52073.12.301, ETC. - CURB RAMPS, PEDESTRIAN SIGNALS, & PAVEMENT MARKINGS AT VARIOUS INTERSECTIONS IN CATAWBA & GASTON COS. Addendum 1

Location: North Carolina
Posted: Aug 5, 2026
Due: Aug 11, 2026
Agency: Division of Highways
Type of Government: State & Local
Category:
  • Y - Construction of Structures and Facilities
  • Z - Maintenance, Repair or Alteration of Real Property
Publication URL: To access bid details, please log in.
  • DL00387
    POC
    52073.12.301, ETC. - CURB RAMPS, PEDESTRIAN SIGNALS, & PAVEMENT MARKINGS AT VARIOUS INTERSECTIONS IN CATAWBA & GASTON COS.
  • Attachment Preview

    JOSH STEIN
    GOVERNOR
    STATE OF NORTH CAROLINA
    DEPARTMENT OF TRANSPORTATION
    August 5, 2026
    DANIEL H. JOHNSON
    SECRETARY
    Contract No.: DL00387
    WBS No.: 52073.12.301, Etc.
    FA Number: TA12301
    County:
    Gaston & Catawba
    Description: Pedestrian Improvements at Various Locations
    August 11, 2026 Letting
    RE: Addendum #1 to Contract No. DL00387
    To Whom It May Concern:
    Reference is made to the proposal furnished to you on this project.
    The following revisions have been made to the proposal and proposal item sheets:
    Sheet No.
    TS-37
    (52073.12.301)
    Revision
    Special Provision has been amended to include a pay item for
    Central Control Unitfor APS Detector
    TS-26 & 27 Special Provision has been amended to include a pay item for
    (52073.12.305) Central Control Unitfor APS Detector
    S-3
    Pay Item No. 44 for Central Control Unitfor APS Detector has
    been added.
    Please download the revised proposal named
    081126_DL00387_CAT_GAST_PROPADDl from the Division 12 Bid Page and discard
    any previous versions. You will also be required to acknowledge the addendum when
    bidding. The electronic bid file and addendum file are available from our current
    electronic bidding provider (Bidx) through their website.
    Mailing Address:
    NC DEPARTMENT OF TRANSPORTATION
    DIVISION 12
    POBOX47
    SHELBY, NC 28151-0047
    Telephone: (980) 552-4200
    Fax: (704) 480-5401
    Courier: 06-53-03
    Website: www.ncdot.gov
    Location:
    1710 E. MARION STREET
    SHELBY, NC 28152
    Docusign Envelope ID: D3A707B6-49CC-8646-80FB-254D8D937A20
    52073.12.301
    BN-0031LA
    TS-1
    Gaston County
    Signals and Intelligent Transportation Systems
    Project Special Provisions
    (Version 24.3)
    Prepared By: X. Han
    5-Aug-26
    8/5/2026
    Document not considered final
    unless all signatures completed.
    Contents
    1. 2024 STANDARD SPECIFICATIONS FOR ROADS & STRUCTURES...............................................................................2
    1.1. ELECTRICAL JUNCTION BOXES (1091-5).....................................................................................................2
    1.2. TRAFFIC SIGNAL ACTIVATION (1700-4) ......................................................................................................2
    1.3. PEDESTALS (1098-15) .......................................................................................................................................2
    2. SIGNAL HEADS.......................................................................................................................................................6
    2.1. MATERIALS .......................................................................................................................................................6
    A. General: ..............................................................................................................................................................6
    B. Vehicle Signal Heads:.........................................................................................................................................8
    C. Pedestrian Signal Heads: ..................................................................................................................................11
    3. CONTROLLERS WITH CABINETS ..................................................................................................................13
    3.1. MATERIALS – TYPE 2070LX CONTROLLERS ............................................................................................13
    3.2. MATERIALS – GENERAL CABINETS...........................................................................................................13
    3.3. MATERIALS – TYPE 170E CABINETS ..........................................................................................................14
    A. Type 170 E Cabinets General: ..........................................................................................................................14
    B. Type 170 E Cabinet Electrical Requirements:..................................................................................................15
    C. Type 170 E Cabinet Physical Requirements:....................................................................................................21
    D. Model 2018 Enhanced Conflict Monitor: .........................................................................................................24
    E. Preemption and Sign Control Box ....................................................................................................................34
    3.4. MATERIALS – TYPE 170 DETECTOR SENSOR UNITS ...............................................................................37
    4. PUSH BUTTON INTEGRATED ACCESSIBLE PEDESTRIAN SIGNAL (APS) ..........................................37
    4.1. DESCRIPTION ..................................................................................................................................................37
    4.2. MATERIALS .....................................................................................................................................................37
    4.3. CONSTRUCTION METHODS .........................................................................................................................39
    4.4. MEASUREMENT AND PAYMENT ................................................................................................................39
    Version 24.3
    1
    print date: 08/05/26
    Docusign Envelope ID: D3A707B6-49CC-8646-80FB-254D8D937A20
    BN-0031LA
    TS-2
    Gaston County
    1. 2024 STANDARD SPECIFICATIONS FOR ROADS & STRUCTURES
    The 2024 Standard Specifications are revised as follows:
    1.1. ELECTRICAL JUNCTION BOXES (1091-5)
    Page 10-209, revise paragraphs beginning on line 26 to read "Provide electrical junction boxes
    with covers of the type and size indicated by the contract or plans for the termination of conduits.
    Boxes and covers shall meet all requirements and specifications of ANSI/SCTE 77. Structural load
    tests shall meet the Tier 15 application type.
    Page 10-209, line 28, revise title of section 1091-5(B) from “Polymer Concrete (PC) Junction
    Boxes” to “Polymer Concrete (PC), Composite, and Thermoplastic Junction Boxes”.
    Page 10-209, revise paragraphs beginning on line 29 through line 41 to read “For PC junction
    boxes, use polymer concrete material made of an aggregate consisting of sand and gravel bound
    together with a polymer and reinforced with glass strands to fabricate box and cover components.
    Provide junction boxes which have bolted covers and open bottoms. Provide vertical extensions
    of 6 inches to 12 inches as required by project provisions.
    Provide the required logo on the cover. Provide at least two size 3/8 inch diameter hex head
    stainless steel cover bolts to match inserts in the box. Provide pull slot(s) with stainless steel pin(s).
    Bodies of junction boxes shall be a single piece.
    Polymer concrete, composite, and thermoplastic junction boxes are not required to be listed
    electrical devices.”
    1.2. TRAFFIC SIGNAL ACTIVATION (1700-4)
    Page 17-4, revise paragraph beginning on line 42 through line 46 to read “Prior to placing signal in
    the steady (stop-and-go) mode, the signal should be placed in yellow-red flashing mode for up to 7
    days or as directed by the Engineer. Yellow-red flashing mode differs from the red-red flashing
    mode shown in the signal plan. Yellow-red flash mode includes flashing the yellow signal
    indications on all main street through movements while flashing the red signal indications on all side
    street signal heads and any left turn heads on the main street. The signal should not be placed in the
    steady (stop-and-go) mode on a Saturday or Sunday without prior approval from the Engineer. Do
    not place the signal in steady (stop-and-go) mode until inspected and without prior approval of the
    Engineer.”
    1.3. PEDESTALS (1098-15)
    Pages 10-226 through 10-230, revise section 1098-15 beginning on page 10-226 line 17 through
    page 10-230 line 10 to read “Furnish pedestal assemblies and their components that are pre-approved
    on the ITS & Signals QPL with foundations that conform to the AASHTO Standard Specifications for
    Structural Supports for Highway Signs, Luminaires, and Traffic Signals, and the Interim Specifications
    as shown on the plans. Refer to Roadway Standard Drawings No. 1743 for structural design
    specifications for each type of pedestal.
    (A) Pedestal Shaft
    Furnish one piece pedestal shafts fabricated from either aluminum or galvanized steel pipe with a
    uniform pipe outer diameter of 4.5 inches and of the lengths specified for the type of pedestal
    shown on Roadway Standard Drawing No. 1743. Refer to Article 1743-2 for pedestal type
    descriptions.
    Version 24.3
    2
    print date: 08/05/26
    Docusign Envelope ID: D3A707B6-49CC-8646-80FB-254D8D937A20
    BN-0031LA
    TS-3
    Gaston County
    For Type I (pedestrian pushbutton pedestals) and Type II (normal-duty pedestals), furnish shafts
    constructed from schedule 40 extruded aluminum pipe that conforms to Aluminum Association
    Alloy 6061-T6 with a tensile strength of 30 ksi and a minimum wall thickness of 0.237 inch.
    Aluminum conduit will not develop the necessary strength required and is not allowed. Thread
    and deburr in accordance with American National Standard Pipe Threads, NPT (ANSI B2.1).
    Finish the exterior with a rough surface texture consisting of a uniform grain pattern that is
    perpendicular to the axis of the pipe along the full pipe length. Unless otherwise specified, do not
    use galvanized steel pipe for Type I and Type II pedestal shafts.
    For Type III (heavy-duty pedestals), furnish schedule 120 galvanized steel pipe that conforms to
    ASTM A53. Provide an 11 inch square by 1 inch thick steel base plate with minimum yield
    strength of 36 ksi that conforms to ASTM A36. Fabricate the base plate with four equally
    spaced bolt holes on an 11 inch bolt circle. Orient the bolt holes in the corners of the plate. Size
    the holes to accommodate 1 inch diameter machine bolts. Weld the pedestal shaft to the center
    of the base plate using a socket connection. Provide circumferential fillet welds at the top and
    bottom of the base plate. Perform all welding in accordance with AWS Code on the plans. Hot-
    dip galvanize the pedestal shaft and base plate assembly after fabrication in accordance with
    ASTM A123. Unless otherwise specified, do not use aluminum pipe for Type III pedestal shafts.
    (B) Transformer Bases
    Furnish transformer bases for each type of pedestal shown on Roadway Standard Drawings No.
    1743 fabricated from aluminum that meets Aluminum Association Alloy 356 or equivalent, and
    that are designed to break upon impact in accordance with AASHTO requirements. Pre-approved
    transformer base shape, size, and bolt circle dimensions may vary by product supplier, but are
    structurally qualified for use by each pedestal type. Compliance with manufacturer’s installation
    instructions is crucial to ensure optimal performance when impacted.
    Provide a 0.5 inch minimum diameter, coarse thread hole cast into transformer base located
    inside of base and oriented for easy access for use in grounding and bonding.
    Provide an access opening for all transformer bases with an access door that is attached with a
    1/4 inch x 3/4 inch long stainless steel vandal proof screw to secure access door.
    For Type I (pedestrian pushbutton pedestals) and Type II (normal-duty pedestals), provide a
    threaded opening at the top of the base to receive a 4 inch NPT pipe shaft. Include a set screw
    prep and 3/8 inch-16 x 1 inch stainless steel set screw to secure the pedestal post to the pedestal
    base. Fabricate the bottom of the transformer base with four equally spaced holes or slots to
    secure the entire assembly to the concrete foundation.
    For Type III (heavy-duty pedestals), provide square bases designed for bolt-on mounting of a
    Type III pedestal shaft. Fabricate the top of the transformer base with four equally spaced holes
    or slots for an 11 inch bolt circle to attach the pedestal shaft. Size the holes or slots to
    accommodate 1 inch diameter machine bolts. Fabricate the bottom of the transformer base with
    four equally spaced holes or slots for a 12 inch bolt circle to secure the entire assembly to the
    concrete foundation. Size the holes or slots to accommodate 1 inch diameter anchor bolts.
    Provide the following mounting hardware for heavy-duty pedestals:
    Version 24.3
    3
    print date: 08/05/26
    This is the opportunity summary page. It provides an overview of this opportunity and a preview of the attached documentation.
    Daily notification on new contract opportunities

    With GovernmentContracts, you can:

    • Find more opportunities and win more business
    • Receive daily alerts for all new bid opportunities
    • Get contract opportunities matched to your business
    ONE WEEK FREE TRIAL

    See also

    ...Project: Pavement Legend Markers Ref. #: 269- 2026-214 Department: City Procurement Type: ITB... ...

    City of Charlotte

    Bid Due: 10/06/2026

    ...Project: Pavement Legend Markers Ref. #: 269- 2026-214 Department: City Procurement Type: ITB... ...

    City of Charlotte

    Bid Due: 10/06/2026

    ...Bid Number: 27-1098 Bid Title: ST-345 Pavement Preservation 2027 Category: Construction Bids... Manual ...

    City of Durham

    Bid Due: 10/08/2026

    ...Bid Number: 27-1097 Bid Title: ST-344C Pavement Management CEI Services 2027 Category: Requests...-344C ...

    City of Durham

    Bid Due: 10/08/2026

    * Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.