Notice of Intent to Sole Source - Remote Monitoring Units - Cathodic Protection

Location: Federal
Posted: Nov 15, 2024
Due: Nov 25, 2024
Agency: DEPT OF DEFENSE
Type of Government: Federal
Category:
  • C - Architect and Engineering Services - Construction
Solicitation No: FA8903-24-R-0006
Publication URL: To access bid details, please log in.
Follow
Notice of Intent to Sole Source - Remote Monitoring Units - Cathodic Protection
Active
Contract Opportunity
Notice ID
FA8903-24-R-0006
Related Notice
FA8903-24-SS-0300
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE AIR FORCE
Major Command
AIR FORCE MATERIEL COMMAND
Sub Command
AF INSTALLATION & MISSION SUPPORT CENTER
Office
FA8903 772 ESS PK
General Information
  • Contract Opportunity Type: Special Notice (Original)
  • Original Published Date: Nov 15, 2024 03:12 pm CST
  • Original Response Date: Nov 25, 2024 04:00 pm CST
  • Inactive Policy: 15 days after response date
  • Original Inactive Date: Dec 10, 2024
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: C1NA - ARCHITECT AND ENGINEERING- CONSTRUCTION: FUEL SUPPLY FACILITIES
  • NAICS Code:
    • 213112 - Support Activities for Oil and Gas Operations
  • Place of Performance:
    USA
Description

This is notice of intent to solicit to a sole source requirement for which justification has been approved. A sources sought was previously posted at FA8903-24-SS-0300



REQUIREMENT

Provide Prepaid Cellular/Satellite Data Services for Rectifier Remote Monitoring Unit (RMUs) Installed at US Air Force Petroleum Oil Lubricants (POL) Sites on Cathodic Protection (CP) Systems Protecting Fuel Tanks and Pipelines from Corrosion.





Number of units: 381



CODES:

• UFC 3-570-01, CP, 28 November 2016, Change 1, 14 January 2019, Par 4-5.1

• UFC 3-570-06, Operation and Maintenance: CP Systems, para. 4-6.1, 15 July 2019

Remote monitoring can be installed to instantly identify readings that are below or above set points. These remote monitoring systems can monitor rectifier AC input voltage, DC output voltage and current, structure potentials, and many other things such as structure bonds, resistance bonds, test station potentials, and galvanic anode currents. Immediate notification of these problems can greatly accelerate the time required to repair the cause of the alarm. These systems can accelerate the data collection and recordkeeping functions, as well as provide much needed data for effective troubleshooting.



SYNOPSIS:

ELECSYS is a commercial provider of Remote Monitoring Units (RMU) to Major Commercial Customers in the Oil, Gas, Water, and Electrical sectors. Figure 1 shows a typical Air Force CP fuel pipeline protection rectifier being monitored by an ELECSYS Watchdog RMU that uses commercial cellular and satellite communications to collect data and send to the ELECSYS server. The ELECSYS Connect application (Figure 2 Close up of Figure 1) provides the data collection, transfer, storage, analysis of data collected.

The “ELECSYS Connect” provides a Web-based Remote Monitoring and Analysis Application for data collection (through cellular and satellite communication networks) and Web-based analysis of data. The basic capabilities of ELECSY Connect (Appendix A) are:

• Access & Analyze Remote Monitor Data (through ELECSYS RMUs)

• Configure Alarms and Reporting Schedule of Collected Data

• Access through any Web-Enabled Device (Controlled Access by login and/or limited access to RMUs, user selection)

• File and Data Transfer Capabilities

• Graphical and Tabular Data Display Options

• GPS function for Pinpoint Location of RMU



The ELECYS Corporation provides Watchdog Web and Data Security (Appendix B). The “best practices” ELECSYS Corporation employs to assure data security and availability for customers are:

• Authentication and Authorization

• Backups

• Configuration Management

• Firewall/Router Security

• Cryptography

• Data Transmission

• Data Validation

• Error Handling

• File Uploads

• Session Management

• Physical Security

The ELECSYS services listed above are available when the ELECSYS Monthly Fee for each RMU is paid and fee covers both the cellular/satellite communication carrier charges and the ELECSYS server services described above. No additional hardware is required. This contract addresses the monthly fee for each RMU for an entire year of ELECSYS RMU commercial services.


Attachments/Links
Contact Information
Contracting Office Address
  • CP 210 395 8776 2261 HUGHES AVE BLDG 171 STE 163
  • JBSA LACKLAND , TX 78236-9861
  • USA
Primary Point of Contact
Secondary Point of Contact
History
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.