TRAIL BRIDGE BLACKLAND PRAIRIE
| Location: |
Federal |
| Posted: |
Jul 16, 2025 |
| Due: |
Jul 17, 2025 |
| Agency: |
INTERIOR, DEPARTMENT OF THE |
| Type of Government: |
Federal |
| Category: |
- M - Operation of Government Owned Facilities
|
| Solicitation No: |
140P5225R0018 |
| Publication URL: |
To access bid details, please log in. |
M--TRAIL BRIDGE BLACKLAND PRAIRIE
Active
Contract Opportunity
Department/Ind. Agency
INTERIOR, DEPARTMENT OF THE
Sub-tier
NATIONAL PARK SERVICE
Office
SER WEST(52000)
Looking for contract opportunity help?
General Information View Changes
-
Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
-
Updated Published Date: Jul 16, 2025 11:28 am CDT
-
Original Published Date: Jul 01, 2025 11:51 am CDT
-
Updated Date Offers Due: Jul 17, 2025 02:00 pm CDT
-
Original Date Offers Due: Jul 15, 2025 02:00 pm CDT
-
Inactive Policy: Manual
-
Updated Inactive Date: Jul 16, 2026
-
Original Inactive Date:
Jul 07, 2026
-
Initiative:
Classification
-
Original Set Aside:
-
-
Product Service Code: M1LB - OPERATION OF HIGHWAYS, ROADS, STREETS, BRIDGES, AND RAILWAYS
-
NAICS Code:
-
237310 - Highway, Street, and Bridge Construction
-
Place of Performance:
Description View Changes
Amendment 0002: Amendment 0002 We had a few questions so we are sharing the answers below. All other terms, conditions, and times remain the same. BIDS ARE DUE JULY 17,2025 AT 2:00CT.
One question, I noticed the highlighted area regarding delegated design on pdf page 2. Does this mean that minor design details can be delegated to the contractor? The delegated design would be for the pre-fabricated bridges. Those are the only elements that are not ¿designed¿ since they will be built by a manufacturer.
Can the diaphragms be bolted instead of welded to the girders? Yes they can.
Does the diaphragm connection bracket need to be on both sides of the diaphragm in addition to each end of the diaphragm? Yes
Do the bearing plates need to be welded to the girders? Yes they do.
Do the hardware, girders, bearing plates, diaphragms, nailer angle need to be coated in any way? It would be best if they were to minimize corrosion over time. They can be galvanization (zinc coated), epoxy coated, or powder coated
Do we need to include the steel angle nailer bracket if so please provide the spacing? The nailers are spaced a maximum of 5¿ oc along the length of the bridge. They can be less than 5¿ to allow for them to be evenly spaced along the length.
Would these minor design alterations fall within that delegated design? Or should we maintain no deviation from the design we have now? Typically, not. It would be best to maintain no deviation from the plans
Attachments/Links
Contact Information
Contracting Office Address
-
2680 NATCHEZ TRACE PARKWAY
-
TUPELO , MS 38804
-
USA
Secondary Point of Contact
History
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
See also
...Follow EPOXY PUTTY,TITANIU Active Contract Opportunity Notice ID N0010426QAA37 Related Notice... contains the ...
DEPT OF DEFENSE
Bid Due: 6/17/2026
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.