Troup County Board of Commissioners
Fire Station #9 – Demolition & New Exterior Metal Shell - RFP (5/1/2026)
103 Railroad Street (Mountville Community), LaGrange, Ga 30240
Quote/Bid Proposal – Fire Station #9 - Demolition & New Exterior Metal Shell (Scope of Work):
• General Contractor shall be licensed and insured with the State of Georgia.
• Provide and install all required/necessary materials, supplies, labor, equipment, machinery, etc.
for the project, per the scope of work.
• Submit a detailed project proposal to include the following: proposed construction drawings,
proposed construction specifications, proposed construction schedule, a copy of all manufacturers’
product warranties, and the contractors’ warranty covering all labor, installation and workmanship.
• Submit a final set of detailed construction drawings for review and approval, prior to construction.
• Submit a final set of construction specifications, materials and product information for review and
approval, prior to construction.
• Troup County (Owner) will obtain all required Permits.
• Troup County (Owner) will pay for all required Permits.
• See attached Site Plan for jobsite location (103 Railroad Street, LaGrange, Ga 3240).
• The existing structure is a pre-engineered (red iron) steel/metal building (40’ x 80’ x 14’ tall).
• Troup County (Owner) shall disconnect all utilities to the jobsite, prior to the
demolition/construction work.
• Existing monolithic concrete slab foundation shall be protected during demolition/construction
work and remain in place in the current condition for future renovations/use.
• Existing structural steel frame (red iron frame) shall be protected during demolition/construction
work and remain in place in the current condition for future renovations/use.
• Existing plumbing stub-outs (domestic water and/or sanitary sewer) in the monolithic concrete slab
foundation shall be protected during demolition/construction work and remain in place in the
current condition for future renovations/use.
• Existing floor (trough/trench) drain system in the monolithic concrete slab foundation shall be
protected during demolition/construction work and remain in place in the current condition for
future renovations/use.
• All work shall be coordinated with Troup County Staff.
• Comply with all applicable Building Codes, National Electric Codes, National Energy Codes, Fire Life
Safety Codes, and ADA Handicap Accessibility Codes.
• Provide a copy of all manufacturers’ product warranties and the contractor’s written warranty
covering all labor, installation, and workmanship.
• Clean-up & dispose of all demolition and/or construction debris/trash, according to
Local/State/Federal regulations.
• Protect surrounding areas from damage & debris.
• Contractor shall demo/remove all the existing non-structural exterior metal shell (facade) and the
existing non-structural interior finishes, including but not limited to the following items:
▪ Metal roof panels (w/ associated insulation), roof trim, gutters, and downspouts.
▪ Metal wall panels (w/ associated insulation), wall trim, and flashings.
▪ Metal overhead garage doors, door trim, frames, associated track and openers.
▪ Metal exterior doors, door trim, frames, and associated lockout hardware.
▪ Metal exterior windows, window trim, frames, and associated hardware.
▪ Exterior HVAC equipment and exterior overhead electrical service.
▪ Exterior radio antennae.
▪ Interior electrical panels, electrical systems, and lighting systems.
▪ Interior low voltage systems.
▪ Interior partition walls with associated wall coverings and insulation.
▪ Interior ceilings with associated ceiling coverings and insulation.
▪ Interior HVAC systems and bay heaters.
▪ Interior cabinetry, countertops, plumbing fixtures, and appliances.
▪ Interior floor coverings.
▪ All miscellaneous interior finishes.
▪ Etc.
▪
• Contractor shall provide and install all of the new exterior metal shell (façade) and the interior
finishes listed below:
▪ Metal (24 gauge) roof system (NO sky lights), 4” nylon PSK vinyl coated insulation,
associated metal roof trim(s)/flashing(s)/boot(s)/sealants.
▪ Metal (26 gauge) gutters and downspouts.
▪ Metal (26 gauge) wall panels, 4” nylon PSK vinyl coated insulation, associated metal
wall trim(s)/flashing(s)/sealants.
▪ Three (3) exterior metal doors (3/0 x 7/0 outswing with ADA compliant panic
hardware, lockout hardware, closures, flat/flush surface), frames, and associated
metal trim(s). Locations to be determined later with the final interior floor plan.
▪ Three (3) exterior metal windows (3/0 x 5/0), frames, and associated metal trim(s).
Locations to be determined later with the final interior floor plan.
▪ Three (3) metal overhead garage doors (match existing locations) (2000 Series Units)
(12’ x 12’), frames, associated metal trim(s), and associated track/openers.
▪ Metal roof system, trim, gutters, and downspouts shall be Bronze (dark brown).
▪ Metal wall panels, trim, and flashing shall be Tan/Beige.
▪ Metal doors, windows, and trims shall be Bronze (dark brown).
▪
• Submit a Quote/Bid Proposal to include all required/necessary materials, supplies, labor,
equipment, machinery, etc. for the project, per the scope of work.