J065-- DC Quantum Electrodynamics and in-vivo dosimetry device

Location: District of Columbia
Posted: Jun 24, 2026
Due: Jul 10, 2026
Agency: VETERANS AFFAIRS, DEPARTMENT OF
Type of Government: Federal
Category:
  • J - Maintenance, Repair, and Rebuilding of Equipment
Solicitation No: 36C24526Q0618
Publication URL: To access bid details, please log in.
Follow
J065-- DC Quantum Electrodynamics and in-vivo dosimetry device
Active
Contract Opportunity
Notice ID
36C24526Q0618
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
245-NETWORK CONTRACT OFFICE 5 (36C245)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • Original Published Date: Jun 24, 2026 12:29 pm EDT
  • Original Response Date: Jul 10, 2026 12:00 pm EDT
  • Inactive Policy: Manual
  • Original Inactive Date: Jul 20, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: J065 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES
  • NAICS Code:
    • 334517 - Irradiation Apparatus Manufacturing
  • Place of Performance:
    Department of Veterans Affairs Washington DC VAMC Washington , DC 20422
    USA
Description
THIS REQUEST FOR INFORMATION IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION.
This is a Request for Information (RFI)/Sources Sought Notice (SS), this is not a Request for Quotes (RFQ) or Request for Proposals (RFP). No formal solicitation document exists at this present time. This is not a solicitation announcement. The purpose of this Sources Sought notice NAICS 334517 - Irradiation Apparatus Manufacturing PSC J065 Medical Equipment and Accessories and Supplies
NAIC size standard of employees for the Washington DC VAMC.

Responses to this Sources Sought notice will be utilized by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought notice, a solicitation announcement may or may not be published in SEWP, FedBizOpps (FBO) or GSA ebuy.

REQUESTED INFORMATION

If you are interested and capable, and can provide the required service, please provide the requested information for questions 1-15 as indicated below:

Responses to this Sources Sought notice shall also include: company name, address, point of contact, if applicable contract number, product brochures, place of manufacturer, NAIC/PSC codes, Sam Uei number, table date completed, price, suppliers, distributors, domestic and non domestic equipment that is similar and business size:
Is this service/product priced on vendor s GSA/SEWP/FSS/NAC/SAC contract? Yes/No
If yes, provide vendor contract number?
Is this service/product open market pricing? Yes/No
Is open market priced online? Yes/No
Provide vendor s business size status and representations NAIC and PSC code?
Does vendor have capability, product, and interest for Brand name XXXXX end item product requirement? Yes/No
Does vendor have capability, product, and interest of an equal end item product? Yes/ No
If equal product end item; provide equal product name/model/ product brochure/ specification sheet/warranty/life expectancy/maintenance requirements information.
Where is brand name end item product place of manufacturer?
Where is equal end item product place of manufacturer?
Is interested vendor LG/SB/SDVOSB/VOSB (which BS) manufacturer or (which BS) authorized distributor of an equal domestic end item product?
Is interested vendor LG/SB/SDVOSB/VOSB (which BS) manufacturer or (which BS) authorized distributor of brand name a domestic end item product?
Is interested vendor LG/SB/SDVOSB/VOSB (which BS) manufacturer or (which BS) authorized distributor of nondomestic brand name end item product?
Is interested vendor LG/SB/SDVOSB/VOSB (which BS) manufacturer or (which BS) authorized distributor of nondomestic equal end item product?
Provide a copy authorized distributor letter if vendor is not the manufacturer.

SOW
GENERAL INFORMATION

ITEM NUMBER
DESCRIPTION
PRICE
PART NUMBER
MANUFACTURER NAME/MODEL NUMBER/MODEL NAME
PLACE OF MANUFACTRER
0001
Wired option RF in-vivo dosimetry four channels and expandable to 52 channels, with standard control module with PC software VA TRM Software compliant includes Microsoft SQL patient database, automatic correction factors, Record and Verify interface, patient data encryption, login monitoring, event tracking, and audit control.


0002
measure particles and radiation in Quantum Electrodynamics device medical QED semiconductor diodes used in electron radiation therapy. (3m Cable/Negative)


0003
a clinical diode detector for in-vivo dosimetry in radiation therapy. Detects real time dose tracking photon energy beams ranging from 6 to 12 MV with a (3m Cable Negative)


0004
a flat silicon diode detector for in vivo dosimetry and radiation therapy quality assurance high-energy photon treatments measures 15-25MV exact radiation dose delivered to patients with a (3m Cable/Negative).


0005
specialized cylinder-shaped semiconductor diode Detector Calibrated specifically for intermediate megavoltage photon beams spanning 6 MV to 12 MV with a (3m Cable/Negative)


0006
single-isocenter multiple-met SRS treatments, more stringent off-axis QA efficiently measures targets up to 7 cm off-axis within 0.1 mm accuracy to - reduced phantom placement errors sphere-shaped targets (5 mm in diameter) set at precise locations Calculable accuracy up to 7 cm off isocenter


NOTES

All Capability Statements/Responses to this Sources Sought notice shall be submitted via email stephanie.henderson3@va.gov Telephone, Fax, or any other form of communication inquiries will not be reviewed or accepted in response to this Sources Sought notice. Responses to this Sources Sought notice must be received no later than 7/10/26 at 1:00 p.m. (Eastern Standard Time). This Sources Sought notice is to assist the VA in determines sources only. A solicitation is not currently available. If a solicitation is issued, it may or may not be announced at a later date, and all interested parties shall respond to that solicitation announcement separately from the responses to this Sources Sought notice.

DISCLAIMER

This Request for Information (RFI) is issued for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked a proprietary will be handled accordingly in accordance with (IAW) Federal Acquisition Regulation (FAR) 15.201(e), RFIs may be used when the Government does not presently intend to award a contract, but wants to obtain price, delivery, other market information, or capabilities for planning purposes. Responses to these notices are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses incurred associated with responding to this RFI.

End of Notice
Attachments/Links
Contact Information
Contracting Office Address
  • 8849 International Drive Suite 215
  • LINTHICUM , MD 21090
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Jun 24, 2026 12:29 pm EDTSources Sought (Original)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.