FLUKE T5-1000

Location: Virginia
Posted: Aug 7, 2025
Due: Aug 13, 2025
Agency: DEPT OF DEFENSE
Type of Government: Federal
Category:
  • 66 - Instruments and Laboratory Equipment
Solicitation No: SPMYM125Q0137
Publication URL: To access bid details, please log in.
Follow
FLUKE T5-1000
Active
Contract Opportunity
Notice ID
SPMYM125Q0137
Related Notice
SPMYM125Q0137
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEFENSE LOGISTICS AGENCY
Major Command
DLA MARITIME
Sub Command
DLA MARITIME SHIPYARDS
Office
DLA MARITIME - NORFOLK
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Solicitation (Original)
  • Original Published Date: Aug 07, 2025 01:55 pm EDT
  • Original Date Offers Due: Aug 13, 2025 12:00 pm EDT
  • Inactive Policy: 15 days after date offers due
  • Original Inactive Date: Aug 28, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: 6625 - ELECTRICAL AND ELECTRONIC PROPERTIES MEASURING AND TESTING INSTRUMENTS
  • NAICS Code:
    • 334515 - Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
  • Place of Performance:
    Portsmouth , VA 23709
    USA
Description

The Defense Logistics Agency (DLA) Maritime Norfolk at Norfolk Naval Shipyard (NNSY)



intends to award a Firm Fixed Price (FFP) Single Award Contract as Lowest Price Technically



Acceptable (LPTA) Evaluation Factors for the item listed below. The required item is for



commercial item prepared in accordance with the information in FAR Part 13 and FAR Subpart



12.6, as supplemented with the additional information included in this notice.





The Contract Line Item (CLIN) is as follows:





ITEM NO.



DESCRIPTION



QTY



U/I



UNIT PRICE



TOTAL



0001



FLUKE T5-1000



ELECTRICAL TESTER KIT WITH HOLSTER AND 1AC II VOLTAGE TESTER



MODEL#: FLUKE T5-H5-1AC II KIT



REF P/N 2PY98





100



EA



Determined by vendors



Determined by vendors





T5-600/T5-1000



Electrical Tester













Parts and Service



The tester is warranted to be free from defects in material and workmanship for two years, while under normal use. Parts and repairs are warranted for 90 days. For the complete warranty statement, refer to the



TS-600/TS-1000 Electrical Tester Instruction Sheet.



To order parts, or for warranty service, contact Fluke as follows: USA: 1-888-99-FLUKE (1-888-993-5853)



Canada: 1-800-36-FLUKE (l-800-363-5853) Europe: +31402-675-200



Japan: +81-3-3434-0181



Singapore: +65-738-5655



Anywhere in the world: +1-425-446-5500 Or, visit Fluke's Web site at www.fluke.com.





Specifications



Accuracy is specified for one year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy specifications are given as follows:



::!;([ % of reading] + [number of least significant digits])



Temperature coefficient of 0.1 x (specified accuracy)/ °C for 28 °C (82.4 °F)





Serial Numbers 79560000 and Above



General Specifications





Calibration



One-year calibration cycle.



Maximum Voltage



Between any Terminal and Earth Ground



TS-600: 600 V rms, Overvoltage Category Ill, Pollution Degree 2



TS-1000: 1000 V rms, Overvoltage Category Ill, 600 V RMS, OverVoltage Category IV, Pollution Degree 2



Maximum Voltage



Between Current Fork and Earth Ground



TS-600 and T5-1000: 1000 V rms, Overvoltage Catergory Ill, also 600 V rms, Overvoltage Category IV, Pollution Degree 2, (This dual rating applies to the current fork only.)



Temperature



Operating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F)



Altitude



Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)



Relative Humidity



O o/o to 95 %, 5 °C to 30 °C (41 °F to 86°F); o o/o to 75 %, 30 °C to 40 °C (86 °F to 104 °F);



O o/o to 45 %, 40 °C to 50 °C (104 °F to 122 °F)



Battery Type and Life



AA (2); 360 hours continuous with alkaline; 125 hours continuous with zinc chloride



Shock, Vibration



1 m drop at -10 °C to + 50 °C (14 °F to 122 °F) per ANSI/ISA-S82.0l-1994 and EN 61010-1



1995. Random vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)



Surge Protection



TS-600: 6 kV per IEC 61010, T5-1000: 8 kV per IEC 61010



Enclosure Rating



IP 52 per IEC 60529, no vacuum applied





General Specifications (continued)





RF Field Specification



0.5 % full scale + (specified accuracy) at 3 V/m



Safety



Complies with ANSI/ISA-S82.0l-94, UL Classified to IEC 61010, CSA/CAN C22.2 No.1010.1- 92, and EN61010-11995.



EMC



EN 61326



Certifications



CE

In accordance with IEC 61010-1 54CJ



Resolution and Accuracy





Function



TS-600 Range



TS-1000 Range



Resolution



Accuracy



v



600 V rms



1000 V rms



lV



:!(1.5 % + 2 digits)



v



600V



1000V



lV



:!(1% + 1 digit)



~A



100.0A



100.0A



0.lA



:!(3 % + 3 digits)



n



10000



1000 0



10



:!(1o/o + 2 digits)



Input Characteristics









Function



Input Protection



Input impedance (nomial



T5-600



TS-1000



v



600 V rms



1000 V rms



1 MO,

v



600 V rms



1000 V rms



1 MO,

n



600 V rms



1000 V rms







n



Open Circuit Test Voltage



Short Circuit Current



1.65 V de (nominal)





CAT Ill protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings.



CAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service.



Serial Numbers 79559999 and Below



General Specifications



Calibration



One-year calibration cycle.



Maximum Voltage Between any Terminal



and Earth Ground



TS-600: 600 V rms, Overvoltage Category Ill TS-1000: 1000 V rms, Overvoltage Category Ill



Temperature



Operating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F)



Altitude



Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)



Relative Humidity



0 o/o to 95 %, 5 °C to 30 °C (41 °F to 86°F); 0 o/o to 75 %, 30 °C to 40 °c (86 °F to 104 °F);



0 o/o to 45 %, 40 °c to 50 °C (104 °F to 122 °F)



Battery Type and Life



AA (2); 400 hours continuous with alkaline; 200 hours continuous with zinc chloride





T5-600/T5-1000



Electrical Tester













General Specifications (continued)





Shock, Vibration



1 m drop at 15 °C to 35 °c (59 °F to 95 °F) per ANSI/ISA-S82.0l-1994 and EN 61010-11993.



Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)



Surge Protection



T5-600: 6 kV per IEC 1010-1, 1990-09: T5-1000: 8 kV per IEC 1010-1, 1990-09



Enclosure Rating



IP 52 per IEC 60529, no vacuum applied



RF Field Specification



0.5 % full scale + (specified accuracy) at 3 V/m



Safety



Complies with ANSI/ISA-S82.0l-94 for use in overvoltage category Ill (CAT Ill) locations, UL3111, CSA/CAN C22.2 No.1010.1-92, and EN61010-l 1993.



EMC



EN 50081-1, EN 50082-1



Certifications



( E c@us ct ®®



Resolution and Accuracy





Function



TS-600 Range



TS-1000 Range



Resolution



Accuracy



v



600 V rms



1000 V rms



lV



:!(1.5 % + 2 digits)



v



600V



1000V



lV



:!(1% + 1 digit)



A



100.0A



100.0A



0.lA



:!(3 % + 3 digits)



n



10000



10000



10



:!(1% + 2 digits)



Input Characteristics







Function



Input Protection



Input impedance (nomial



T5-600



T5-1000



v



600 V rms



1000 V rms



1 MO,

v



600 V rms



1000 V rms



1 MO,

n



600 V rms



1000 V rms







n



Open Circuit Test Voltage



Short Circuit Current



2.4 V de (nominal)





CAT 111 protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings.



CAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service.



Cleaning the Tester



�Warning



To avoid electric shock or damage to the tester, never allow water inside the case. To avoid damaging the tester's case, never use solvents on the tester.



If the tester requires cleaning, wipe it down with a cloth that is lightly dampened with water or a mild detergent. Do not use aromatic hydrocarbons, chlorinated solvents, or methanol-based fluids when wiping down the tester.











The requirement will be solicited as a total small business set aside. The NAICS code applicable to this procurement is 334515, Electrical and Electronic Properties Measuring and Testing Instruments, with a size standard of 750 employees. The Product Service Code is 6625. The solicitation document incorporates provisions and clauses in effect through FAC 2025-04 and DFARS Change Notice 01/17/2025.





The anticipated delivery date for this acquisition is 6 weeks after receipt of contract. The solicitation, any documents related to this procurement, and all amendments issued will be in electronic form only.





The solicitation number is SPMYM125Q0137, and it is expected to be available on or about



07 AUG 2025 and posted to SAM.gov, https://sam.gov/ Quotes will be due by 12:00 PM EST on 13 AUG 2025. Responses to the solicitation notice shall be emailed to the attention of Curtis Douglas at Curtis.douglas@dla.mil . Please make sure that the solicitation number



(SPMYM125Q0137) is included in the subject line of any email correspondence. Emails



without subject lines will not be read because of security issues.





Potential offerors are hereby notified that the solicitation and any subsequent amendments will only be available by downloading the documents at www.SAM.gov (Contracting Opportunities). The Government is not responsible for the inability of the Offeror's to access solicitation documents posted. Prospective Offeror's should also register on the interested vendor list under SPMYM125Q0137. No telephone or FAX requests will be accepted, and no hardcopy solicitation/amendment will be mailed or faxed.





All responsible sources may submit a proposal which may be considered by the Government. By submitting a quote, the offeror will be self-certifying that neither the principal corporate officials nor owners are currently suspended, debarred, or otherwise ineligible to receive contracts from any federal agency. Failure to do so may represent grounds for refusing to accept the proposal. By submission of a proposal, the offeror acknowledges the requirement that a prospective awardee must be registered in the System for Award Management (SAM) database prior to award, during performance, and through final payment of any contract resulting from the



solicitation, except for awards to foreign vendors for work to be performed outside the United



States. Lack of registration in the SAM database will make an offeror ineligible for award.



Offerors may obtain information on registration and annual confirmation requirements by calling



1-866-606-8220, or via the Internet at https://www.sam.gov. All questions shall be submitted in



accordance with the solicitation, dates and procedures. Please direct all questions regarding this



requirement to Curtis Douglas at Curtis.douglas@dla.mil






Attachments/Links
Contact Information
Contracting Office Address
  • CONTRACTING DIVISION (DLA-NMAB)
  • PORTSMOUTH , VA 23709-5000
  • USA
Primary Point of Contact
Secondary Point of Contact


History

Related Document

Aug 7, 2025[Presolicitation (Original)] FLUKE T5-1000
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

Follow NATO Business Opportunity: Custodial Services Active Contract Opportunity Notice ID RFP-ACT-SACT-26-62 Related

COMMERCE, DEPARTMENT OF

Bid Due: 6/25/2026

Improve Center Woods Complex Status: Open DBB 120068 Virginia Polytechnic Institute and State

State Government of Virginia

Bid Due: 6/10/2026

RFP 26-176-4342-1 URBAN FORESTRY MASTER PLAN Status: Open RFP 120041 City of Chesapeake

State Government of Virginia

Bid Due: 6/17/2026

RFP-26-27-3349NS - Dental Insurance Status: Open RFP 119890 Hanover County -Hanover County, Virginia

State Government of Virginia

Bid Due: 6/11/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.