Liquid Chromatography Mass Spectrometer
| Location: |
New York |
| Posted: |
Apr 30, 2026 |
| Due: |
May 15, 2026 |
| Agency: |
DEPT OF DEFENSE |
| Type of Government: |
Federal |
| Category: |
- 66 - Instruments and Laboratory Equipment
|
| Solicitation No: |
W911S226U3135 |
| Publication URL: |
To access bid details, please log in. |
Liquid Chromatography Mass Spectrometer
Active
Contract Opportunity
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE ARMY
Major Command
AMC
Sub Command
ACC
Sub Command 2
MISSION INSTALLATION CONTRACTING COMMAND
Sub Command 3
419TH CSB
Office
W6QM MICC-FT DRUM
Looking for contract opportunity help?
General Information
-
Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
-
Original Published Date: Apr 30, 2026 12:01 pm EDT
-
Original Date Offers Due: May 15, 2026 12:00 pm EDT
-
Inactive Policy: Manual
-
Original Inactive Date:
Apr 30, 2026
-
Initiative:
Classification
Description
Require an instrument that contains both liquid chromatography and mass spectrometer in paired/joined configuration. The preferred system for the liquid chromatograph and the mass spectrometer should have all items manufactured and serviced by the same company. The integrated software package should be able to operate and control both the mass spectrometer and liquid chromatograph instruments from a single unified operating platform. The system should be capable of performing both qualitative and quantitative analysis on a sample in a single run. Instrument must include all software to process quantification data and acquire samples, automatically restarts upon power failure and detect asymmetry in peak shape for quality assurance/quality control. The instrument must use a dual ion source that can provide both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to the same sample. Desolvation capillary must be removeable and replaced without breaking vacuum which allows for easier maintenance. The detector must use an off axis, high energy conversion dynode coupled with a discrete multistage active film electron multiplier, without phosphorconversion. Maximum nitrogen consumption needs to be 15 L/min or less for nebulization and drying purposes. Autotuning function must be included that optimizes both positive and negative ion modes, all scan speeds, mass axis calibration, sensitivity, and mass resolution automatically with a single tuning solution. Must include a system check to provide essential information on the status of the instrument and can be integrated into batches for smooth maintenance and troubleshooting. Scan speed needs to be 15,000 u/sec in 0.1u steps without reducing scan mass range. Scan step resolution should be 0.7u at all scan speeds. Mass range must be from 2-2000 m/z to enable analysis of a wide range of analytes including large peptides with multi-charge states. Must include delivery and installation to West Point NY, 10996 and include a 1-year warranty on parts and labor.According to DFARS 204.7304 Solicitation provision and contract clauses (c) This is a COTS item and 252.204-7012 would be exempted from this solicitation - this item does not need to be CMMC 2.0 compliant.
Attachments/Links
Contact Information
Contracting Office Address
-
MICC FORT DRUM 4205 PO VALLEY RD
-
FORT DRUM , NY 13602-5220
-
USA
Secondary Point of Contact
History
-
Apr 30, 2026 12:01 pm EDTCombined Synopsis/Solicitation (Original)
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.