| Location: | North Carolina |
|---|---|
| Posted: | Jul 14, 2026 |
| Due: | Aug 27, 2026 |
| Agency: | State Government of North Carolina |
| Type of Government: | State & Local |
| Category: |
|
| Solicitation No: | 121-071426JVC-S202 |
| Publication URL: | To access bid details, please log in. |
| Solicitation Number: | 121-071426JVC-S202 |
| Project Title: | South Campus Building S202 Ceiling Tile Replacement & Corridors Re-Painting |
| Description: | Partial demolition and replacement of existing ceiling tiles and grids per marked-up plans provided, verification/corrections as needed for existing above ceiling infrastructure and independent structural support for any non-compliant anchoring or support of IT cabling, HVAC ductwork, fire alarm devices, lighting, and any other miscellaneous concealed conditions for corrective work, Installation of new ceiling grid and tiles where marked on plans to re-align with existing HVAC and lighting already in place, which may need additional support. Additional Scope of Work in the attached document |
| Opening Date: | 8/27/2026 2:00 PM |
| Posted Date: | 7/14/2026 |
| Status: | Open |
| Department: | ROWAN-CABARRUS COMMUNITY COLLEGE |
|
Solicitation Number
*
121-071426JVC-S202
|
Department
ROWAN-CABARRUS COMMUNITY COLLEGE
|
Status Reason
Open
|
|
|
Opening Date
2026-08-27T14:00:00.0000000
|
Posted Date
*
2026-07-14T14:59:11.0000000Z
|
Primary Commodity Code
Construction Services
|
|
|
Mandatory Conference/Site Visit
2026-08-12T04:00:00.0000000Z
|
Special Instructions
Site Visit @ 10:00AM, Electronic Submissions Only
|
Solicitation Type
*
Select RFP IFB RFI
|
|
|
Owner
Ronda Holland
|
|||
|
Description
Partial demolition and replacement of existing ceiling tiles and grids per marked-up plans provided, verification/corrections as needed for existing above ceiling infrastructure and independent structural support for any non-compliant anchoring or support of IT cabling, HVAC ductwork, fire alarm devices, lighting, and any other miscellaneous concealed conditions for corrective work, Installation of new ceiling grid and tiles where marked on plans to re-align with existing HVAC and lighting already in place, which may need additional support. Additional Scope of Work in the attached document
|
|||
IFB # 121-071426JVC
South Campus Building S202 Ceiling Tile Replacement & Corridors Re-Painting
ROWAN-CABARRUS COMMUNITY COLLEGE
1531 Trinity Church Rd.
Concord, NC
INVITATION TO BID
NOTICE TO BID
Sealed bids for the Rowan-Cabarrus Community College, South Campus Building S202 Ceiling Tile
Replacement and Corridors Re-Painting Project will be received via email, (pdf format only, maximum 20
MG) at collegeenvironment@rccc.edu until, but no later than 2:00 pm, local prevailing time, Thursday,
August. 27, 2026, and then publicly opened and read immediately thereafter via ZOOM. Bidders are
encouraged to view the bid opening in real time via a ZOOM link that follows.
The Bid Name and IFB # 121-071426JVC shall be referenced as the subject line of all emails.
Bidders shall be Contractors licensed in North Carolina, with Owner approved sub-contractors as required. The
General Contractor shall be the Prime Contractor, and the bid shall contain all work required to ensure complete
and satisfactory installation as designed. Bidders will receive an email receipt notification that their bids have
been received.
Bids received after the announced time and date for submittal will be rejected. Bidders are responsible for
ensuring their bid is received before the deadline indicated. All firms must be registered with the North Carolina
Electronic Vendor Portal (eVP and Purchase Orders) prior to presenting a proposal. Failure to register may result
in disqualification. North Carolina Electronic Vendor Portal may be found at https://evp.nc.gov/
Contractual Requirement: All bidders must agree to execute a contract that incorporates and adheres to the
State of North Carolina's General Terms and Conditions. These terms are available for review
at: https://www.doa.nc.gov/north-carolina-general-terms-and-conditions-5-2025/open.
Bid bonds are required in the amount of 5% of the total bid submitted. If paying by check, send to:
Rowan-Cabarrus Community College
PO Box 1595, (1333 Jake Alexander Blvd. S, for courier, etc.)
Salisbury, NC 28145
ATTN: Ronda Holland
Checks must be received by 2:00 pm, Thursday, August 27, 2026. Only Bid Bond checks can be mailed, bids
and other items must be sent via email.
A Mandatory Pre-Bid Conference will be held at 10:00 am on Wednesday, August 12, 2026, at the South
Campus Building S202, 1531 Trinity Church Rd., Concord, NC. Attendees to gather at the left side Stair
Tower Entry as viewed from the parking Lot. The purpose of this meeting will be to review the areas for rework
as highlighted in the marked-up existing drawings. Attendance at the meeting is required to submit a bid.
Page 1 of 3
IFB # 121-071426JVC
SCOPE OF WORK
1. Partial demolition and replacement of existing ceiling tiles and grids per marked-up plans provided,
2. Verification / corrections as needed for existing above ceiling infrastructure and independent structural
support for any non-compliant anchoring or support of IT cabling, HVAC ductwork, fire alarm devices,
lighting, and any other miscellaneous concealed conditions for corrective work,
3. Installation of new ceiling grid and tiles where marked on plans to re-align with existing HVAC and lighting
already in place, which may need additional support.
a. NOTE: New corridor ceiling tiles and grid on second and third floors to be re-worked to center
sprinkler heads in 2x2 ACT. Verifications with Facilities and College Environment on site for any
issues.
b. Three areas for different installations (ref. attached plans):
i. Ceiling Tile replacements only
ii. Ceiling Tile and Grid replacement
iii. Add Alternate Ceiling Tile and Grid Replacement
4. Compliance with Rowan-Cabarrus Community College Facilities Design Manual (FDM) Specifications,
and North Carolina Building Code requirements.
5. Re-painting all corridor walls for all three levels with College specified and approved color as noted in the
Facilities Design Manual in eggshell finish.
PROJECT OVERVIEW / Additional Details for Compliance
1. Construction Phasing and Access
* Maintain campus access and emergency routes at all times.
* Coordinate construction sequencing with the College to minimize disruption.
* Provide temporary pedestrian control, barricades, and signage as required.
2. Quality Control and Acceptance
* Final acceptance is contingent upon visual inspection, and compliance with specifications.
3. Deliverables
* Construction schedule.
* Material and Subcontractor Submittals of planned use and staffing.
* Warranty information per College standards. See FDM.
4. Assumptions and Exclusions
* Scope is based on the provided mark-ups attached below, and listings above.
* Any major scope changes resulting from concealed conditions shall be addressed through Requests for
Information and any formal Change Order processes, if required.
All inquiries for clarifications and questions must be received via email to john.cole@rccc.edu by Monday,
August 17, 2026 at 1:00 pm and will be answered via Addendum no later than 5:00 PM, August 19, 2026.
ATTACHMENTS
1. Drawings - South S202 High-lighted Former Project Drawings
AD201 - First Level Reflected Ceiling Plan - Demolition - dated April 08, 2024
AD202 - Second Level Reflected Ceiling Plan - Demolition - dated April 08, 2024
AD203 - Third Level Reflected Ceiling Plan - Demolition - dated 04-08-24
2. Facility Design Manual Standards -2024 - Part 3 Ceiling Grid & Tiles - 3.9.2
Page 2 of 3
IFB # 121-071426JVC
BID OPENING ZOOM LINK
Join Zoom Meeting
https://rccc-edu.zoom.us/j/93147817418
Meeting chat link
https://rccc-edu.zoom.us/launch/jc/93147817418
Meeting ID: 931 4781 7418
---
One tap mobile
+16465588656,,93147817418# US (New York)
+16469313860,,93147817418# US
Join instructions
https://rccc-
edu.zoom.us/meetings/93147817418/invitations?signature=yLFGPa26hxbkrFX5umdPoyHVjMZ75TgGQ
3FCosP6giY
END OF INVITATION TO BID
Page 3 of 3
| DRAWINGS | |||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| NG GRID AND YPICAL | REMOVE EXISTING FIRE ALARM DEVICES, SMOKE DETECTORS, OCCUPANCY SENSORS ETC, IN CEILINGS TO BE REMOVED, TYPICAL SEE ELECTRICAL DRAWINGS WELDING .0 LAB 110 REMOVE EXISTING SPRINKLER HEADS AND RE-INSTALL IN NEW CEILING, SEE SHEET A102 REMOVE EXISTING LIGHT FIXTURES SHOWN DOTTED AND RE-USE IN ELSEWHERE IN NEW WORK, SEE SHEET A102 AND ELECTRICAL DRAWINGS REMOVE EXISTING ROLL DOWN PROJECTION SCREEN, PROJECTOR AND SPEAKERS AND RETURN TO OWNER C.0 | ||||||||||||||||||||||||||||
| CLASSROOM 108 | |||||||||||||||||||||||||||||
| OS | OS | OS | S S OS | ||||||||||||||||||||||||||
| F C.0 | |||||||||||||||||||||||||||||
| F | F | S | |||||||||||||||||||||||||||
| F | |||||||||||||||||||||||||||||
| OPEN OS | |||||||||||||||||||||||||||||
| R | OFFICE 104B | OFFICE 105 | CLASSROOM 106 | C | LASSROOM 107 | C.0 CORRIDOR OFFICE 101F 110B C S OFFICE 110A | |||||||||||||||||||||||
| OS | OS | ||||||||||||||||||||||||||||
| F | R | S | |||||||||||||||||||||||||||
| OFFI 104 | CE A C.1 R | F | OR S | ||||||||||||||||||||||||||
| CLASSROOM | C.8 | C.1 OFFICE 103 OS F CORRIDOR 101C | CLASSROOM 113 OS F | R C.3 CORRIDOR 101E S OS R C. | C.3 C.3 C.3 C.3 S | ||||||||||||||||||||||||
| 102 R OS | F | C.7 R OS | C.1 | OFFICE 103 OS F | OS F | F CLASSROOM OS 111 S | |||||||||||||||||||||||
| RRIDOR 101C | 3 S | ||||||||||||||||||||||||||||
| C.2 C.2 R C.2 C.1 C.2 | C.2 | C.1 | R | REMO | C.3 C.3 C.3 C.3 VE PORTION OF EXISTING CEILING REMOV S TO INSTALL NEW GWB HEADER TILE SH S | C.0 E EXISTING CEILING GRID AND | C.2 C.2 R R R C.1 C.2 C.2 | ||||||||||||||||||||||
| S C.1 | CORRIDOR S 101B | C.1 S | GRID | OWN DOTTED C.1 S | |||||||||||||||||||||||||
| STAIR #1 190 | C.2 C.0 C.2 ELEVATOR LOBBY 101A ELEV. C.2 S 191 C.2 | C.2 C.1 STORAGE 112 F C.1 | C.2 R C.1 STAIR #2 192 | ||||||||||||||||||||||||||
| C.1 WOMEN 115 | EXISTING GWB HEA REMAIN | DER TO |
| EFLECTED CEILING PLAN KEYED NOTES |
|---|
| NO WORK REMOVE EXISTING CEILING TILES, EXISTING GRID TO REMAIN REMOVE EXISTING LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS REMOVE EXISTING LIGHT FIXTURE AND RE-USE IN NEW WORK, SEE ELECTRICAL DRAWINGS INFILL NEW CEILING GRID TEES TO MATCH EXISTING FOR 2X2 LAYOUT AND PROVIDE NEW CEILING TILE NEW LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS EXISTING LIGHT FIXTURE RE-USED IN NEW LOCATION, SEE ELECTRICAL DRAWINGS EXISTING CEILING MOUNTED PROJECTOR TO REMAIN, RELOCATE MOUNT SLIGHTLY AS NECESSARY TO INSTALL NEW CEILING GRID TEES EXISTING WALL MOUNTED ROLL DOWN SCREEN TO REMAIN REMOVE EXISTING WALL MOUNTED ROLL DOWN SCREEN AND RE-USE IN NEW WORK. |
| WALL LEGEND |
|---|
| EXISTING WALL TO BE REMOVED EXISTING WALL TO REMAIN EXISTING 1 HR RATED WALL TO REMAIN EXISTING 2 HR RATED WALL TO REMAIN |
| NEW 1 HR RATED WALL NEW WALL E: WALL SYMBOLOGY FOR GRAPHICAL PURPOSES ONLY. ER TO PARTITION TYPES AND WALL SECTIONS FOR ACTUAL L CONSTRUCTION. |
REMOVE EXISTING HVAC DIFFUSERS
IN CEILINGS TO BE REMOVED, TYPICAL
SEE MECHANICAL DRAWINGS
REMOVE EXISTING WINDOW SHADES EXISTING WINDOW SHADES
1 2 3 4 5 6 DURING DEMOLITION AND NEW WORK, 7 TO REMAIN, UNLESS NOTED 8 9 10
AND REINSTALL IN SAME LOCATION AT OTHERWISE
END OF PROJECT
REMOVE EXISTING LIGHT FIXTURES
SHOWN DOTTED AND RE-USE IN NEW
WORK, SEE SHEET A201 AND ELECTRICAL
DRAWINGS
A A
CLASSROOM
REMOVE EXISTING CEILING GRID AND
108
TILE SHOWN DOTTED, TYPICAL
OS S S
OS OS OS REMOVE EXISTING FIRE ALARM
DEVICES, SMOKE DETECTORS,
OCCUPANCY SENSORS ETC, IN
CEILINGS TO BE REMOVED, TYPICAL
SEE ELECTRICAL DRAWINGS
F
C.0
REMOVE EXISTING WINDOW SHADES
DURING DEMOLITION AND NEW WORK,
AND REINSTALL IN SAME LOCATION AT S
END OF PROJECT
F
F
F
OPEN
OS
OFFICE
CLASSROOM
105 CLASSROOM 107
106
R
C.0
OFFICE
104B OS OS
B B
CORRIDOR OFFICE
R 101F 110B
F WELDING
C.0
OFFICE S LAB
104A C.1 110
CORRIDOR
REMOVE EXISTING SPRINKLER HEADS REMOVE EXISTING SPRINKLER HEADS AND IN CEILINGS TO BE REMOVED, TYPICAL 101D SEE FIRE PROTECTION DRAWINGS F S S RE-INSTALL IN NEW CEILING, SEE SHEET A102 R
OFFICE
110A
C C
R
C.3 C.3 C.3 C.3 C.3 REMOVE EXISTING LIGHT FIXTURES OWNERSHIP OF INSTRUMENTS OF SERVICE:
SHOWN DOTTED AND RE-USE IN
ELSEWHERE IN NEW WORK, SEE SHEET All reports, specifications, plans, computer files, field
A102 AND ELECTRICAL DRAWINGS data, notes, and other documents and instruments
NO CEILING WORK IN AREAS
S
SHOWN SHADED, TYPICAL of service shall remain the property of the Design
EXISTING WINDOW SHADES Professional. The Design Professional shall retain
TO REMAIN, UNLESS NOTED CORRIDOR all common law, statutory and other reserved rights,
CLASSROOM
OTHERWISE 102 C.7 C.8 C.1 101E REMOVE EXISTING ROLL DOWN PROJECTION including the copyright thereto.
OFFICE CLASSROOM S SCREEN, PROJECTOR AND SPEAKERS AND This drawing is the property of Yates -Chreitzberg -
R R F RETURN TO OWNER Hughes Architectsand is not to be reproduced or
OS F OS 103 113 OS F OS CLASSROOM OS copied in whole or any part. It is not to be used on
OS F 111 S any other project and is to be returned upon request.
R
CORRIDOR
(C) Copyright 2024
101C
C.0
EXISTING GWB HEADER TO C.3
REMAIN
S
C.1 C.3 C.3 C.3 C.3
R C.0
C.2 C.2 REMOVE PORTION OF EXISTING CEILING REMOVE EXISTING CEILING GRID AND C.2 C.2
S
GRID TO INSTALL NEW GWB HEADER TILE SHOWN DOTTED
R R
CORRIDOR
S C.1 S 101B C.1 S S C.1 S
R R
C.1
C.2
D C.2 C.2 D
R
C.1 C.1
C.2 C.2 C.2 C.2
C.0 STORAGE
STAIR #1 C.1
112
190 C.2 ELEVATOR
LOBBY
101A ELEV. F STAIR #2
C.2 S 191 192
C.1
C.2
C.1 C.1
OTS
JANITOR MECH./ELEC.
MEN
REMOVE EXISTING CEILING 117 180
TILE, 2x2 GRID TO REMAIN 116 EXISTING GWB HEADER TO
S WOMEN REMAIN
115
C.0
BOILER
180A
ELEV.
MACH.
180B OTS
C.0
S
C.0
E E
1 2 3 4 5 6 7 8 9 10
N
N
TRUE PLAN
REFLECTED CEILING PLAN KEYED NOTES
CEILING LEGEND
WALL LEGEND
C.0 NO WORK
S SMOKE DETECTOR
C.1 REMOVE EXISTING CEILING TILES, EXISTING GRID TO REMAIN
2x4 RECESSED LED FIXTURE SUPPLY AIR DIFFUSER EXISTING WALL TO BE REMOVED
OS OCCUPANCY SENSOR C.2 REMOVE EXISTING LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS
EXISTING WALL TO REMAIN
RETURN AIR DIFFUSER /
F FIRE ALARM DEVICE C.3 REMOVE EXISTING LIGHT FIXTURE AND RE-USE IN NEW WORK, SEE ELECTRICAL DRAWINGS EXHAUST GRILLE
2x2 RECESSED LED FIXTURE
CAMERA C.4 INFILL NEW CEILING GRID TEES TO MATCH EXISTING FOR 2X2 LAYOUT AND PROVIDE NEW CEILING TILE EXISTING 1 HR RATED WALL TO REMAIN
REFLECTED CEILING BASE BID / ALTERNATE RECESSED LED DOWN LIGHT S SPEAKER WITH GRILLE C.5 NEW LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS
UPRIGHT SPRINKLER HEAD EXISTING 2 HR RATED WALL TO REMAIN
C.6 EXISTING LIGHT FIXTURE RE-USED IN NEW LOCATION, SEE ELECTRICAL DRAWINGS
CEILING MOUNTED LIGHT SPRINKLER HEAD MOUNTED IN CEILING
LINEAR SUPPLY AIR DIFFUSER NEW 1 HR RATED WALL
WORK SHOWN IN THE FOLLOWING ROOMS IS BASE BID. C.7 EXISTING CEILING MOUNTED PROJECTOR TO REMAIN, RELOCATE MOUNT SLIGHTLY AS
NECESSARY TO INSTALL NEW CEILING GRID TEES
INDICATES CEILING MOUNTED DEVICES, SPRINKLER HEADS, ETC. TO BE REMOVED
EXIT SIGN
NEW WALL
101C 101D 101E 104A 104B 105 106 107 107A 111 112 117A 117B 117C 118A 118B 118C C.8 EXISTING WALL MOUNTED ROLL DOWN SCREEN TO REMAIN
R
DIRECTIONAL EXIT SIGN INDICATES CEILING MOUNTED DEVICES, SPRINKLER HEADS, ETC. TO BE RELOCATED NOTE: WALL SYMBOLOGY FOR GRAPHICAL PURPOSES ONLY.
ALL OTHER WORK SHOWN ON THE REFLECTED CEILING PLAN IS TO BE INCLUDED IN ALTERNATE #2 LOCATED IN CENTER OF NEW CEILING TILE, TYPICAL C.9 REMOVE EXISTING WALL MOUNTED ROLL DOWN SCREEN AND RE-USE IN NEW WORK. REFER TO PARTITION TYPES AND WALL SECTIONS FOR ACTUAL
WALL CONSTRUCTION.
202S
gnildiuB
CCCR
snoitavoneR
72082
CN
,drocnoC
|
dR
hcruhC
ytinirT
1351
7035 NORTHWINDS DR NW
CONCORD, NC 28027
704.788.2000
www.ycharch.com
CONSULTANT:
PROFESSIONAL SEALS:
Z B
ERG-HUGHE
S
R E
I
T
E D
ARCHITECTURAL
CO R
A
R
C H
S - E C T H GI S ER T E R CER 3 T 1 . 0 NO. P O R N O A T I I S T T E C
A ,
Y A P. NORTHCAROLINA .
CONCORD,
N.
C.
CLIENT:
SCO #22-25351-02A
NCCCS #2692
YCHA COM.#:
PHASE & DATE:
REVISIONS:
SHEET TITLE:
ARCHITECTURAL:
MP
11:20:6
4202/31/4
202S
gnidliuB
CCCR
00.91222\seliF
lacoL
tiveR\:S
tvr.moc.hcrahcy@hllib_snoitavoneR
22219.00
CONSTRUCTION DOCUMENTS
1 FIRST LEVEL REFLECTED CEILING PLAN - DEMOLITION
04-08-24
AD201 3/16" = 1'-0"
FIRST LEVEL
REFLECTED CEILING
PLAN - DEMOLITION
AD201
| R R R R F CLASSROOM 212 R OS R R R C.0 C.1 C.0 R STORAGE STORAGE OFFICE 212C 212B 212A | STOR. 214A | STOR. 217A C.0 STOR. 216A C.0 C. E R R R S S | |||||||||||
| R S F R S C.0 C.1 R R R C.1 WOMEN C.1 224 | S OS CLASSROOM CL 213 R R R S | C.0 OS OS C.0 S F STOR. 214B CLASSROOM 216 C.0 C.0 STOR. 215 R R S C.1 CLASSROOM C.1 208 | S | ||||||||||
| S S | |||||||||||||
| F OS | OS | ||||||||||||
| S ASSROOM | S | CLASSROOM 217 | S | ||||||||||
| 214 C.0 | C. | 0 | F S | ||||||||||
| R CORRIDOR 201C CLASSROOM 209 C.1 | E S | LEC. 280 OFF 2 C.0 | ICE OFFICE 19 OS OS 220 C.1 C.1 | ||||||||||
| S R F OS S S C.1 OFFICE 210 R R ENTRANCE 200 S OPEN TO ABOVE R R C.1 F | CORRIDOR 201B C.2 VESTIBULE R 201E C.1 S C.2 C.1 MEN 225 C.1 | R S C.8 OS C.7 STOR. 203 C.1 | R S R F OS | R R OS F S | R CORRIDO OS C.8 201D S C.7 C.1 | R J C | CORRIDOR R 218 F OS C.1 C.1 OFFICE OFFICE 222 221 OS OS ENTRANCE 202 OPEN TO ABOVE | ||||||
| COR R R R R R 2 S | RIDOR R 01A | R R S | R R R S | R | R S | ||||||||
| C.2 S C.2 ELEV. ELEV. R LOBBY 191 C.2 226 C.2 OFFICE | S S R R CLASSROOM 205 OS S | R CLAS F R | S S R R R SROOM CLASSROOM 207 206 F |
| R R | |
| R F | |
| CLASSROOM 212 | |
| R OS |
| REFLECTED CEILING PLAN KEYED NOTES |
|---|
| C.0 NO WORK C.1 REMOVE EXISTING CEILING TILES, EXISTING GRID TO REMAIN C.2 REMOVE EXISTING LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS C.3 REMOVE EXISTING LIGHT FIXTURE AND RE-USE IN NEW WORK, SEE ELECTRICAL DRAWINGS C.4 INFILL NEW CEILING GRID TEES TO MATCH EXISTING FOR 2X2 LAYOUT AND PROVIDE NEW CEILING TILE C.5 NEW LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS C.6 EXISTING LIGHT FIXTURE RE-USED IN NEW LOCATION, SEE ELECTRICAL DRAWINGS C.7 EXISTING CEILING MOUNTED PROJECTOR TO REMAIN, RELOCATE MOUNT SLIGHTLY AS NECESSARY TO INSTALL NEW CEILING GRID TEES C.8 EXISTING WALL MOUNTED ROLL DOWN SCREEN TO REMAIN C.9 REMOVE EXISTING WALL MOUNTED ROLL DOWN SCREEN AND RE-USE IN NEW WORK. |
| WALL LEGEND |
|---|
| EXISTING WALL TO BE REMOVED EXISTING WALL TO REMAIN EXISTING 1 HR RATED WALL TO REMAIN EXISTING 2 HR RATED WALL TO REMAIN |
| NEW 1 HR RATED WALL NEW WALL E: WALL SYMBOLOGY FOR GRAPHICAL PURPOSES ONLY. ER TO PARTITION TYPES AND WALL SECTIONS FOR ACTUAL L CONSTRUCTION. |
1 2 3 4 5 6 7 NO CEILING WORK IN AREAS 8 9 10
SHOWN SHADED, TYPICAL
A A
STOR.
214A
S
R R
C.0 STOR.
217A
C.0
EXISTING WINDOW SHADES
TO REMAIN, TYPICAL S S
S F S F OS
R R R OS OS
EXISTING CUBICLE CURTAIN R S OS S OS C.0 S F S CLAS 2 S 1 R 7 OOM S
AND TRACK TO REMAIN F
STOR. STOR.
CLASSROOM CLASSROOM 214B 216A
213 214
CLASSROOM
CLASSROOM 216 F S
212
C.0
R C.0 C.0 C.0 C.0
OS C.1
R R R R
B B
C.0
STOR.
215
C.0
C.1 ELEC. C.0
R R R R R R R R R R R 280 R CORRIDOR C.1 S S C.1 S 201C STORAGE STORAGE
OFFICE OFFICE OFFICE EXISTING GWB HEADER TO 212C 212B REMAIN 212A S 219 OS OS 220
C C
C.0 C.1 C.1
CLASSROOM CLASSROOM
WOMEN C.1 209 C.1 C.1 208 OWNERSHIP OF INSTRUMENTS OF SERVICE:
224
All reports, specifications, plans, computer files, field
data, notes, and other documents and instruments
R CORRIDOR of service shall remain the property of the Design
S CORRIDOR 218 Professional. The Design Professional shall retain
F all common law, statutory and other reserved rights,
201B
R OS including the copyright thereto.
F
C.2 R S R S R R R R This drawing is the property of Yates -Chreitzberg -
OS S VESTIBULE C.8 OS F OS OS F OS C.8 CO 2 R 0 R 1 ID D OR E TO XI S R T E I M N A G I N W , I T N Y D P O IC W A S L HADES H co u p g ie h d e s in A w rc h h ol i e te o c r t s an a y n d p a is rt . n I o t t is to n b o e t t r o e p b r e o d u u s c e e d d o o n r
C.1
R 201E C.7 S S C.7 any other project and is to be returned upon request.
C.1 S
STOR. C.1 C.1 (C) Copyright 2024
C.2 C.1
REMOVE EXISTING CEILING MOUNTED 203
PROJECTOR, CAMERA AND SPEAKERS, S C.1 JANITOR
AND RETURN TO OWNER 223 OFFICE OFFICE
222 221
C.0 OS OS
OFFICE
210 MEN
REMOVE EXISTING WALL MOUNTED
225
ROLL DOWN PROJECTION SCREEN C.1 C.1
AND RETURN TO OWNER
C.1
CORRIDOR
ENTRANCE R R R R R R R 201A R R R R R R R R R R
ENTRANCE
200 S S S S S
202
OPEN TO ABOVE OPEN TO ABOVE
D D
R
C.1 R
S S
C.2 S C.2
C.1 R F ELEV. ELEV. R S R R R S R R R S R F R
LOBBY 191
CLASSROOM
C.2 226 C.2 CLASSROOM CLASSROOM
205
207
206
EXISTING GWB HEADER TO REMAIN EXISTING GWB HEADER TO
R R REMAIN
F F OS R
OFFICE OS S S
R
REMOVE EXISTING CEILING 204
TILE, 2x2 GRID TO REMAIN
F OS
R R
R
F S
OS R S R R R R R R S R
E E
REMOVE EXISTING CEILING MOUNTED REMOVE EXISTING CEILING MOUNTED
PROJECTORS AND SPEAKERS, RE-USE PROJECTORS AND SPEAKERS, RE-USE
REMOVE EXISTING CEILING GRID AND IN NEW WORK, SEE SHEET A203 AND IN NEW WORK, SEE SHEET A203
TILE SHOWN DOTTED ELECTRICAL DRAWINGS
REMOVE EXISTING CEILING GRID AND
REMOVE WALL MOUNTED ROLL DOWN TILE SHOWN DOTTED
PROJECTION SCREENS AND RE-USE IN NEW
WORK, SEE SHEET A203
REMOVE EXISTING LIGHT FIXTURES
1 2 3 4 5 6 7 SHOWN DOTTED AND RE-USE IN NEW 8 9 10
WORK, SEE SHEET A202 AND ELECTRICAL
DRAWINGS
N
N
TRUE PLAN
REFLECTED CEILING PLAN KEYED NOTES
CEILING LEGEND
WALL LEGEND
C.0 NO WORK
S SMOKE DETECTOR
C.1 REMOVE EXISTING CEILING TILES, EXISTING GRID TO REMAIN
2x4 RECESSED LED FIXTURE SUPPLY AIR DIFFUSER EXISTING WALL TO BE REMOVED
OS OCCUPANCY SENSOR C.2 REMOVE EXISTING LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS
EXISTING WALL TO REMAIN
RETURN AIR DIFFUSER /
F FIRE ALARM DEVICE C.3 REMOVE EXISTING LIGHT FIXTURE AND RE-USE IN NEW WORK, SEE ELECTRICAL DRAWINGS EXHAUST GRILLE
2x2 RECESSED LED FIXTURE
CAMERA C.4 INFILL NEW CEILING GRID TEES TO MATCH EXISTING FOR 2X2 LAYOUT AND PROVIDE NEW CEILING TILE EXISTING 1 HR RATED WALL TO REMAIN
REFLECTED CEILING BASE BID / ALTERNATE RECESSED LED DOWN LIGHT S SPEAKER WITH GRILLE C.5 NEW LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS
UPRIGHT SPRINKLER HEAD EXISTING 2 HR RATED WALL TO REMAIN
C.6 EXISTING LIGHT FIXTURE RE-USED IN NEW LOCATION, SEE ELECTRICAL DRAWINGS
CEILING MOUNTED LIGHT SPRINKLER HEAD MOUNTED IN CEILING
LINEAR SUPPLY AIR DIFFUSER NEW 1 HR RATED WALL
WORK SHOWN IN THE FOLLOWING ROOMS IS BASE BID. C.7 EXISTING CEILING MOUNTED PROJECTOR TO REMAIN, RELOCATE MOUNT SLIGHTLY AS
NECESSARY TO INSTALL NEW CEILING GRID TEES
INDICATES CEILING MOUNTED DEVICES, SPRINKLER HEADS, ETC. TO BE REMOVED
EXIT SIGN
NEW WALL
204 205 207 210 218 219 220 221 222 C.8 EXISTING WALL MOUNTED ROLL DOWN SCREEN TO REMAIN
R
DIRECTIONAL EXIT SIGN INDICATES CEILING MOUNTED DEVICES, SPRINKLER HEADS, ETC. TO BE RELOCATED NOTE: WALL SYMBOLOGY FOR GRAPHICAL PURPOSES ONLY.
ALL OTHER WORK SHOWN ON THE REFLECTED CEILING PLAN IS TO BE INCLUDED IN ALTERNATE #2 LOCATED IN CENTER OF NEW CEILING TILE, TYPICAL C.9 REMOVE EXISTING WALL MOUNTED ROLL DOWN SCREEN AND RE-USE IN NEW WORK. REFER TO PARTITION TYPES AND WALL SECTIONS FOR ACTUAL
WALL CONSTRUCTION.
202S
gnildiuB
CCCR
snoitavoneR
72082
CN
,drocnoC
|
dR
hcruhC
ytinirT
1351
7035 NORTHWINDS DR NW
CONCORD, NC 28027
704.788.2000
www.ycharch.com
CONSULTANT:
PROFESSIONAL SEALS:
Z B
ERG-HUGHE
S
R E I
T
E D
ARCHITECTURAL
CO R
A
R C H
S - E C T H GI S ER T E R CER 3 T 1 . 0 NO. P O R N O A T I I S T T E C
A , Y A P. NORTHCAROLINA .
CONCORD,
N.
C.
CLIENT:
SCO #22-25351-02A
NCCCS #2692
YCHA COM.#:
PHASE & DATE:
REVISIONS:
SHEET TITLE:
ARCHITECTURAL:
MP
32:20:6
4202/31/4
202S
gnidliuB
CCCR
00.91222\seliF
lacoL
tiveR\:S
tvr.moc.hcrahcy@hllib_snoitavoneR
22219.00
CONSTRUCTION DOCUMENTS
1 SECOND LEVEL REFLECTED CEILING PLAN - DEMOLITION
04-08-24
AD202 3/16" = 1'-0"
SECOND LEVEL
REFLECTED CEILING
PLAN - DEMOLITION
AD202
| S STOR. 310 F S S | S F CLASSROOM 309 C.0 S S STOR. | IDF 381A F R OS OS R OS C.0 R C.7 IDF 381 CLASSROOM 311 C.0 CLASSROOM | F R C.7 C.7 CLASSROOM | ||||||||
| S F S | |||||||||||
| C.7 | |||||||||||
| STOR. 310 | 308B OS OFFICE R 309A C.1 C.0 R R R R C.0 S C.1 C.1 C.1 WOMEN 316 | S S 312 C.7 C.8 C.1 C.1 R R CORRIDOR R R R R S S C.1 301C | 313 C.1 ELEC. R R R 380 S C C.0 S R | C.1 .1 OFFICE OFFICE 314E 314D OS OS | |||||||
| S | S | ||||||||||
| CLASSROOM 308 C.0 OS C.2 C.2 C.2 C.1 ENTRANCE 200 C.2 C.2 C.2 | ASSROOM 308 C.0 | OS | OFFICE 308A OS | C.1 C.2 C.8 VESTIBULE 301E S R C.2 CORRIDOR MEN 301B 315 C.1 C.1 R R R R R S C.1 C.3 C.3 C.2 C.2 R R ELEV. S 391 S S C ELEVATOR C.2 LOBBY C.2 C.3 CLASSROOM C.3 306 300 | R R CLASSROOM CLASSROOM R R C.7 F OS 305 303 OS F C.7 C.1 C.1 | R C.1 OS CORRIDOR C.8 301D OFFICE R 314A OS C.1 C.1 C.1 R R C.2 C.2 C.2 C.2 C.3 R C.2 C.2 | CORRIDOR F 314 R OFFICE OFFICE R OS 314B 314C OS C.1 C.2 C.2 C.2 C.1 ENTRANCE 202 C.2 C.2 C.2 | ||||
| C.2 C.2 C.2 C.2 C.2 C.2 | |||||||||||
| R R R R R CORRIDOR S 301A S C.3 C.3 C.3 C.3 C.3 R R R R R R C.1 S D R S F S S F CLASSROOM D 302 R C C.3 OS C.3 OS |
| CORRI 314 OFFICE 314B | DOR OFFICE 314C |
|---|
| FLECTED CEILING PLAN KEYED NOTES |
|---|
| NO WORK REMOVE EXISTING CEILING TILES, EXISTING GRID TO REMAIN REMOVE EXISTING LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS REMOVE EXISTING LIGHT FIXTURE AND RE-USE IN NEW WORK, SEE ELECTRICAL DRAWINGS INFILL NEW CEILING GRID TEES TO MATCH EXISTING FOR 2X2 LAYOUT AND PROVIDE NEW CEILING TIL NEW LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS EXISTING LIGHT FIXTURE RE-USED IN NEW LOCATION, SEE ELECTRICAL DRAWINGS EXISTING CEILING MOUNTED PROJECTOR TO REMAIN, RELOCATE MOUNT SLIGHTLY AS NECESSARY TO INSTALL NEW CEILING GRID TEES EXISTING WALL MOUNTED ROLL DOWN SCREEN TO REMAIN REMOVE EXISTING WALL MOUNTED ROLL DOWN SCREEN AND RE-USE IN NEW WORK. |
| WALL LEGEND |
|---|
| EXISTING WALL TO BE REMOVED EXISTING WALL TO REMAIN EXISTING 1 HR RATED WALL TO REMAIN EXISTING 2 HR RATED WALL TO REMAIN |
| NEW 1 HR RATED WALL NEW WALL E: WALL SYMBOLOGY FOR GRAPHICAL PURPOSES ONLY. ER TO PARTITION TYPES AND WALL SECTIONS FOR ACTUAL L CONSTRUCTION. |
1 2 3 4 5 6 7 8 9 10
A A
S
IDF
381A
EXISTING WINDOW SHADES
TO REMAIN, TYPICAL
F
CLASSROOM
309
C.0 F R OS OS R
S OS R C.0 F R
EXISTING GWB ON SHAFT AT C.7 C.7 C.7 C.7
ROOF LADDER TO REMAIN
IDF
S 381
CLASSROOM
311 C.0
STOR. CLASSROOM CLASSROOM
308B S S 312 313
OS OFFICE
R
B 309A B
C.7
C.1 C.8 C.1 C.1 C.1
S C.0
NO CEILING WORK IN AREAS
SHOWN SHADED, TYPICAL
ELEC.
C.0 R R S R C.1 R R S R CORRIDOR R R S R C.1 R R R S R 380 C.1 301C
EXISTING GWB HEADER TO C.1 REMAIN
STOR.
310
C C
OFFICE OFFICE
C.0 S 314E 314D
OS OS
C.1 OWNERSHIP OF INSTRUMENTS OF SERVICE:
R
C.1 WOMEN All reports, specifications, plans, computer files, field
F S S 316 CORRIDOR data, notes, and other documents and instruments
R F 314 of service shall remain the property of the Design
CLASSROOM C.1 OS Professional. The Design Professional shall retain
all common law, statutory and other reserved rights,
308 OFFICE
including the copyright thereto.
308A C.1
VESTIBUL C E .2 C.8 C.7 R F R OS CLAS 3 S 0 R 5 OOM CLAS 3 S 0 R 3 OOM R OS R F C.7 C.8 CO 3 R 0 R 1 ID D OR E TO XI S R T E I M N A G I N W , I T N Y D P O IC W A S L HADES T H co h u p i g s ie h d d e r s a in w A w in rc h g h o i l i s e t e t o h c r e t s a p n a r y n o d p p e a is r r t t y . n I o o t t f i s t Y o n a b o te e t s t r o e - p b C r e o h d u re u s i c e t e z d b d o e o n r r g -
301E any other project and is to be returned upon request.
OS S OFFICE R R OFFICE OFFICE R
R 314A OS C.1 C.1 OS 314B 314C OS C.1 (C) Copyright 2024
C.2
C.0
REMOVE EXISTING CEILING
TILE, 2x2 GRID TO REMAIN OS CORRIDOR MEN
301B 315
C.1 C.1
REMOVE EXISTING CEILING
C.1 TILE, 2x2 GRID TO REMAIN
C.1 C.1
C.2 C.2 C.2 C.2 C.2 C.2
R R R R R R R R R R R R
CORRIDOR
C.1 C.2 C.2 S C.1 301A S C.2 C.2 C.1
S
ENTRANCE
ENTRANCE C.2 C.2
202
200
D C.2 C.2 D
C.3 C.3 C.3 C.3 C.3 C.3 C.3 C.3
C.2 C.2 C.2 C.2 C.2 C.2
C.2 C.2 C.2 C.2 R R R R R R R R R C.2 C.2
ELEV. S C.1 S
391
S D R
S S F S S F
C CLASSROOM
EXISTING GWB HEADER TO ELEVATOR EXISTING GWB HEADER TO
REMAIN C.2 LOBBY C.2 C.3 CLAS 3 S 0 R 6 OOM C.3 C.3 D OS C.3 302 R OS C REMAIN 300
C.2 C.2 R C.2 C.2
OS C.3 C.3 C.3
OFFICE
R
307
OS F
CLASSROOM
REMOVE ALL EXISTING DOWNLIGHTS
IN EXTERIOR GWB SOFFIT C.1 304 C.1
S REMOVE ALL EXISTING DOWNLIGHTS
IN EXTERIOR GWB SOFFIT
C.2 C.2 R R R R R R R R R R R R C.2 C.2
F S C.3 C.3 C.3 S
C.3 C.3 C.3 C.3 C.3
C.1 S
E E
REMOVE EXISTING CEILING MOUNTED REMOVE EXISTING CEILING SPEAKERS AND
REMOVE EXISTING CEILING GRID AND TILE REMOVE EXISTING CEILING MOUNTED
PROJECTORS, SPEAKERS AND CAMERAS, CAMERAS, RE-USE IN NEW WORK, SEE ELEC.
SHOWN DOTTED PROJECTORS, SPEAKERS AND CAMERAS,
RE-USE IN NEW WORK, SEE SHEET A203 DWGS., TYPICAL RE-USE IN NEW WORK, SEE SHEET A203
AND ELECTRICAL DRAWINGS
REMOVE WALL MOUNTED ROLL DOWN
REMOVE EXISTING CEILING GRID AND
PROJECTION SCREENS AND RE-USE IN NEW
TILE SHOWN DOTTED
WORK, SEE SHEET A203
WORK IN THIS AREA TO BE ALTERNATE #1
1 2 3 4 5 6 7 REMOVE EXISTING LIGHT FIXTURES 8 9 10
BASE BID FOR EXISTING CLASSROOMS 202, 204 AND 206: SHOWN DOTTED AND RE-USE IN NEW
REMOVE EXISTING CEILING TILES, EXISTING GRID TO REMAIN WORK, SEE SHEET A202 AND ELECTRICAL
DRAWINGS
N
N
TRUE PLAN
REFLECTED CEILING PLAN KEYED NOTES
CEILING LEGEND
WALL LEGEND
C.0 NO WORK
S SMOKE DETECTOR
C.1 REMOVE EXISTING CEILING TILES, EXISTING GRID TO REMAIN
2x4 RECESSED LED FIXTURE SUPPLY AIR DIFFUSER EXISTING WALL TO BE REMOVED
OS OCCUPANCY SENSOR C.2 REMOVE EXISTING LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS
EXISTING WALL TO REMAIN
RETURN AIR DIFFUSER /
F FIRE ALARM DEVICE C.3 REMOVE EXISTING LIGHT FIXTURE AND RE-USE IN NEW WORK, SEE ELECTRICAL DRAWINGS EXHAUST GRILLE
2x2 RECESSED LED FIXTURE
REFLECTED CEILING BASE BID / ALTERNATES CAMERA C.4 INFILL NEW CEILING GRID TEES TO MATCH EXISTING FOR 2X2 LAYOUT AND PROVIDE NEW CEILING TILE EXISTING 1 HR RATED WALL TO REMAIN
RECESSED LED DOWN LIGHT S SPEAKER WITH GRILLE C.5 NEW LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS
UPRIGHT SPRINKLER HEAD EXISTING 2 HR RATED WALL TO REMAIN
WORK SHOWN IN THE FOLLOWING ROOMS IS BASE BID: 307 308A 309A 314 314A 314B 314C 314D 314E C.6 EXISTING LIGHT FIXTURE RE-USED IN NEW LOCATION, SEE ELECTRICAL DRAWINGS
BASE BID FOR EXISTING CLASSROOMS: 302 304 306 CEILING MOUNTED LIGHT SPRINKLER HEAD MOUNTED IN CEILING LINEAR SUPPLY AIR DIFFUSER NEW 1 HR RATED WALL
REMOVE EXISTING CEILING TILES, EXISTING GRID, LIGHTS, DIFFUSERS, ETC. TO REMAIN C.7 EXISTING CEILING MOUNTED PROJECTOR TO REMAIN, RELOCATE MOUNT SLIGHTLY AS
NECESSARY TO INSTALL NEW CEILING GRID TEES
INDICATES CEILING MOUNTED DEVICES, SPRINKLER HEADS, ETC. TO BE REMOVED
EXIT SIGN
NEW WALL
ALTERNATE #1 -REMOVE ALL CEILING GRID, TILE, LIGHTS, DIFFUSERS, ETC. IN ROOMS 302 304 306 C.8 EXISTING WALL MOUNTED ROLL DOWN SCREEN TO REMAIN
R
DIRECTIONAL EXIT SIGN INDICATES CEILING MOUNTED DEVICES, SPRINKLER HEADS, ETC. TO BE RELOCATED NOTE: WALL SYMBOLOGY FOR GRAPHICAL PURPOSES ONLY.
ALL OTHER WORK SHOWN ON THE REFLECTED CEILING PLAN IS TO BE ALTERNATE #2 LOCATED IN CENTER OF NEW CEILING TILE, TYPICAL C.9 REMOVE EXISTING WALL MOUNTED ROLL DOWN SCREEN AND RE-USE IN NEW WORK. REFER TO PARTITION TYPES AND WALL SECTIONS FOR ACTUAL
WALL CONSTRUCTION.
202S
gnildiuB
CCCR
snoitavoneR
72082
CN
,drocnoC
| dR
hcruhC
ytinirT
1351
7035 NORTHWINDS DR NW
CONCORD, NC 28027
704.788.2000
www.ycharch.com
CONSULTANT:
PROFESSIONAL SEALS:
Z B
ERG-HUGHE
S
R E
I
T
E D
ARCHITECTURAL
CO R
A
R
C H
S - E C T H GI S ER T E R CER 3 T 1 . 0 NO. P O R N O A T I I S T T E C
A ,
Y A P. NORTHCAROLINA .
CONCORD, N. C.
CLIENT:
SCO #22-25351-02A
NCCCS #2692
YCHA COM.#:
PHASE & DATE:
REVISIONS:
SHEET TITLE:
ARCHITECTURAL:
MP
53:20:6
4202/31/4
202S
gnidliuB
CCCR
00.91222\seliF
lacoL
tiveR\:S
tvr.moc.hcrahcy@hllib_snoitavoneR
22219.00
CONSTRUCTION DOCUMENTS
1 THIRD LEVEL REFLECTED CEILING PLAN - DEMOLITION
04-08-24
AD203 3/16" = 1'-0"
THIRD LEVEL
REFLECTED CEILING
PLAN - DEMOLITION
AD203
Facility Design Manual
Level 3 This gypsum board finish is typically specified in appearance areas that
will receive heavy or medium texture finishes before final painting or in
areas where heavy-duty commercial-grade wallcoverings will be applied
as the final decoration. Level 3 is not recommended for smooth wall
designs or applications where light textures; non-continuous textures or
lightweight wallcoverings will be applied. After wiping joints with a joint
knife, leaving a thin layer of compound over all joints and interior angles,
add a separate coat of joint compound over all joints and interior angles.
Cover fastener heads and accessories with two layers of joint compound.
Make sure the surface is smooth and free of tool marks.
Level 4 Finish Level 4 is typically specified in appearance areas where smooth
wall designs are going to be decorated with flat paints, light textures or
non-continuous textures or where wallcoverings will be applied. This level
of finish is not recommended in spaces where non-flat or dark/deep-tone
paints are going to be applied. As in previous levels, all joints and interior
angles have tape embedded in the joint compound. After wiping joints with
a joint knife, leaving a thin layer of compound over all joints, add two coats
of joint compound over all flat joints. After wiping interior angles with a joint
knife, leaving a thin layer of compound, add one separate coat of joint
compound over interior angles. Cover fastener heads and accessories
with three layers of joint compound. Make sure the surface is smooth and
free of tool marks. If finishing glass mat or fiber-reinforced gypsum panels,
check with the manufacturer for finishing recommendations.
Level 5 Gypsum board finishing Level 5 is typically specified in appearance areas
where smooth wall designs are decorated with non-flat paints, glossy or
decorative finishes, or dark/deep-tone paints or where critical lighting
conditions occur. Level 5 provides a uniform surface and minimizes the
possibility of joint photographing and/or fasteners showing through the
final decoration. In Level 5, all joints and interior angles have tape
embedded in the joint compound. All joints are then wiped with a joint knife,
leaving a thin layer of compound over all joints and interior angles. Add
two coats of joint compound over all flat joints. Add one coat of joint
compound over interior angles. Cover fastener heads and accessories
with three coats of joint compound. Apply a skim coat of joint compound
or material manufactured for this purpose to the entire surface. Make sure
the surface is smooth and free of tool marks.
3.9.2. Acoustical Tile Ceilings
Acoustical tile ceilings shall be exposed grid, lay-in system. Acoustical tiles shall be two feet square
(2'x2') lay-in tiles composed of non-combustible materials.
3.9.2.1. The standard Acoustical ceiling tile suspension systems shall be wide faces,
double web, steel which are hot-dip galvanized with prefinished 15/16" flanges. They shall be
rated for intermediate duty. Color: White. Acceptable manufacturers are Armstrong, USG,
and Chicago Metallic Corporation.
3.9.2.2. The standard acoustical ceiling tiles shall be 34" thick, white, mineral based, treated
with mold/mildew inhibitor. They shall have a reflectance of no less than LR 0.83, with a Noise
Reduction Coefficient (NRC) of 0.70, and a Ceiling Attenuation Class on not less than 40
Armstrong Tundra, medium texture with tegular edge shall be the basis of design. Acceptable
Issue: November 15, 2020 College Standards Page 3-21
Revised: February 1, 2024
Facility Design Manual
manufacturers are Armstrong, USG, and CertainTeed. 3.9.2.1. USG Frost(TM) ClimaPlus(TM)
#414, 2'x2'x3/4", Shadowline Edge with Bevel - Flat White 050.
3.9.2.3. Open Office and Collaboration spaces will have ceilings with high NRC and CAC
characteristics.
3.9.2.4. Class A "Fire-Rated" materials shall be specified to complete a UL fire-rated ceiling
system for fire protection of structural components, where fire-rated assembly is required by
Code.
3.9.3. Flooring
The following materials are preferred at the locations indicated:
3.9.3.1. Terrazzo or non-slip porcelain tile - high traffic areas such as lobbies and corridors.
At ornamental stairs, treads and risers shall match the adjacent materials with non-slip nosings.
3.9.3.2. Luxury Vinyl Tile (LVT) - low traffic lobbies and corridors, general purpose rooms,
labs, classrooms where appropriate.
3.9.3.3. Carpet Tile - offices, conference rooms, auditorium aisles (with permanent
seating), lounges, classrooms as appropriate, music or language listening rooms.
3.9.3.4. Porcelain Tile - restroom, bathrooms and showers.
3.9.3.5. Quarry Tile or Anti-bacterial Cement - food service areas.
3.9.3.6. Sealed Concrete - mechanical rooms, storage rooms, custodial rooms.
3.9.3.7. Raised, Removable Panels supported on interconnecting grids and pedestals,
providing an under-floor plenum for air distribution and utilities may be utilized in Server Rooms,
and other appropriate spaces.
3.9.3.8. Steel Trowel Finish Concrete - treads and risers with non-slip nosings for service
and egress stairs.
3.9.3.9. Walk- off Carpet Tiles - building entrances.
3.9.4. Tile Carpeting
All carpet shall be selected from the North Carolina Qualified Products List (QPL) established by
the State Purchasing Department.
Light colors (such as white, yellow, or gold) and solid colors which immediately show all traffic
patterns and any stain must be avoided.
All carpet to be 24" x 24" tiles to facilitate replacement of damaged carpet and storage of attic stock.
Use of broadloom carpet must be approved by the College.
All newly carpeted areas shall be appropriately covered with plastic or brown paper to protect the
carpet from construction debris. Carpet shall be in clean, like new condition when turned over to
the College.
Tile carpeting with a hard composition backing, but not containing PVC, is preferred for public
spaces where floor access is desirable and for ease of repair. A mixed pattern with high soil and
stain hiding capabilities is preferred.
3.9.4.1. Carpet Specification Requirements
Issue: November 15, 2020 College Standards Page 3-22
Revised: February 1, 2024

With GovernmentContracts, you can:
.... he scope also includes the replacement of two (2) garage doors, a ...
State Government of North Carolina
Bid Due: 9/29/2026
...items: Demolition and replacement of all bathroom fixtures and accessories, finishes, lighting... Description: ...
State Government of North Carolina
Bid Due: 9/17/2026
...and replacement recommendations, and provide equipment replacement, upgrades, and maintenance services... McMillan Description ...
State Government of North Carolina
Bid Due: 9/21/2026
...Resources Description: Tryon Palace Perimeter Fence Replacement Phase 1 Opening Date: 9/29/2026 3:00 ...
State Government of North Carolina
Bid Due: 9/29/2026