SMALL BUSINESS MULTIPLE AWARD CONSTRUCTION PROJECT- B2189 REPLACE ROOF AND HVAC SYSTEM

Location: Maryland
Posted: May 30, 2025
Due: Jun 17, 2025
Agency: DEPT OF DEFENSE
Type of Government: Federal
Category:
  • Z - Maintenance, Repair or Alteration of Real Property
Solicitation No: N4008023R0022009
Publication URL: To access bid details, please log in.
Follow
SMALL BUSINESS MULTIPLE AWARD CONSTRUCTION PROJECT- B2189 REPLACE ROOF AND HVAC SYSTEM
Active
Contract Opportunity
Notice ID
N4008023R0022009
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE NAVY
Major Command
NAVFAC
Sub Command
NAVFAC ATLANTIC CMD
Sub Command 2
NAVFAC WASHINGTON
Office
NAVFACSYSCOM WASHINGTON
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Solicitation (Original)
  • Original Published Date: May 30, 2025 05:37 pm EDT
  • Original Date Offers Due: Jun 17, 2025 02:00 am EDT
  • Inactive Policy: 15 days after date offers due
  • Original Inactive Date: Jul 02, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: Z2AA - REPAIR OR ALTERATION OF OFFICE BUILDINGS
  • NAICS Code:
    • 236220 - Commercial and Institutional Building Construction
  • Place of Performance:
    Patuxent River , MD 20670
    USA
Description

THIS SOLICITATION IS OPEN ***EXCLUSIVELY*** TO THE FOLLOWING SMALL BUSINESS MULTIPLE AWARD CONSTRUCTION CONTRACTORS:





C.E.R., Inc.



877 Baltimore Annapolis Blvd., Suite 101



Severna Park, Maryland 21146





CJW Contractors, Inc.



13849 Park Center Rd, Suite B



Herndon, Virginia, 20171





Edifice Services JV, LLC



507 N. Frederick Ave, Suite 104



Gaithersburg, Maryland 20877





ENCON Desbuild JV3 LLC



8201 Corporate Drive, Suite 720



Hyattsville, Maryland 20785





EVCON-CWC JV, LLC



3176 ½ Bladensburg Rd NE, Suite 1



Washington, District of Columbia 20018





Fastbreak General Contractors, LLC



47 W Queens Way Suite G1



Hampton, Virginia 23669





Ocean Construction Services



104 Aragona Blvd Suite 101



Virginia Beach, Virginia 23462





Ritz Construction



47 East All Saints Street, Suite 6



Frederick, Maryland 21701







This construction project involves the replacement of roofing and HVAC systems. The following summary outlines the key components of the scope of work.



Roof Replacement:



The Roof Project includes the Removal and Installation of a new approximately 33,800 SF modified bitumen roof excluding the roofs of the Security Station and associated covered walkway to the northwest.



The Roof Work shall include but is not limited to the removal of existing: modified bitumen roofing system, ridged insulation, expansion joints, pipe sleeves, flashing and counter flashings, reglets, water damaged wood decking, metal fascia, gutters, downspouts, roof drain covers, gutters, gutter downspouts and any other related items associated with roofing work. Existing roof ladders are to be removed and reinstalled in place. The access door at the north side of highest most roof it to be removed and a new appropriately sized door is to be installed, due to the increase in roof insulation the flashings and counter flashing may conflict with the height of the door. All operations equipment is to be removed and stored per Supported Command instruction prior to work beginning. The Contractor is to remove and replace approximately 30% of joists and roof deck that are damaged due to water intrusion. The Contractor is to remove and replace in kind 500 LF of wood fascia and vent soffit in locations of water damage.



Testing of the roof drains shall be tested after roof installation, any failed roof drains are the responsibility of the contractor. Contingent on the results of the test work shall be done to ensure proper drainage. Lead testing is required prior to the beginning of work.



Provide a new roof system complies with ICC code. Provide metal flashing, counter flashing, vent sleeves, stainless steel rain covers over pitch pockets, seal base of pitch pockets with elastomeric sealant, curbs for new HVAC units, metal roof drain strainers, crickets, coping (if required), metal fascia, gutters, downspouts, and expansion joints. Interior work shall include the repair of ceilings; repair any damaged ceiling finishes to match existing (30%). The existing wood deck and joists areas to be replaced where required.



HVAC Replacement:



The HVAC project includes but is not limited to demolition and installation of new HVAC system to include ductwork, piping, wiring, control devices, and all other appurtenances comprising a complete and operable system. Contractor shall verify location and dimensions of existing mechanical and electrical equipment, shall coordinate all work prior to the start of construction.



Contractor shall comply with federal, state, and local codes and laws involving abandonment and sealing of Geothermal HVAC system. The Geothermal Loop must be sealed by a Certified Master Well Driller. All fluid in the boreholes/tubing must be removed, includes sampling of the liquid to ensure it does not contain additives making it Hazardous Waste. If it is a Hazardous Waste, the liquid must properly dispose in methods in accordance with applicable federal, state, and local codes and laws. A Well abandonment form must be submitted to Maryland Department Environmental (MDE) after sealing. Provide copy of the form to contracting officer. See Attached form in part 6.



Contractor shall provide radon testing for 90 days for each habitable room after the project completion. Contractor shall comply with Radon Testing Standard Procedures in accordance with EPA and Navy Radon Assessment and Mitigation Program (NAVRAMP) Guidebook for Naval Shore Installations.



Contractor shall provide Structural Engineer to perform roof structural analyzes, load calculation, and solution to reinforce existing roof to support the new load of HVAC equipment.



Contractor shall carefully remove existing security cameras, audio notification devices, fire alarm and detectors to accommodate the work spaces. Shall be reinstalled at their original locations after the completion of work.



Contractor shall ensure proper handling, storage and proper disposal of all hazardous material, recovery and recycle HVAC system refrigerants, test downspouts and roof drainage are functioning properly after the project completion in accordance with NAS PAX River CATEX environmental requirements. See part 6 attachment.



Provide grass sod replacement damaged during construction.



Please see the solicitation and detailed scope of work attached to this post for additional information.



If you have any questions please don’t hesitate to contact me.





v/r



Jennifer Coffman



Contract Specialist



NAVFAC Washington



Cell Phone: (202) 436-1831



Fax: (301)-342-3141



jennifer.e.coffman2.civ@us.navy.mil



22445 Peary Rd Bldg. 504



Patuxent River, MD 20670






Attachments/Links
Contact Information
Contracting Office Address
  • 1314 HARWOOD STREET SE
  • WASHINGTON NAVY YARD , DC 20374-5018
  • USA
Primary Point of Contact
Secondary Point of Contact
History
  • May 30, 2025 05:37 pm EDTSolicitation (Original)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.