CXL FOLS Replace Alarm Syst & Electrical Panel
| Location: |
Kansas |
| Posted: |
Feb 18, 2025 |
| Due: |
Feb 19, 2025 |
| Agency: |
INTERIOR, DEPARTMENT OF THE |
| Type of Government: |
Federal |
| Category: |
- Z - Maintenance, Repair or Alteration of Real Property
|
| Solicitation No: |
140P6025B0001 |
| Publication URL: |
To access bid details, please log in. |
Z--CXL FOLS Replace Alarm Syst & Electrical Panel
Active
Contract Opportunity
Department/Ind. Agency
INTERIOR, DEPARTMENT OF THE
Sub-tier
NATIONAL PARK SERVICE
Office
MWR MIDWEST REGION(60000)
Looking for contract opportunity help?
General Information View Changes
-
Contract Opportunity Type: Presolicitation (Updated)
-
Updated Published Date: Feb 18, 2025 12:22 pm CST
-
Original Published Date: Feb 12, 2025 08:50 am CST
-
Updated Response Date: Feb 19, 2025 12:00 pm CST
-
Original Response Date: Feb 19, 2025 12:00 pm CST
-
Inactive Policy: 15 days after response date
-
Updated Inactive Date: Mar 06, 2025
-
Original Inactive Date:
Mar 06, 2025
-
Initiative:
Classification
Description View Changes
Amendment to cancel this Presolicitation Notice. Presolicitation Notice was issued in error.
FOLS - Replace Alarm System and Electrical Panel
SOURCES SOUGHT (MARKET SURVEY):
The National Park Service (NPS) is conducting a market survey to determine the interest and capability of contractors for a possible upcoming project. All costs associated with providing information in response to this market survey shall be the responsibility of the firm. Any information submitted is voluntary. The Contracting Officer will make an acquisition strategy determination based on the results of this market survey.
Prime contractors interested in working at Fort Larned National Historic Site the work will consist of:
Intrusion and Fire alarm: Provide a new addressable alarm system with managing computer system in nine historic structures and the park¿s maintenance facility. The new intrusion/fire alarm system will have passive inferred intrusion sensors, and magnetic door contacts, at select locations, as part of the intrusion detection. Fire detection portion of system to include smoke and heat (rate of rise) sensors and some structures will have fire pull stations, hard wire carbon dioxide monitors and ADA compliant horn and strobe lights. All structures will have a new video
surveillance system monitoring exterior areas and points of interest on interior surfaces. Video recording equipment shall tie into the managing program of the system. This will allow off site observance of the fort and other protected resources. This system will be replacing a 2001 system manufactured by Radionics. Since this system was installed, Radionics was purchased by Bosch, which now does not support the system or components.
Electrical Panel Replacement: Replace the main 400 amperage electrical distribution panel in the park visitor center. The new panel will replace an existing panel installed in 1974 servicing the park headquarters, visitor center and museum facility. A temporary electrical service panel will be needed while work to replace the panel is installed and tested.
The NAICS code for this project is 236220, Commercial and Institutional Building Construction, with a small business size standard of $45M. The Magnitude of Construction anticipated is between $1,000,000 and $5,000,000. Interested contractors should also consider their construction bonding capacities when responding.
Contractor must be registered as a small business under the listed socio-economic categories in SAM (System for Award Management) under NAICS code 236220 to be considered/confirmed.
All specifications documents/drawings will be provided if/when the government proceeds with a formal solicitation.
Interested firms must submit the attached Market Research Sources Sought Survey.
This market research is being conducted to acquire additional information about potential contractors that may be interested in performing this work. This is not an invitation for bid (IFB) and does not constitute any commitment by the Government to issue any solicitation. All interested firms must respond to future solicitation announcements separately from responses to this market survey. Any solicitation that may be issued will be posted on SAM.gov.
All responses must be submitted via email not later than 1200 CT, February 19, 2025. Email address: bridget_parizek@nps.gov. Include the reference number (140P6025B0001) in the subject line.
Attachments/Links
Contact Information
Contracting Office Address
-
601 Riverfront Drive
-
OMAHA , NE 68102
-
USA
Secondary Point of Contact
History
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.