6525--sources sought scope repair

Location: Federal
Posted: Nov 18, 2024
Due: Nov 20, 2024
Agency: VETERANS AFFAIRS, DEPARTMENT OF
Type of Government: Federal
Category:
  • 65 - Medical, Dental, and Veterinary Equipment and Supplies
Solicitation No: 36C25025Q0126
Publication URL: To access bid details, please log in.
Follow
6525--sources sought scope repair
Active
Contract Opportunity
Notice ID
36C25025Q0126
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
250-NETWORK CONTRACT OFFICE 10 (36C250)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • Original Published Date: Nov 18, 2024 04:30 pm EST
  • Original Response Date: Nov 20, 2024 10:00 am EST
  • Inactive Policy: Manual
  • Original Inactive Date: Nov 21, 2024
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: 6525 - IMAGING EQUIPMENT AND SUPPLIES: MEDICAL, DENTAL, VETERINARY
  • NAICS Code:
    • 811210 - Electronic and Precision Equipment Repair and Maintenance
  • Place of Performance:
    SEE SOW ,
    USA
Description
This is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of the market s offered products, services and capabilities. The Government will not pay any costs for responses submitted in response to this Sources Sought.
The Dayton, OH VAMC requires that all endoscopic equipment be maintained in accordance with the original equipment manufacturer (OEM) specifications. This equipment will be covered under a service agreement.

The NAICS Code for this acquisition is 811210, size standard of $34 Million. The product service code is J065. The contracting office is contemplating award of a Firm-Fixed-Price contract for this service.

This Sources Sought notice provides an opportunity for respondents to submit their notice of ability, and their available services in response to the requirement described below. Vendors are being invited to submit information relative to their potential of fulfilling the requirement below, in the form of a capability response that addresses the specific requirement identified in this Sources Sought. Pursuant to FAR Part 10, Market Research, the purpose of this notice is to determine if sources capable of satisfying the agency's requirements exists and to determine the commercial practices of company's engaged in providing the needed service. Pursuant to FAR Part 6 and FAR Part 19, competition and set-aside decisions may be based on the results of this market research. This notice in no way obligates the Government to any further action.

GENERAL REQUIREMENTS
Contractors that can provide and meet the requirement are requested to send:

1. Company Name
2. SAM.gov UEI number
3. Business size under NAICS 811210
4. If you believe another NAICS code is more suitable for these services, please include the code.
5. If the service(s) are available on an FSS contract or not and the FSS contract number if it is available on contract.
6. Notification if they are an SBA VetCert registered VOSB/SDVOSB or not. Contractors must be registered and certified in VetCert to be considered VOSB/SDVOSB.
7. Is there any reason you would not be interested in responding to a solicitation?
8. Please provide a short narrative on the technical capability and interest in providing the requested services.
9. Any questions, comments, or concerns, that may otherwise assist us.
10. Does your company have the ability to perform this contract while complying with the Limitations on Subcontracting rules per FAR 52.219-14, 13 CFR 125.6 and VAAR 852.219-75. If so, please briefly explain how your firm will accomplish this, include any potential teaming arrangements or subcontractors.

To Note: The CO shall conduct periodic checks with the vendor to ensure that Limitations on Subcontracting compliance is maintained during the period of performance if this requirement is set-aside for any small business entities. In accordance with 13 CFR § 125.6(g), Whoever violates the requirements set forth in paragraph (a) of this section shall be subject to the penalties prescribed in 15 U.S.C. 645(d), except that the fine shall be treated as the greater of $500,000 or the dollar amount spent, in excess of permitted levels, by the entity on subcontractors. A party's failure to comply with the spirit and intent of a subcontract with a similarly situated entity may be considered a basis for debarment on the grounds, including but not limited to, that the parties have violated the terms of a government contract or subcontract pursuant to far 9.406-2(b)(1)(i) (48 CFR 9.406-2(b)(1)(i)
RESPONSE COMMITMENT
Response:
All responses should be directed to Brandi.Holland2@va.gov (NO PHONE CALLS WILL BE RESPONDED TO OR MADE)
Submittals furnished will not be returned to the sender. No debriefs will be conducted. Eligibility in participating in a future acquisition does not depend upon a response to this notice.
Proprietary information is neither requested nor desired. If such information is submitted, it must clearly be marked "proprietary" on every sheet containing such information, and the proprietary information must be segregated to the maximum extent practicable from other portions of the response (e.g., use an attachment or exhibit).

Timeline:
This request will close on stated date within the Government Point of Entry (GPE).
PERFORMANCE WORK STATEMENT (PWS)

Contract Number:
TBD
Task Order Number:
TBD
IFCAP Tracking Number:
TBD
Follow-on to Contract and Task Order Number:
TBD

Contracting Officer s Representative (COR):

Name:
TBD
Section:
TBD
Address:
TBD
Phone Number:
TBD
E-Mail Address:
TBD

Contract Title: Scope Repair Service Contract

Background: The Dayton VA sends out of scope repairs a couple times a month and when scope repairs are over $10,000, it results is the creation of individual contracts. We want to create an IDIQ scope contract for expedition of scope repairs.

Scope: When a scope needs repaired, we will contact the vendor to come pick up the scope(s). They will research to figure out if a scope is still under warranty or not and if they can do the repair or if it needs to be sent to the original equipment manufacture (OEM).

Specific Tasks:

A. The contractor shall provide maintenance, support, and repair services for flexible endoscopes, rigid endoscopes, surgical cameras, and surgical equipment, including all models of equipment listed below, in accordance with OEM specifications. The contractor shall identify unsafe and non-repairable items for removal from service. The contractor shall provide travel, parts, and labor to complete all services covered under this agreement. All parts must be new and certified to OEM specifications.

Manufacturer
Model
Quantity
(Estimated)
Karl Storz
10005AA
1
Karl Storz
10320A
2
Karl Storz
10320B
2
Karl Storz
109738D
3
Karl Storz
22210131-3
1
Karl Storz
22210140-3
1
Karl Storz
22220054-3
1
Karl Storz
26003AA
2
Karl Storz
26003ARA
6
Karl Storz
26003BA
2
Karl Storz
26003BRA
4
Karl Storz
26046AA
2
Karl Storz
26046ARA
6
Karl Storz
26046BA
2
Karl Storz
26046BRA
4
Karl Storz
27005AA
1
Karl Storz
27005B
2
Karl Storz
27005BA
5
Karl Storz
28731BWA
10
Karl Storz
28731CWA
2
Karl Storz
7220AA
1
Karl Storz
7220BA
1
Karl Storz
7220CA
1
Karl Storz
7230AA
2
Karl Storz
7230BA
2
Karl Storz
7230CA
3
Karl Storz
TH104
1
Karl Storz
TH120
4
Karl Storz
TH121
4
KayPENTAX
FNL-10RP3
11
Olympus America Inc.
A22001A
3
Olympus America Inc.
A22002A
4
Olympus America Inc.
A2948A
1
Olympus America Inc.
ACN-2
1
Olympus America Inc.
BF-UC180F
3
Olympus America Inc.
CYF-5
5
Olympus America Inc.
CYF-VH
7
Olympus America Inc.
DUR-8ULTRA
1
Olympus America Inc.
ENF-GP
1
Olympus America Inc.
EVIS EXERA II CF-2T160L
1
Olympus America Inc.
EVIS EXERA II CF-Q180AL
1
Olympus America Inc.
EVIS EXERA II GIF-2TH180
1
Olympus America Inc.
EVIS EXERA II GIF-Q180
1
Olympus America Inc.
EVIS EXERA III BF-1TH190
1
Olympus America Inc.
EVIS EXERA III BF-H190
5
Olympus America Inc.
EVIS EXERA III BF-P190
1
Olympus America Inc.
EVIS EXERA III CF-HQ190I
1
Olympus America Inc.
EVIS EXERA III CF-HQ190L
4
Olympus America Inc.
EVIS EXERA III GIF-H190
7
Olympus America Inc.
EVIS EXERA III GIF-XP190N
1
Olympus America Inc.
EVIS EXERA III PCF-HQ190L
2
Olympus America Inc.
EVIS EXERA III TJF-Q190V
1
Olympus America Inc.
HD ENDOEYE LTF-S190-5
1
Olympus America Inc.
LF-V
2
Olympus America Inc.
OES WA02946A
8
Olympus America Inc.
PCF-PH190L
1
Olympus America Inc.
URF-P7R
7
Olympus America Inc.
WA2T412A
5
Olympus America Inc.
WA2T430A
5
Olympus America Inc.
WA2T470A
5
Olympus America Inc.
WA2UR12A
4
Olympus America Inc.
WA2UR13A
4
PENTAX Medical Co
VLS-1070STK
1
PENTAX Medical Co
VLS-1190STK
1
PENTAX Medical Co
VNL11-J10
4
PENTAX Medical Co
VNL15-J10
2
STRYKER CORPORATION
502-539-010
4
STRYKER CORPORATION
502-859-010
5
Verathon Inc
GLIDESCOPE AVL 0570
2
Verathon Inc
GLIDESCOPE CORE
19
Verathon Inc
GLIDESCOPE GO
2
B. The contractor shall be onsite within 3 hours for emergency scope repairs. The contractor shall be onsite within 24 hours for non-emergency scope repairs.

C. The contractor shall inspect equipment and provide an estimate within 48 hours of receipt according to standard business hours.

D. The contractor will identify scopes that are on a trade-in agreement with the OEM when applicable and will swap them out.

D. The contractor shall notify the VA Biomedical point of contact if the scope cannot be repaired, or if it will be returned for an OEM repair, no later than 48 hours of receipt according to standard business hours.

E. The contractor shall provide an average turnaround time of 10 business days.

F. The contractor will supply the Dayton VA Medical Center HTM department with a copy of a detailed service report upon the return/delivery of the equipment.

G. A documentation package acceptable for Joint Commission or any regulatory purposes shall be maintained by the contractor and made available to the government upon request. Documentation shall be provided upon request for all work performed for a particular date or period, and shall include repair spend, repair detail by item, turnaround time, and reason for repair.

H. The contractor shall provide the necessary manpower and supervision to properly execute corrective maintenance. The contractor shall furnish all tools and material required. The contractor shall furnish new, any required parts, supplies, or PM kits needed to perform maintenance.

I. The contractor shall include a structured price/cost schedule. Based on prior repairs performed, the contractor shall be able to identify those repairs and associated costs that are most common. The contractor shall provide a contracted firm fixed price for each of these using a Contract Line-Item Number (CLIN) format. The contractor will perform repairs at these contracted firm fixed prices. For any inspections performed that identify a repair action that is not provided, the contractor shall notify the Administrative Contracting Officer (ACO) and other government parties as requested by the ACO. The notification shall include the results of the inspection as well as an estimated cost to repair. The contractor shall also address situations concerning costs where the repair is not performed by the contractor. Unless the contract is modified, repairs performed outside the identified/listed common types shown in the proposed cost/fee schedule will not be charged to this contract.

J. The contractor shall invoice on a per scope basis for repair services rendered.

K. Next day return shipping on all scopes shall be provided by the contractor at no additional charge to the government.

L. The contractor shall use commercially reasonable efforts to provide service as quickly as possible and on a priority basis for emergencies. The contractor shall ensure prompt communication with the Contracting Officer s Representative or designee.

Performance Monitoring: The contractor shall communicate with a representative of HTM on status of scope repairs.

Security Requirements: The Contractor shall be required to report to Healthcare Technology Management to log in. This check in is mandatory. When the service is completed, the Field Service Engineer (FSE) shall document services rendered on a legible Service Report(s). The FSE shall be required to log out with Healthcare Technology Management and submit the Service report(s) to Healthcare Technology Management. ALL service reports shall be submitted to the equipment user for an "acceptance signature" and to Healthcare Technology Management for an "authorization signature . Service report shall describe the work that was completed and list parts that were replaced. A copy of the service report shall be signed and left with a representative of Healthcare Technology Management prior to the departure of the service person.

The C&A requirements do not apple and a Security Accreditation Package is not required.

Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI): None

Other Pertinent Information or Special Considerations: N/A

Risk Control: N/A

Place of Performance: Dayton VA Medical Center, 4100 W Third St, Bldg 322 Rm 1, Dayton, OH. 45428

Period of Performance: The contract shall be a base year with 4 option years

Delivery Schedule: N/A

14) Changes to Statement of Work:
Any changes to this SOW shall be authorized and approved only through written correspondence from the CO. A copy of each change will be kept in a project folder along with all other products of the project. Costs incurred by the contractor through the actions of parties other than the CO shall be borne by the contractor.
Attachments/Links
Contact Information
Contracting Office Address
  • VISN 10 CONSOLIDATED CONTRACTING 4100 WEST 3RD STREET
  • DAYTON , OH 45428
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Nov 18, 2024 04:30 pm ESTSources Sought (Original)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...Follow 6515--GNV IMAGING INSUFFLATORS 36C24826Q0763 Active Contract Opportunity Notice ID... AND SURGICAL INSTRUMENTS, ...

VETERANS AFFAIRS, DEPARTMENT OF

Bid Due: 6/17/2026

...Follow Z2DB--Renovate Imaging and Catheterization Lab 570 21 220 Fresno VA Medical Center ...

VETERANS AFFAIRS, DEPARTMENT OF

Bid Due: 6/29/2026

...SIGHTING AND RANGING EQUIPMENT NAICS Code: 334511 - Search, Detection, Navigation, Guidance, Aeronautical... ...

DEPT OF DEFENSE

Bid Due: 6/30/2026

...used Product Service Code: 1240 - OPTICAL SIGHTING AND RANGING EQUIPMENT NAICS Code: ...

DEPT OF DEFENSE

Bid Due: 6/30/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.