Vance AFB, XTLF 14-1010 Repair HVAC F826

Location: Oklahoma
Posted: Jun 11, 2026
Due: Jul 10, 2026
Agency: DEPT OF DEFENSE
Type of Government: Federal
Category:
  • Z - Maintenance, Repair or Alteration of Real Property
Solicitation No: FA302926R0003
Publication URL: To access bid details, please log in.
Follow
Vance AFB, XTLF 14-1010 Repair HVAC F826
Active
Contract Opportunity
Notice ID
FA302926R0003
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE AIR FORCE
Major Command
AIR EDUCATION AND TRAINING COMMAND
Office
FA3029 71 FTW CVC
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information View Changes
  • Contract Opportunity Type: Solicitation (Updated)
  • Updated Published Date: Jun 10, 2026 03:31 pm CDT
  • Original Published Date: May 20, 2026 02:06 pm CDT
  • Updated Date Offers Due: Jul 10, 2026 10:00 am CDT
  • Original Date Offers Due: Jul 10, 2026 10:00 am CDT
  • Inactive Policy: Manual
  • Updated Inactive Date: Jun 10, 2027
  • Original Inactive Date: May 20, 2027
  • Initiative:
    • None
Classification View Changes
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: Z2JZ - REPAIR OR ALTERATION OF MISCELLANEOUS BUILDINGS
  • NAICS Code:
    • 236220 - Commercial and Institutional Building Construction
  • Place of Performance:
    Vance AFB, Enid, OK 73705 73703
Description
This project includes the replacement of HVAC components which have reached end of life, including the main condenser, air handler, and boiler units, and their associated controls. The project will centralize three separate HVAC systems in the building into one central, hydronic system. Fan coil units serving two areas of the building will be replaced to operate from a four-pipe system supplied by the new chiller. Some electrical upgrades are required to support the new system, and LED lighting will be installed to assist with the facility heat load. All work shall be completed in full accordance with the project specifications and drawings.
Attachments/Links
Contact Information
Contracting Office Address
  • ADMIN ONLY NO REQTN CP 580 213 6770 246 BROWN PKWY STE 228 BLDG 500
  • ENID , OK 73705-5037
  • USA
Primary Point of Contact
Secondary Point of Contact


History

Related Document

May 20, 2026[Solicitation (Updated)] Vance AFB, XTLF 14-1010 Repair HVAC F826
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.