FCC HAZELTON, FY25 Water Heating System- PRODUCT ONLY

Location: West Virginia
Posted: Jan 14, 2025
Due: Feb 3, 2025
Agency: JUSTICE, DEPARTMENT OF
Type of Government: Federal
Category:
  • 45 - Plumbing, Heating, and Sanitation Equipment
Solicitation No: 15B12125Q00000008
Publication URL: To access bid details, please log in.
Follow
FCC HAZELTON, FY25 Water Heating System- PRODUCT ONLY
Active
Contract Opportunity
Notice ID
15B12125Q00000008
Related Notice
Department/Ind. Agency
JUSTICE, DEPARTMENT OF
Sub-tier
FEDERAL PRISON SYSTEM / BUREAU OF PRISONS
Office
USP HAZELTON
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
  • Original Published Date: Jan 14, 2025 12:34 pm EST
  • Original Date Offers Due: Feb 03, 2025 02:00 pm EST
  • Inactive Policy: 15 days after date offers due
  • Original Inactive Date: Feb 18, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: 4520 - SPACE AND WATER HEATING EQUIPMENT
  • NAICS Code:
    • 238220 - Plumbing, Heating, and Air-Conditioning Contractors
  • Place of Performance:
    Bruceton Mills , WV 26525
    USA
Description

FCC Hazelton requires a quantity of 4 each indirect plate and frame water heater plus 4 each pumps to accompany the water heaters. Vendors are required to have active SAM.Gov registration and to provide their UEI. A signed SF1449 must be submitted to be considered received. This requirement is for product ONLY. All quotes and bids are required to be submitted to Andrea Burke, Contract Specialist with FCC Hazelton at Ax2burke@bop.gov AND HAX-ProcurementProp-S@bop.gov. Quotes must be valid for at least 30 days after close of bids on February 3, 2025 at 2 PM EDT. Specific product requirements below and example spec sheets attached.



Indirect Plate And Frame Water Heater: (4)



Dimensions cannot Exceed: 63” Height Max; 22” Width max; 61” Base Length – MUST FIT THROUGH STANDARD 36” door. Product should not exceed 1200 lbs – Lite Weight Preferred



FEATURES:



ASME DOUBLE WALL HEAT EXCHANGER



• 316L Stainless Steel



• 150 psi Working Pressure



DIGITAL DISPLAY



• DHW Set Point Range 90°F to 180°F



ADVANCED TEMPERATURE CONTROL



MODULATING CONTROL VALVE



SCALE REDUCING PUMP



AUTOMATIC AIR VENT



ASME TEMPERATURE & PRESSURE RELIEF VALVE



• 210°F and 150 psi



ADJUSTABLE HIGH LIMIT



WYE STRAINERS - DOMESTIC PIPING AND



BOILER PIPING



ISOLATION VALVES - DOMESTIC PIPING AND BOILER PIPING



MODBUS COMMUNICATION



WARRANTY



• 5-Year limited warranty/1-Year limited parts



• Warranty for product only without services requirement



SUGGESTED SPECIFICATION



The Indirect Plate and Frame shall be constructed of a 316 stainless steel plate with EPDM gaskets. Maximum unit dimensions shall be: Length ___61_inches, Width ___22___inches and Height __63______ inches.



The Indirect Plate and Frame shall be a double wall. The plate and frame shall be constructed in accordance with the ASME Boiler and Pressure Vessel Code requirements, stamped and registered with the National Board of Boiler and Pressure Vessel Inspectors



The Indirect Plate and Frame shall have a 150 psi working pressure and be supplied with an ASME temperature and pressure relief valve. Standard equipment shall include Wye Strainers, Isolation Valves, Automatic Air Vent, Scale Reduction Pump, Adjustable High Limit and drain valve



The temperature control shall provide + or – 4 degrees Fahrenheit accuracy with up to a 50% change in load. Setpoint range between 90 and 180 F. Modbus communication shall be standard equipment. The modulating valve shall have a 1000 to 1 turndown. The Indirect Plate and Frame shall be suitable for use with polypropylene glycol, up to 50% concentration. The de-rate associated with the glycol will vary per glycol manufacturer.



Pump: (4) Specifications must meet all below requirements for pump withsystem control and monitoring key



Conditions of Service



Flow: 130 US GPM



Head: 32 ft



Efficiency: 68.6 %



Liquid: Water



Temperature: 60 °C



NPSH required: ft



Pump Data



Specific Gravity: 0.985



Maximum operating pressure: 12 bar



Liquid temperature range: -10 .. 110 °C



Maximum ambient temperature: 40 °C



Flange standard: GF



Pipe connection: GF65



Product number: On request



Motor Data



P1 max: 29 .. 1385 W



Mains frequency: 60 Hz



Enclosure class: X4D



Insulation class: F



Four (4) - Set flanges (2 per set) for line item 0001 tanks

B&G CAST IRON FLANGE PACK, 2" or equivalent





ADDITIONAL INFORMATION: Domestic inlet temp Set point. DHW set point 90 to 180 degrees. GPH for all units together or for each if separated. GPH is for each unit. Each system will supply at minimum hot water to 64-cells, 10-showers, 2-mop closet and 1-staff restroom. Boiler water entering temp 160-180 degrees. Boiler water Leaving temp 120-140 degrees BTU I am looking for specifics on this. -These units are in use 24/7-365 if that helps.



For singled cell showers, 10 to be used at a time with a maximum of up to 128.


Attachments/Links
Contact Information
Contracting Office Address
  • 1460 SKY VIEW DRIVE PO BOX 450
  • BRUCETON MILLS , WV 26525
  • USA
Primary Point of Contact
Secondary Point of Contact
History
  • Jan 14, 2025 12:34 pm ESTCombined Synopsis/Solicitation (Original)

Related Document

Feb 10, 2025[Award Notice (Original)] FCC HAZELTON, FY25 SFF HOT WATER TANKS (PRODUCT ONLY)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

Description: D5 Open End Contract for Rough Cut Lumber Department: DIVISION OF HIGHWAYS

State of West Virginia

Bid Due: 6/16/2026

Description: Barn Run Rebar, 0980 Department: DIVISION OF HIGHWAYS Buyer: Angela L Chaney

State of West Virginia

Bid Due: 6/09/2026

Follow J041--RTAA Chiller Replacement and Removal-Martinsburg VA Medical Center Active Contract Opportunity Notice

VETERANS AFFAIRS, DEPARTMENT OF

Bid Due: 6/10/2026

Description: Construction: Building 22 Stairwell Refinishing Project Department: GENERAL SERVICES DIVISION Buyer: David

State of West Virginia

Bid Due: 6/16/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.