Percutaneous Coronary Intervention (PCI) Intra - Aortic Balloon Pumps
| Location: |
Texas |
| Posted: |
May 13, 2026 |
| Due: |
May 20, 2026 |
| Agency: |
DEPT OF DEFENSE |
| Type of Government: |
Federal |
| Category: |
- 65 - Medical, Dental, and Veterinary Equipment and Supplies
|
| Solicitation No: |
W81K0026QA153 |
| Publication URL: |
To access bid details, please log in. |
Percutaneous Coronary Intervention (PCI) Intra - Aortic Balloon Pumps
Active
Contract Opportunity
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE ARMY
Major Command
US ARMY MEDICAL COMMAND
Sub Command
US ARMY HEALTH CONTRACTING ACTIVITY
Office
W40M MRC0 WEST
Looking for contract opportunity help?
General Information
-
Contract Opportunity Type: Solicitation (Original)
-
Original Published Date: May 13, 2026 08:44 am MDT
-
Original Date Offers Due: May 20, 2026 05:00 am MDT
-
Inactive Policy: 15 days after date offers due
-
Original Inactive Date:
Jun 04, 2026
-
Initiative:
Classification
-
Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
-
Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
-
NAICS Code:
-
339112 - Surgical and Medical Instrument Manufacturing
-
Place of Performance:
Fort Bliss
,
TX
79918
USA
Description
Percutaneous Coronary Intervention (PCI) / Two (2) Intra - Aortic Balloon Circulatory Assist Units. The Department of Cardiology at William Beaumont Army Medical Center (WBAMC) requires two Intra-Aortic Balloon Circulatory Assist Units to perform any cardiovascular procedure that requires a readily available mechanical support device. This equipment uses a balloon catheter placed in the aorta to improve heart function/flow and helps the heart pump more blood. WBAMC CATH LAB historically performs approximately 6 high-risk Percutaneous Coronary Intervention (PCI) cases at WBAMC per month that require a mechanical support device like the Intra-Aortic Balloon Pump (IABP). See attached solicitation.
1. ESSENTIAL CHARACTERISTICS:
-
Seller must provide system that has been approved by the Food and Drug Administration (FDA) and must not have any unresolved FDA recalls.
-
Seller shall provide the most current system.
-
System must be portable stand-alone device.
-
Application must be for adults use only.
-
System mode of operation must have automatic and manual capabilities.
-
System display must have high resolution, color touch screen monitor with screen size up to 14” with parameters readings for three trace, Electrocardiogram (ECG), arterial pressure, balloon pressure, trigger mode, operational mode, assisted and unassisted pressure values.
-
System must have balloon volume adjustment with increments of 0.5cc.
-
System must have timing adjustment increments of 1 second.
-
System must have signal outputs of ECG, Arterial pressure, fluid filled transducer, fiberoptic sensor.
-
System must have the capabilities of auto condensation removal without interruption.
-
System must alarm notifications for trigger loss, vacuum pressure loss, balloon disconnect, balloon leak, balloon overinflate, systolic inflate, loading failure, high pressure, power loss, device malfunctions, low battery indicator and temporary alarm silencing by end-user.
-
System must have multiple disposable and refillable helium cylinders
-
System must have backup batteries capabilities.
-
System must have print capabilities.
-
System must maintain a history log of past 50 (minimum) to 100 (maximum) alarms.
-
System must have a maximum pump rate of 200 beats per minute.
-
Seller shall provide two copies of operator/user manual.
-
Seller must be an authorized dealer, distributor, or reseller for the proposed system.
-
Seller must provide a warranty for the system in accordance with Original Equipment Manufacturer (OEM).
-
Seller must provide the initial Test, Measurement, and Diagnostic Equipment (TMDE) equipment to service the Intra-Aortic Balloon Circulatory Assist Units.
2. TRAINING:
-
Onsite clinical staff training at William Beaumont Army Medical Center and morning and afternoon classes shall be conducted at the prescribed date and time.
-
Upon completion of training, the contractor shall provide a signed attendance roster.
-
The training required is proper IABP placement and monitoring, troubleshooting techniques, patient care specific to IABP use, and hands on practice with the IABP console.
-
Onsite training for two clinical engineers. For offsite training, tuition only.
3. INSTALLATION:
-
Seller shall contact the Healthcare Technology Management section at 915-569-1042 to arrange for installation of system five business days from award of contract. The installer shall be an authorized Original Equipment Manufacturer (OEM).
-
Installer is responsible for the providing the tools, equipment, and material required to complete installation, removal and disposal of all trash and material in site identified disposal container.
-
Post access: To gain post access employee/installer of company must provide signed memorandum on company letterhead as to their reason for required access with proper identification at the Chaffee Visitor Control Center, building 2616, 2527 Chaffee Rd., Ft. Bliss Texas 79916, Monday through Fridays (closed Federal Holidays) and Buffalo Soldier Visitor Control Center, Building 5400, Ft. Bliss, Texas 79916 on weekends.
-
Hospital Access: Installers must check-in at the WBAMC Provost Marshall Office, building 18511 Highlander Medic St, El Paso, Texas 79906, 1st Floor, room HB1717, Monday through Friday 07:30 to 15:30 (closed Federal Holidays).
-
Safety: Will be required to obtain safety brief from the WBAMC Safety Office. Must provide a copy of company safety program.
4. DELIVERY REQUIREMENTS:
-
Delivery of equipment no later than 45 calendar days from award of contract.
-
The seller shall ensure the package is appropriately marked with the contract number, delivery address, and contracting officer representative information—no partial delivery is authorized.
-
Seller Shall notify contracting officer representative three business days before delivery to include providing tracking information.
-
Delivery during business hours from 08:00 to 15:00 hours MST, Monday through Friday except Federal Holidays.
-
Seller is responsible for providing proper tools and equipment for offloading and inside delivery to required location.
Attachments/Links
Contact Information
Contracting Office Address
-
MEDICAL READINESS CONTR OFFICE WEST 3160 MCINDOE BLDG1103
-
JBSA FT SAM HOUSTON , TX 78234-4504
-
USA
Secondary Point of Contact
History
-
May 13, 2026 08:44 am MDTSolicitation (Original)
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
See also
..., Monitoring, Maintenance, Repair Summary: Security Alarm Installation, Monitoring, Maintenance, and Repair...) Status: ...
City of Austin
Bid Due: 6/02/2026
...Follow Follow-On for Alarm Monitoring Services at Fort Hood, TX Active Contract Opportunity ...
DEPT OF DEFENSE
Bid Due: 6/02/2026
...EXTINGUISHER, SPRINKLER, AND MULTI ALARM INSPECTIONS AND MONITORING WITH SERVICES " RETURN SEALED: ...
City of Huntsville
Bid Due: 6/18/2026
...Bid NO. 26-24 Fire Extinguisher, Sprinkler, and Multi Alarm Inspections and Monitoring...
State Government of Texas
Bid Due: 6/18/2026
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.