Temporary Dehumidification System w/ Inline Heaters_Rev1
| Location: |
Connecticut |
| Posted: |
Dec 16, 2025 |
| Due: |
Dec 22, 2025 |
| Agency: |
DEPT OF DEFENSE |
| Type of Government: |
Federal |
| Category: |
- 41 - Refrigeration, Air Conditioning and Air Circulating Equip.
|
| Solicitation No: |
N3904026Q3088 |
| Publication URL: |
To access bid details, please log in. |
Temporary Dehumidification System w/ Inline Heaters_Rev1
Active
Contract Opportunity
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE NAVY
Major Command
NAVSEA
Sub Command
NAVSEA SHIPYARD
Office
PORTSMOUTH NAVAL SHIPYARD GF
Looking for contract opportunity help?
General Information View Changes
-
Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
-
Updated Published Date: Dec 16, 2025 09:14 am EST
-
Original Published Date: Dec 09, 2025 12:24 pm EST
-
Updated Date Offers Due: Dec 22, 2025 05:00 pm EST
-
Original Date Offers Due: Dec 17, 2026 05:00 pm EST
-
Inactive Policy: 15 days after date offers due
-
Updated Inactive Date: Jan 06, 2026
-
Original Inactive Date:
Jan 01, 2027
-
Initiative:
Classification
-
Original Set Aside: No Set aside used
-
-
Product Service Code: 4120 - AIR CONDITIONING EQUIPMENT
-
NAICS Code:
-
532490 - Other Commercial and Industrial Machinery and Equipment Rental and Leasing
-
Place of Performance:
Groton
,
CT
06340
USA
Description View Changes
See attachments for solicitation details.
REVISION 1: Adding the below Q&A, updating the Period of Performance, and extending the solicitation deadline to 12/22/25 @ 5:00 PMEST
-
Will the desiccant be powered by a generator or an existing 200A utility service? Existing facility power
-
Will the desiccant run 24/7 or specific hours of the day? Yes
-
Can you please specify what will be powering the inline heaters and the footage of cord required to power them? Existing house power or generator? 10ft or greater whip with bare copper wire ends
-
It looks like the heaters are going to be inline with the process ducting so we assume they will probably either 25', 50' or 75’ away from the DCCU. Assuming that the 200’ of ducting is split between the process and react from the DCCU. Yes
-
Will the base provide their own duct clamps? No
-
What is the application of the desiccant? Will the inline heaters be required if the desiccant output air is approx 140F? To strip moisture from the air. Inline heaters are required.
-
On the day of delivery, will an allotted 8 hrs be sufficient for personnel entry, training, badging, inspections, set up, start up, commissioning, and training? yes
-
Will the unit be in a secured area? Are electronic and wireless devices allowed in this area? Are gps locators on equipment acceptable? Yes secured area, use of wireless or electronic devices is per posted signage.
-
Would you like the weekly inspection rates broke out if the unit does not require weekly inspections and maintenance? Please see the SOW for weekly inspection and maintenance requirements and include it in your pricing.
Attachments/Links
Contact Information
Contracting Office Address
-
PORTSMOUTH NH 03801-5000
-
PORTSMOUTH , NH 03801-5000
-
USA
Secondary Point of Contact
History
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.