MUNICIPALITY OF ANCHORAGE DIVISION 02 - EXISTING CONDITIONS
MAC CENTER DOOR REPLACEMENT
Section 02 41 00 - Page 1
Burkhart Croft Architects, LLC
DEMOLITION
SECTION 02 41 00 - DEMOLITION
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Selective demolition of building elements for alteration purposes.
1.02 RELATED REQUIREMENTS
A. Drawings and general provisions of the Contract, including Municipality of Anchorage
Standard Specifications - Buildings (MASSB), General and Supplementary Conditions apply to
this Section.
1.03 DEFINITIONS
A. Demolish: Dismantle, raze, destroy, or wreck any building or structure or any part thereof.
B. Remove: Detach or dismantle items from existing construction and dispose of them off site,
unless items are indicated to be salvaged or reinstalled.
C. Remove and Reinstall: Detach or dismantle items from existing construction in a manner to
prevent damage. Clean and prepare for reuse and reinstall where indicated.
D. Existing to Remain: Designation for existing items that are not to be removed and that are not
otherwise indicated to be salvaged or reinstalled.
1.04 MATERIAL OWNERSHIP
A. Unless otherwise indicated, demolition waste becomes property of Contractor.
1.05 REFERENCE STANDARDS
1.06 SUBMITTALS
A. Pre-demolition Photographs or Video: Submit before Work begins.
B. Project Record Documents: Accurately record actual locations of capped and active utilities and
subsurface construction.
C. Warranties: Documentation indicated that existing warranties are still in effect after completion
of selective demolition.
1.07 WARRANTY
A. Notify warrantor on completion of selective demolition, and obtain documentation verifying
that existing system has been inspected and warranty remains in effect. Submit documentation
at Project closeout
BCA Project Number 2213.33

MUNICIPALITY OF ANCHORAGE DIVISION 02 - EXISTING CONDITIONS
MAC CENTER DOOR REPLACEMENT
Section 02 41 00 - Page 2
Burkhart Croft Architects, LLC
DEMOLITION
PART 2 PRODUCTS -- NOT USED
PART 3 EXECUTION
3.01 DEMOLITION
A. Remove portions of existing buildings as indicated on drawings
B. Remove other items indicated, for salvage and reinstallation.
3.02 GENERAL PROCEDURES AND PROJECT CONDITIONS
A. Comply with applicable codes and regulations for demolition operations and safety of adjacent
structures and the public.
1. Obtain required permits.
2. Take precautions to prevent catastrophic or uncontrolled collapse of structures to be
removed; do not allow worker or public access within range of potential collapse of
unstable structures.
3. Provide, erect, and maintain temporary barriers and security devices.
4. Use physical barriers to prevent access to areas that could be hazardous to workers or the
public.
5. Conduct operations to minimize effects on and interference with adjacent structures and
occupants.
6. Do not close or obstruct roadways or sidewalks without permits from authority having
jurisdiction.
7. Conduct operations to minimize obstruction of public and private entrances and exits. Do
not obstruct required exits at any time. Protect persons using entrances and exits from
removal operations.
8. Obtain written permission from owners of adjacent properties when demolition equipment
will traverse, infringe upon, or limit access to their property.
B. Do not begin removal until receipt of notification to proceed from Owner.
C. Protect existing structures and other elements to remain in place and not removed.
1. Provide bracing and shoring.
2. Prevent movement or settlement of adjacent structures.
3. Stop work immediately if adjacent structures appear to be in danger.
D. Minimize production of dust due to demolition operations. Do not use water if that will result in
ice, flooding, sedimentation of public waterways or storm sewers, or other pollution.
3.03 SELECTIVE DEMOLITION FOR ALTERATIONS
A. Existing construction and utilities indicated on drawings are based on casual field observation
and existing record documents only.
1. Verify construction and utility arrangements are as indicated.
BCA Project Number 2213.33

MUNICIPALITY OF ANCHORAGE DIVISION 02 - EXISTING CONDITIONS
MAC CENTER DOOR REPLACEMENT
Section 02 41 00 - Page 3
Burkhart Croft Architects, LLC
DEMOLITION
2. Report discrepancies to Architect before disturbing existing installation.
3. Beginning of demolition work constitutes acceptance of existing conditions that would be
apparent upon examination prior to starting demolition.
B. Separate areas in which demolition is being conducted from areas that remain occupied.
C. Maintain weatherproof exterior building enclosure, except for interruptions required for
replacement or modifications; prevent water and humidity damage.
D. Remove existing work as indicated and required to accomplish new work.
1. Remove rotted wood, corroded metals, and deteriorated masonry and concrete; replace
with new construction indicated.
2. Remove items indicated on drawings.
E. Protect existing work to remain.
1. Prevent movement of structure. Provide shoring and bracing as required.
2. Perform cutting to accomplish removal work neatly and as specified for cutting new work.
3. Repair adjacent construction and finishes damaged during removal work.
4. Patch to match new work.
3.04 DEBRIS AND WASTE REMOVAL
A. Remove debris, junk, and trash from site.
B. Leave site in clean condition, ready for subsequent work.
C. Clean up spillage and wind-blown debris from public and private lands.
END OF SECTION
BCA Project Number 2213.33

DIVISION 06 - WOOD, PLASTICS, AND
MUNICIPALITY OF ANCHORAGE
COMPOSITES
MAC CENTER DOOR REPLACEMENT
Section 06 10 53 - Page 1
Burkhart Croft Architects, LLC
MISCELLANEOUS ROUGH CARPENTRY
SECTION 06 10 53 - MISCELLANEOUS ROUGH CARPENTRY
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Preservative treatment (PPT).
B. Concealed wood blocking, nailers, and supports.
1.02 RELATED REQUIREMENTS
A. Drawings and general provisions of the Contract, including Municipality of Anchorage
Standard Specifications - Buildings (MASSB), General and Supplementary Conditions apply to
this Section.
1.03 REFERENCE STANDARDS
A. AWPA M4 - Standard for the Handling, Storage, Field Fabrication and Field Treatment of
Preservative-Treated Wood Products; 2026.
B. AWPA U1 - Use Category System: User Specification for Treated Wood; 2025.
C. ICC (IBC) - International Building Code; Most Recent Edition Adopted by Authority Having
Jurisdiction, Including All Applicable Amendments and Supplements.
D. PS 20 - American Softwood Lumber Standard; 2025.
E. SPIB (GR) - Standard Grading Rules; 2021.
F. WCLIB (GR) - WCLB Standard Grading Rules for West Coast & Imported Softwood Lumber
No.18; 2024.
G. WWPA G-5 - Western Lumber Grading Rules; 2025.
1.04 SUBMITTALS
A. Product Data:
1. Pressure-preservative treatment.
2. Field-applied preservative treatment product data and application instructions.
1.05 DELIVERY, STORAGE, AND HANDLING
A. Cover wood products to protect against moisture. Support stacked products to prevent
deformation and allow air circulation.
PART 2 PRODUCTS
2.01 GENERAL REQUIREMENTS
A. Dimension Lumber: Comply with PS 20 and requirements of specified grading agencies.
BCA Project Number 2213.33

DIVISION 06 - WOOD, PLASTICS, AND
MUNICIPALITY OF ANCHORAGE
COMPOSITES
MAC CENTER DOOR REPLACEMENT
Section 06 10 53 - Page 2
Burkhart Croft Architects, LLC
MISCELLANEOUS ROUGH CARPENTRY
1. Grading Agency: Grading agency whose rules are approved by the Board of Review,
American Lumber Standard Committee (www.alsc.org), and that provides grading service
for species and grade specified. Provide lumber stamped with grade mark unless otherwise
indicated.
2. Lumber of other species or grades is acceptable provided structural and appearance
characteristics are equivalent to or better than products specified.
2.02 DIMENSION LUMBER
A. Grading Agency: Southern Pine Inspection Bureau, Inc; SPIB (GR).
B. Grading Agency: Pacific Lumber Inspection Bureau, and grading standard WCLIB (GR).
C. Grading Agency: Western Wood Products Association; WWPA G-5.
D. Sizes: Nominal sizes as indicated on drawings, S4S.
E. Moisture Content: Kiln-dry or MC15.
F. Miscellaneous Framing, Blocking, Nailers, Grounds, and Furring:
1. Lumber: S4S, No.2 or Standard Grade.
2.03 PRESSURE-PRESERVATIVE TREATMENT (PPT)
A. Provide factory-treated wood members in accordance with AWPA U1 and use category
indicated.
B. Preservative Limitations for Interior Use Categories UC1 and UC2:
C. Applications - Treat the Following:
1. Wood sills, sleepers, blocking, furring, stripping, and similar concealed members in
contact with masonry or concrete
D. Kiln-dry wood after treatment with waterborne preservative to maximum moisture content of
19 percent for lumber and 15 percent for plywood.
E. Perform fabrication such as cutting, boring, milling, and surfacing to maximum extent
practicable before treatment.
F. Label preservative-treated wood with marking as required by AWPA U1 and ICC (IBC).
Unless otherwise permitted by standard U1 and the building code, include the following
markings: AWPA U1, accredited inspection agency's mark, treating plant identification, type
of preservative, retention, and end use.
G. Field Treatment for Cuts and Holes in Preservative-Treated Wood: Comply with AWPA M4.
2.04 ACCESSORIES
A. Metal and Finish of Fasteners:
1. Preservative-Treated Wood:
a. Nails, timber rivets, wood screws, and lag screws - general use: Type 304 stainless
steel.
b. Staples: Type 304 stainless steel.
BCA Project Number 2213.33

DIVISION 06 - WOOD, PLASTICS, AND
MUNICIPALITY OF ANCHORAGE
COMPOSITES
MAC CENTER DOOR REPLACEMENT
Section 06 10 53 - Page 3
Burkhart Croft Architects, LLC
MISCELLANEOUS ROUGH CARPENTRY
2. Untreated Wood: Type 316 stainless steel.
PART 3 EXECUTION
3.01 INSTALLATION - GENERAL
A. Select material sizes to minimize waste.
B. Reuse scrap to greatest extent possible; clearly separate scrap for use on-site as accessory
components, including shims, bracing, and blocking.
C. Where treated wood is used on interior, provide temporary ventilation during and immediately
after installation sufficient to remove indoor air contaminants.
3.02 BLOCKING, NAILERS, AND SUPPORTS
A. Provide framing and blocking members as indicated or as required to support finishes, fixtures,
specialty items, and trim.
B. In metal stud walls, provide continuous blocking around door and window openings for
anchorage of frames, securely attached to stud framing.
C. In walls, provide blocking attached to studs as backing and support for wall-mounted items
unless item can be securely fastened to two or more studs or another method of support is
explicitly indicated.
D. Where ceiling mounting is indicated, provide blocking and supplementary supports above
ceiling unless another method of support is explicitly indicated.
3.03 SITE-APPLIED WOOD TREATMENT
A. Apply preservative treatment to field-cut surfaces in accordance with manufacturer's
instructions wherever cuts, holes, sawing, or other fabrication of wood members is required
after pressure-preservative treatment.
B. Apply preservative treatment in accordance with manufacturer's instructions.
C. Allow preservative to dry prior to erecting members.
END OF SECTION
BCA Project Number 2213.33

DIVISION 07 - THERMAL AND MOISTURE
MUNICIPALITY OF ANCHORAGE
PROTECTION
MAC CENTER DOOR REPLACEMENT
Section 07 92 00 - Page 1
Burkhart Croft Architects, LLC
JOINT SEALANTS
SECTION 07 92 00 - JOINT SEALANTS
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Nonsag gunnable joint sealants.
B. Joint backings and accessories.
1.02 RELATED REQUIREMENTS
A. Drawings and general provisions of the Contract, including Municipality of Anchorage
Standard Specifications - Buildings (MASSB), General and Supplementary Conditions apply to
this Section.
B. Section 08 12 13 - Hollow Metal Frames
1.03 REFERENCE STANDARDS
A. ASTM C794 - Standard Test Method for Adhesion-in-Peel of Elastomeric Joint Sealants; 2018
(Reapproved 2022).
B. ASTM C920 - Standard Specification for Elastomeric Joint Sealants; 2018 (Reapproved 2024).
C. ASTM C1087 - Standard Test Method for Determining Compatibility of Liquid-Applied
Sealants with Accessories Used in Structural Glazing Systems; 2023.
D. ASTM C1193 - Standard Guide for Use of Joint Sealants; 2025.
E. ASTM C1248 - Standard Test Method for Staining of Porous Substrate by Joint Sealants; 2022.
F. ASTM C1330 - Standard Specification for Cylindrical Sealant Backing for Use with Cold
Liquid-Applied Sealants; 2023.
G. SCAQMD 1168 - Adhesive and Sealant Applications; 1989, with Amendment (2022).
1.04 SUBMITTALS
A. Product Data: Submit manufacturer's technical datasheets for each product to be used; include
the following:
1. Physical characteristics, including movement capability, VOC content, hardness, cure
time, and color availability.
2. List of backing materials approved for use with the specific product.
3. Backing material recommended by sealant manufacturer.
4. Substrates that product is known to satisfactorily adhere to and with which it is
compatible.
5. Substrates the product should not be used on.
B. Color Cards for Selection: Where sealant color is not specified, submit manufacturer's color
cards showing standard colors available for selection.
BCA Project Number 2213.33

DIVISION 07 - THERMAL AND MOISTURE
MUNICIPALITY OF ANCHORAGE
PROTECTION
MAC CENTER DOOR REPLACEMENT
Section 07 92 00 - Page 2
Burkhart Croft Architects, LLC
JOINT SEALANTS
C. Samples for Verification: Where custom sealant color is specified, obtain directions from
Architect and submit at least two physical samples for verification of color of each required
sealant.
D. Preconstruction Laboratory Test Reports: Submit at least four weeks prior to start of
installation.
E. Installer's qualification statement.
F. Executed warranty.
1.05 QUALITY ASSURANCE
A. Preconstruction Laboratory Testing: Arrange for sealant manufacturer(s) to test each
combination of sealant, substrate, backing, and accessories.
1. Adhesion Testing: In accordance with ASTM C794.
2. Compatibility Testing: In accordance with ASTM C1087.
3. Allow sufficient time for testing to avoid delaying the work.
4. Deliver sufficient samples to manufacturer for testing.
5. Report manufacturer's recommended corrective measures, if any, including primers or
techniques not indicated in product data submittals.
1.06 WARRANTY
A. Manufacturer Warranty: Provide 2-year manufacturer warranty for installed sealants and
accessories that fail to achieve a watertight seal, exhibit loss of adhesion or cohesion, or do not
cure. Complete forms in Owner's name and register with manufacturer.
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. Nonsag Sealants:
1. Dow: www.dow.com/#sle.
2. Hilti, Inc: www.hilti.com/#sle.
3. Sika Corporation: usa.sika.com/#sle.
4. Substitutions: See Section 01 60 00 - Product Requirements.
2.02 JOINT SEALANT APPLICATIONS
A. Scope:
1. Exterior Joints:
a. Seal the following joints:
1) Joints between doors, windows, and other frames or adjacent construction.
2. Interior Joints:
a. Seal the following joints:
BCA Project Number 2213.33

DIVISION 07 - THERMAL AND MOISTURE
MUNICIPALITY OF ANCHORAGE
PROTECTION
MAC CENTER DOOR REPLACEMENT
Section 07 92 00 - Page 3
Burkhart Croft Architects, LLC
JOINT SEALANTS
1) Joints between door frames and adjacent construction.
3. Do Not Seal:
a. Joints where sealant is specified to be furnished and installed by manufacturer of
product to be sealed.
b. Joints where sealant installation is specified in other sections.
B. Exterior Joints: Use nonsag nonstaining silicone sealant, unless otherwise indicated.
C. Interior Joints: Use nonsag polyurethane sealant, unless otherwise indicated.
2.03 JOINT SEALANTS - GENERAL
A. Sealants and Primers: Provide products having lower volatile organic compound (VOC)
content than indicated in SCAQMD 1168.
2.04 NONSAG JOINT SEALANTS
A. Nonstaining Silicone Sealant: ASTM C920, Grade NS, Uses M, A, G, and O; not expected to
withstand continuous water immersion or traffic.
1. Movement Capability: Plus 100 percent and minus 50 percent, minimum.
2. Nonstaining to Porous Stone: Nonstaining to light-colored natural stone when tested in
accordance with ASTM C1248.
3. Dirt Pick-Up: Reduced dirt pick-up compared to other silicone sealants.
4. Color: To be selected by Architect from manufacturer's standard range.
5. Cure Type: Single-component, neutral moisture curing.
6. Products:
a. Dow; DOWSIL 790 Silicone Building Sealant: www.dow.com/#sle.
B. Polymer Sealant: ASTM C920; single component, cured sealant is paintable and mold/mildew
resistant, low odor and VOC, and ultraviolet (UV) resistant.
1. Color: Clear.
C. Polyurethane Sealant: ASTM C920, Grade NS, Uses M and A; single or multi-component; not
expected to withstand continuous water immersion or traffic.
1. Movement Capability: Plus 100 percent, minus 50 percent, minimum.
2. Color: To be selected by Architect from manufacturer's standard range.
3. Products:
a. Sherwin-Williams Company: Loxon NS2 Two Component Non-Sag Polyurethane
Sealant: www.sherwin-williams.com/#sle.
2.05 ACCESSORIES
A. Sealant Backing Rod, Closed-Cell Type:
1. Cylindrical flexible sealant backings complying with ASTM C1330 Type C.
2. Size: 25 to 50 percent larger in diameter than joint width.
BCA Project Number 2213.33

This is the opportunity summary page. It provides an overview of this opportunity and a preview of the attached documentation.
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

Bid Name General Documents That Pertain To Bids ID 001 Status Open Categories

City of Ketchikan

Bid Due: 1/06/2030

Follow Solicitation for a Concessions Business Opportunity to provide Kayak Rental Services within

INTERIOR, DEPARTMENT OF THE

Bid Due: 12/28/2026

Request for Proposal: Recovery and Transitional Housing Planning Consultant The Kenaitze Indian Tribe

Kenaitze Indian Tribe

Bid Due: 11/16/2026

Follow Deposition Court Reporting Services; U.S. Attorney's Office, District of Alaska Active Contract

JUSTICE, DEPARTMENT OF

Bid Due: 11/17/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.