6515--Fort Harrison VA Medical Center (North) 436 AB Scanner (VA-25-00075498)
| Location: |
Montana |
| Posted: |
Jun 3, 2025 |
| Due: |
Jun 10, 2025 |
| Agency: |
VETERANS AFFAIRS, DEPARTMENT OF |
| Type of Government: |
Federal |
| Category: |
- 65 - Medical, Dental, and Veterinary Equipment and Supplies
|
| Solicitation No: |
36C25925Q0495 |
| Publication URL: |
To access bid details, please log in. |
6515--Fort Harrison VA Medical Center (North) 436 AB Scanner (VA-25-00075498)
Active
Contract Opportunity
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
NETWORK CONTRACT OFFICE 19 (36C259)
Looking for contract opportunity help?
General Information
-
Contract Opportunity Type: Sources Sought (Original)
-
Original Published Date: Jun 03, 2025 03:35 pm MDT
-
Original Response Date: Jun 10, 2025 12:00 pm MDT
-
Inactive Policy: Manual
-
Original Inactive Date:
Aug 09, 2025
-
Initiative:
Classification
Description
Sources Sought Notice A/B SCAN SYSTEM
DISCLAIMER
This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
Response Instructions:
Do not provide more than 8 pages, including cover letter page.
Submit your response via email to: barron.long@va.gov
Submit your response NLT 12:00 (MST) on Tuesday June 10th
Mark your response as Proprietary Information if the information is considered business sensitive.
VA has identified the appropriate North American Industry Classification System (NAICS) Code 339112 Surgical and Medical Instrument Manufacturing with a Small Business size of 1000 employees. Please identify and explain any NAICS codes your company believes would better represent the predominated work included in the attached Statement of Work draft / Salient Characteristics List;
Information Requested from Industry:
In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses accordance with the Statement of Work draft / Salient Characteristics List.
Vendor Name:
SAM UEI #:
Name of Manufacturer:
Manufacturer Address:
Estimated Delivery Time:
SAC FSS contract number
Vendor Point of Contract (POC) Name
POC Phone Number:
POC Email Address:
Statement of Work
A/B scan instrument MUST be on the approved list of equipment for Forum compatibility must have an ERA and be Vista Approved
Must have DICOM compliance capability.
A/B scan probes must be detachable so it can be processed by SPS in accordance with our disinfecting policy.
Must have A-scan and B-scan options for measuring eye length and retinal thickness or lesion thickness.
Due to space constraints of room equipment will be utilized in, need a single unit with interchangeable probes no larger than 15 x15 footprint.
Due to limited space constraints and sensitive electrical equipment, must be direct contact A-scan NOT immersion for obtaining readings.
Needs foot pedal to obtain readings so do not have to resituate while taking readings.
Must plug into standard US outlet.
Must be MADE IN THE USA
Manufacturer must set up equipment and provide instructional training to provider and technicians.
Task 1 - Enterprise Management Controls.
Subtask 1 A/B Scan equipment and software must be compatible with Forum which is in place across VA Montana. Instrument will be used to take axial length, anterior chamber depth, white to white, and lesion thickness measurements, then transmit those measurements to the VA internal platform Forum where they can be assessed by the doctor. There is a specific list of approved devices that have been validated through the VistA database for compatibility with Forum. Any equipment that is not on the list is not guaranteed to work with Forum which is established and utilized throughout VA Montana, and the rigorous testing process to see if a piece of equipment is compatible take almost 12 months.
Security Requirements
Interfaces with Forum an internal storage platform that is already in use across VA Montana.
7. Place of Performance.
Will be in the Billings VA Ophthalmology Clinic to be used by the ophthalmologist or ophthalmology technician on staff for measurements unable to be obtained by IOL master or OCT or to get an idea of retinal layers when view into eye is obstructed.
8. Delivery Schedule.
Contracted vendor will deliver to Billings VA (Benjamin Steele) and coordinate with Biomed for installation in the exam room on a date when the doctor in not seeing patients. Once the instrument has been set up Biomed with work with Ophthalmology department to schedule a training with the manufacturer to provide education on functionality and performance.
Attachments/Links
Contact Information
Contracting Office Address
-
6162 S WILLOW DR SUITE 300
-
Greenwood Village , CO 80111
-
USA
Secondary Point of Contact
History
-
Jun 03, 2025 03:35 pm MDTSources Sought (Original)
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.