Godwin Pilot Building Renovation

Location: Virginia
Posted: Jul 30, 2026
Due: Sep 11, 2026
Agency: City of Suffolk
Type of Government: State & Local
Category:
  • Z - Maintenance, Repair or Alteration of Real Property
Solicitation No: 27011-JS
Publication URL: To access bid details, please log in.
Bid Number: 27011-JS
Bid Title: Godwin Pilot Building Renovation
Category: Purchasing Bid Board Posting
Status: Open
Description:

The City seeks qualified contractor for renovation of Godwin - Virginian Pilot Building

Publication Date/Time:
7/8/2026 12:00 AM
Closing Date/Time:
9/11/2026 3:00 PM
Pre-bid Meeting:
MANDATORY - July 23, 2026
Contact Person:
Jay Smigielski
jsmigielski@suffolkva.us
757-514-7523
Special Requirements:
Mandatory Pre-bid meeting July 23, 2026
10:00 am
157 N. Main St. Suffolk
Godwin Virginian Pilot Building
Related Documents:

Attachment Preview

RIGID FIBER GLASS PIPE INSULATION SCHEDULE
PIPING SYSTEM SYSTEM TEMPERATURE PIPING INSULATION THICKNESS
RANGE ( degreesF) LESS 1" 1" TO LESS 1- 1/2" 1 -1/2" & MORE
DOMESTIC HW & HWR 110 - 140 1" 1" 1-1/2"
DOMESTIC CW 48 -80 1/2" 1/2" 1"
HORIZONTAL RL & ORL 35 - 80 1/2" 1/2" 1/2"
ALL PLUMBING VENTS WITHIN A 10' - 0" RADIUS OF ANY ROOF TOP UNIT SHALL BE EXTENDED
TO A HEIGHT OF 3' - 0" ABOVE THE FRESH AIR INTAKE.
110 - 14
- 1/2"
AMERICANS WITH
DISABILITIES ACT COMPLIANT
NATIONAL FIRE
PROTECTION ASSOCIATION
ALL WALL HYDRANTS SHALL BE MOUNTED 24" ABOVE FINISHED GRADE UNLESS OTHERWISE
SPECIFIED
48 - 80
P -#
FIXTURE HW DISCHARGE TEMPERATURES
PLUMBING FIXTURE MAXIMUM DISCHARGE TEMPERATURE REFERENCE STANDARD
PUBLIC HAND-WASHING FACILITIES >85 degreesF & <110 degreesF ASSE 1070
INDIVIDUAL SHOWER VALVES 120 degreesF ASSE 1016 OR CSA B125
ALL HOT & COLD WATER PIPING INDICATED TO RUN ABOVE FINISHED CEILINGS OR IN
EXTERIOR WALLS SHALL BE INSTALLED ON THE CONDITIONED SPACE SIDE OF THE BUILDING
INSULATION.
PUBLIC HAND - WASHING FACILITIES
IT IS THE INTENTION OF THESE DRAWINGS TO COVER ALL WORK & MATERIAL FOR A
COMPLETE FIRST CLASS INSTALLATION. ANY EQUIPMENT, PLUMBING FIXTURE, TRIM
HARDWARE &/OR DEVICES USUALLY UTILIZED IN THE CLASS OF WORK, THOUGH NOT
SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT WHICH MAY BE NECESSARY
FOR THE SATISFACTORY COMPLETION OF THE WORK (AS DETERMINED BY THE ARCHITECT)
SHALL BE FURNISHED & INSTALLED BY THE CONTRACTOR AS PART OF HIS TOTAL WORK.
DETAIL/RISER/ENLARGED PLAN
SHEET WHERE SHOWN/CUT
THIS BUILDING IS CURRENTLY PROTECTED BY A FULLY AUTOMATIC WET PIPE
SPRINKLER SYSTEM. THIS CONTRACTOR SHALL MODIFY THE EXISTING
SPRINKLER SYSTEM INSTALLATION AS REQUIRED TO SUIT NEW FLOOR PLANS
AND REFLECTED CEILING PLANS WITHIN THE LIMITS OF CONSTRUCTION.
SPRINKLER SYSTEM DESIGN, MATERIALS AND INSTALLATION SHALL BE IN
ACCORDANCE WITH NFPA 13, STATE, AND LOCAL AUTHORITIES. SPACING AND
THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY FAMILIARIZE
HIMSELF/HERSELF WITH THE EXISTING CONDITIONS. NOT ALL EQUIPMENT AND
APPURTENANCES ARE SHOWN. FAILURE TO FOLLOW THIS STEP SHALL NOT BE A BASIS FOR
CHANGE ORDERS.
VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK OR ORDERING EQUIPMENT,
PIPING, FIXTURES, ETC.
SEAL AROUND ALL WALL PENETRATIONS AIR TIGHT AT MECHANICAL ROOM, & FILL ANY VOIDS
WITH MORTAR.
MANUFACTURER'S RECOMMENDATIONS: ALL MATERIAL AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATION FOR THE INTENDED PURPOSE. USE THE MORE STRINGENT METHODS WHEN MANUFACTURER'S RECOMMENDATIONS, PLANS & SPECIFICATION REQUIREMENTS DIFFER. BRING ANY CONFLICTS BETWEEN MANUFACTURER'S RECOMMENDATIONS, PLANS & SPECIFICATION REQUIREMENTS TO THE OWNER'S ATTENTION.
MANUFACTURER'S RECOMMENDATIONS: ALL MATERIAL AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATION FOR THE INTENDED PURPOSE. USE THE MORE STRINGENT METHODS WHEN MANUFACTURER'S RECOMMENDATIONS, PLANS & SPECIFICATION REQUIREMENTS DIFFER. BRING ANY CONFLICTS BETWEEN MANUFACTURER'S RECOMMENDATIONS, PLANS & SPECIFICATION REQUIREMENTS TO THE OWNER'S ATTENTION. MANUFACTURER'S RECOMMENDATIONS: ALL MATERIAL AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATION FOR THE INTENDED PURPOSE. USE THE MORE STRINGENT METHODS WHEN MANUFACTURER'S RECOMMENDATIONS, PLANS & SPECIFICATION REQUIREMENTS DIFFER. BRING ANY CONFLICTS BETWEEN MANUFACTURER'S RECOMMENDATIONS, PLANS & SPECIFICATION REQUIREMENTS TO THE OWNER'S ATTENTION.
PHYSICAL OR ELECTRICAL CHARACTERISTICS, ETC. WHEN COMPARED TO THE BASIS OF
DESIGN EQUIPMENT, THIS CONTRACTOR IS RESPONSIBLE FOR COORDINATING THESE
CHANGES WITH THE OTHER TRADES PRIOR TO ORDERING OF EQUIPMENT. IF THERE SHOULD
BE ANY ADDITIONAL WORK INCURRED BY THE OTHER TRADES AS A RESULT OF THIS
CONTRACTOR'S EQUIPMENT SELECTION, ALL COSTS ASSOCIATED WITH THE ADDITIONAL
WORK SHALL BE BORNE BY THIS CONTRACTOR.
THE MANUFACTURER'S RECOMMENDATION FOR THE INTENDED PURPOSE. US
THE MORE STRINGENT METHODS WHEN MANUFACTURER'S
RECOMMENDATIONS, PLANS & SPECIFICATION REQUIREMENTS DIFFER. BRING
ANY CONFLICTS BETWEEN MANUFACTURER'S RECOMMENDATIONS, PLANS &
SPECIFICATION REQUIREMENTS TO THE OWNER'S ATTENTION.
FIRE STOPPING NOTE: CONTRACTOR SHALL PROVIDE AN APPROPRIATE LISTED THROUGH- PENETRATION FIRE STOPPING ASSEMBLY AT EACH PENETRATION OF FIRE RATED CONSTRUCTION (I.E. WALLS AND SLABS, ETC.). FIRE STOPPING OF DUCT PENETRATIONS THROUGH RATED ASSEMBLIES ARE ONLY PERMITTED WHEN FIRE AND/ OR SMOKE DAMPERS ARE NOT REQUIRED. SLEEVES SHALL ONLY BE PERMITTED WHERE INDICATED IN THE CONTRACTOR SELECTED THROUGH- PENETRATION FIRE STOPPING ASSEMBLY. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF ALL RATED ASSEMBLIES AND ASSOCIATED UL DESIGNATIONS. DEVICES INSTALLED RECESSED WITHIN FIRE RATED CONSTRUCTION (I.E. LIGHT SWITCHES, RECEPTACLES, ICE MAKER BOXES, ETC.) ARE ONLY PERMITTED WHEN AN APPROVED LISTED FIRE STOPPING SYSTEM EXISTS FOR THE APPLICATION. IF AN APPROVED LISTED FIRE STOPPING SYSTEM IS NOT AVAILABLE, THE CONTRACTOR SHALL BRING THE CONDITION TO THE ATTENTION OF THE A/E FOR RESOLUTION PRIOR TO PROCEEDING WITH WORK.
FIRE STOPPING NOTE: CONTRACTOR SHALL PROVIDE AN APPROPRIATE LISTED THROUGH- PENETRATION FIRE STOPPING ASSEMBLY AT EACH PENETRATION OF FIRE RATED CONSTRUCTION (I.E. WALLS AND SLABS, ETC.). FIRE STOPPING OF DUCT PENETRATIONS THROUGH RATED ASSEMBLIES ARE ONLY PERMITTED WHEN FIRE AND/ OR SMOKE DAMPERS ARE NOT REQUIRED. SLEEVES SHALL ONLY BE PERMITTED WHERE INDICATED IN THE CONTRACTOR SELECTED THROUGH- PENETRATION FIRE STOPPING ASSEMBLY. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF ALL RATED ASSEMBLIES AND ASSOCIATED UL DESIGNATIONS. DEVICES INSTALLED RECESSED WITHIN FIRE RATED CONSTRUCTION (I.E. LIGHT SWITCHES, RECEPTACLES, ICE MAKER BOXES, ETC.) ARE ONLY PERMITTED WHEN AN APPROVED LISTED FIRE STOPPING SYSTEM EXISTS FOR THE APPLICATION. IF AN APPROVED LISTED FIRE STOPPING SYSTEM IS NOT AVAILABLE, THE CONTRACTOR SHALL BRING THE CONDITION TO THE ATTENTION OF THE A/E FOR RESOLUTION PRIOR TO PROCEEDING WITH WORK. FIRE STOPPING NOTE: CONTRACTOR SHALL PROVIDE AN APPROPRIATE LISTED THROUGH- PENETRATION FIRE STOPPING ASSEMBLY AT EACH PENETRATION OF FIRE RATED CONSTRUCTION (I.E. WALLS AND SLABS, ETC.). FIRE STOPPING OF DUCT PENETRATIONS THROUGH RATED ASSEMBLIES ARE ONLY PERMITTED WHEN FIRE AND/ OR SMOKE DAMPERS ARE NOT REQUIRED. SLEEVES SHALL ONLY BE PERMITTED WHERE INDICATED IN THE CONTRACTOR SELECTED THROUGH- PENETRATION FIRE STOPPING ASSEMBLY. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF ALL RATED ASSEMBLIES AND ASSOCIATED UL DESIGNATIONS. DEVICES INSTALLED RECESSED WITHIN FIRE RATED CONSTRUCTION (I.E. LIGHT SWITCHES, RECEPTACLES, ICE MAKER BOXES, ETC.) ARE ONLY PERMITTED WHEN AN APPROVED LISTED FIRE STOPPING SYSTEM EXISTS FOR THE APPLICATION. IF AN APPROVED LISTED FIRE STOPPING SYSTEM IS NOT AVAILABLE, THE CONTRACTOR SHALL BRING THE CONDITION TO THE ATTENTION OF THE A/E FOR RESOLUTION PRIOR TO PROCEEDING WITH WORK.
PLUMBING COORDINATION NOTE: CONTRACTOR SHALL COORDINATE CLOSELY WITH ALL TRADES TO ENSURE PLUMBING IS INSTALLED WITHOUT CONFLICTING WITH OTHER BUILDING SYSTEMS. CONTRACTOR SHALL VERIFY AND COORDINATE THE EXACT LOCATION OF ALL MECHANICAL, ELECTRICAL, PLUMBING, AND STRUCTURAL SYSTEMS AND COMPONENTS (EXISTING AND NEW) PRIOR TO COMMENCING WORK. REFER TO ARCHITECTURAL DRAWINGS FOR CONSTRUCTION DETAILS. CONTRACTOR SHALL VERIFY ALL POINTS OF CONNECTION TO EXISTING SYSTEMS, PRIOR TO BEGINNING ANY WORK. THE FAILURE TO COMPLY WITH THESE DIRECTIONS SHALL NOT CONSTITUTE THE BASIS FOR A CHANGE ORDER SHOULD REWORK BE REQUIRED. ANY CONDITIONS FOUND THAT WILL PROHIBIT MAKING THE FINAL CONNECTIONS(S) OR EXECUTIONS OF THE WORK SHALL BE REPORTED TO THE A/E IMMEDIATELY. CONTRACTOR TO FIELD COORDINATE ALL PIPING LOCATIONS. WHERE THE EXACT LOCATIONS OF SANITARY PIPING NOT KNOWN, CONTRACTOR TO FIELD TRACE EXACT ROUTING PRIOR TO ANY SAW CUTTING. ANY SHUT DOWNS OR INTERRUPTIONS IN SERVICE SHALL BE APPROVED BY THE OWNER AT LEAST 7 DAYS BEFORE THE WORK IS TO BE EXECUTED. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR ANY DELAYS TO THE PROJECT THAT ARISE DUE TO HIS FAILURE TO COMPLY WITH THESE REQUIREMENTS.
PLUMBING COORDINATION NOTE: CONTRACTOR SHALL COORDINATE CLOSELY WITH ALL TRADES TO ENSURE PLUMBING IS INSTALLED WITHOUT CONFLICTING WITH OTHER BUILDING SYSTEMS. CONTRACTOR SHALL VERIFY AND COORDINATE THE EXACT LOCATION OF ALL MECHANICAL, ELECTRICAL, PLUMBING, AND STRUCTURAL SYSTEMS AND COMPONENTS (EXISTING AND NEW) PRIOR TO COMMENCING WORK. REFER TO ARCHITECTURAL DRAWINGS FOR CONSTRUCTION DETAILS. CONTRACTOR SHALL VERIFY ALL POINTS OF CONNECTION TO EXISTING SYSTEMS, PRIOR TO BEGINNING ANY WORK. THE FAILURE TO COMPLY WITH THESE DIRECTIONS SHALL NOT CONSTITUTE THE BASIS FOR A CHANGE ORDER SHOULD REWORK BE REQUIRED. ANY CONDITIONS FOUND THAT WILL PROHIBIT MAKING THE FINAL CONNECTIONS(S) OR EXECUTIONS OF THE WORK SHALL BE REPORTED TO THE A/E IMMEDIATELY. CONTRACTOR TO FIELD COORDINATE ALL PIPING LOCATIONS. WHERE THE EXACT LOCATIONS OF SANITARY PIPING NOT KNOWN, CONTRACTOR TO FIELD TRACE EXACT ROUTING PRIOR TO ANY SAW CUTTING. ANY SHUT DOWNS OR INTERRUPTIONS IN SERVICE SHALL BE APPROVED BY THE OWNER AT LEAST 7 DAYS BEFORE THE WORK IS TO BE EXECUTED. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR ANY DELAYS TO THE PROJECT THAT ARISE DUE TO HIS FAILURE TO COMPLY WITH THESE REQUIREMENTS. PLUMBING COORDINATION NOTE: CONTRACTOR SHALL COORDINATE CLOSELY WITH ALL TRADES TO ENSURE PLUMBING IS INSTALLED WITHOUT CONFLICTING WITH OTHER BUILDING SYSTEMS. CONTRACTOR SHALL VERIFY AND COORDINATE THE EXACT LOCATION OF ALL MECHANICAL, ELECTRICAL, PLUMBING, AND STRUCTURAL SYSTEMS AND COMPONENTS (EXISTING AND NEW) PRIOR TO COMMENCING WORK. REFER TO ARCHITECTURAL DRAWINGS FOR CONSTRUCTION DETAILS. CONTRACTOR SHALL VERIFY ALL POINTS OF CONNECTION TO EXISTING SYSTEMS, PRIOR TO BEGINNING ANY WORK. THE FAILURE TO COMPLY WITH THESE DIRECTIONS SHALL NOT CONSTITUTE THE BASIS FOR A CHANGE ORDER SHOULD REWORK BE REQUIRED. ANY CONDITIONS FOUND THAT WILL PROHIBIT MAKING THE FINAL CONNECTIONS(S) OR EXECUTIONS OF THE WORK SHALL BE REPORTED TO THE A/E IMMEDIATELY. CONTRACTOR TO FIELD COORDINATE ALL PIPING LOCATIONS. WHERE THE EXACT LOCATIONS OF SANITARY PIPING NOT KNOWN, CONTRACTOR TO FIELD TRACE EXACT ROUTING PRIOR TO ANY SAW CUTTING. ANY SHUT DOWNS OR INTERRUPTIONS IN SERVICE SHALL BE APPROVED BY THE OWNER AT LEAST 7 DAYS BEFORE THE WORK IS TO BE EXECUTED. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR ANY DELAYS TO THE PROJECT THAT ARISE DUE TO HIS FAILURE TO COMPLY WITH THESE REQUIREMENTS.
SAW CUT NOTE: CONTRACTOR SHALL VERIFY PIPE INVERTS PRIOR TO SAW CUTTING. CONTRACTOR SHALL SAW CUT, REMOVE AND PATCH CONCRETE FLOOR AS REQUIRED TO PERFORM WORK INDICATED. PATCH FLOOR TO MATCH ADJACENT EXISTING CONDITIONS AND NEW CONDITIONS.
SAW CUT NOTE: CONTRACTOR SHALL VERIFY PIPE INVERTS PRIOR TO SAW CUTTING. CONTRACTOR SHALL SAW CUT, REMOVE AND PATCH CONCRETE FLOOR AS REQUIRED TO PERFORM WORK INDICATED. PATCH FLOOR TO MATCH ADJACENT EXISTING CONDITIONS AND NEW CONDITIONS. SAW CUT NOTE: CONTRACTOR SHALL VERIFY PIPE INVERTS PRIOR TO SAW CUTTING. CONTRACTOR SHALL SAW CUT, REMOVE AND PATCH CONCRETE FLOOR AS REQUIRED TO PERFORM WORK INDICATED. PATCH FLOOR TO MATCH ADJACENT EXISTING CONDITIONS AND NEW CONDITIONS.
CONTRACTOR SHALL PROVIDE AN APPROPRIATE LISTED THROUGH -
PENETRATION FIRE STOPPING ASSEMBLY AT EACH PENETRATION OF FIRE
RATED CONSTRUCTION (I.E. WALLS AND SLABS, ETC.). FIRE STOPPING OF DUCT
PENETRATIONS THROUGH RATED ASSEMBLIES ARE ONLY PERMITTED WHEN
FIRE AND/ OR SMOKE DAMPERS ARE NOT REQUIRED. SLEEVES SHALL ONLY BE
PERMITTED WHERE INDICATED IN THE CONTRACTOR SELECTED THROUGH
PENETRATION FIRE STOPPING ASSEMBLY. REFER TO ARCHITECTURAL
DRAWINGS FOR LOCATION OF ALL RATED ASSEMBLIES AND ASSOCIATED UL
DESIGNATIONS. DEVICES INSTALLED RECESSED WITHIN FIRE RATED
CONSTRUCTION (I.E. LIGHT SWITCHES, RECEPTACLES, ICE MAKER BOXES, ETC.)
ARE ONLY PERMITTED WHEN AN APPROVED LISTED FIRE STOPPING SYSTEM
EXISTS FOR THE APPLICATION. IF AN APPROVED LISTED FIRE STOPPING
SYSTEM IS NOT AVAILABLE, THE CONTRACTOR SHALL BRING THE CONDITION TO
THE ATTENTION OF THE A/E FOR RESOLUTION PRIOR TO PROCEEDING WITH
WORK.
REQUIRED TO PERFORM WORK INDICATED. PATCH FLOOR TO MATCH ADJACENT
EXISTING CONDITIONS AND NEW CONDITIONS.
CONTRACTOR SHALL VERIFY AND COORDINATE THE EXACT LOCATION OF ALL
MECHANICAL, ELECTRICAL, PLUMBING, AND STRUCTURAL SYSTEMS AND
COMPONENTS (EXISTING AND NEW) PRIOR TO COMMENCING WORK.
REFER TO ARCHITECTURAL DRAWINGS FOR CONSTRUCTION DETAILS.
WALL WORK NOTE: PLUMBING CONTRACTOR SHALL REMOVE PORTIONS OF EXISTING WALLS AS REQUIRED FOR ACCESS TO EXISTING PLUMBING PIPING FOR REMODELING WORK. CONTRACTOR SHALL PATCH TO MATCH EXISTING ADJACENT CONDITIONS AND RATINGS. REFER TO ARCHITECTURAL PLAN FOR PATCHING DETAILS AND NOTES.
WALL WORK NOTE: PLUMBING CONTRACTOR SHALL REMOVE PORTIONS OF EXISTING WALLS AS REQUIRED FOR ACCESS TO EXISTING PLUMBING PIPING FOR REMODELING WORK. CONTRACTOR SHALL PATCH TO MATCH EXISTING ADJACENT CONDITIONS AND RATINGS. REFER TO ARCHITECTURAL PLAN FOR PATCHING DETAILS AND NOTES. WALL WORK NOTE: PLUMBING CONTRACTOR SHALL REMOVE PORTIONS OF EXISTING WALLS AS REQUIRED FOR ACCESS TO EXISTING PLUMBING PIPING FOR REMODELING WORK. CONTRACTOR SHALL PATCH TO MATCH EXISTING ADJACENT CONDITIONS AND RATINGS. REFER TO ARCHITECTURAL PLAN FOR PATCHING DETAILS AND NOTES.
THESE DIRECTIONS SHALL NOT CONSTITUTE THE BASIS FOR A CHANGE ORDER
SHOULD REWORK BE REQUIRED.
REQUIRED FOR ACCESS TO EXISTING PLUMBING PIPING FOR REMODELING
WORK. CONTRACTOR SHALL PATCH TO MATCH EXISTING ADJACENT
CONDITIONS AND RATINGS. REFER TO ARCHITECTURAL PLAN FOR PATCHING
DETAILS AND NOTES.
ANY CONDITIONS FOUND THAT WILL PROHIBIT MAKING THE FINAL
CONNECTIONS(S) OR EXECUTIONS OF THE WORK SHALL BE REPORTED TO THE
A/E IMMEDIATELY.
SANITARY SEWER LINE SCOPE NOTE: AS INDICATED IN THESE CONTRACT DOCUMENTS, CONTRACTOR SHALL SCOPE AND SCAN ALL SEWER LINES WITHIN THE PROJECT LIMITS TO DETERMINE AND DOCUMENT APPROXIMATE LOCATION, ROUTING, DEBRIS MATTER AND CLOGS PRIOR TO COMMENCEMENT OF WORK. PROVIDE DRAWINGS AND DVD TO OWNER AND ENGINEER FOR REVIEW.
SANITARY SEWER LINE SCOPE NOTE: AS INDICATED IN THESE CONTRACT DOCUMENTS, CONTRACTOR SHALL SCOPE AND SCAN ALL SEWER LINES WITHIN THE PROJECT LIMITS TO DETERMINE AND DOCUMENT APPROXIMATE LOCATION, ROUTING, DEBRIS MATTER AND CLOGS PRIOR TO COMMENCEMENT OF WORK. PROVIDE DRAWINGS AND DVD TO OWNER AND ENGINEER FOR REVIEW. SANITARY SEWER LINE SCOPE NOTE: AS INDICATED IN THESE CONTRACT DOCUMENTS, CONTRACTOR SHALL SCOPE AND SCAN ALL SEWER LINES WITHIN THE PROJECT LIMITS TO DETERMINE AND DOCUMENT APPROXIMATE LOCATION, ROUTING, DEBRIS MATTER AND CLOGS PRIOR TO COMMENCEMENT OF WORK. PROVIDE DRAWINGS AND DVD TO OWNER AND ENGINEER FOR REVIEW.
CONTRACTOR TO FIELD COORDINATE ALL PIPING LOCATIONS. WHERE TH
EXACT LOCATIONS OF SANITARY PIPING NOT KNOWN, CONTRACTOR TO FIELD
OCCUPANCY NOTE: BUILDING SHALL REMAIN OCCUPIED IN OTHER AREAS OF THE BUILDING. CONTRACTOR SHALL TAKE CARE TO NOT INTERRUPT POWER, WATER, HVAC, ETC. IF SHUT DOWNS OR SHUT OFFS ARE REQUIRED CONTRACTOR SHALL NOTIFY FACILITIES IN WRITING WITH TIME AND SCHEDULE A MINIMUM OF 72 HOURS PRIOR TO COMMENCING WORK.
OCCUPANCY NOTE: BUILDING SHALL REMAIN OCCUPIED IN OTHER AREAS OF THE BUILDING. CONTRACTOR SHALL TAKE CARE TO NOT INTERRUPT POWER, WATER, HVAC, ETC. IF SHUT DOWNS OR SHUT OFFS ARE REQUIRED CONTRACTOR SHALL NOTIFY FACILITIES IN WRITING WITH TIME AND SCHEDULE A MINIMUM OF 72 HOURS PRIOR TO COMMENCING WORK. OCCUPANCY NOTE: BUILDING SHALL REMAIN OCCUPIED IN OTHER AREAS OF THE BUILDING. CONTRACTOR SHALL TAKE CARE TO NOT INTERRUPT POWER, WATER, HVAC, ETC. IF SHUT DOWNS OR SHUT OFFS ARE REQUIRED CONTRACTOR SHALL NOTIFY FACILITIES IN WRITING WITH TIME AND SCHEDULE A MINIMUM OF 72 HOURS PRIOR TO COMMENCING WORK.
AS INDICATED IN THESE CONTRACT DOCUMENTS, CONTRACTOR SHALL SCOP
AND SCAN ALL SEWER LINES WITHIN THE PROJECT LIMITS TO DETERMINE AN
DOCUMENT APPROXIMATE LOCATION, ROUTING, DEBRIS MATTER AND CLOGS
BUILDING SHALL REMAIN OCCUPIED IN OTHER AREAS OF THE BUILDING.
CONTRACTOR SHALL TAKE CARE TO NOT INTERRUPT POWER, WATER, HVAC,
ETC. IF SHUT DOWNS OR SHUT OFFS ARE REQUIRED CONTRACTOR SHALL
NOTIFY FACILITIES IN WRITING WITH TIME AND SCHEDULE A MINIMUM OF 72
HOURS PRIOR TO COMMENCING WORK.
CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR ANY DELAYS TO THE
PROJECT THAT ARISE DUE TO HIS FAILURE TO COMPLY WITH THESE
REQUIREMENTS.

1 2 3 4 5 6
GENERAL NOTES LEGEND & ABBREVIATIONS
RIGID FIBER GLASS PIPE INSULATION SCHEDULE
ALL PLUMBING VENTS WITHIN A 10'-0" RADIUS OF ANY ROOF TOP UNIT SHALL BE EXTENDED EXISTING PIPING TO REMAIN A/E ARCHITECT/ENGINEER MAX MAXIMUM
PIPING INSULATION THICKNESS
SYSTEM TEMPERATURE
PIPING SYSTEM TO A HEIGHT OF 3'-0" ABOVE THE FRESH AIR INTAKE.
ARCHITECTURE ENGINEERING GEOSPATIAL
RANGE ( degreesF) LESS 1" 1" TO LESS 1-1/2" 1-1/2" & MORE EXISTING PIPING TO BE REMOVED AC ABOVE CEILING MIN MINIMUM
4433 CORPORATION LANE
ALL PLUMBING & PLUMBING MATERIALS SHALL MEET THE REQUIREMENTS OF THE STATE & SUITE 125
DOMESTIC HW & HWR 110 - 140 1" 1" 1-1/2" LOCAL PLUMBING CODES. FIRE PROTECTION PIPING ADA AMERICANS WITH NFPA NATIONAL FIRE VIRGINIA BEACH, VA 23462
800.414.1045
DISABILITIES ACT COMPLIANT PROTECTION ASSOCIATION
DOMESTIC COLD WATER (CW)
ALL WALL HYDRANTS SHALL BE MOUNTED 24" ABOVE FINISHED GRADE UNLESS OTHERWISE
DOMESTIC CW 48 -80 1/2" 1/2" 1" SPECIFIED. ASSE AMERICAN SOCIETY OF P-# PLUMBING FIXTURE MARK E
DOMESTIC HOT WATER (HW)
SANITARY ENGINEERING
SLOPES & INVERT ELEVATIONS OF ALL INTERIOR PIPING SHALL BE ESTABLISHED BEFORE SFU SUPPLY FIXTURE UNIT
HORIZONTAL RL & ORL 35 - 80 1/2" 1/2" 1/2" ANY PIPING IS INSTALLED, IN ORDER THAT PROPER SLOPES WILL BE MAINTAINED. ALL PIPING DOMESTIC HOT WATER RETURN (HWR) COMP COMPARTMENT W E ALTHOF V I
TG AUTOMATIC TRAP GUARD N R
SHALL BE RUN TO AVOID CONFLICTS WITH OTHER TRADES. O G
SANITARY WASTE PIPE (WP) M I
ROOF DRAIN SUMPS CT COUNTER TOP M N
(INCLUDING OVERFLOW) 35 - 80 1/2" 1/2" 1/2" COORDINATE WITH ARCHITECTURAL WORKING DRAWINGS BEFORE ROUGHING-IN PLUMBING SANITARY VENT PIPE (VP) TYP TYPICAL C O I A
FIXTURES. DFU DRAINAGE FIXTURE UNIT
W/ WITH
N T
JA
O O
C
T 6
K
E '-
E
0 :
T
" P A R
S
B O
H
O V
A
V I
L
D E
L
E
B
F C
E
IN O
W
IS R
H
H R
I
E U
T
D G
E
A F
K
T L
R
O E
A
D O
F
R
T
O S R
B O
& S
N
M M
D
O E
E
Z O
D
Z T A
T
H N
O
A I N
0
L E
.
U
0
S M
2 5
I F N
m
O U
m
R M
(
I
1
N J A S
M
C U
IL
K L
)
A E
T
T T
H
I O F
IC
O N
K
R P
A
A R
L
L O
U
L T
M
I E N
IN
C S
U
T U I
M
O LA N
F
T
O
. E A
IL
D L
,
L P S IP E E R S V 0 IC '- E 0" M
PI
A
P
K
IN
E
G
P
C
R
O
O
N
P
N
E
E
R
C
H
T
O
IO
T
N
&
S
C
T
O
O
L
A
D
L
W
L
A
F
T
IX
E
T
R
U
,
R
H
E
O
S
T
&
W
E
A
Q
T
U
E
I
R
P M
R
E
E
N
C
T
IR
E
C
V
U
E
L
N
A T
T
I
H
N
O
G
U
, W
GH
A S
A
T
L
E
L
,
B
&
R
V
A
E
N
N
C
T
H
,
E
E
S
T
,
C ., P
P
I
IP
P
E
E
T
T
U
UR
R
N
N
U
D
P
OWN (DN)
ELEC ELECTRIC WC WATER COLUMN/WATER CLOSET P R O F E S
S IONALEN
GI N E E R
ELEV ELEVATION
FIBERGLASS REINFORCED, WITH PRESSURE SENSITIVE ADHESIVE CLOSURE. COMPLY WITH ASTM FITTINGS & CONNECTIONS ARE NOT SHOWN. WH-# WATER HEATER MARK
C1136. PROVIDE PREFORMED MOISTURE BARRIER JACKETS OVER FITTINGS AND VALVES. PIPE CAPPED
ETR EXISTING TO REMAIN
COORDINATE LOCATION OF ALL EQUIPMENT, FIXTURES & PIPING WITH STRUCTURAL & ALL WM WALL MOUNTED
OTHER TRADES. PIPING RUN AC SHALL BE RUN AS HIGH AS POSSIBLE. CLEAN OUT (CO)
EXIST EXISTING
WS WASTE STACK
FIXTURE HW DISCHARGE TEMPERATURES
ALL OPENINGS IN CEILINGS & PLENUM WALLS FOR PLUMBING PIPES SHALL BE SEALED AIR WALL CLEAN OUT (WCO)
FDC FIRE DEPARTMENT CONNECTION
TIGHT.
BALL VALVE (BV)
FT FLUSH TANK/FEET
MAXIMUM DISCHARGE
PLUMBING FIXTURE REFERENCE STANDARD
ALL HOT & COLD WATER PIPING INDICATED TO RUN ABOVE FINISHED CEILINGS OR IN
TEMPERATURE FLOOR CLEAN OUT (FCO)
EXTERIOR WALLS SHALL BE INSTALLED ON THE CONDITIONED SPACE SIDE OF THE BUILDING GAL GALLON
GROUND CLEAN OUT (GCO)
INSULATION.
PUBLIC HAND-WASHING FACILITIES >85 degreesF & <110 degreesF ASSE 1070 FLOOR DRAIN (FD) GPH GALLONS PER HOUR
SLOPES & INVERT ELEVATIONS OF EXTERIOR SEWERS, MANHOLES, ETC., SHALL BE
D
ESTABLISHED & VERIFIED BY PLUMBING CONTRACTOR BEFORE ANY PIPING IS INSTALLED IN LIMIT OF DEMOLITION WORK GPM GALLONS PER MINUTE
INDIVIDUAL SHOWER VALVES 120 degreesF ASSE 1016 OR CSA B125
ORDER THAT PROPER SLOPES WILL BE MAINTAINED & NECESSARY INVERT ELEVATIONS
HP HORSE POWER
NEW POINT OF CONNECTION
OBTAINED.
NOTE: PROVIDE LISTED TEMPERING DEVICE FOR EACH FIXTURE PER TABLE.
HWRP HOT WATER RECIRCULATING PUMP
DEMOLITION NOTE DESIGNATION
PROVIDE AUTOMATIC TRAP GUARDS FOR ALL FLOOR DRAINS.
INV INVERT
NEW WORK NOTE DESIGNATION
SPRINKLER NOTE: IT IS THE INTENTION OF THESE DRAWINGS TO COVER ALL WORK & MATERIAL FOR A
COMPLETE FIRST CLASS INSTALLATION. ANY EQUIPMENT, PLUMBING FIXTURE, TRIM KW KILOWATTS
HARDWARE &/OR DEVICES USUALLY UTILIZED IN THE CLASS OF WORK, THOUGH NOT DETAIL/RISER/ENLARGED PLAN
THIS BUILDING IS CURRENTLY PROTECTED BY A FULLY AUTOMATIC WET PIPE
SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT WHICH MAY BE NECESSARY SHEET WHERE SHOWN/CUT LAV LAVATORY
SPRINKLER SYSTEM. THIS CONTRACTOR SHALL MODIFY THE EXISTING
FOR THE SATISFACTORY COMPLETION OF THE WORK (AS DETERMINED BY THE ARCHITECT)
SPRINKLER SYSTEM INSTALLATION AS REQUIRED TO SUIT NEW FLOOR PLANS
SHALL BE FURNISHED & INSTALLED BY THE CONTRACTOR AS PART OF HIS TOTAL WORK.
AND REFLECTED CEILING PLANS WITHIN THE LIMITS OF CONSTRUCTION.
SPRINKLER SYSTEM DESIGN, MATERIALS AND INSTALLATION SHALL BE IN
THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY FAMILIARIZE
ACCORDANCE WITH NFPA 13, STATE, AND LOCAL AUTHORITIES. SPACING AND
HIMSELF/HERSELF WITH THE EXISTING CONDITIONS. NOT ALL EQUIPMENT AND
LOCATION OF SPRINKLERS SHALL NOT EXCEED THAT PERMITTED FOR LIGHT
APPURTENANCES ARE SHOWN. FAILURE TO FOLLOW THIS STEP SHALL NOT BE A BASIS FOR
HAZARD OCCUPANCY. IN ACCORDANCE WITH NFPA 25, CONTRACTOR SHALL
CHANGE ORDERS.
TEMPORARILY TURN SPRINKLER HEADS UP DURING CONSTRUCTION AND AS
REQUIRED TO ACHIEVE A FULLY FUNCTIONAL SPRINKLER SYSTEM. ANY FIRE
VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK OR ORDERING EQUIPMENT,
WATCH REQUIRED WILL BE PERFORMED BY THE CONTRACTOR.
PIPING, FIXTURES, ETC.
SEAL AROUND ALL WALL PENETRATIONS AIR TIGHT AT MECHANICAL ROOM, & FILL ANY VOIDS
SPRINKLER SCHEDULE:
WITH MORTAR.
USE SPRINKLER TYPES BELOW FOR THE FOLLOWING APPLICATIONS: C
INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS &
ROOMS WITHOUT CEILINGS: UPRIGHT SPRINKLERS
ALL APPLICABLE LISTING REQUIREMENTS.
ROOMS WITH SUSPENDED CEILINGS: CONCEALED SPRINKLERS.
INTERDISCIPLINARY COORDINATION
IF THIS CONTRACTOR SHOULD ELECT TO PROPOSE ANY EQUIPMENT THAT HAS DIFFERENT
PHYSICAL OR ELECTRICAL CHARACTERISTICS, ETC. WHEN COMPARED TO THE BASIS OF
DESIGN EQUIPMENT, THIS CONTRACTOR IS RESPONSIBLE FOR COORDINATING THESE
MANUFACTURER'S RECOMMENDATIONS:
CHANGES WITH THE OTHER TRADES PRIOR TO ORDERING OF EQUIPMENT. IF THERE SHOULD
BE ANY ADDITIONAL WORK INCURRED BY THE OTHER TRADES AS A RESULT OF THIS
ALL MATERIAL AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH CONTRACTOR'S EQUIPMENT SELECTION, ALL COSTS ASSOCIATED WITH THE ADDITIONAL
THE MANUFACTURER'S RECOMMENDATION FOR THE INTENDED PURPOSE. USE WORK SHALL BE BORNE BY THIS CONTRACTOR.
THE MORE STRINGENT METHODS WHEN MANUFACTURER'S
RECOMMENDATIONS, PLANS & SPECIFICATION REQUIREMENTS DIFFER. BRING
ANY CONFLICTS BETWEEN MANUFACTURER'S RECOMMENDATIONS, PLANS &
SPECIFICATION REQUIREMENTS TO THE OWNER'S ATTENTION.
FIRE STOPPING NOTE: PLUMBING COORDINATION NOTE:
SAW CUT NOTE:
CONTRACTOR SHALL PROVIDE AN APPROPRIATE LISTED THROUGH- CONTRACTOR SHALL COORDINATE CLOSELY WITH ALL TRADES TO ENSURE
PENETRATION FIRE STOPPING ASSEMBLY AT EACH PENETRATION OF FIRE PLUMBING IS INSTALLED WITHOUT CONFLICTING WITH OTHER BUILDING
CONTRACTOR SHALL VERIFY PIPE INVERTS PRIOR TO SAW CUTTING.
B
RATED CONSTRUCTION (I.E. WALLS AND SLABS, ETC.). FIRE STOPPING OF DUCT SYSTEMS.
CONTRACTOR SHALL SAW CUT, REMOVE AND PATCH CONCRETE FLOOR AS
PENETRATIONS THROUGH RATED ASSEMBLIES ARE ONLY PERMITTED WHEN
REQUIRED TO PERFORM WORK INDICATED. PATCH FLOOR TO MATCH ADJACENT
FIRE AND/ OR SMOKE DAMPERS ARE NOT REQUIRED. SLEEVES SHALL ONLY BE CONTRACTOR SHALL VERIFY AND COORDINATE THE EXACT LOCATION OF ALL
EXISTING CONDITIONS AND NEW CONDITIONS.
PERMITTED WHERE INDICATED IN THE CONTRACTOR SELECTED THROUGH- MECHANICAL, ELECTRICAL, PLUMBING, AND STRUCTURAL SYSTEMS AND
PENETRATION FIRE STOPPING ASSEMBLY. REFER TO ARCHITECTURAL COMPONENTS (EXISTING AND NEW) PRIOR TO COMMENCING WORK.
DRAWINGS FOR LOCATION OF ALL RATED ASSEMBLIES AND ASSOCIATED UL REFER TO ARCHITECTURAL DRAWINGS FOR CONSTRUCTION DETAILS.
DESIGNATIONS. DEVICES INSTALLED RECESSED WITHIN FIRE RATED
WALL WORK NOTE: CONSTRUCTION (I.E. LIGHT SWITCHES, RECEPTACLES, ICE MAKER BOXES, ETC.) CONTRACTOR SHALL VERIFY ALL POINTS OF CONNECTION TO EXISTING
ARE ONLY PERMITTED WHEN AN APPROVED LISTED FIRE STOPPING SYSTEM SYSTEMS, PRIOR TO BEGINNING ANY WORK. THE FAILURE TO COMPLY WITH
EXISTS FOR THE APPLICATION. IF AN APPROVED LISTED FIRE STOPPING THESE DIRECTIONS SHALL NOT CONSTITUTE THE BASIS FOR A CHANGE ORDER
PLUMBING CONTRACTOR SHALL REMOVE PORTIONS OF EXISTING WALLS AS
SYSTEM IS NOT AVAILABLE, THE CONTRACTOR SHALL BRING THE CONDITION TO SHOULD REWORK BE REQUIRED.
REQUIRED FOR ACCESS TO EXISTING PLUMBING PIPING FOR REMODELING
THE ATTENTION OF THE A/E FOR RESOLUTION PRIOR TO PROCEEDING WITH WORK. CONTRACTOR SHALL PATCH TO MATCH EXISTING ADJACENT
WORK. ANY CONDITIONS FOUND THAT WILL PROHIBIT MAKING THE FINAL
CONDITIONS AND RATINGS. REFER TO ARCHITECTURAL PLAN FOR PATCHING
CONNECTIONS(S) OR EXECUTIONS OF THE WORK SHALL BE REPORTED TO THE
DETAILS AND NOTES.
A/E IMMEDIATELY.
PROJECT NO:
CONTRACTOR TO FIELD COORDINATE ALL PIPING LOCATIONS. WHERE THE DATE ISSUED:
EXACT LOCATIONS OF SANITARY PIPING NOT KNOWN, CONTRACTOR TO FIELD
SANITARY SEWER LINE SCOPE NOTE:
TRACE EXACT ROUTING PRIOR TO ANY SAW CUTTING. DESIGNED BY:
OCCUPANCY NOTE:
DRAWN BY:
AS INDICATED IN THESE CONTRACT DOCUMENTS, CONTRACTOR SHALL SCOPE ANY SHUT DOWNS OR INTERRUPTIONS IN SERVICE SHALL BE APPROVED BY
CHECKED BY:
AND SCAN ALL SEWER LINES WITHIN THE PROJECT LIMITS TO DETERMINE AND BUILDING SHALL REMAIN OCCUPIED IN OTHER AREAS OF THE BUILDING. THE OWNER AT LEAST 7 DAYS BEFORE THE WORK IS TO BE EXECUTED. THE
DOCUMENT APPROXIMATE LOCATION, ROUTING, DEBRIS MATTER AND CLOGS CONTRACTOR SHALL TAKE CARE TO NOT INTERRUPT POWER, WATER, HVAC, CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR ANY DELAYS TO THE
PRIOR TO COMMENCEMENT OF WORK. PROVIDE DRAWINGS AND DVD TO ETC. IF SHUT DOWNS OR SHUT OFFS ARE REQUIRED CONTRACTOR SHALL PROJECT THAT ARISE DUE TO HIS FAILURE TO COMPLY WITH THESE A SHEET NAME:
OWNER AND ENGINEER FOR REVIEW. NOTIFY FACILITIES IN WRITING WITH TIME AND SCHEDULE A MINIMUM OF 72 REQUIREMENTS.
HOURS PRIOR TO COMMENCING WORK.
SHEET NO:
ELUDEHCS
ECNAUSSI
NOITPIRCSED
ETAD
REBMUN
TIMOTHY N. HAHN
Lic. No. 058039
06/17/2026
10015069.02
MA
24:44:01
6202/61/6
tvr.gnibmulP
-
75152/42R_063B_BUH
stcejorP
ytiC
-
AV
kloffuS//:scoD
ksedotuA
06/17/2026
D. BOGGS
N. MARIANO
D. BOGGS
LEGEND, NOTES AND
ABBREVIATIONS
P-001
AV
,KLOFFUS
FO
YTIC
GNIDLIUB
TOLIP
NAINIGRIV
-
NIWDOG
NOITAVONER
AV
KLOFFUS
.TS
NIAM
.N
751

SPECIFICATIONS: 1. VITREOUS CHINA ADA COMPLIANT FLOOR MOUNTED FLUSH VALVE WATER CLOSET WITH FULLY GLAZED 2" TRAPWAY, ELONGATED SIPHON JET BOWL, 1.6 GALLONS PER FLUSH. 2. PROVIDE TOTO FLUSH VALVE, MODEL TETIGNC-32. MATERIALS SHALL BE CHLORAMINE RESISTANT. 3. WHITE SOLID PLASTIC OPEN FRONT ELONGATED SEAT WITH EXTERNAL CHECK HINGES, INTEGRAL BUMPERS, LESS COVER. PROVIDE TOTO, CT705L D L W SPECIFICATIONS: 1. KOHLER, VERTICYL 17-1/8" ADA COMPLIANT UNDERMOUNT, RECTANGULAR VITREOUS CHINA SINK, WHITE 2089. 2. KOHLER, TOUCHLESS SINGLE HOLE BATHROOM FAUCET, VIBRANT STAINLESS, MODEL: K-13466-VS. CHROME PLATED SOLID BRASS ELECTRONIC FAUCET WITH PROXIMITY OPERATION SENSORS, POLISH CHROME PLATED FINISH, CERAMIC VALVE, 0.5 GPM VANDAL RESISTANT AERATOR, INTEGRATED STRAINER TO PROTECT SOLENOID VALVE & AERATOR, LESS POP-UP. BELOW DECK THERMOSTATIC MIXING VALVE SET AT 110 degreesF MAX (ASSE 1070). BATTERY OPERATED FAUCET. 3. CHROME FINISH CAST BRASS LOOSE KEY ANGLE STOPS WITH CHROME FINISH RIGID SUPPLY RISERS. OFFSET GRID STRAINER AND ADJUSTABLE 'P'-TRAP. 34" FLOOR SPECIFICATIONS: 1. VITREOUS CHINA ADA COMPLIANT WALL MOUNTED LAVATORY WITH FRONT OVERFLOW AND FAUCET HOLES ON 4" CENTERS AND SELF DRAINING DECK. 2. VIBRANT BRUSHED NICKEL CAST BRASS SINGLE CONTROL CENTERSET FAUCET POLISH VIBRANT BRUSHED NICKEL FINISH, CERAMIC VALVE, ADA COMPLIANT LEVER HANDLE WITH COLOR INDEX, 0.5 GPM VANDAL RESISTANT AERATING SPRAY OUTLET, LESS POP-UP. AS MANUFACTURED BY DELTA. PROVIDE THERMOSTATIC MIXING VALVE SET AT 110 degreesF MAX (ASSE 1070). 3. CHROME FINISH CAST BRASS LOOSE KEY ANGLE STOPS WITH CHROME FINISH RIGID SUPPLY RISERS. OFFSET GRID STRAINER AND CAST BRASS ADJUSTABLE 'P'-TRAP WITH ANSI AND ADA APPROVED, VINYL MOLDED INSULATION WITH NYLON FASTENER KITS, PAINTED AS DIRECTED BY THE ARCHITECT. 4. CONCEALED FLOOR MOUNT SUPPORT. WALL BRACKETS SHALL NOT BE USED. DETAIL BASED ON AMERICAN STANDARD, "LUCERNE" SERIES 30" 48" MAX 38" MIN SPECIFICATIONS: 1. PROVIDE PRESSURE BALANCING VALVE & SWIVEL SHOWER HEAD. 2. PROVIDE ADAWN6036 60" X 36" HUNTINGTON TERRAZO SHOWER FLOOR. 3. ADA COMPLIANT PRESSURE BALANCING VALVE WITH HAND SPRAY & SLIDE BAR (SYMMONS 1--25-FSB FIXED HAND SHOWER WITH SLIDE BAR) DETAIL BASED ON AQUA BATH
MARK DESCRIPTION TRAP HW PIPE SIZES MOUNTING MARK DESCRIPTION TRAP PIPE SIZES MOUNTING MARK DESCRIPTION TRA PIPE SIZES P HW CW WP VP MOUNTING MARK DESCRIPTION TRAP PIPE SIZES HW CW WP VP MOUNTING
CW WP VP HW CW WP VP WP VP CW WP VP
P-1 ADA - FLUSH VALVE WATER CLOSET INTEGRAL - 1" 4" 2" FLOOR P-2 HAND SINK 20"Wx17"Lx6-1/2"D (MIN. BOWL 14"Wx14L"x6-1/2"D) 'P'-TRAP 1/2" 1/2" 2" 1-1/2" UNDER MOUNT P-3 ADA - WALL MOUNTED LAVATORY 1/2" 1/2" 2" 1-1/2" WALL MOUNTED P-4 TRANSFER SHOWER 'P'-TRA P 1/2" 1/2" 2" 1-1/2" FRAMED ENCLOSURE
ADA - WATER CLOSET ADA - UNDERMOUNT LAVATORY ADA - WALL MOUNTED LAVATORY ADA - ROLL IN SHOWER
BOTTLE FILLER SPECIFICATIONS: 1. TWO LEVEL WALL MOUNT STAINLESS STEEL FOUNTAIN WITH RECESSED REFRIGERATION SYSTEM WITH VANDAL RESISTANT BUBBLER, FRONT PANEL GRILL & WALL MOUNTING FRAME. LEAD FREE CONSTRUCTION WITH SATIN STAINLESS FINISH TO SUPPLY 8 GALLONS PER HOUR @ 50 degreesF WITH 80 degreesF ROOM TEMPERATURE. PROVIDE WITH BOTTLE FILLER. 2. CHROME FINISH CAST BRASS LOOSE KEY ANGLE STOPS WITH CHROME FINISH RIGID SUPPLY RISERS. GRID STRAINER & ADJUSTABLE 'P'-TRAP. 3. MOUNT PER MANUFACTURERS INSTRUCTIONS FOR ADA COMPLIANCE. DETAIL BASED ON ELKAY EX5TL8WS D L W SPECIFICATIONS: 1. SEAMLESS DIE DRAWN 18 GAUGE STAINLESS STEEL ADA COMPLIANT SINK WITH EXPOSED SURFACE POLISHED TO A NON-POROUS FINISH. FULLY COATED UNDERSIDE INSULATED FOR SOUND AND CONDENSATE. 2. VIBRANT STAINLESS FINISH SIMPLICE PULL-DOWN KITCHEN SINK FAUCET WITH THREE-FUNCTION SPRAYHEAD. 3. CHROME FINISH CAST BRASS LOOSE KEY ANGLE STOPS WITH CHROME FINISH RIGID SUPPLY RISERS. OFFSET GRID STRAINER AND ADJUSTABLE 'P'-TRAP. 4. PROVIDE WITH IN-SINK-ERATOR (ISE) "BADGER" MODEL 5 GARBAGE DISPOSAL, 1/2 HP, 120 V, 6.3 A. MOP BRACKET HOSE FRP BRACKET 30" HOSE 60" 36" H L W SPECIFICATIONS: 1. MOP BASIN SHALL BE 24"Wx24"Lx10"H SINGLE PIECE MOLDED STONE. 2. FAUCET SHALL BE EXPOSED YOKE WALL MOUNT UTILITY FAUCET WITH CAST BRASS BODY, 1/4 TURN CERAMIC VALVE CARTRIDGES, INTEGRAL VACUUM BREAKER & WALL BRACE. PROVIDE WITH OFFSET SHANKS WITH INTEGRAL STOPS. 3. MOUNT FAUCET 36" AFF. 4. PROVIDE WALL MOUNTED MOP BRACKET, STAINLESS STEEL STRAINER, QUICK DRAIN CONNECTIONS, 30" HOSE & HOSE BRACKET. 5. FRP SHALL EXTEND 2'-0" PAST EDGE OFF FIXTURE. DETAIL BASED ON FIAT, "MOLDED STONE" SERIES
MARK DESCRIPTION TRAP HW PIPE SIZES MOUNTING MARK DESCRIPTION TRAP PIPE SIZES MOUNTING MARK DESCRIPTION TRAP PIPE SIZES HW CW WP VP MOUNTING
CW WP VP HW CW WP VP WP VP
P-5 ADA - DUAL BASIN ELECTRIC WATER COOLER 'P'-TRAP - 1/2" 1-1/2" 1-1/2" WALL MOUNTED P-6 KITCHEN SINK (2 COMPARTMENT) [32" L x 22" W x 6" D] 'P'-TRAP 1/2" 1/2" 2" 1-1/2" UNDER MOUNT P-7 FLOOR MOUNTED MOP BASIN 'P'-TRAP 1/2" 1/2" 3" 1-1/2" FLOOR
ADA - DUAL BASIN WATER COOLER ADA - KITCHEN SINK UNDER MOUNT MOP BASIN

1 2 3 4 5 6
ARCHITECTURE ENGINEERING GEOSPATIAL

4433 CORPORATION LANE
SUITE 125
VIRGINIA BEACH, VA 23462
800.414.1045
30"
E
ALTHOF
E V
W I
N R
O G
D
M I
34" M N
O I
C A
L W
FLOOR
P R O F E S
S IONALEN
GI N E E R
48" MAX
38" MIN
SPECIFICATIONS:
1. VITREOUS CHINA ADA COMPLIANT WALL MOUNTED LAVATORY WITH FRONT
OVERFLOW AND FAUCET HOLES ON 4" CENTERS AND SELF DRAINING DECK.
SPECIFICATIONS:
2. VIBRANT BRUSHED NICKEL CAST BRASS SINGLE CONTROL CENTERSET FAUCET
1. KOHLER, VERTICYL 17-1/8" ADA COMPLIANT UNDERMOUNT, RECTANGULAR VITREOUS
POLISH VIBRANT BRUSHED NICKEL FINISH, CERAMIC VALVE, ADA COMPLIANT LEVER
CHINA SINK, WHITE 2089.
SPECIFICATIONS: HANDLE WITH COLOR INDEX, 0.5 GPM VANDAL RESISTANT AERATING SPRAY OUTLET,
1. VITREOUS CHINA ADA COMPLIANT FLOOR MOUNTED FLUSH VALVE WATER CLOSET LESS POP-UP. AS MANUFACTURED BY DELTA. PROVIDE THERMOSTATIC MIXING VALVE
2. KOHLER, TOUCHLESS SINGLE HOLE BATHROOM FAUCET, VIBRANT STAINLESS,
D
WITH FULLY GLAZED 2" TRAPWAY, ELONGATED SIPHON JET BOWL, 1.6 GALLONS PER SET AT 110 degreesF MAX (ASSE 1070).
MODEL: K-13466-VS. CHROME PLATED SOLID BRASS ELECTRONIC FAUCET WITH
SPECIFICATIONS:
FLUSH.
PROXIMITY OPERATION SENSORS, POLISH CHROME PLATED FINISH, CERAMIC VALVE,
1. PROVIDE PRESSURE BALANCING VALVE & SWIVEL SHOWER HEAD.
3. CHROME FINISH CAST BRASS LOOSE KEY ANGLE STOPS WITH CHROME FINISH RIGID
0.5 GPM VANDAL RESISTANT AERATOR, INTEGRATED STRAINER TO PROTECT
2. PROVIDE TOTO FLUSH VALVE, MODEL TETIGNC-32. MATERIALS SHALL BE SUPPLY RISERS. OFFSET GRID STRAINER AND CAST BRASS ADJUSTABLE 'P'-TRAP SOLENOID VALVE & AERATOR, LESS POP-UP. BELOW DECK THERMOSTATIC MIXING
2. PROVIDE ADAWN6036 60" X 36" HUNTINGTON TERRAZO SHOWER FLOOR.
CHLORAMINE RESISTANT. WITH ANSI AND ADA APPROVED, VINYL MOLDED INSULATION WITH NYLON FASTENER
VALVE SET AT 110 degreesF MAX (ASSE 1070). BATTERY OPERATED FAUCET.
KITS, PAINTED AS DIRECTED BY THE ARCHITECT.
3. ADA COMPLIANT PRESSURE BALANCING VALVE WITH HAND SPRAY & SLIDE BAR
3. WHITE SOLID PLASTIC OPEN FRONT ELONGATED SEAT WITH EXTERNAL CHECK
3. CHROME FINISH CAST BRASS LOOSE KEY ANGLE STOPS WITH CHROME FINISH RIGID
(SYMMONS 1--25-FSB FIXED HAND SHOWER WITH SLIDE BAR)
HINGES, INTEGRAL BUMPERS, LESS COVER. 4. CONCEALED FLOOR MOUNT SUPPORT. WALL BRACKETS SHALL NOT BE USED.
SUPPLY RISERS. OFFSET GRID STRAINER AND ADJUSTABLE 'P'-TRAP.
PROVIDE TOTO, CT705L DETAIL BASED ON AMERICAN STANDARD, "LUCERNE" SERIES DETAIL BASED ON AQUA BATH
PIPE SIZES PIPE SIZES PIPE SIZES PIPE SIZES
MARK DESCRIPTION TRAP MOUNTING MARK DESCRIPTION TRAP MOUNTING MARK DESCRIPTION TRAP MOUNTING MARK DESCRIPTION TRAP MOUNTING
HW CW WP VP HW CW WP VP HW CW WP VP HW CW WP VP
ADA - FLUSH VALVE WATER HAND SINK 20"Wx17"Lx6-1/2"D UNDER WALL FRAMED
P-1 INTEGRAL - 1" 4" 2" FLOOR P-2 'P'-TRAP 1/2" 1/2" 2" 1-1/2" P-3 ADA - WALL MOUNTED LAVATORY 1/2" 1/2" 2" 1-1/2" P-4 TRANSFER SHOWER 'P'-TRAP 1/2" 1/2" 2" 1-1/2"
CLOSET (MIN. BOWL 14"Wx14L"x6-1/2"D) MOUNT MOUNTED ENCLOSURE
ADA - WATER CLOSET ADA - UNDERMOUNT LAVATORY ADA - WALL MOUNTED LAVATORY ADA - ROLL IN SHOWER
C
MOP BRACKET
BOTTLE FILLER
D
L
HOSE
FRP
W BRACKET
30" HOSE
60"
36"
H
B
L W
SPECIFICATIONS:
SPECIFICATIONS:
1. SEAMLESS DIE DRAWN 18 GAUGE STAINLESS STEEL ADA COMPLIANT SINK WITH
1. MOP BASIN SHALL BE 24"Wx24"Lx10"H SINGLE PIECE MOLDED STONE.
SPECIFICATIONS: EXPOSED SURFACE POLISHED TO A NON-POROUS FINISH. FULLY COATED UNDERSIDE
1. TWO LEVEL WALL MOUNT STAINLESS STEEL FOUNTAIN WITH RECESSED INSULATED FOR SOUND AND CONDENSATE.
2. FAUCET SHALL BE EXPOSED YOKE WALL MOUNT UTILITY FAUCET WITH CAST BRASS
REFRIGERATION SYSTEM WITH VANDAL RESISTANT BUBBLER, FRONT PANEL GRILL &
BODY, 1/4 TURN CERAMIC VALVE CARTRIDGES, INTEGRAL VACUUM BREAKER & WALL
WALL MOUNTING FRAME. LEAD FREE CONSTRUCTION WITH SATIN STAINLESS FINISH 2. VIBRANT STAINLESS FINISH SIMPLICE PULL-DOWN KITCHEN SINK FAUCET WITH
BRACE. PROVIDE WITH OFFSET SHANKS WITH INTEGRAL STOPS.
TO SUPPLY 8 GALLONS PER HOUR @ 50 degreesF WITH 80 degreesF ROOM TEMPERATURE. PROVIDE THREE-FUNCTION SPRAYHEAD.
WITH BOTTLE FILLER. 3. MOUNT FAUCET 36" AFF.
3. CHROME FINISH CAST BRASS LOOSE KEY ANGLE STOPS WITH CHROME FINISH RIGID
2. CHROME FINISH CAST BRASS LOOSE KEY ANGLE STOPS WITH CHROME FINISH RIGID SUPPLY RISERS. OFFSET GRID STRAINER AND ADJUSTABLE 'P'-TRAP.
4. PROVIDE WALL MOUNTED MOP BRACKET, STAINLESS STEEL STRAINER, QUICK DRAIN
SUPPLY RISERS. GRID STRAINER & ADJUSTABLE 'P'-TRAP.
CONNECTIONS, 30" HOSE & HOSE BRACKET.
4. PROVIDE WITH IN-SINK-ERATOR (ISE) "BADGER" MODEL 5 GARBAGE DISPOSAL, 1/2 HP,
PROJECT NO:
3. MOUNT PER MANUFACTURERS INSTRUCTIONS FOR ADA COMPLIANCE. 120 V, 6.3 A.
5. FRP SHALL EXTEND 2'-0" PAST EDGE OFF FIXTURE.
DATE ISSUED:
DETAIL BASED ON ELKAY EX5TL8WS DETAIL BASED ON FIAT, "MOLDED STONE" SERIES
DESIGNED BY:
PIPE SIZES PIPE SIZES PIPE SIZES
MARK DESCRIPTION TRAP MOUNTING MARK DESCRIPTION TRAP MOUNTING MARK DESCRIPTION TRAP MOUNTING DRAWN BY:
HW CW WP VP HW CW WP VP HW CW WP VP
CHECKED BY:
ADA - DUAL BASIN ELECTRIC WALL KITCHEN SINK (2 COMPARTMENT) UNDER
P-5 'P'-TRAP - 1/2" 1-1/2" 1-1/2" P-6 'P'-TRAP 1/2" 1/2" 2" 1-1/2" P-7 FLOOR MOUNTED MOP BASIN 'P'-TRAP 1/2" 1/2" 3" 1-1/2" FLOOR
WATER COOLER MOUNTED [32" L x 22" W x 6" D] MOUNT
A SHEET NAME:
ADA - DUAL BASIN WATER COOLER ADA - KITCHEN SINK UNDER MOUNT MOP BASIN
SHEET NO:
ELUDEHCS
ECNAUSSI
NOITPIRCSED
ETAD
REBMUN
TIMOTHY N. HAHN
Lic. No. 058039
06/17/2026
10015069.02
MA
34:44:01
6202/61/6
tvr.gnibmulP
-
75152/42R_063B_BUH
stcejorP
ytiC
-
AV
kloffuS//:scoD
ksedotuA
06/17/2026
D. BOGGS
N. MARIANO
D. BOGGS
FIXTURE PLATES
P-002
AV
,KLOFFUS
FO
YTIC
GNIDLIUB
TOLIP
NAINIGRIV
-
NIWDOG
NOITAVONER
AV
KLOFFUS
.TS
NIAM
.N
751

P- DN, ETR
5 UP
1
2
3
4
5
6
AND CAP. PATCH FLOOR TO MATCH EXISTING ADJACENT CONDI
7
8
9
PIPING FOR OFFSET TO NEW LOCATION PER NEW WORK PLAN.
/8"=1' -0"

1 2 3 4 5 6
ARCHITECTURE ENGINEERING GEOSPATIAL

4433 CORPORATION LANE
SUITE 125
VIRGINIA BEACH, VA 23462
800.414.1045
E
UP
ALTHOF
E V
5 N W I R
8 O G
M I
M N
O I
C A
WP-UP, ETR
3 3 P R O F E S
S IONALEN
GI N E E R
2
8
WP-AC 6 9
1
D
5
WP-DN, ETR
3
5
UP
5 5
10 4
7
5
C
3 2
10 10
1 5
8
3
3
7
2
5 5
5
8 8 5 5
EXISTING WATER
UP
SERVICE TO REMAIN 1
8
B
1 REMOVE EXISTING WATER CLOSETS COMPLETE. REMOVE WATER TO EXTENT 10 REMOVE EXISTING WATER AND WASTE ROUGH-IN PIPING SERVING PREVIOUS DENTAL
INDICATED ON PLAN. REMOVE VENT PIPING TO PENETRATION OF SECOND FLOOR EQUIPMENT. REMOVE WATER AND VENT PIPING TO MAINS. REMOVE WASTE PIPE TO
AND RETAIN FOR EXTENSION TO NEW FIXTURES. REMOVE WASTE PIPING TO BELOW BELOW FLOOR AND CAP.
FLOOR AND CAP. PATCH FLOOR TO MATCH EXISTING ADJACENT CONDITIONS.
2 REMOVE EXISTING LAVATORY COMPLETE. REMOVE WATER TO EXTENT INDICATED ON
PLAN. REMOVE VENT PIPING TO PENETRATION OF SECOND FLOOR AND RETAIN FOR
EXTENSION TO NEW FIXTURES. REMOVE WASTE PIPING TO BELOW FLOOR AND CAP.
PATCH FLOOR TO MATCH EXISTING ADJACENT CONDITIONS.
3 REMOVE EXISTING WATER HEATER COMPLETE. REMOVE WATER TO EXTENT
INDICATED ON PLAN.
4 REMOVE EXISTING SERVICE SINK COMPLETE. REMOVE WATER TO EXTENT INDICATED PROJECT NO:
ON PLAN. REMOVE VENT PIPING TO PENETRATION OF SECOND FLOOR AND RETAIN
DATE ISSUED:
FOR EXTENSION TO NEW FIXTURES. REMOVE WASTE PIPING TO BELOW FLOOR AND
CAP. PATCH FLOOR TO MATCH EXISTING ADJACENT CONDITIONS.
DESIGNED BY:
DRAWN BY:
5 REMOVE EXISTING COUNTERTOP SINK COMPLETE. MOVE WASTE PIPING TO BELOW
FLOOR AND CAP. PATCH FLOOR TO MATCH EXISTING ADJACENT CONDITIONS. CHECKED BY:
6 REMOVE EXISTING URINAL COMPLETE. REMOVE WASTE PIPING TO BELOW FLOOR A SHEET NAME:
AND CAP. PATCH FLOOR TO MATCH EXISTING ADJACENT CONDITIONS.
7 REMOVE CW AND HW COMPLETE TO TOP OF EXISTING WATER SERVICE RISER.
8 REMOVE EXISTING FIXTURE COMPLETE. RETAIN EXISTING ROUGH IN FOR FUTURE
NEW WORK CONNECTION.
0 4' 8' 16' 24'
9 REMOVE 4" STACK FROM ABOVE CEILING TO BELOW FLOOR. PREPARE REMAINING
1/8"=1'-0"
PIPING FOR OFFSET TO NEW LOCATION PER NEW WORK PLAN. SHEET NO:
ELUDEHCS
ECNAUSSI
NOITPIRCSED
ETAD
REBMUN
TIMOTHY N. HAHN
Lic. No. 058039
06/17/2026
10015069.02
GRAPHIC SCALE:
MA
64:44:01
6202/61/6
tvr.gnibmulP
-
75152/42R_063B_BUH
stcejorP
ytiC
- AV
kloffuS//:scoD
ksedotuA
06/17/2026
D. BOGGS
N. MARIANO
D. BOGGS
OVERALL FIRST FLOOR
PLAN - DEMOLITION
PD-101
AV
,KLOFFUS
FO
YTIC
GNIDLIUB
TOLIP
NAINIGRIV
-
NIWDOG
NOITAVONER
AV
KLOFFUS
.TS
NIAM
.N
751
PLAN NORTH
OVERALL DEMOLITION PLAN
B1
SCALE: 1/8" = 1'-0"
NOTES THIS SHEET

1
1
1
1
1
1
1 REMOVE EXISTING ROOF DRAIN BODY COMPLETE. RETAIN
EXISTING RAIN LEADER PIPING FOR CONNECTION TO NEW
ROOF DRAIN PER NEW WORK PLAN.
1/8"=1'- 0"

1 2 3 4 5 6
ARCHITECTURE ENGINEERING GEOSPATIAL

4433 CORPORATION LANE
SUITE 125
VIRGINIA BEACH, VA 23462
800.414.1045
E
ALTHOF
E V
W I
N R
O G
M I
M N
O I
C A
P R O F E S
S IONALEN
GI N E E R
1
1
D
1
1
1 1
1
EXISTING VTR TO REMAIN
C
B
1 REMOVE EXISTING ROOF DRAIN BODY COMPLETE. RETAIN
EXISTING RAIN LEADER PIPING FOR CONNECTION TO NEW
ROOF DRAIN PER NEW WORK PLAN.
PROJECT NO:
DATE ISSUED:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
A SHEET NAME:
0 4' 8' 16' 24'
1/8"=1'-0"
SHEET NO:
ELUDEHCS
ECNAUSSI
NOITPIRCSED
ETAD
REBMUN
TIMOTHY N. HAHN
Lic. No. 058039
06/17/2026
10015069.02
GRAPHIC SCALE:
MA
74:44:01
6202/61/6
tvr.gnibmulP
-
75152/42R_063B_BUH
stcejorP
ytiC
-
AV
kloffuS//:scoD
ksedotuA
06/17/2026
D. BOGGS
N. MARIANO
D. BOGGS
OVERALL ROOF PLAN -
DEMOLITION
PD-102
AV
,KLOFFUS
FO
YTIC
GNIDLIUB
TOLIP
NAINIGRIV
-
NIWDOG
NOITAVONER
AV
KLOFFUS
.TS
NIAM
.N
751
PLAN NORTH
OVERALL ROOF PLAN - DEMOLITION
B1
SCALE: 1/8" = 1'-0"
NOTES THIS SHEET

ROOM NAME
VESTIBULE
LOBBY
CLOSET
VICTIM WITNESS CONFEREN
COPY AREA
STAIR 1
STOR
CONFERENCE
VICTIM WITNESS DIRECTOR
TLT
ADA TLT
CORRIDOR
VICTIM WITNESS SUITE
INVESTIGATOR SUITE
STORAGE
CHIEF INVESTIGATOR
ASSISTANT CW ATTORNEY
ASSISTANT CW ATTORNEY
ASSISTANT CW ATTORNEY
ASSISTANT CW ATTORNEY
ASSISTANT CW ATTORNEY
# ROOM NAME
SPRINKLER
ELEV
STORAGE
STORAGE
COMM/DATA /ELEC
STORAGE
WOMENS SHOWER
MENS SHOWER
CORRIDOR
ADA TLT
POLICE WELLNESS
ELEC
ELEC
STAIR 3
STORAGE
CORRIDOR
MOTHERS ROOM
STORAGE
STAIR 2
1/8"=1'- 0"

1 2 3 4 5 6
WCO
ARCHITECTURE ENGINEERING GEOSPATIAL

4433 CORPORATION LANE
SUITE 125
174
162 175 160 VIRGINIA BEACH, VA 23462
P-1 P-1 161
800.414.1045
P-4 P-4
178
167 166 165 164
173
P-2 P-2 163 E
155 156 157 158
3" FD E
ALTHOF
V
172 W/TG 1 P-5 154 N W I R
O G
168 1 P-3 M I
P-7 M N
FCO O I
C A
1
171 WP UP TO P601 169 P P - - 2 1 P-2 176 177 142 153 1 P-1 P R O F E S S IONALEN GI N E E R
SECOND FLOOR 2 159
3
152
144
141 1 P-3 4
151
170
P-6
3" WP AC 140
FCO
D
145 148
FCO
150
P-6
101
102
130 131 132 133 134 135 139 149
146 147 2
P-5
P601
103
115
143
129
114 113 104
137 138
136 116
C
128
112 105
1 P-5
1 P-2 1 P-2
107
125 124 123 122 121 120 119 118 117
111 110 109 108
127 126
1 P-2 1 P-2 106
1 P-1 1 P-1
1 P-1
1 INSTALL NEW FIXTURE. CONNECT TO
B
EXISTING ROUGH-IN PIPING.
2 EXTEND 4" FROM EXISTING STACK
LOCATION TO NEW STACK LOCATION.
3 NEW 4" STACK.
4 EXTEND NEW 4" TO EXISTING PIPE
BELOW FLOOR.
PROJECT NO:
DATE ISSUED:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
A SHEET NAME:
0 4' 8' 16' 24'
1/8"=1'-0"
SHEET NO:
ELUDEHCS
ECNAUSSI
NOITPIRCSED
ETAD
REBMUN
TIMOTHY N. HAHN
Lic. No. 058039
06/17/2026
10015069.02
GRAPHIC SCALE:
MA
05:44:01
6202/61/6
tvr.gnibmulP
-
75152/42R_063B_BUH
stcejorP
ytiC
-
AV
kloffuS//:scoD
ksedotuA
06/17/2026
D. BOGGS
N. MARIANO
D. BOGGS
OVERALL FIRST FLOOR
SANITARY PLAN - NEW
WORK
P-101
AV
,KLOFFUS
FO
YTIC
GNIDLIUB
TOLIP
NAINIGRIV
-
NIWDOG
NOITAVONER
AV
KLOFFUS
.TS
NIAM
.N
751
PLAN NORTH
OVERALL NEW CONSTRUCTION SANITARY PLAN
B1
SCALE: 1/8" = 1'-0"
NOTES THIS SHEET
OVERALL ROOM OVERALL ROOM OVERALL ROOM OVERALL ROOM
SCHEDULE SCHEDULE SCHEDULE SCHEDULE
RM # ROOM NAME RM # ROOM NAME RM # ROOM NAME RM # ROOM NAME
101 VESTIBULE 122 DEPUTY CA 141 ASSISTANT CW ATTORNEY 160 SPRINKLER
102 LOBBY 123 DEPUTY CA 142 ASSITANT CW ATTORNEY 161 ELEV
103 CLOSET 124 DEPUTY CA 143 CORRIDOR 162 STORAGE
104 VICTIM WITNESS CONFERENCE 125 CHIEF DEPUTY CA 144 BREAK ROOM 163 STORAGE
105 COPY AREA 126 ADA TLT 145 COPY 164 COMM/DATA /ELEC
106 STAIR 1 127 TLT 146 ASSISTANT CW ATTORNEY 165 STORAGE
107 STOR 128 STAFF ENTRY 147 CORRIDOR 166 WOMENS SHOWER
108 CONFERENCE 129 CONFERENCE 148 BREAK 167 MENS SHOWER
109 VICTIM WITNESS DIRECTOR 130 HEAD CW ATTORNEY OFFICE 149 STORAGE 168 CORRIDOR
110 TLT 131 CHIEF ADMIN MANAGER 150 CONFERENCE 169 ADA TLT
111 ADA TLT 132 SUPERVISOR 151 STORAGE 170 POLICE WELLNESS
112 CORRIDOR 133 ASSISTANT CW ATTORNY 152 ADA TLT 171 ELEC
113 VICTIM WITNESS SUITE 134 ASSISTANT CW ATTORNEY 153 TLT 172 ELEC
114 INVESTIGATOR SUITE 135 ASISSTANT CW ATTORNEY 154 JANITOR 173 STAIR 3
115 STORAGE 136 COMMONWEALTH ATTORNEY 155 CHIEF ANIMAL CONTROL 174 STORAGE
OPEN OFFICE OFFICER 116 CHIEF INVESTIGATOR 175 CORRIDOR
117 ASSISTANT CW ATTORNEY 137 ASSISTANT CW ATTORNEY 156 SARGEANT 176 MOTHERS ROOM
118 ASSISTANT CW ATTORNEY 138 CEASE FIRE CA 157 SARGEANT 177 STORAGE
119 ASSISTANT CW ATTORNEY 139 CONFERENCE 158 HEAD POLICE OFFICER - 178 STAIR 2
TRAINING COORD. 120 ASSISTANT CW ATTORNEY 140 ASSISTANT CW ATTORNEY
159 POLICE DEPT. OPEN OFFICE
121 ASSISTANT CW ATTORNEY

PROVIDE 4" ROOF DRAIN BODY
COMPLETE. MODIFY EXISTING RAIN
LEADER PIPING AS REQUIRED TO SUIT
NEW ROOF DRAIN ASSEMBLY
1/8"=1'- 0

1 2 3 4 5 6
ARCHITECTURE ENGINEERING GEOSPATIAL

4433 CORPORATION LANE
SUITE 125
VIRGINIA BEACH, VA 23462
800.414.1045
E
ALTHOF
E V
W I
N R
O G
M I
M N
O I
C A
P R O F E S
S IONALEN
GI N E E R
1
1
D
1
1
1
1
1
EXISTING VTR TO REMAIN
C
B
1 PROVIDE 4" ROOF DRAIN BODY
COMPLETE. MODIFY EXISTING RAIN
LEADER PIPING AS REQUIRED TO SUIT
NEW ROOF DRAIN ASSEMBLY
PROJECT NO:
DATE ISSUED:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
A SHEET NAME:
0 4' 8' 16' 24'
1/8"=1'-0"
SHEET NO:
ELUDEHCS
ECNAUSSI
NOITPIRCSED
ETAD
REBMUN
TIMOTHY N. HAHN
Lic. No. 058039
06/17/2026
10015069.02
GRAPHIC SCALE:
MA
15:44:01
6202/61/6
tvr.gnibmulP
-
75152/42R_063B_BUH
stcejorP
ytiC
-
AV
kloffuS//:scoD
ksedotuA
06/17/2026
D. BOGGS
N. MARIANO
D. BOGGS
OVERALL ROOF PLAN -
NEW WORK
P-102
AV
,KLOFFUS
FO
YTIC
GNIDLIUB
TOLIP
NAINIGRIV
-
NIWDOG
NOITAVONER
AV
KLOFFUS
.TS
NIAM
.N
751
PLAN NORTH
OVERALL ROOF PLAN - NEW WORK
B1
SCALE: 1/8" = 1'-0"
NOTES THIS SHEET

174 P-4 167 1 173 P-2 P 2 WH-1/HWRP-1 TO HWRP-1 1 P-5 162 175 161 P-4 178 66 165 164 -2 163 154 155 156 157 158 168 1 P-3 P-7 160
172 171
130 129 128 1
1
127 126
VERALL ROOM SCHEDULE
ROOM NAME
ASSISTANT CW ATTORNEY
ASSITANT CW ATTORNEY
CORRIDOR
BREAK ROOM
COPY
ASSISTANT CW ATTORNEY
CORRIDOR
BREAK
STORAGE
CONFERENCE
STORAGE
ADA TLT
TLT
JANITOR
CHIEF ANIMAL CONTROL OFFICER
SARGEANT
SARGEANT
HEAD POLICE OFFICER - TRAINING COORD.
POLICE DEPT. OPEN OFFICE
OVERALL ROO SCHEDULE
# ROOM NAME
SPRINKLER
ELEV
STORAGE
STORAGE
COMM/DATA /ELEC
STORAGE
WOMENS SHOWER
MENS SHOWER
CORRIDOR
ADA TLT
POLICE WELLNESS
ELEC
ELEC
STAIR 3
STORAGE
CORRIDOR
MOTHERS ROOM
STORAGE
STAIR 2
ROOM NAME
VESTIBULE
LOBBY
CLOSET
TIM WITNESS CONFERENC
COPY AREA
STAIR 1
STOR
CONFERENCE
ICTIM WITNESS DIRECTOR
TLT
ADA TLT
CORRIDOR
VICTIM WITNESS SUITE
INVESTIGATOR SUITE
STORAGE
CHIEF INVESTIGATOR
SSISTANT CW ATTORNEY
SSISTANT CW ATTORNEY
SSISTANT CW ATTORNEY
SSISTANT CW ATTORNEY
SSISTANT CW ATTORNEY
1/8"=1'- 0"

1 2 3 4 5 6
6" SPRINKLER
P-1 RISER, ETR
ARCHITECTURE ENGINEERING GEOSPATIAL

4433 CORPORATION LANE
SUITE 125
174 FDC,
162 175 160 VIRGINIA BEACH, VA 23462
161 ETR
800.414.1045
P-4
P-4 178
167 166 165 164
173
P-2 P-2 163 E
2 WH-1/HWRP-1
154 155 156 157 158
ALTHOF
E V
W I
TO HWRP-1 N R
O G
168 M I
1 P-5 P-2 1 P-3 P-7 M N
O I
C A
172
171 169 176 177
142
1 P-1
153 P R O F E S
S IONALEN
GI N E E R
P-1 159
152
144
141 1 P-3
151
170
140
D
P-6
145 148
150
P-6
101
130 131 132 133 134 135 139 149 102
146 147
P-5
103
EXISTING INCOMING
115 WATER SERVICE
143
129
114 113 104
137 138
136 116
C
128
112
1 P-5 105
1 P-2
1 P-2
107
125 124 123 122 121 120 119 118 117 109 108
127 126 111 110
3
106
1 P-1
1 P-1 1 P-2 1 P-2
1 P-1
1 INSTALL NEW FIXTURE, EXTEND NEW
WATER TO EXISTING FIXTURE ROUGH
B
IN ABOVE CEILING.
2 PROVIDE NEW WATER HEATER. SEE
DETAIL ON SHEET P501 FOR MORE
INFORMATION.
3 EXTEND NEW CW FROM EXISTING CW
ABOVE CEILING.
PROJECT NO:
DATE ISSUED:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
A SHEET NAME:
0 4' 8' 16' 24'
1/8"=1'-0"
SHEET NO:
ELUDEHCS
ECNAUSSI
NOITPIRCSED
ETAD
REBMUN
TIMOTHY N. HAHN
Lic. No. 058039
06/17/2026
10015069.02
GRAPHIC SCALE:
MA
65:44:01
6202/61/6
tvr.gnibmulP
-
75152/42R_063B_BUH
stcejorP
ytiC
- AV
kloffuS//:scoD
ksedotuA
06/17/2026
D. BOGGS
N. MARIANO
D. BOGGS
OVERALL FIRST FLOOR
DOMESTIC WATER PLAN -
NEW WORK
P-201
AV
,KLOFFUS
FO
YTIC
GNIDLIUB
TOLIP
NAINIGRIV
-
NIWDOG
NOITAVONER
AV
KLOFFUS
.TS
NIAM
.N
751
PLAN NORTH
OVERALL NEW CONSTRUCTION DOMESTIC WATER PLAN
B1
SCALE: 1/8" = 1'-0"
NOTES THIS SHEET
OVERALL ROOM OVERALL ROOM OVERALL ROOM OVERALL ROOM
SCHEDULE SCHEDULE SCHEDULE SCHEDULE
RM # ROOM NAME RM # ROOM NAME RM # ROOM NAME RM # ROOM NAME
101 VESTIBULE 122 DEPUTY CA 141 ASSISTANT CW ATTORNEY 160 SPRINKLER
102 LOBBY 123 DEPUTY CA 142 ASSITANT CW ATTORNEY 161 ELEV
103 CLOSET 124 DEPUTY CA 143 CORRIDOR 162 STORAGE
104 VICTIM WITNESS CONFERENCE 125 CHIEF DEPUTY CA 144 BREAK ROOM 163 STORAGE
105 COPY AREA 126 ADA TLT 145 COPY 164 COMM/DATA /ELEC
106 STAIR 1 127 TLT 146 ASSISTANT CW ATTORNEY 165 STORAGE
107 STOR 128 STAFF ENTRY 147 CORRIDOR 166 WOMENS SHOWER
108 CONFERENCE 129 CONFERENCE 148 BREAK 167 MENS SHOWER
109 VICTIM WITNESS DIRECTOR 130 HEAD CW ATTORNEY OFFICE 149 STORAGE 168 CORRIDOR
110 TLT 131 CHIEF ADMIN MANAGER 150 CONFERENCE 169 ADA TLT
111 ADA TLT 132 SUPERVISOR 151 STORAGE 170 POLICE WELLNESS
112 CORRIDOR 133 ASSISTANT CW ATTORNY 152 ADA TLT 171 ELEC
113 VICTIM WITNESS SUITE 134 ASSISTANT CW ATTORNEY 153 TLT 172 ELEC
114 INVESTIGATOR SUITE 135 ASISSTANT CW ATTORNEY 154 JANITOR 173 STAIR 3
115 STORAGE 136 COMMONWEALTH ATTORNEY 155 CHIEF ANIMAL CONTROL 174 STORAGE
OPEN OFFICE OFFICER
116 CHIEF INVESTIGATOR 175 CORRIDOR
117 ASSISTANT CW ATTORNEY 137 ASSISTANT CW ATTORNEY 156 SARGEANT 176 MOTHERS ROOM
118 ASSISTANT CW ATTORNEY 138 CEASE FIRE CA 157 SARGEANT 177 STORAGE
119 ASSISTANT CW ATTORNEY 139 CONFERENCE 158 HEAD POLICE OFFICER - 178 STAIR 2
TRAINING COORD.
120 ASSISTANT CW ATTORNEY 140 ASSISTANT CW ATTORNEY
159 POLICE DEPT. OPEN OFFICE 121 ASSISTANT CW ATTORNEY

ELECTRIC WATER HEATER SCHEDULE
TAG TYPE LOCATION STORAGE (GAL) RECOVERY (GPH) ELECTRICAL DATA EXPANSION TANK MOUNTING REMARKS
KILOWATTS VOLTS PHASE TOTAL VOLUME (GAL) ACCEPTANCE VOLUME (GAL)
80 degreesF 100 degreesF
WH-1 TANK RM 172 80 46 36 9.0 208 3 1.8 0.8 FLOOR SEE NOTES
DOMESTIC HOT WATER RECIRCULATING PUMP SCHEDULE
TAG TYPE GPM HEAD LOCATION HP VOLTS PHASE REMARKS
HWRP-1 INLINE CIRCULATOR 2 15 RM 172 1/8 115 SINGLE SEE NOTES
This is the opportunity summary page. It provides an overview of this opportunity and a preview of the attached documentation.
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

Number 26-2992-8EAR Title Tuckahoe Library Stream Restoration Available Date 8/13/2026 11:40 AM Clarification

Henrico County

Bid Due: 9/22/2026

Mowing Services Status: Open RFP 126418 Town of Smithfield -Town of Smithfield Closing

State Government of Virginia

Bid Due: 9/18/2026

720-5250 Crisis Facility Training Integration Status: Open RFP 126446 Department of Behavioral Health

State Government of Virginia

Bid Due: 10/05/2026

Human Services Case & Financial Management System Status: Open RFP 126447 City of

State Government of Virginia

Bid Due: 9/18/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.