WHITEWATER HIGH SCHOOL RENOVATIONS 10/22/26
FAYETTE COUNTY SCHOOLS
PBK PN 240477
ITB 27-004-075
PBK, P.O. BOX 880, GRIFFIN, GA 30223
ADDENDUM NUMBER FOUR: DATED: October 22, 2026
To: All prime contract bidders of record.
This addendum forms a part of the Contract Documents and modifies the original Specifications
and Drawings dated September 11, 2026, as noted below. Acknowledge receipt of this
Addendum in the space provided on the Bid Form; failure to do so may subject bidder to
disqualification.
BID DATE: November 5, 2026
Note: A copy of the Pre-Bid Attendance Roster from the Non-mandatory Pre-Bid conference that
was held on Thursday October 15, 2026 is attached for reference.
SPECIFICATIONS
1. Section 042000 - UNIT MASONRY
A. Part 2 Products; Section 2.6
1. Delete line 2.6.B.3 - "Size (Actual Dimensions): 3-5/8 inches (92mm) wide by 2-
1/4 inches (57mm) high by 7-5/8 inches (194mm) long. Revise to read: Size
(Actual Dimensions): 3-5/8 inches (92mm) wide by 3-5/8 inches (92mm) high by
11-5/8 inches (295mm) long.
2. Section 055214 - STAINLESS STEEL TUBE RAILINGS
A. Add this specification section included in this addendum to the project manual.
1. The section includes instructions regarding stainless steel handrails featured
atop the low walls in the serving line area 719.13.
3. Section 096513 - RESILIENT BASE AND ACCESSORIES
A. Part 2 Products; Section 2.2
1. Delete line 2.2.D - "Height: 4 inches (101.4 mm). Use 6 inches (152.4mm) at
locker bases", Revise to read: "Height: 6 inches (152.4mm):"
4. Section 123550.53 - WOOD-VENEER-FACED LIBRARY CASEWORK
A. Delete this section in its entirety and replace with section 123550.53 - VENEER-FACED
LIBRARY CASEWORK included within this addendum.
1. Revisions to casework for the media center also reflected in reissuance of Sheet
A-401 later in this addendum.
5. Section 133419 - METAL BUILDING SYSTEMS
A. Part 1 General; Section 1.12
1. Delete Paragraph 1.12.B its entirety.
6. Section 142400 - HYDRAULIC ELEVATORS
A. Add this specification section included in this addendum to the project manual.
1. The section includes instructions regarding interior finishes for the interior cabin
of the existing gymnasium elevator.
Addendum No. 4 - Page 1 of 6
WHITEWATER HIGH SCHOOL RENOVATIONS 10/22/26
FAYETTE COUNTY SCHOOLS
PBK PN 240477
7. Section 270500 - COMMON WORK RESULTS FOR COMMUNICATIONS
A. On page 1, add the following as paragraph 1.2.4.:
"4. Section 271423 - Auditorium Audio-Visual Systems
a. Product data
b. Shop drawings
c. Equipment list
d. Field quality control test reports"
8. Section 271423 - Auditorium Audio Visual Systems
A. Add this specification section included in this addendum to the project manual.
1. This section includes instructions for new audio-visual systems in the existing
auditorium.
DRAWINGS
ARCHITECTURAL
1. SHEET G-020 - ACCESSIBILITY STANDARDS
A. Detail No.4 - TYP CUSTODIAL CLOSET;
1. Delete note and graphic relating to "PLASTIC TRIM"
2. Delete note and graphic relating to "WALL PROTECTION"
2. SHEET AD-101.1 - DEMOLITION FLOOR PLAN - SECTOR A-F
A. Add demo keynote "D1" to the following spaces: 919, 1004.1, 1015, 1019
B. Add demo keynote "D4" to the following space: 716.1
3. SHEET AD-101.2 - DEMOLITION FLOOR PLAN - SECTOR G,H,I,K
A. Space Attendance 402 - In plan orientation, delete red linework indicating partial
demolition of the wall on the right side of space adjacent to Corridor 400.
4. SHEET AD-101.3 - DEMOLITION FLOOR PLAN - SECTOR L,J,H.LL,K.LL
A. Add demo keynote "D1" to the following spaces: 507, 507.1, 507.2, 507.3, 850.2
5. SHEET A101I - FLOOR PLAN - SECTOR I
A. Keynote Legend, No.23 - "CONCRETE SIDEWALK. REFER TO CIVIL." Revise
to read "CONCRETE SIDEWALK"
B. At all locations of new CMU adjacent to new trophy cases; Delete partition type
tag "M4.C", Replace with partition type tag "M6.C"
Addendum No. 4 - Page 2 of 6
WHITEWATER HIGH SCHOOL RENOVATIONS 10/22/26
FAYETTE COUNTY SCHOOLS
PBK PN 240477
6. SHEET A101J - FLOOR PLAN - SECTOR J
A. Add Keynote 22 - "REPLACE SLIP-RESISTANT MATERIAL STAIR NOSING" to
all stair locations in the following spaces: 503 & 507
7. SHEET A-101AA - BATTING FACILITY FLOOR PLAN & CEILING PLAN
A. Detail No.6 - PLAN DETAIL
1. Delete 1'-8" and 1'-5" measured dimensions
2. Delete note: "7 5/8" LIGHT GUAGE MTL STUD FRAMING
8. SHEET A-401 - ENLARGED MEDIA CENTER FLOOR PLAN
A. Delete Sheet A-401 in its entirety and replace with Sheet A-401 included in this
addendum.
9. SHEET A-407 - ENLARGED TOILET PLANS
A. Detail No.2 - ENLARGED TOILET PLAN; See revisions to detail on SDA-407
included in this addendum.
1. Revision Include the addition of a chase wall in Restroom 2 to
accommodate plumbing scope.
B. Add Detail No.7 - SECTION DETAIL included on SDA-407 included in this
addendum.
1. Section detail for chase wall in Restroom 2 noted above.
10. SHEET A-502AA - BATTING FACILITY EXTERIOR ELEVATIONS & ROOF PLAN
A. Detail No.10 - WALL SECTION; Delete and replace with detail No.10 - WALL
SECTION provided on Supplementary drawing SDA-502AA included in this
Addendum.
B. General Elevation Notes; Note 13: "DOWNSPOUTS SHALL HAE 16 GUAGE
PRE-FINISHED DOWNSPOUT BOOTS TO 6'-0" ABOVE FINISH GRADE.
COLOR SELECTED BY ARCHITECT." Revise to Read: "DOWNSPOUTS
SHALL HAE 12 GUAGE PRE-FINISHED DOWNSPOUT BOOTS TO 2'-4"
ABOVE FINISH GRADE. COLOR SELECTED BY ARCHITECT."
11. SHEET A-810 - DOOR SCHEDULE
A. Door Number C29; Add "PAIR" to SNGL OR PAIR Column.
B. Door Number C37; Add "PAIR" to SNGL OR PAIR Column.
C. Door Number F90; Door Material; "WD" Revise to Read "HM"
Addendum No. 4 - Page 3 of 6
WHITEWATER HIGH SCHOOL RENOVATIONS 10/22/26
FAYETTE COUNTY SCHOOLS
PBK PN 240477
12. SHEET A-812 - SIGN SCHEDULE AND DETAILS
A. Door Number F03, Room 915: Add Sign Type "B3"
B. Door Number J15, Room 504: Delete Sign Type "B1". Add Sign Type "B2"
C. General Graphics Notes; Add Note 18: "INSTALL SIGN TYPE "F" AT
ELEVATOR - 2 INSTANCES"
D. General Graphics Notes; Add Note 19: "INSTALL SIGN TYPE "G" IN THE
FOLLOWING SPACES: 507. 523, 601, 817, AND 1023.
E. General Graphics Notes: Add Note 20: "INSTALL SIGN TYPE "K" ON BUILDING
ENTRANCES/EXITS - (12 INSTANCES) - COORDINATE WITH OWNER ON
LOCATIONS."
13. SHEET A-813 - SITE SIGNAGE PLAN
A. Detail No.2 - SECTION DETAIL; Note "METAL COMPOSITE PANELS", Revise
to read: "PAINTED ALUMINUM PANELS"
B. Detail No.5 - SIGN ELEVATION; Note "METAL COMPOSITE PANELS", Revise
to read: "PAINTED ALUMINUM PANELS"
14. SHEET A-901G-K - FINISH FLOOR PLAN - SECTOR G,H,I,K
A. Toil. 820.2; Entire space to be "RSN" including area where lockers are located.
15. SHEET A-902 - FINISH FLOOR PLAN - ALTERNATE NO.1
A. Delete Sheet A-902 in its entirety and replace with Sheet A-902 included in this
addendum.
16. SHEET A-903 - GYMNASIUM COURT MARKINGS
A. Detail No.1 - LOWER LEVEL - AREA H FLOOR PLAN: Add Note to the center
circle of the main basketball court that reads: "SCHOOL LOGO - COORDINATE
WITH OWNER ON GRAPHIC AND SIZE"
B. Detail No.2 - 94' MAIN BASKETBALL COURT - DIMENSION PLAN: Add note to
the center of the court that reads: "SCHOOL LOGO - COORDINATE WITH
OWNER ON GRAPHIC AND SIZE"
17. SHEET A-921 - WALL FINISH SCHEDULE
A. Finish Schedule Notes and Remarks; Remark No.1 "ALL ROOMS HAVE 4"
RUBBER BASE U.N.O." Revise to read: ALL ROOMS HAVE 6" RUBBER BASE
U.N.O."
Addendum No. 4 - Page 4 of 6
WHITEWATER HIGH SCHOOL RENOVATIONS 10/22/26
FAYETTE COUNTY SCHOOLS
PBK PN 240477
PLUMBING
1. SHEET P-101AC - PLUMBING FLOOR PLANS - FOOTBALL FIELD HOUSE
A. Delete Sheet P-101AC in its entirety and replace with Sheet P-101AC, included
in this addendum.
MECHANICAL
1. SHEET M-502 - MECHANICAL DETAILS
A. Delete Sheet M-502 in its entirety and replace with Sheet M-502, included in this
addendum.
ELECTRICAL
1. ED101 - OVERALL ELECTRICAL DEMOLITION PLAN
A. Delete Sheet ED-101 in its entirety and replace with Sheet ED-101, included in
this addendum.
2. E-001 - ELECTRICAL OVERALL CAMPUS PLAN
A. Delete Sheet E-001 in its entirety and replace with Sheet E-001, included in this
addendum.
3. E-101K.LL - ELECTRICAL LIGHTING LOWER LEVEL - AREA K FLOOR PLAN
A. Delete Sheet E-101K.LL in its entirety and replace with Sheet E-101K.LL,
included in this addendum.
4. E-201E - ELECTRICAL POWER LEVEL 1 - AREA E FLOOR PLAN
A. Delete Sheet E-201E in its entirety and replace with Sheet E-201E, included in
this addendum.
5. E-201H.LL - ELECTRICAL POWER LOWER LEVEL - AREA H FLOOR PLAN
A. Delete Sheet E-201H.LL in its entirety and replace with Sheet E-201H.LL,
included in this addendum.
6. E-201I - ELECTRICAL POWER LEVEL 1 - AREA I FLOOR PLAN
A. Delete Sheet E-201I in its entirety and replace with Sheet E-201I, included in this
addendum.
7. E-201J - ELECTRICAL POWER LEVEL 1 - AREA J FLOOR PLAN
A. Delete Sheet E-201J in its entirety and replace with Sheet E-201J, included in
this addendum.
8. E-201K - ELECTRICAL POWER LEVEL 1 - AREA K FLOOR PLAN
A. Delete Sheet E-201K in its entirety and replace with Sheet E-201K, included in
this addendum.
Addendum No. 4 - Page 5 of 6
WHITEWATER HIGH SCHOOL RENOVATIONS 10/22/26
FAYETTE COUNTY SCHOOLS
PBK PN 240477
9. E-201K.LL - ELECTRICAL POWER LOWER LEVEL - AREA K FLOOR PLAN
A. Delete Sheet E-201K.LL in its entirety and replace with Sheet E-201K.LL,
included in this addendum.
10. E-301A - ELECTRICAL LOW VOLTAGE LEVEL 1 - AREA A FLOOR PLAN
A. Delete Sheet E-301A in its entirety and replace with Sheet E-301A, included in
this addendum.
11. E-301E - ELECTRICAL LOW VOLTAGE LEVEL 1 - AREA E FLOOR PLAN
A. Delete Sheet E-301E in its entirety and replace with Sheet E-301E, included in
this addendum.
12. E-301H - ELECTRICAL LOW VOLTAGE LEVEL 1 - AREA H FLOOR PLAN
A. Delete Sheet E-301H in its entirety and replace with Sheet E-301H, included in
this addendum.
13. E-301H.LL - ELECTRICAL LOW VOLTAGE LOWER LEVEL - AREA H FLOOR PLAN
A. Delete Sheet E-301H.LL in its entirety and replace with Sheet E-301H.LL,
included in this addendum.
14. E-301J - ELECTRICAL LOW VOLTAGE LEVEL 1 - AREA J FLOOR PLAN
A. Delete Sheet E-301J in its entirety and replace with Sheet E-301J, included in
this addendum.
15. E-501 - ELECTRICAL STAGE LIGHTING
A. Delete Sheet E-501 in its entirety and replace with Sheet E-501, included in this
addendum.
16. E-502 - ELECTRICAL STAGE LIGHTING RISER DIAGRAM
A. Delete Sheet E-502 in its entirety and replace with Sheet E-502, included in this
addendum.
17. E-701 - ELECTRICAL SCHEDULES
A. Delete Sheet E-701 in its entirety and replace with Sheet E-701, included in this
addendum.
18. E-801 - ELECTRICAL SCHEDULES
A. Delete Sheet E-801 in its entirety and replace with Sheet E-801, included in this
addendum.
Addendum No. 4 - Page 6 of 6
PBKArchitectsGeorgia,P.C. WhitewaterHighSchool-Renovations
PBKProjectNo.240477 FayetteCountySchools
AddendumNo.4 2026-10-21
SECTION055214-STAINLESSSTEELTUBERAILINGS
PART1GENERAL
1.1 SUMMARY
A. SectionIncludes:
1. Stainlesssteelrailings.
1.2 COORDINATION
A. Coordinateinstallationofanchoragesforrailings.Furnishsettingdrawings,templates,and
directionsforinstallinganchorages,includingsleeves,concreteinserts,anchorbolts,anditems
withintegralanchors,thataretobeembeddedinconcreteormasonry.Deliversuchitemsto
Projectsiteintimeforinstallation.
1.3 ACTIONSUBMITTALS
A. ProductData:
1. Fasteners.
2. Post-installedanchors.
3. Nonshrink,nonmetallicgrout.
4. Anchoringcement.
5. Metalfinishes.
B. ShopDrawings:Includeplans,elevations,sections,details,andattachmentstootherwork.
1.4 INFORMATIONALSUBMITTALS
A. Weldingcertificates.
B. MillCertificates:Signedbymanufacturersofstainlesssteelproducts,certifyingthatproducts
furnishedcomplywithrequirements.
1.5 QUALITYASSURANCE
A. WeldingQualifications:Qualifyproceduresandpersonnelinaccordancewiththefollowing:
1. AWSD1.6/D1.6M,"StructuralWeldingCode-StainlessSteel."
1.6 DELIVERY,STORAGE,ANDHANDLING
A. Protectmechanicalfinishesonexposedsurfacesofrailingsfromdamagebyapplyinga
strippable,temporaryprotectivecoveringbeforeshipping.
1.7 FIELDCONDITIONS
A. FieldMeasurements:Verifyactuallocationsofwallsandotherconstructioncontiguouswith
railingsbyfieldmeasurementsbeforefabrication.
PART2PRODUCTS
2.1 METALS,GENERAL
A. MetalSurfaces,General:Providematerialswithsmoothsurfaces,withoutseammarks,roller
marks,rolledtradenames,stains,discolorations,orblemishes.
2.2 STAINLESSSTEELRAILINGS
A. SourceLimitations:Obtaineachtypeofrailingfromsinglesourcefromsinglemanufacturer.
B. Tubing:ASTMA554,Grade MT 304.
C. PlateandSheet:ASTMA240/A240MorASTM A666,Type 304.
2.3 FASTENERS
A. FastenerMaterials:
1. StainlessSteelRailingComponents:Type 304stainlesssteelfasteners.
2. Finishexposedfastenerstomatchappearance,includingcolorandtexture,ofrailings.
055214- StainlessSteelTubeRailings
1
PBKArchitectsGeorgia,P.C. WhitewaterHighSchool-Renovations
PBKProjectNo.240477 FayetteCountySchools
AddendumNo.4 2026-10-21
B. FastenersforAnchoringRailingstoOtherConstruction:Selectfastenersoftype,grade,and
classrequiredtoproduceconnectionssuitableforanchoringrailingstoothertypesof
constructionandcapableofwithstandingdesignloads.
C. FastenersforInterconnectingRailingComponents:
1. Provideconcealedfastenersforinterconnectingrailingcomponentsandforattaching
themtootherwork,unlessotherwiseindicated.
2. Provideconcealedfastenersforinterconnectingrailingcomponentsandforattaching
themtootherwork,unlessexposedfastenersareunavoidableorarethestandard
fasteningmethodforrailingsindicated.
3. Providetamper-resistantflat-headmachinescrewsforexposedfastenersunless
otherwiseindicated.
D. Post-InstalledAnchors:Fastenersystemswithworkingcapacitygreaterthanorequaltothe
designload,accordingtoanevaluationreportacceptabletoauthoritieshavingjurisdiction,
basedonICC-ESAC193orICC-ESAC308.
1. Material:AlloyGroup 1stainlesssteelbolts,ASTMF593,andnuts,ASTMF594.
2.4 MISCELLANEOUSMATERIALS
A. WeldingRodsandBareElectrodes:SelectinaccordancewithAWSspecificationsformetal
alloywelded.
1. Forstainlesssteelrailings,providetypeandalloyasrecommendedbyproducerofmetal
tobeweldedandasrequiredforcolormatch,strength,andcompatibilityinfabricated
items.
B. Nonshrink,NonmetallicGrout:Factory-packaged,nonstaining,noncorrosive,nongaseous
grout,complyingwithASTMC1107/C1107M.Providegroutspecificallyrecommendedby
manufacturerforinteriorapplications.
C. AnchoringCement:Factory-packaged,nonshrink,nonstaining,hydraulic-controlledexpansion
cementformulationformixingwithwateratProjectsitetocreatepourableanchoring,patching,
andgroutingcompound.
2.5 FABRICATION
A. General:Fabricaterailingstocomplywithrequirementsindicatedfordesign,dimensions,
membersizesandspacing,details,finish,andanchorage.
B. Shopassemblerailingstogreatestextentpossibletominimizefieldsplicingandassembly.
Disassembleunitsonlyasnecessaryforshippingandhandlinglimitations.
1. Clearlymarkunitsforreassemblyandcoordinatedinstallation.
2. Useconnectionsthatmaintainstructuralvalueofjoinedpieces.
C. Cut,drill,andpunchmetalscleanlyandaccurately.
1. Removeburrsandeaseedgestoaradiusofapproximately1/32inch(0.79mm)unless
otherwiseindicated.
2. Removesharporroughareasonexposedsurfaces.
D. Formworktruetolineandlevelwithaccurateanglesandsurfaces.
E. Cut,reinforce,drill,andtapasindicatedtoreceivefinishhardware,screws,andsimilaritems.
F. Connections:Fabricaterailingswithweldedconnectionsunlessotherwiseindicated.
G. WeldedConnections:Copecomponentsatconnectionstoprovideclosefit,orusefittings
designedforthispurpose.Weldallaroundatconnections,includingatfittings.
1. Usematerialsandmethodsthatminimizedistortionanddevelopstrengthandcorrosion
resistanceofbasemetals.
2. Obtainfusionwithoutundercutoroverlap.
3. Removefluximmediately.
055214- StainlessSteelTubeRailings
2
PBKArchitectsGeorgia,P.C. WhitewaterHighSchool-Renovations
PBKProjectNo.240477 FayetteCountySchools
AddendumNo.4 2026-10-21
4. Atexposedconnections,finishexposedweldstocomplywithNOMMA's"VoluntaryJoint
FinishStandards"forFinish #1welds;ornamentalqualitywithnoevidenceofawelded
joint.
H. NonweldedConnections:Connectmemberswithconcealedmechanicalfastenersandfittings.
Fabricatemembersandfittingstoproduceflush,smooth,rigid,hairlinejoints.
1. Fabricatesplicejointsforfieldconnection,usinganepoxystructuraladhesive,ifthisis
manufacturer'sstandardsplicingmethod.
I. Formchangesindirectionasfollows:
1. Bybending.
J. Bendmembersinjigstoproduceuniformcurvatureforeachconfigurationrequired.Maintain
crosssectionofmemberthroughoutentirebendwithoutbuckling,twisting,cracking,or
otherwisedeformingexposedsurfacesofcomponents.
K. Closeexposedendsofhollowrailingmemberswithprefabricatedcapandendfittingsofsame
metalandfinishasrailings.
L. Providewallreturnsatendsofwall-mountedhandrailsunlessotherwiseindicated.Closeends
ofreturnsunlessclearancebetweenendofrailandwallis1/4inch(6.35mm)orless.
M. Provideinsertsandotheranchoragedevicesforconnectingrailingstoconcreteormasonry
work.
1. Fabricateanchoragedevicescapableofwithstandingloadsimposedbyrailings.
2. Coordinateanchoragedeviceswithsupportingstructure.
N. Forrailingpostssetinconcrete,providestainlesssteelsleevesnotlessthan6inches(152.4
mm)longwithinsidedimensionsnotlessthan1/2inch(12.7mm)greaterthanoutside
dimensionsofpost,withmetalplateformingbottomclosure.
2.6 STAINLESSSTEELFINISHES
A. SurfacePreparation:Removetoolanddiemarksandstretchlines,orblendintofinish.
B. PolishedFinishes:Grindandpolishsurfacestoproduceuniformfinish,freeofcrossscratches.
1. Rungrainwithlongdimensionofeachpiece.
2. Whenpolishingiscompleted,passivateandrinsesurfaces.
3. Removeembeddedforeignmatterandleavesurfaceschemicallyclean.
C. StainlessSteelPipeandTubingFinishes:
1. 320-GritPolishedFinish:Oil-ground,uniform,fine,directionallytexturedfinish.
D. StainlessSteelSheetandPlateFinishes:
1. DirectionalSatinFinish:ASTM A480/A480,No. 4.
PART3EXECUTION
3.1 INSTALLATION,GENERAL
A. Performcutting,drilling,andfittingrequiredforinstallingrailings.
1. Fitexposedconnectionstogethertoformtight,hairlinejoints.
2. Installrailingslevel,plumb,square,truetoline;withoutdistortion,warp,orrack.
3. Setrailingsaccuratelyinlocation,alignment,andelevation;measuredfromestablished
linesandlevels.
4. Donotweld,cut,orabradesurfacesofrailingcomponentsthatarecoatedorfinished
afterfabricationandthatareintendedforfieldconnectionbymechanicalorothermeans
withoutfurthercuttingorfitting.
5. Setpostsplumbwithinatoleranceof1/16inch(1.59mm)in3feet(91.44cm).
B. Adjustrailingsbeforeanchoringtoensurematchingalignmentatabuttingjoints.
055214- StainlessSteelTubeRailings
3

With GovernmentContracts, you can:
Follow Cross Over Network Waveguide Assembly Qualification and Production (P/Ns G638416-1) Active Contract
DEPT OF DEFENSE
Bid Due: 11/18/2026
Follow Repair/Overhaul of Flat Panel Up Front Controller (FPUFC) Active Contract Opportunity Notice
DEPT OF DEFENSE
Bid Due: 11/25/2026
Event ID Event Title Government Entity Start Date (ET) End Date (ET) PE-33658-NONST-2027-000000006
State Government of Georgia
Bid Due: 11/23/2026
Event ID Event Title Government Entity Start Date (ET) End Date (ET) PE-77035-NONST-2027-000000047
State Government of Georgia
Bid Due: 11/19/2026