Troup County Board of Commissioners
Fire Station #9 – Interior Buildout - RFP (5/1/2026)
103 Railroad Street (Mountville Community), LaGrange, Ga 30240
Quote/Bid Proposal – Fire Station #9 – Interior Buildout (Scope of Work):
• General Contractor shall be licensed and insured with the State of Georgia.
• Provide and install all required/necessary materials, supplies, labor, equipment, machinery, etc.
for the construction project, per the scope of work.
• Submit a detailed project proposal to include the following: proposed construction drawings,
proposed construction specifications, proposed construction schedule, a copy of all manufacturers’
product warranties, and the contractors’ warranty covering all labor, installation and workmanship.
• Submit a final set of detailed construction drawings for review and approval, prior to construction.
• Submit a final set of construction specifications, materials and product information for review and
approval, prior to construction.
• Troup County (Owner) will obtain all required Permits.
• Troup County (Owner) will pay for all required Permits.
• See attached Site Plan for jobsite location (103 Railroad Street, LaGrange, Ga 3240).
• The existing structure is a pre-engineered (red iron) steel/metal building (40’x80’x14’ tall).
• See attached Floor Plan(s) for the 2 Bedroom / 1 Bathroom Option.
• See attached Floor Plan(s) for the 3 Bedroom / 2 Bathroom Option.
•
• General Contractor shall provide all temporary utilities and facilities during construction.
• All interior wood framing (walls & ceilings) shall be 16” o.c. (walls = 2x4, ceilings = 2x10).
• Ceiling height = 9’ AFF.
• Provide and install ¾” floor decking in the entire attic space (for storage) above the living areas.
• Provide and install one (1) pull-down attic access stair (location TBD).
• Insulation: R-13 fiberglass battens in all interior framed walls. R-30 fiberglass battens in the ceilings
of the living areas. Caulk/foam as required by the National Energy Code and the local Building
Official having jurisdiction over the project.
• Sheetrock walls and ceilings (1/2”, smooth finished).
• Interior trim (4 ¼” baseboards, 3” window & door casings).
• Interior doors (3/0 smooth hollow core for ADA Accessibility).
• Interior painting (prime plus two coats of semi-gloss satin latex paint, colors to be selected by
owner).
• Lockout hardware (Schlage, brushed chrome, lever handle sets for ADA Accessibility).
• LVP floor coverings at all rooms (allowance = $10.00 / sq ft installed, materials & labor).
• Kitchen cabinets and bathroom vanities (base cabinets & wall cabinets) per the plan.
• Kitchen cabinets and bathroom vanities shall include plywood boxes with real wood (painted)
front-faced frames, doors, and drawers (no particle board).
• Kitchen countertops (w/ 4” backsplash) and bathroom vanity countertops (with 4” backsplash) shall
be 3cm granite (color = black pearl).
• Kitchen shall include a stainless-steel double bowl kitchen sink with Moen brushed chrome kitchen
faucet, handheld sprayer, and garbage disposal.
• Provide and install kitchen appliances (allowance = $4,000.00) to include: 30” electric range oven,
30” microwave vent hood, 24” dishwasher, 36” refrigerator (with waterline & ice maker).
• 200-amp electrical overhead service and panel.
• Electrical/Lighting layout and LED light fixtures per the plans.
• Troup County (Owner) will provide the low voltage data/cabling/networking/communications.
• Provide and install electric HVAC / Heat Pump unit (provide manufacturer & size & efficiency
rating), located in attic.
• Bathroom venting per the plans & IBC.
• 50-gallon electric water heater located in the attic.
• Plumbing layout and plumbing fixtures (Moen faucets – brushed chrome) per the plans.
• Toilet(s) shall be ADA compliant.
• Bathroom(s) shower stall(s) (36”x42”) shall be ceramic tile (floors & walls) with the appropriate
membrane and waterproofing.
• Provide and install washer & dryer hook-ups (exhaust venting included) on the rear exterior wall of
the apparatus bay area (location TBD).
• Re-install exterior hose bibs, per the existing plumbing layout.
• Fire Life Safety Requirements (hard wired with battery backup): Exit Combo Lights at all exterior
doors (+5), Emergency (bug eye) Lights at all other rooms (+7), Fire Extinguisher & Wall Mounted
Cabinets (+3), and Interconnected Smoke Detectors with Strobes (audio-visual) at all rooms (+4).
• Dormitory / living area shall be separated from the apparatus bay by a 1-hour fire rated wall
assembly (2 layers of 5/8” x-rock covered with 26-gauge white metal walls panels with associated
trim) (two access doors assemblies shall be 1-hour fire rated).
• The inside walls of the apparatus bay shall be framed, covered with ½” OSB, and covered with
white metal walls panels with associated trim (8’ tall).
• Provide and install all lockout & door hardware (brushed chrome).
• Provide and install all required bathroom accessories (brushed chrome).
• Troup County (Owner) will provide all utilities (pre-existing) to the jobsite.
•
• All work shall be coordinated with Troup County Staff.
• Comply with all applicable Building Codes, National Electric Codes, National Energy Codes, Fire Life
Safety Codes, and ADA Handicap Accessibility Codes.
• Provide a copy of all manufacturers’ product warranties and the contractor’s written warranty
covering all labor, installation, and workmanship.
• Clean-up & dispose of all construction debris and/or trash, according to Local/State/Federal
regulations.
• Protect surrounding areas from damage & debris.
• Submit a Quote/Bid Proposal to include all required/necessary materials, supplies, labor,
equipment, machinery, etc. for the complete construction project, per the scope of work.