J049--AMENDMENT 0001 TO RFQ 36C24526Q0401 UPLOADED ANSWERS TO RFIS AND GENERATOR DESCRIPTIONS LOUIS A JOHNSON VAMC
| Location: |
West Virginia |
| Posted: |
Apr 8, 2026 |
| Due: |
Apr 14, 2026 |
| Agency: |
VETERANS AFFAIRS, DEPARTMENT OF |
| Type of Government: |
Federal |
| Category: |
- J - Maintenance, Repair, and Rebuilding of Equipment
|
| Solicitation No: |
36C24526Q0401 |
| Publication URL: |
To access bid details, please log in. |
J049--AMENDMENT 0001 TO RFQ 36C24526Q0401 UPLOADED ANSWERS TO RFIS AND GENERATOR DESCRIPTIONS LOUIS A JOHNSON VAMC
Active
Contract Opportunity
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
245-NETWORK CONTRACT OFFICE 5 (36C245)
Looking for contract opportunity help?
General Information View Changes
-
Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
-
Updated Published Date: Apr 08, 2026 07:44 am EDT
-
Original Published Date: Mar 26, 2026 03:44 pm EDT
-
Updated Date Offers Due: Apr 14, 2026 10:00 am EDT
-
Original Date Offers Due: Apr 14, 2026 10:00 am EDT
-
Inactive Policy: Manual
-
Updated Inactive Date: May 14, 2026
-
Original Inactive Date:
May 19, 2026
-
Initiative:
Classification
Description View Changes
GENSET #1
GENSET #2
GENSET #3
Manufacturer/Make/Year:
Caterpillar
Caterpillar
Kato
Model No:
SR-4
C32
500SS9D
Serial/Order No:
6NA01031
G1G00044
7319
Load Rating:
(Emergency/Standby/Prime)
1000 kva
1250 kva
625KVA
Power Factor:
.8
.8
.8
Frequency:
60 Hertz
60 Hertz
60 hertz
Load in Amperage:
1000 amps
1000 amps
87
Output Voltage:
480
480 volts
4160 volts
Phase:
3-phase
3-phase
3-phase
Building:
Bld 17
Bld 17
Bld 17
Location (Area/Room):
Generator room
Generator Rm
Generator Rm
GENSET #4
GENSET #5 (portable)
Manufacturer/Make/Year:
Kohler
Baldor
Model No:
100RE0ZJF
TS225-3J
Serial/Order No:
3346GMJL0001
P1205240012
Load Rating:
(Emergency/Standby/Prime)
128 kva
225 kva
Power Factor:
.8
.8
Frequency:
60 Hertz
60 Hertz
Load in Amperage:
153 amps
625 amps
Output Voltage:
480
480 volts
Phase:
3-phase
3-phase
Building:
Parking Garage
Grounds
Location (Area/Room):
Parking Garage
Grounds (portable)
Who will be responsible for the generator maintenance (monthly, quarterly, semi, annual, & triennial) an when was the last time the annual maintenance was completed?
Mountaineer Generator.
When was the last annual load bank testing conducted?
             3/28/26.
Does the KATO 500kW (625KVA) 4160v generator have an integrated load bank?
NO
Attachments/Links
Contact Information
Contracting Office Address
-
8849 International Drive Suite 215
-
LINTHICUM , MD 21090
-
USA
Secondary Point of Contact
History
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.