SEQUOIA Dual Point Davit Repair

Location: Michigan
Posted: May 27, 2025
Due: Jun 6, 2025
Agency: HOMELAND SECURITY, DEPARTMENT OF
Type of Government: Federal
Category:
  • J - Maintenance, Repair, and Rebuilding of Equipment
Solicitation No: 70Z085Q250019226
Publication URL: To access bid details, please log in.
Follow
SEQUOIA Dual Point Davit Repair
Active
Contract Opportunity
Notice ID
70Z085Q250019226
Related Notice
Department/Ind. Agency
HOMELAND SECURITY, DEPARTMENT OF
Sub-tier
US COAST GUARD
Office
SFLC PROCUREMENT BRANCH 2(00085)
General Information
  • Contract Opportunity Type: Special Notice (Original)
  • Original Published Date: May 27, 2025 01:09 pm PDT
  • Original Response Date: Jun 06, 2025 08:00 am PDT
  • Inactive Policy: Manual
  • Original Inactive Date: Jun 06, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: J020 - MAINT/REPAIR/REBUILD OF EQUIPMENT- SHIP AND MARINE EQUIPMENT
  • NAICS Code:
    • 336611 - Ship Building and Repairing
  • Place of Performance:
    Port Huron , MI 48060
    USA
Description

THIS IS TO BE AWARDED SOLE SOURCE





STATEMENT OF WORK (SOW)








  1. BACKGROUND





CGC SEQUOIA suffered a small Charlie Fire within a control panel for the Wellin Lambie Davit System. Several terminals, wires, and other components were damaged, and the DISCREP requires certified technical representatives from Wellin Lambie to conduct onsite troubleshooting, repairs, and function tests. At the request of the vendor, pictures can be sent for preliminary part requirement inquiry. Ship’s force were able to identify where the fire could have originated.






  1. REFERENCE



N/A






  1. REQUIREMENTS












        1. TO PROVIDE (1) SENIOR SERVICE FIELD TECHNICIAN WORKING (8) HRS PER DAY FOR (5) WEEKDAYS ON BOARD USCGC SEQUOIA TO ACCOMPLISH WELIN LAMBIE DAVIT TWIN PIV 5.0B SYSTEM INSPECTION, REPAIR, AND TEST.

        2. PARTS:

          1. 1000-8 DIN RAIL COMPLETE ASSEMBLED -1

            1. 859-02697 HYGROSTAT -1

            2. 859-03030 RELAY -7

            3. 859-03031 RELAY BASE -7

            4. 859-03032 RELAY RETAINING CLIP -7

            5. 859-02640 TOP HAT DIN RAIL -1

            6. 859-02400 MODULAR TERMINAL -33

            7. 859-02401 MODULAR TERMINAL -18

            8. 859-02405 END CLAMP -5

            9. 859-02410 PARTITION -12

            10. 859-02437 JUMPER BAR INSULATED -5

            11. 859-02439 JUMPER BAR INSULATED -1

            12. 859-02443 JUMPER BAR INSULATED -1

            13. 859-02685 ANGLE BRACKETS -4

            14. 859-03135 PROTECTION MODULE -7

            15. 9999 FERRULES & NUMBERING -1
















  1. 4.0 ADMINISTRATION.







4.1 CONTRACTOR PERSONELL





4.1.1 Qualified Personnel.



The Contractor shall provide qualified personnel and subject matter experts to perform all required tasks specified in this SOW.





4.1.2 Employee Conduct.



Contractor employees shall present a professional appearance, and their conduct shall not reflect discredit upon the U.S. Government, and any involved Departments or Agencies. Contractor employees shall comply with all applicable Government regulations, policies, and procedures (e.g., fire, safety, sanitation, environmental protection, security, “off limits” areas, wearing of parts of military uniforms, and possession of weapons) when visiting or working at Government facilities.





4.1.3 Conflict of Interest.



The Contractor shall not employ any person who is an employee of the U.S. Government if that employment would, or would appear to cause, a conflict of interest. The Contractor shall take appropriate precautions as delineated in the Federal Acquisition Regulation (FAR) to preclude actual or apparent conflicts of interest.





4.1.4 Facility Access



The contractor must provide a valid Real I.D.





4.2 PERIOD OF PERFORMANCE.



09JUN2025-13JUN2025





4.3 PLACE OF PERFORMANCE.





Repair facility to be determined.





5.0 USCG POC’S



CGC SEQUOIA



2700 Omar Street



Port Huron, MI 48060



POC CWO Albert (Lee) Lowery, Engineer Officer



(907) 487-5344



Email: Albert.L.Lowery@uscg.mil





Product Line Support:



ENS Marcos Saldarriaga



667-419-5729



Marcos.A.Saldarriaga@uscg.mil


Attachments/Links
Contact Information
Contracting Office Address
  • COAST GUARD ISLAND, BLDG 50-7
  • ALAMEDA , CA 94501
  • USA
Primary Point of Contact
Secondary Point of Contact
History
  • May 27, 2025 01:09 pm PDTSpecial Notice (Original)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.