BEDFORD TOWNSHIP FIRE DEPARTMENT
May 26, 2026
RE: REQUEST FOR SEALED BIDS
Fire Training Tower Repair and Maintenance Project
The Bedford Township Fire Department is soliciting sealed bids from qualified contractors for the repair,
rehabilitation, and maintenance of the live fire training tower located at 8100 Jackman Road,
Temperance, Michigan 48182.
The project is based upon deficiencies and recommendations identified during a recent five-year
structural and operational inspection completed by Rimkus Consulting Group in accordance with NFPA
1400 requirements for live fire training structures. The inspection report dated May 8, 2026, is attached
and shall be considered part of these bid specifications.
The training tower is a three-story live fire training structure containing two non-gas-fired burn rooms
utilizing Westemp insulation panel systems. Contractors submitting proposals shall review the attached
inspection report in its entirety and provide a comprehensive proposal addressing all identified repair
and maintenance items.
At a minimum, all proposals shall include the following:
• Detailed cost estimates for all recommended repairs and maintenance items
• Estimated timeline for project completion following contract execution
• Estimated lead times for procurement of materials and scheduling
• Applicable warranty information for labor and materials
• Contractor qualifications and documented experience with live fire training structures, burn
buildings, or similar specialized facilities
• Identification of any subcontractors proposed for use on the project
• Proof of appropriate licensing and insurance coverage
Attention shall be given to the following HIGH-PRIORITY items, which must be completed before the
structure may be returned to service:
• Removal and replacement of damaged, cracked, and failed Westemp insulation panels in both
burn rooms
• Removal and replacement of the pyrometers and data logging system in both burn rooms
Additional medium- and low-priority deficiencies identified within the inspection report shall also be
included in the proposal and separated by category and priority level.
Contractors are encouraged to conduct a site visit prior to submission of bids. Site visits may be
scheduled by contacting the Bedford Township Fire Department.
All work shall comply with applicable NFPA standards, manufacturer specifications, OSHA regulations,
state and local codes, and industry best practices for live fire training facilities.
The Bedford Township Board reserves the right to reject any or all bids, waive informalities or
irregularities in the bidding process, and accept the proposal deemed to be in the best interest of the
Township.
Sealed bids shall be clearly marked:
“SEALED BID – FIRE TRAINING TOWER REPAIRS”
and delivered to:
Bedford Township Clerk’s Department
8100 Jackman Rd,
Temperance, MI 48182
Bids must be received no later than June 12, 2026, by 4:00 P.M.
Bids will not be opened at the time of the deadline. Bids will be open at the discretion of the Clerk,
when time allows. Results will be posted on the township website www.bedfordmi.com
Questions regarding this request may be directed to:
Fire Chief Bob Vanklingeren
Bedford Township Fire Department
Phone: 734-224-7312
Email: Bvanklingeren@bedfordmi.org
Thank you for your interest in this project. We appreciate your time and consideration and look forward
to reviewing your proposal.
100 West Big Beaver Road, Suite 200
Troy, MI 48084
(941) 727-2600
Report of Findings
Fire Training Tower, 5-Year Tower Inspection
8100 Jackman Road, Temperance, MI
Rimkus Matter No: 100336464
Prepared For:
Fire Facilities, Inc.
314 Wilburn Road
Sun Prairie, WI 53590
Attention:
Ms. Shelly Mertig
Digitally signed by: DERECK J HODSON
Date: 2026.05.08 15:46:49 -06'00'
Dereck J. Hodson, P.E.
Engineering Number P.E. 6201313043
Senior Consultant
Craig M. Dudas
Craig M. Dudas, R.S.
Reserve Specialist #215
Senior Practice Leader Construction Advisory
May 8, 2026
TABLE OF CONTENTS
I. General Information/Scope of Services
1
II. Tower Description
4
III. Background Information
5
IV. Observations
7
General Observations Visual
Structural Observations Visual
Non-Structural Observations
V. Summary
11
VI. Basis of Report
12
VII. Attachments
13
A. Photographs
B. Service Bulletin
C. Paint and Care Maintenance Manual
D. Curriculum Vitae
May 8, 2026
Section I
GENERAL INFORMATION/SCOPE OF SERVICES
Rimkus has conducted this visual structural evaluation to assess the structural integrity
of the fire training tower and make recommendations. National Fire Protection Association
(NFPA) 1400 (2026 Edition) Section 8.2 requires that the structural integrity of the live fire
training structure be evaluated and documented annually by the building owner, operator,
or Authority Having Jurisdiction (AHJ). If visible structural defects are found, such as but
not limited to cracks, rust, spalls, or warps in structural floors, columns, beams, walls, or
metal panels, the owner/operator shall have a follow-up evaluation conducted by a
licensed professional engineer with live fire training structure experience and expertise.
Follow-up Inspection Program
The follow-up inspection program complies with NFPA 1400 section 8.2.1.1 and will
include the following, if applicable:
Complete service carried out by a licensed professional engineer with live fire
training structure experience and expertise.
Visual inspection of the exposed areas of the foundation and slab.
Visual inspection of the exterior of the tower.
Visual inspection of all exposed structural elements.
Visual inspection of all thermal linings.
Visual inspection of all doors and window shutters, including hardware.
Visual inspection of stairs, ladders, and fire escapes.
Recommendations for repairs, maintenance, or improvements.
A formal report with photographs documenting the findings.
Non-Gas-Fired/5-Year Inspection Program
May 8, 2026 | Rimkus Matter No. 100336464
1
This is the opportunity summary page. It provides an overview of this opportunity and a preview of the attached documentation.
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...Description: Captive Financial Examinations of Insurance Companies Department: Insurance... and Financial Services Buyer: ...

State of Michigan

Bid Due: 6/22/2026

...Description: Captive Actuarial Examinations of Insurance Companies Department: Insurance... and Financial Services Buyer: ...

State of Michigan

Bid Due: 6/15/2026

...Description: Captive Actuarial Examinations of Insurance Companies Department: Insurance... and Financial Services Buyer: ...

State of Michigan

Bid Due: 6/15/2026

...Description: Captive Financial Examinations of Insurance Companies Department: Insurance... and Financial Services Buyer: ...

State of Michigan

Bid Due: 6/22/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.