALL BE MAINTAINED BY THE CONTRACTOR SO AS TO NOT INTERFERE WITH SIGHT DISTANCE ALONG ANY ADJACENT SIDE ROAD OR DRIVEWAY. 11. REFLECTORIZED DRUMS SHALL BE PROVIDED FOR CHANNELIZATION OF TRAFFIC IN ALL TRAFFIC PERMIT SHIFTS. MAXIMUM SPACING EQUALS THE DESIGN SPEED LIMIT FOR THE TAPER. APPROVED PERMITTED BY: ___N____i__c__o___l_e___ _B___r__o___w____n__________ DATE: _ 0 ___ 9 __ / _ 1 __ 8 ___ / _ 2 __ 0 __ 2 ___ 6 __ CITY-26-33 PERMIT #: ___________________________________________________________________________ THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE BUILDING CODES. STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS ORDINANCES AND GEORGIA STATE LAWS. A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS. THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR TO THE CONCEALMENT OF WORK. REVISION DATES GENERAL NOTES 1165 SPALDING DR & 1185 5901-C Peachtree Dunwoody Rd DUNWOODY RD NE SIDEWALK Suite 350, Atlanta, GA 30328 CITY OF SANDY SPRINGS Tel 678.224.9730 | GFTInc.com CHECKED: DATE: DRAWING No. BACKCHECKED: DATE: | ||||||||
|---|---|---|---|---|---|---|---|---|
| 5901-C Peachtree Dunwoody Rd Suite 350, Atlanta, GA 30328 Tel 678.224.9730 | GFTInc.com | DUNWOODY RD NE SIDEWALK CITY OF SANDY SPRINGS CHECKED: DATE: DRAWING No. BACKCHECKED: DATE: |
9/17/2026 GPLOT-ORD DUNWOODY_4 SERIES.dgn SANDY SPRINGS PROJECT ID
mfrias gplotborder-ORD-PO.tbl GEORGIA
CONCRETE DRIVES:
18. ALL SILT FENCES MUST BE PLACED AS ACCESS IS OBTAINED DURING CLEARING. NO GRADING
SHALL BE DONE UNTIL SILT FENCE INSTALLATION IS COMPLETE. IT IS THE CONTRACTOR'S
RESIDENTIAL
RESPONSIBILITY TO MAINTAIN ALL SILT FENCES AND TO REPAIR OR REPLACE ANY SILT
- 6" CONCRETE VALLEY GUTTER
FENCE THAT IS NOT SATISFACTORY. EROSION CONTROL CHECK DAMS SHALL BE PLACED
- 4" CONCRETE DRIVEWAY
IMMEDIATELY AFTER DRAINAGE STRUCTURES ARE IN PLACE. ALL EROSION CONTROL DEVICES
SHALL BE PLACED ACCORDING TO THE PLANS AND AS DIRECTED BY THE ENGINEER. SEE THE
ALL DRIVEWAYS WILL BE CONSTRUCTED TO THE TIE-DOWN. CONTRACTOR IS TO SAWCUT THE EDGE
GDOT STANDARD SPECIFICATION REGARDING EROSION CONTROL AND THE MANUAL FOR EROSION
OF PAVEMENT TO PROVIDE A SMOOTH EDGE.
AND SEDIMENT CONTROL BY G.S.W.C.C. THE CONTRACTOR SHALL OBTAIN AND ABIDE BY ALL
CORPS OF ENGINEERS RULES AND REGULATIONS CONCERNING CONSTRUCTION ADJACENT TO
25. CONTRACTOR TO COORDINATE WITH PROPERTY OWNER AND FOLLOW USPS GUIDELINES FOR
WATERWAYS AND MAINTAIN WATER QUALITY.
MONUMENT MAILBOX RELOCATIONS.
19. EROSION CONTROL MEASURES SHALL BE INSTALLED PRIOR TO LAND DISTURBANCE ACTIVITIES
26. DECORATIVE LIGHTING OR WIRING CONFLICTS WILL BE COORDINATED BETWEEN SANDY SPRINGS
AND SHALL BE MAINTAINED AT ALL TIMES. ADDITIONAL EROSION AND SEDIMENT CONTROL
AND THE PROPERTY OWNER. CONTRACTOR TO ENSURE NOT TO DAMAGE DECORATIVE LIGHTING OR
DEVICES SHALL BE INSTALLED IF DEEMED NECESSARY BY ON-SITE INSPECTION OR AS DIRECTED
WIRING AND SET ASIDE FOR THE PROPERTY OWNER TO RECONNECT UPON COMPLETION OF
BY THE ENGINEER.
CONSTRUCTION.
20. A NOTICE OF INTENT (NOI) IS NOT REQUIRED FOR THIS PROJECT. THIS PROJECT HAS A TOTAL
AREA OF 0.56 ACRES AND THE EXPECTED DISTURBED AREA OF IS 0.14 ACRES. THE
MAINTENANCE OF TRAFFIC
TOTAL AREA IS THE TOTAL AREA OF THE RIGHT OF WAY AND EASEMENTS, AND
THE DISTURBED AREA IS THE AREA ASSOCIATED WITH CLEARING, GRADING, EXCAVATING,
1. ALL ITEMS NECESSARY FOR COMPLIANCE WITH THESE REQUIREMENTS SHALL BE INCLUDED IN THE
FILLING OF LAND, OR OTHER SIMILAR ACTIVITIES WHICH MAY RESULT IN SOIL EROSION,
PRICE BID FOR TRAFFIC CONTROL, LUMP SUM.
AS DEFINED UNDER "CONSTRUCTION ACTIVITIES" IN THE STATE OF GEORGIA NATIONAL POLLUTANT
DISCHARGE ELIMINATION SYSTEM (NPDES) GENERAL PERMIT NO. GAR100002.
2. ALL SIGNS AND PAVEMENT MARKINGS SHALL CONFORM TO THE MANUAL ON UNIFORM TRAFFIC
CONTROL DEVICES, AND STANDARD HIGHWAY SIGNS, (LATEST EDITIONS).
21. TYPE OF SOD USED ON THIS PROJECT, UNLESS OTHERWISE SHOWN, WILL BE REQUIRED TO MATCH
ANY TYPE OF GRASS OR SOD WHICH MAY BE PLANTED AND GROWING ON THE ADJACENT LAWN. I.E.
3. ALL TEMPORARY SIGNS SHALL HAVE HIGH INTENSITY REFLECTORIZED SHEETING ON METAL SIGN
BERMUDA SOD FOR BERMUDA SOD, ZOYSIA FOR ZOYSIA, ETC. NO SEPARATE PAYMENT WILL BE MADE
PANELS. PLYWOOD SIGN PANELS ARE PROHIBITED.
FOR ANY COST INCURRED TO COMPLY WITH THIS REQUIREMENT. THE TOTAL COST OF THIS
REQUIREMENT SHALL BE INCLUDED IN THE BID ITEM COST FOR NO. 700-9300 - SOD.
4. IN RESIDENTIAL AREAS SIGNS SHALL BE LOCATED ON, OR AS CLOSE AS POSSIBLE TO,
PROPERTY LINES.
22. UNLESS OTHERWISE SPECIFIED OR DIRECTED BY THE INSPECTOR, ALL WATER LINES SHALL HAVE A
MINIMUM OF 48 INCHES OF COVER.
5. EXISTING TRAFFIC SIGNS SHALL BE MAINTAINED BY THE CONTRACTOR THROUGHOUT
CONSTRUCTION. MAINTENANCE INCLUDES REPLACING DAMAGED AND STOLEN SIGNS, AND
23. TRIM ALL TREE LIMBS TO PROVIDE A MINIMUM OF 10' CLEARANCE ABOVE THE SIDEWALK.
PERIODIC CLEANING OF EXISTING SIGNS, BARRELS, AND OTHER CONSTRUCTION
THIS WORK SHALL BE PAID FOR UNDER PAY ITEM 210-0100 GRADING COMPLETE.
RELATED TRAFFIC CONTROL DEVICES.
24. ALL DRIVEWAYS, WHERE ACCESS IS ALLOWED, SHALL BE PLACED AS DIRECTED BY THE ENGINEER
6. EXISTING PAVEMENT MARKINGS THAT CONFLICT WITH TRAFFIC SHIFTS SHALL BE OBLITERATED
IN ACCORDANCE WITH RULES AND REGULATIONS FOR CONTROL AND PROTECTION OF DEPARTMENT OF
BY THE CONTRACTOR BY GRINDING OR PAVING OVER. "BLACK OUT" PAINT IS PROHIBITED.
TRANSPORTATION RIGHTS-OF-WAY. ALL DRIVEWAYS THAT ARE TO BE RECONSTRUCTED SHALL BE
REPLACED, IN KIND, I.E., ASPHALT FOR ASPHALT, CONCRETE FOR CONCRETE, AND ASPHALT
7. ONLY REFLECTORIZED PLASTIC DRUMS AND TEMPORARY CONCRETE BARRIERS SHALL BE USED
SURFACE COURSE FOR EARTH, UNLESS DIRECTED BY THE ENGINEER. DRIVEWAY PROFILES OVER 11%
ADJACENT TO TRAVEL LANES. TYPE I AND TYPE II BARRICADES AND CONES SHALL NOT BE USED.
IN GRADE SHALL BE CONSTRUCTED WITH CONCRETE, UNLESS DIRECTED BY THE ENGINEER.
THE DRIVEWAY LOCATIONS INDICATED ON THE PLANS ARE FROM THE BEST AVAILABLE DATA.
8. ALL REFLECTORIZED PLASTIC DRUMS AND TEMPORARY CONCRETE BARRIERS SHALL BE PLACED
THE CONTRACTORS SHALL CONSTRUCT NEW DRIVEWAYS TO MATCH THE ACTUAL FIELD LOCATION
A MINIMUM OF 2 FEET (0.6 M) FROM THE EDGE OF THE TRAVEL LANES UNLESS PRIOR APPROVAL
OF EXISTING DRIVEWAYS WHERE THEY ARE NOT IN CONFLICT WITH THE RULES AND REGULATIONS.
IS GRANTED BY THE DEPARTMENT OF PUBLIC WORKS.
THE CONTRACTOR SHALL OBTAIN APPROVAL OF THE ENGINEER PRIOR TO MAKING ANY REVISIONS
SUCH AS TO LOCATION, WIDTH AND/OR NUMBER OF DRIVES TO BE CONSTRUCTED. WHERE REQUIRED
9. THE CONTRACTOR SHALL MAINTAIN INGRESS AND EGRESS TO DRIVEWAYS AT ALL TIMES.
THE DRIVES SHALL BE PAVED AS FOLLOWS:
10. ALL TRAFFIC CONTROL DEVICES SHALL BE MAINTAINED BY THE CONTRACTOR SO AS TO NOT
INTERFERE WITH SIGHT DISTANCE ALONG ANY ADJACENT SIDE ROAD OR DRIVEWAY.
11. REFLECTORIZED DRUMS SHALL BE PROVIDED FOR CHANNELIZATION OF TRAFFIC IN ALL TRAFFIC
SHIFTS. MAXIMUM SPACING EQUALS THE DESIGN SPEED LIMIT FOR THE TAPER.
REVISION DATES
CHECKED: DATE: DRAWING No.
BACKCHECKED: DATE:
CORRECTED: DATE:
VERIFIED: DATE:
11/05/2020
8:38:12 AM
T6026-4
PERMIT
APPROVED
PERMITTED BY: ___N____i__c__o___l_e___ _B___r__o___w____n__________ DATE: _ 0 ___ 9 __ / _ 1 __ 8 ___ / _ 2 __ 0 __ 2 ___ 6 __
CITY-26-33
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
GENERAL NOTES
1165 SPALDING DR & 1185
5901-C Peachtree Dunwoody Rd DUNWOODY RD NE SIDEWALK
Suite 350, Atlanta, GA 30328 CITY OF SANDY SPRINGS
Tel 678.224.9730 | GFTInc.com
04-0002
GPLN-CE
| mfrias gplotborder-ORD-PO.tbl GEORGIA T6026-2 SPALDING DRIVE EXISTING DUNWOODY ROAD VARIABLE SHOULDER EXISTING VARIABLE VARIABLE 9' - 13.25' VARIABLE SHOULDER EXISTING EXISTING VARIABLE VARIABLE VARIABLE 9' - 13.25' TRAVEL LANE TRAVEL LANE EXISTING EXISTING VARIABLE VARIABLE LANDSCAPE STRIP* TRAVEL LANE TRAVEL LANE VARIABLE LANDSCAPE STRIP* 6' MAX SIDEWALK VARIABLE SIDEWALK 1'SIDEWALK BUFFER 1'SIDEWALK BUFFER SOD SOD SAWCUT 2.00% SAWCUT EXST EXST (MAX) 2.00% 2:1 EXST EXST (MAX) TYP 2:1 B TYP C B1 A B DUNWOODY ROAD GAP FILL B2** C B1 A TYPICAL SECTION (SEE B2** EAST BOUND SIDEWALK NOTE) (SEE N.T.S DUNWOODY ROAD GAP FILL NOTE) TYPICAL SECTION STA 2+00 - 2+43.78 EAST BOUND SIDEWALK N.T.S STA 9+89.06 - 13+41.96 REQUIRED PAVEMENT NOTE: CONTRACTOR SHALL OBTAIN TINTED CONCRETE FROM AND APPROVED CONCRETE PLANT. THE CONCRETE SHALL BE TINTED TO CLOSELY MATCH THE ADJACENT ASPHALT A CONCRETE SIDEWALK, 4 IN PAVEMENT COLOR. ALL TINTING SHALL BE CONSISTENT THROUGHT THE PROJECT AND SUJECT TO ENGINEERS APPROVAL. B CONCRETE CURB AND GUTTER , 6" X 24", TP2 (GA STD. 9032B) *LANDSCAPE STRIP WIDTH VARIES SEE PLAN FOR DETAILS B1 GR AGGR BASE CRS, INCL MATL (6") **CLASS B CONCRETE WILL BE USED, AS DIRECTED BY THE ENGINEER, IN CASES WHERE THE SAW CUT OF EXISTING PAVEMENT IS NOT B2 CLASS B CONC. BASE OR PAVEMENT WIDENING (SEE NOTE) CONSISTENT AND THERE ARE GAPS BETWEEN THE PROPOSED CURB & GUTTER AND THE EXISTING PAVEMENT. CONTRACTOR TO ENSURE C EXISTING PAVEMENT TO BE RETAINED POSITIVE DRAINAGE. D SOD PERMIT APPROVED PERMITTED BY: ___N____i__c__o___l_e___ _B___r__o___w____n__________ DATE: _ 0 ___ 9 __ / _ 1 __ 8 ___ / _ 2 __ 0 __ 2 ___ 6 __ CITY-26-33 PERMIT #: ___________________________________________________________________________ THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE BUILDING CODES. STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS ORDINANCES AND GEORGIA STATE LAWS. A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS. THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR TO THE CONCEALMENT OF WORK. REVISION DATES TYPICAL SECTIONS 1165 SPALDING DR & 1185 5901-C Peachtree Dunwoody Rd DUNWOODY RD NE SIDEWALK Suite 350, Atlanta, GA 30328 CITY OF SANDY SPRINGS Tel 678.224.9730 | GFTInc.com CHECKED: DATE: DRAWING No. BACKCHECKED: DATE: | ||||||
|---|---|---|---|---|---|---|
| 5901-C Peachtree Dunwoody Rd Suite 350, Atlanta, GA 30328 Tel 678.224.9730 | GFTInc.com | C B | DUNWOODY RD NE SIDEWALK CITY OF SANDY SPRINGS HECKED: DATE: DRAWING No. ACKCHECKED: DATE: |
| VARIABLE VARIABLE LAN STRIP* VARIABLE SIDEWALK |
|---|
| 2.00% |
| 2.00% (MAX) |
|---|
9/14/2026 GPLOT-ORD DUNWOODY_05 SERIES.dgn SANDY SPRINGS PROJECT ID
mfrias gplotborder-ORD-PO.tbl GEORGIA
SPALDING DRIVE
EXISTING
DUNWOODY ROAD
VARIABLE SHOULDER EXISTING
VARIABLE VARIABLE 9' - 13.25' VARIABLE SHOULDER
EXISTING EXISTING VARIABLE VARIABLE VARIABLE 9' - 13.25'
TRAVEL LANE TRAVEL LANE EXISTING EXISTING VARIABLE
VARIABLE LANDSCAPE
STRIP* TRAVEL LANE TRAVEL LANE VARIABLE LANDSCAPE
STRIP*
6' MAX
SIDEWALK VARIABLE
SIDEWALK
1'SIDEWALK
BUFFER 1'SIDEWALK
BUFFER
SOD
SOD
SAWCUT
2.00% SAWCUT
EXST EXST (MAX) 2.00%
2:1 EXST EXST (MAX)
TYP 2:1
B TYP
C B1 A B
DUNWOODY ROAD GAP FILL B2** C B1 A
TYPICAL SECTION (SEE B2**
EAST BOUND SIDEWALK NOTE) (SEE
N.T.S DUNWOODY ROAD GAP FILL NOTE)
TYPICAL SECTION
STA 2+00 - 2+43.78 EAST BOUND SIDEWALK
N.T.S
STA 9+89.06 - 13+41.96
REQUIRED PAVEMENT
NOTE: CONTRACTOR SHALL OBTAIN TINTED CONCRETE FROM
AND APPROVED CONCRETE PLANT. THE CONCRETE SHALL
BE TINTED TO CLOSELY MATCH THE ADJACENT ASPHALT A CONCRETE SIDEWALK, 4 IN
PAVEMENT COLOR. ALL TINTING SHALL BE CONSISTENT
THROUGHT THE PROJECT AND SUJECT TO ENGINEERS APPROVAL. B CONCRETE CURB AND GUTTER , 6" X 24", TP2 (GA STD. 9032B)
*LANDSCAPE STRIP WIDTH VARIES SEE PLAN FOR DETAILS B1 GR AGGR BASE CRS, INCL MATL (6")
**CLASS B CONCRETE WILL BE USED, AS DIRECTED BY THE ENGINEER,
IN CASES WHERE THE SAW CUT OF EXISTING PAVEMENT IS NOT B2 CLASS B CONC. BASE OR PAVEMENT WIDENING (SEE NOTE)
CONSISTENT AND THERE ARE GAPS BETWEEN THE PROPOSED CURB
& GUTTER AND THE EXISTING PAVEMENT. CONTRACTOR TO ENSURE C EXISTING PAVEMENT TO BE RETAINED
POSITIVE DRAINAGE.
D SOD
REVISION DATES
CHECKED: DATE: DRAWING No.
BACKCHECKED: DATE:
CORRECTED: DATE:
VERIFIED: DATE:
11/05/2020
2:48:29 PM
T6026-2
PERMIT
APPROVED
PERMITTED BY: ___N____i__c__o___l_e___ _B___r__o___w____n__________ DATE: _ 0 ___ 9 __ / _ 1 __ 8 ___ / _ 2 __ 0 __ 2 ___ 6 __
CITY-26-33
PERMIT #: ___________________________________________________________________________
THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES
ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR
PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE
BUILDING CODES.
STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE
OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS
ORDINANCES AND GEORGIA STATE LAWS.
A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE
REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS.
THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR
TO THE CONCEALMENT OF WORK.
TYPICAL SECTIONS
1165 SPALDING DR & 1185
5901-C Peachtree Dunwoody Rd DUNWOODY RD NE SIDEWALK
Suite 350, Atlanta, GA 30328 CITY OF SANDY SPRINGS
Tel 678.224.9730 | GFTInc.com
05-0001
GPLN-CE
| mfrias gplotborder-ORD-PO.tbl GEORGIA T6026-2 PERMIT APPROVED PERMITTED BY: ___N____i__c__o___l_e___ _B___r__o___w____n__________ DATE: _ 0 ___ 9 __ / _ 1 __ 8 ___ / _ 2 __ 0 __ 2 ___ 6 __ CITY-26-33 PERMIT #: ___________________________________________________________________________ THESE PLANS WERE REVIEWED WITH RESPECT TO CITY BUILDING AND DEVELOPMENT CODES ONLY. NO EFFORT WAS MADE TO CHECK THE STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DESIGN OTHER THAN TO COMPARE THE SUBMITTED PLANS WITH THE APPLICABLE BUILDING CODES. STRUCTURAL INTEGRITY DURING CONSTRUCTION IS THE TOTAL RESPONSIBILITY OF THE OWNER AND THE OWNER'S AGENTS. THIS PERMIT IS SUBJECT TO ALL SANDY SPRINGS ORDINANCES AND GEORGIA STATE LAWS. A SITE PRE-CONSTRUCTION MEETING AND A BUILDING PRE-CONSTRUCTION MEETING ARE REQUIRED AT THE BEGINNING OF THE PROJECT FOR ALL PERMITS EXCEPT TRADE PERMITS. THE OWNER AND THE OWNER'S AGENT SHALL REQUEST AND PASS ALL INSPECTIONS PRIOR TO THE CONCEALMENT OF WORK. REVISION DATES SUMMARY OF QUANTITIES 1165 SPALDING DR & 1185 5901-C Peachtree Dunwoody Rd DUNWOODY RD NE SIDEWALK Suite 350, Atlanta, GA 30328 Tel 678.224.9730 | GFTInc.com CITY OF SANDY SPRINGS CHECKED: DATE: DRAWING No. BACKCHECKED: DATE: | ||||||||
|---|---|---|---|---|---|---|---|---|
| 5901-C Peachtree Dunwoody Rd Suite 350, Atlanta, GA 30328 Tel 678.224.9730 | GFTInc.com | DUNWOODY RD NE SIDEWALK CITY OF SANDY SPRINGS CHECKED: DATE: DRAWING No. BACKCHECKED: DATE: |

With GovernmentContracts, you can:
...Project: CONSTRUCTION TIME AND MATERIALS Ref. #: RFP 27-261110 Type: RFP Status: Open ...
Paulding County School District
Bid Due: 12/10/2026
...CONSTRUCTION TIME AND MATERIALS Paulding County School District Nov 10, 2026 @ 09:31 ...
State Government of Georgia
Bid Due: 12/10/2026
...Construction Manager at Risk (CMAR) Preconstruction and Construction Services for Middle Oconee WRF... ...
State Government of Georgia
Bid Due: 12/17/2026
...Follow Prefabrication Training Venues and Construction Supplies Active Contract Opportunity Notice...
HOMELAND SECURITY, DEPARTMENT OF
Bid Due: 12/29/2026