REPAIR OF WATER LEAK OF BURROWS POND
| Location: |
Federal |
| Posted: |
Feb 4, 2025 |
| Due: |
Feb 21, 2025 |
| Agency: |
INTERIOR, DEPARTMENT OF THE |
| Type of Government: |
Federal |
| Category: |
- Z - Maintenance, Repair or Alteration of Real Property
|
| Solicitation No: |
140G0125Q0029 |
| Publication URL: |
To access bid details, please log in. |
REPAIR OF WATER LEAK OF BURROWS POND
Active
Contract Opportunity
Department/Ind. Agency
INTERIOR, DEPARTMENT OF THE
Sub-tier
US GEOLOGICAL SURVEY
Office
OFC OF ACQUSITION GRANTS-NATIONAL
Looking for contract opportunity help?
General Information
-
Contract Opportunity Type: Solicitation (Original)
-
Original Published Date: Feb 04, 2025 03:48 pm PST
-
Original Date Offers Due: Feb 21, 2025 10:00 am PST
-
Inactive Policy: 15 days after date offers due
-
Original Inactive Date:
Mar 08, 2025
-
Initiative:
Classification
-
Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
-
Product Service Code: Z2PC - REPAIR OR ALTERATION OF UNIMPROVED REAL PROPERTY (LAND)
-
NAICS Code:
-
238910 - Site Preparation Contractors
-
Place of Performance:
Description
The USGS Conte Anadromous Fish Lab Facility located in Turners Falls, MA has a requirement for the repairs of a leaking underground water line for Burrows Pond. The Conte Lab has a series of 3-8' deep concrete burrows ponds for fisheries holding and experimentation, referred to as the "upper burrows ponds". They are supplied by gravity fed water piping originating at the nearby power canal. Each pond has two 6" PVC supply lines, located at opposite corners. The main supply line is a 12" PVC pipe, there are 5-12"x6" tees with 6" butterfly valves and, at the end of the supply pipe, one 12"x6" reducer, then a "6 90 and a 6" butterfly valve. It has been determined that a significant water leak is present at this last fitting and valve connection. The specific dredging includes, but not limited to the following:
- Saw cut asphalt, remove from site for recycling.
- Excavate around valve and fitting to a depth of approximately 9-10' below grade.
- Perform leak test, determine location and extent of repair.
- Complete all repairs, test for leaks.
- Work will take place in the following county in Massachusetts: Franklin
- Period of Performance is 86 days after notice to proceed is issued.
- The magnitude of construction is between is unknown since part of the contract is Time and Materials.
- Request for Quotes (RFQ) 140G0125Q0029 will close February 21, 2025, at 10:00 am pacific standard time.
- A site visit will be held on February 12, 2025, at 9:00 a.m. (EST) CONTRACTORS ARE STRONGLY ENCOURAGED TO ATTEND THE SITE VISIT. For site visit information please refer to FAR Clauses 52.236-27 and 52.236-27A*1. If you are planning to attend, please email either Dayna Parkin or Rolando (Marty) Garcia at dparkin@usgs.gov or rgarcia@usgs.gov to provide you're the names who are going, and emails along with phone numbers no later than 24 hours before the site visit starts.
- The NAICS Code is 238910. The size standard is $19.0 million. This acquisition will be 100% Small Business Set Aside.
- All question pertaining to this solicitation, including questions that arise during the site visit, must be submitted to dparkin@usgs.gov at least 5 calendar days before the proposals due date. Questions that are not submitted in writing or that are not submitted at least 5 calendar days before the proposal due date may not receive a response.
- The anticipated award date of the contract is March 03, 2025. A vendor must be registered at https://www.sam.gov/portal to be eligible for award. All responsible sources may submit a proposal which shall be considered by the agency. Quotes may be emailed to dparkin@usgs.gov. Faxed Quotes will not be accepted.
Attachments/Links
Contact Information
Contracting Office Address
-
12201 SUNRISE VALLEY DRIVE
-
RESTON , VA 20192
-
USA
Secondary Point of Contact
History
-
Feb 04, 2025 03:48 pm PSTSolicitation (Original)
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
See also
...Follow Z--C&O CANAL NATIONAL HISTORICAL PARK - FY26 REPAIR INLET LOCK 2 Active ...
INTERIOR, DEPARTMENT OF THE
Bid Due: 6/30/2026
...Facilities. Angostura Reservoir, Hot Springs, South Dakota: Provide standby Rescue Team during canal... ...
INTERIOR, DEPARTMENT OF THE
Bid Due: 6/16/2026
.... Attachments/Links Contact Information Contracting Office Address KO CONTRACTING DIVISION 100 CANAL...
DEPT OF DEFENSE
Bid Due: 6/18/2026
...) Product Service Code: Z2KB - REPAIR OR ALTERATION OF CANALS NAICS Code: ...
INTERIOR, DEPARTMENT OF THE
Bid Due: 6/22/2026
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.