Hearing Aid Manufacturer
| Location: |
Oklahoma |
| Posted: |
Dec 3, 2025 |
| Due: |
Dec 17, 2025 |
| Agency: |
HEALTH AND HUMAN SERVICES, DEPARTMENT OF |
| Type of Government: |
Federal |
| Category: |
- 65 - Medical, Dental, and Veterinary Equipment and Supplies
|
| Solicitation No: |
IHSOKC2026-01 |
| Publication URL: |
To access bid details, please log in. |
Hearing Aid Manufacturer
Active
Contract Opportunity
Department/Ind. Agency
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Sub-tier
INDIAN HEALTH SERVICE
Office
OK CITY AREA INDIAN HEALTH SVC
Looking for contract opportunity help?
General Information
-
Contract Opportunity Type: Sources Sought (Original)
-
Original Published Date: Dec 03, 2025 05:59 am CST
-
Original Response Date: Dec 17, 2025 06:00 am CST
-
Inactive Policy: 15 days after response date
-
Original Inactive Date:
Jan 01, 2026
-
Initiative:
Classification
-
Original Set Aside: Indian Economic Enterprise (IEE) Set-Aside (specific to Department of Interior and Indian Health Services)
-
Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
-
NAICS Code:
-
334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
-
Place of Performance:
Oklahoma City
,
OK
73131
USA
Description
THE GOVERNMENT IS NOT LOOKING FOR A RESELLER OR PASS THROUGH, RATHER ACTUAL MANUFACTURES.
-
-
All hearing aids shall be fully programmable.
-
Minimum shade/color availability shall be:
-
Dark brown, medium brown, and beige/light skin tone colors
-
Highly Contrasting colors (for example: black and white, black/light grey) for a matching set of hearing aids for use with the dual sensory population.
-
Sixteen (16) or more channels
-
Three or more programs
-
Adaptive directional microphone technology, unless not technologically feasible due to the size of the instrument
-
Adaptive signal processing.
-
Noise reduction strategies for steady state and transient noise.
-
Wireless programmability, unless not technologically feasible due to the size of the instrument
-
Programs accessible by the user.
-
Active feedback suppression.
-
Data logging.
-
Wireless communication between hearing aids, of a binaural set, unless not technologically feasible due to the size of the instrument
-
Average total harmonic distortion (THD) calculated by averaging the values measured at 500 Hz, 800 Hz, and 1600 Hz according to the procedures specified in American National Standards Institute (ANSI) Acoustical Society of America (ASA) S3.22-2014 shall be less than 5%.
-
Equivalent input noise level measured according to the procedures specified in ANSI/ASA S3.22-2014 shall not exceed 29 dB. For power and super-power instruments, the equivalent input noise level measured according to these procedures shall not exceed 32 dB.
-
Contractors shall have a range of hearing aids in each group appropriate for mild, moderate, and severe hearing losses. See definition list for definitions of mild, moderate, and severe.
-
Contractors shall have a minimum of one (1) model in each group which has a matrix at or above an MPO of 125 dB SPL and maximum gain of 60 dB SPL.
Attachments/Links
Contact Information
Contracting Office Address
-
701 MARKET DRIVE
-
OKLAHOMA CITY , OK 73114
-
USA
Secondary Point of Contact
History
-
Dec 03, 2025 05:59 am CSTSources Sought (Original)
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.