J041--AC-100 CHW COIL REPLACEMENT/Repairs -Base Only
| Location: |
Federal |
| Posted: |
Mar 10, 2025 |
| Due: |
Mar 17, 2025 |
| Agency: |
VETERANS AFFAIRS, DEPARTMENT OF |
| Type of Government: |
Federal |
| Category: |
- J - Maintenance, Repair, and Rebuilding of Equipment
|
| Solicitation No: |
36C26225Q0622 |
| Publication URL: |
To access bid details, please log in. |
J041--AC-100 CHW COIL REPLACEMENT/Repairs -Base Only
Active
Contract Opportunity
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
262-NETWORK CONTRACT OFFICE 22 (36C262)
Looking for contract opportunity help?
General Information
-
Contract Opportunity Type: Sources Sought (Original)
-
Original Published Date: Mar 10, 2025 04:07 pm MDT
-
Original Response Date: Mar 17, 2025 12:00 pm MDT
-
Inactive Policy: Manual
-
Original Inactive Date:
Apr 16, 2025
-
Initiative:
Classification
Description
This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. It is neither a solicitation
announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this sources sought must be in writing. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Small Businesses interested and capable of providing the services described below. The priority is to find two or more Service-Disabled Veteran Owned Small Businesses (SDVOSB), Veteran-Owned Small Businesses (VOSB).
Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition.
Responses to this notice shall include the following: (a) company name (b) address (c) point of contact (d) phone, fax, and email (e) DUNS number (f) Cage Code (g) Tax ID Number and (h) must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor for the work described below.
CONTRACT REQUIREMENTS
CONTRACT TITLE:
HVAC/Refrigeration System Emergency Repair
PLACE OF PERFORMANCES:
VA San Diego Healthcare System
3350 La Jolla Village Dr.
San Diego, CA 92161
PERIOD OF PERFORMANCE:
Base Year
CONTRACT TYPE:
Firm Fixed Price
BACKGROUND:
Damaged HVAC/Refrigeration System repair required to ensure heating ventilation, exhaust and air conditioning meets VA Patient Care standards.
GENERAL REQUIREMENTS:
The contractor will:
Troubleshoot: Which includes diagnosing, tracing, and locating to identify cause of failure in a manner which minimizes impact to patient care and maintains a safe environment for all.
Repairing:
Arrange time/date repair minimizes impact to patient care.
Perform required lock out/tag-out ensure hazardous energy is removed in preparation of the repair.
Complete repair utilizing materials and parts that meet or exceed all applicable VA requirements/standard.
Remove lock out/tag out in accordance with applicable safety requirements that meets or exceeds VA Requirements/Standards.
Test and commission the system to ensure the repaired system is operating as designed/required to function to meet or exceed VA requirements/standards.
Return the system to operation notifying all applicable units served by the equipment in accordance with all applicable VA requirements/standards.
Provide training to the VA Maintenance or Engineering staff that will operate the repaired equipment.
Provide documentation to include updated as built drawing, parts used and warranty information to enable VA Engineering Maintenance or staff the ability to maintain the system properly following the repair.
Provide SOW for AC -100 CHW Coil:
Replacing existing cooling coil with a replacement coil Factory Designed and Engineered to meet the necessary requirement for the Sterile Processing Department.
Coil rack replacement for existing heating and replacement cooling coils.
Remove and re-installing 60 insulated wall panels and roof.
Cabinet will feature thermal brake construction and a coating that meets a 2000-hour salt spray test.
Attachments/Links
Contact Information
Contracting Office Address
-
335 E. German Rd SUITE 301
-
Gilbert , AZ 85297
-
USA
Secondary Point of Contact
History
-
Mar 10, 2025 04:07 pm MDTSources Sought (Original)
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
See also
...Naval Facilities Engineering System Command (NAVFAC) Mid- Atlantic requirement: The contractor shall... electrician ...
DEPT OF DEFENSE
Bid Due: 7/15/2026
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.