6515--36C25525Q0318 | INFRARED OVEN

Location: Kansas
Posted: Apr 16, 2025
Due: Apr 27, 2025
Agency: VETERANS AFFAIRS, DEPARTMENT OF
Type of Government: Federal
Category:
  • 65 - Medical, Dental, and Veterinary Equipment and Supplies
Solicitation No: 36C25525Q0318
Publication URL: To access bid details, please log in.
Follow
6515--36C25525Q0318 | INFRARED OVEN
Active
Contract Opportunity
Notice ID
36C25525Q0318
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
255-NETWORK CONTRACT OFFICE 15 (36C255)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
  • Original Published Date: Apr 16, 2025 03:21 pm CDT
  • Original Date Offers Due: Apr 27, 2025 11:00 pm CDT
  • Inactive Policy: Manual
  • Original Inactive Date: May 12, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
  • Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
  • NAICS Code:
    • 333994 - Industrial Process Furnace and Oven Manufacturing
  • Place of Performance:
    Robert J. Dole Medical Facility Building 34 NX Warehouse Wichita , KS 67218
    USA
Description
STATEMENT OF WORK (SOW)
*ALL ITEMS HEREIN THAT MENTION BRAND NAME PRODUCTS MAY BE SUBSTITUTED FOR A LIKE OR SIMILAR ITEM*

1. INTRODUCTION
This solicitation is to provide the Veterans Health Administration, Robert J. Dole VA with one (1) Infrared Oven for use in the Robert J Dole VAMC Prosthetics Laboratory. This Infrared oven is needed to be able to heat plastics to fabricate prosthetic limp components for Veterans receiving prosthetic services.
2. BACKGROUND
The Wichita VAMC currently uses a HIX CORP Infrared Oven to heat plastics to form prosthetic limb components for test sockets. The current oven was acquired in 1983, is beyond its current life cycle, and due for replacement. The new oven will provide the prosthetist with updated features to allow for more efficient heating and increasing safety to clinician with rotating cart feature not on current oven. The new oven will allow our Prosthetist to create test sockets efficiently, reducing heating time up to 10 minutes per socket, as well as reducing energy consumption. The sensor on the new oven will measure material sag and alert clinician that material is ready to be formed, reducing opportunity for human error regarding time management with multitasking. The mobile cart facilitated switching between the Teflon covered work surface and vacuum forming frame quickly saving space and reducing potential for harm (clinician does not have to carry hot plastic to new station).
3. SCOPE OF WORK
The contractor shall furnish and deliver IR Oven Turn W. Sensor (701E40=S US) within 8 weeks from purchase. Contractor shall provide standard 2-year warranty from date of delivery.
4. TECHNICAL REQUIREMENTS
A. Salient Features for 701E40=S US Infrared oven with rotatable material cart and sensor.
Sensor for exact measurement of the material sag depth with acoustic and optical signal.
Mobile material cart with rotation function facilitations switching between Teflon-covered work surface and vacuum forming frame quickly and saves space
State-of-the-art infrared quartz tubes with single reflectors ensure an even heating.
Optical temperature sensor permits continuous monitoring of the material surface temperature.
Simple operation via a central element with temperature setpoint entry and timer function.
Storage function for user-defined heating processes
Graphical progress indicator for monitoring.
Heat insulated housing, enclosed on all sides
Space saving sliding door.
Stainless steel front panel with 3 viewing windows.

B. Technical Requirements:
Equipment: Opto-electric Infrared Oven measuring head for measuring the surface temperature. PID controller, temperature continuously adjustable from 30 C to 250 C. Temperature indicator with setpoint and actual value and programmable timer function. SPS controller with touch panel.
Material Cart: With rotation function for switching between sheet materials and vacuum formed sockets. Mobile with 4 castors with brakes. Usable area on material cart W x D 1,260 mm x 1,040 mm. Working Height 1,080 mm.
Dimensions W x D x H: 1,600 mm x 1,270 mm x 1,430 mm
Material: Steel, stainless steel
Electrical Connection: 3 x 400 V N/PE/50-60Hz/8.5 kW
Power cord: 4 m power cord with CEE plug 5 x 16 A and CEE socket 5 x 18A
Infrared heating element: Panel heating via 18 infrared quartz tubes with single reflectors ensures the material is heated evenly.
5. DELIVERY & LOCATION INFORMATION
Delivery of IR Oven Turn, W. Sensor (701E40=S US) will be provided to:
Robert J. Dole Medical Facility
Building 34 NX Warehouse
5500 East Kellogg
Wichita Kansas, 67218

6. SECURITY REQUIREMENTS
7. PERIOD OF PERFORMANCE
8. WORK HOURS
9. ROBERT J. DOLE POINT OF CONTACT
10. INSTALLATION AND CLEANUP
11. TRAINING
12. WARRANTY AND MAINTENANCE SERVICE
Attachments/Links
Contact Information
Contracting Office Address
  • VA MEDICAL CENTER 4101 SOUTH 4TH STREET
  • LEAVENWORTH , KS 66048
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Apr 16, 2025 03:21 pm CDTCombined Synopsis/Solicitation (Original)

Related Document

Apr 16, 2025[Solicitation (Original)] 36C25525Q0318 - INFRARED OVEN
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.