6515--FY26 Fluent Pro System INTENT TO SOLE SOURCE

Location: Federal
Posted: Nov 19, 2025
Due: Nov 24, 2025
Agency: VETERANS AFFAIRS, DEPARTMENT OF
Type of Government: Federal
Category:
  • 65 - Medical, Dental, and Veterinary Equipment and Supplies
Solicitation No: 36C24826Q0117
Publication URL: To access bid details, please log in.
Follow
6515--FY26 Fluent Pro System INTENT TO SOLE SOURCE
Active
Contract Opportunity
Notice ID
36C24826Q0117
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
248-NETWORK CONTRACT OFFICE 8 (36C248)
General Information
  • Contract Opportunity Type: Special Notice (Original)
  • Original Published Date: Nov 19, 2025 03:08 pm EST
  • Original Response Date: Nov 24, 2025 02:00 pm EST
  • Inactive Policy: Manual
  • Original Inactive Date: Dec 09, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
  • NAICS Code:
    • 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
  • Place of Performance:
Description
INTENT TO SOLE SOURCE
Please direct reply in the affirmative via email if you are interested and can provide the required product/service and proof of authorized servicing capabilities on the specific equipment listed for this requirement. Please provide your capability statement, I will accept responses for this Sources Sought until the 24th of November 2025 14:00 EDT, thanks.
1.Scope of Work: C.W. Bill Young Veterans Medical Center located at 10000 Bay Pines Blvd. Bay Pines; FL. 33744, is seeking procurement of one Fluent Pro System from Hologic Name Brand or Equal. This requirement needs to provide one Fluent Pro System (P/N: FLT-200).
2.Background: This unit is designed to optimize fluid control during hysteroscopic procedures. The current inventory EE#153579 has reached end of life and no longer meets the operational needs of staff.
3.Place of Performance: The product is requested to be delivered to Surgery Service, building 100, MOR. 10,000 Bay Pines Blvd, Bay Pines, Florida 33744, via the Warehouse Building 110 for Equipment.
4.Period of Performance: The product is requested to be delivered no later than December 2nd.
5.Type of Contract: Supply: Firm, Fixed Price.
6.Requirement Overview: The Contractor shall provide the full requested quantity of products listed below.
6.1 Salient Characteristics
NAME BRAND or EQUAL - Equipment Requirement: Fluent Pro System (P/N: FLT-200).
QTY. 1 - (P/N: FLT-200) Fluent Pro System

Equipment Requirement:
Minimum Required Features and Specifications
System Design and Operation
Must be an automated fluid management system with both inflow and outflow (suction) regulation for hysteroscopic procedures.
Must use SmartFlo or equivalent adaptive fluid control technology that automatically adjusts flow to maintain target intrauterine pressure.
Must include touchscreen interface for real-time visualization of pressure, inflow/outflow volumes, and fluid deficit.
Must display real-time deficit values with visual and audible alerts when approaching safety thresholds.
Must provide three selectable suction levels (Low, Medium, High) with the capability for rapid suction performance (up to 4× faster than standard Fluent system).
Must allow for automatic balancing between inflow and outflow to maintain consistent cavity distention and visualization.
Pressure and Flow Monitoring
Must measure and display intrauterine pressure in mmHg with accuracy within ±5 mmHg.
Must regulate fluid inflow to maintain the surgeon-set pressure throughout resection and evacuation phases.
Must allow user-defined safety limits for fluid deficit based on patient condition and procedure type.
Integration and Compatibility
Must be fully compatible with Hologic MyoSure® tissue-removal devices and accessories currently used at the C.W. Bill Young VAMC.
Must support connection to standard wall suction or vacuum source without modification to facility plumbing.
Must operate with single-use, disposable tubing sets and FloPak fluid cartridges to ensure sterility and eliminate cross-contamination risk.
Must not require custom hardware or external controller interfaces beyond standard operating room power and suction.
Safety and Compliance
Must provide visual and audible alarms for over-pressure, high deficit, occlusion, and flow interruptions.
Must include a built-in safety shut-off to halt inflow if deficit exceeds the pre-set threshold.
Must comply with applicable FDA, IEC, and ISO medical electrical equipment standards.
Must support use with sterile saline or electrolyte-based distension media.
Physical and Utility Requirements
Portable tabletop or cart-mounted configuration suitable for OR use.
Electrical requirements: standard 120 V AC, 60 Hz hospital outlet.
Weight: 40 lb (for easy transport and setup).
Must include holder or mount for inflow/outflow fluid bags and waste canister system.
Must include integrated display with intuitive user interface for pressure, flow rate, and deficit monitoring.
Accessories and Consumables
Must include all manufacturer-recommended accessories necessary for installation, calibration, and operation.
Must be compatible with existing facility sterilization and waste-handling protocols.
Attachments/Links
Contact Information
Contracting Office Address
  • 8875 HIDDEN RIVER PARKWAY
  • TAMPA , FL 33637
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Nov 19, 2025 03:08 pm ESTSpecial Notice (Original)

Related Document

Dec 2, 2025[Award Notice (Original)] 6515--FY26 Fluent Pro System
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...Follow Z--NIFC 410B RSC FIRE ALARM REPLACE Active Contract Opportunity Notice ID 140L3726R0006... ...

INTERIOR, DEPARTMENT OF THE

Bid Due: 8/28/2026

...Follow 6350 FIRE ALARM CONTROL SYSTEM Active Contract Opportunity Notice ID N0040626Q0192 Related...: ...

DEPT OF DEFENSE

Bid Due: 6/05/2026

..., and infrastructure for future closed-circuit television; connection to an energy monitoring control ...

DEPT OF DEFENSE

Bid Due: 6/18/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.