6515--PND 10-31-2025 Actionable-436-S/S high Fidelity manikin (VA-25-00094659)
| Location: |
Montana |
| Posted: |
Sep 24, 2025 |
| Due: |
Oct 3, 2025 |
| Agency: |
VETERANS AFFAIRS, DEPARTMENT OF |
| Type of Government: |
Federal |
| Category: |
- 65 - Medical, Dental, and Veterinary Equipment and Supplies
|
| Solicitation No: |
36C25925Q0822 |
| Publication URL: |
To access bid details, please log in. |
6515--PND 10-31-2025 Actionable-436-S/S high Fidelity manikin (VA-25-00094659)
Active
Contract Opportunity
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
NETWORK CONTRACT OFFICE 19 (36C259)
Looking for contract opportunity help?
General Information
-
Contract Opportunity Type: Sources Sought (Original)
-
Original Published Date: Sep 24, 2025 09:00 am MDT
-
Original Response Date: Oct 03, 2025 12:00 pm MDT
-
Inactive Policy: Manual
-
Original Inactive Date:
Dec 02, 2025
-
Initiative:
Classification
Description
Sources Sought Notice HI-FIDELITY MANIKIN
DISCLAIMER
This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
Response Instructions:
Do not provide more than 8 pages, including cover letter page.
Submit your response via email to: barron.long@va.gov
Submit your response NLT 12:00 (MST) on Friday, October 3rd 12:00 local mountain time
Mark your response as Proprietary Information if the information is considered business sensitive.
VA has identified the appropriate North American Industry Classification System (NAICS) Code 339112 Surgical and Medical Instrument Manufacturing with a Small Business size of 1000 employees. Please identify and explain any NAICS codes your company believes would better represent the predominated work included in the attached Statement of Work draft / Salient Characteristics List;
Information Requested from Industry:
In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.
Vendor Name:
SAM UEI #:
Name of Manufacturer:
Manufacturer Address:
Manufacturing Country of Origin
Estimated Delivery Time:
___________________________________________________
SAC FSS contract number
Vendor Point of Contract (POC) Name
POC Phone Number:
POC Email Address:
STATEMENT OF WORK
REQUIREMENT
-What is this requirement for? High fidelity manikin (HFM) for mock code training
-Reason requirement is needed:
-Situation-Directive 1177 Cardiopulmonary Resuscitation maintains policy to optimize patient safety for those requiring resuscitation within the Department of VA health care system. The Resuscitation Education and Innovation (REdI) program is the official VHA national program which provides enterprise-wide oversight and support. REdI requires a mock code program is implemented across all areas of the VA medical facility
-What will the period of performance be for this requirement? One time purchase
-Assessment-HFM is needed to adhere to Directive 1177 and the REdI program by providing training to optimize patient safety
-Recommendation-Ensure a HFM in working order is available to continue to comply with the Directive and REdI requirements. Current HFM is at end of life.
-Quantities (equipment only): 1 Manikin
DELIVERY INFORMATION
Montana VAHCS: Fort Harrison VAMC
3687 Veteran s Drive, Bldg. 150, room 107
Fort Harrison, MT 59636
Salient Characteristics
The High Fidelity Manikin (HFM) needs to demonstrate the following:
Spontaneous breathing with unilateral and bilateral chest rise and fall.
Allow for bilateral needle decompressions
Allow for oral and nasal endotracheal intubation with right main stem detection
Allow for bilateral needle decompression of lungs
Show 4-lead and 12-lead cardiac rhythms
Allow for unilateral blood pressure measurement by auscultation and palpitation
Bilateral carotid and femoral pulses, with variable intensity control
Unilateral radial and brachial pulses, with variable intensity control
Auscultation of normal and abnormal heart, lung and bowel sounds
Audible Korotkoff sounds generated with NIBP
Two-way communication between manikin and facilitator
Prerecorded speed and vocal sounds
Interchangeable genitalia
Urinary catheterization without fluids
IV/IO arm and a NIBP/pulse arm
4 intramuscular injection sites
Articulating range of motion in hips, knees, ankles, shoulders
Must be able to be cleaned with PDF Purple top wipes for disinfection.
HFM needs to be compatible with CAE Maestro software
Attachments/Links
Contact Information
Contracting Office Address
-
6162 S WILLOW DR SUITE 300
-
Greenwood Village , CO 80111
-
USA
Secondary Point of Contact
History
-
Sep 24, 2025 09:00 am MDTSources Sought (Original)
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
See also
...FA462620D0011 - Geranios Enterprises, Inc. FA462620D0012 - Guy Tabacco Construction Company FA462620D0013..., Inc. ...
DEPT OF DEFENSE
Bid Due: 6/18/2026
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.