Dix Park Stabilization – Window Boarding

Location: North Carolina
Posted: Aug 14, 2025
Due: Aug 29, 2025
Agency: State Government of North Carolina
Type of Government: State & Local
Category:
  • Z - Maintenance, Repair or Alteration of Real Property
Solicitation No: 274-ES-FO-FY26-DixParkWindowBoarding
Publication URL: To access bid details, please log in.
Solicitation Number: 274-ES-FO-FY26-DixParkWindowBoarding
Project Title: Dix Park Stabilization – Window Boarding
Description: All windows, glass doors, and glass present in a metal or wood door, including all windows on the first level of buildings and windows/doors within 8 feet of ground level, will be covered with minimum ¾ inch Severe Weather CCX grade plywood. This is to also include anything below the ground level that may be accessible or accessible from a horizontal reach from the ground or platform area within 4 feet. Plywood should be secured into the framing around the windows and doors. All doors should remain operable (screws into the metal part of the door are acceptable). Windows and doors of buildings that have current cages/bars are to be covered with plywood as well. Any foundation penetrations that would lead to access to the building basements for crawl space will be covered with same plywood material.
Opening Date: 8/29/2025 2:00 PM
Posted Date: 8/15/2025
Status: Open
Department: CITY OF RALEIGH
Solicitation Number
*
274-ES-FO-FY26-DixParkWindowBoarding
Department
CITY OF RALEIGH
Status Reason
Open
Opening Date
2025-08-29T14:00:00.0000000
Posted Date
*
2025-08-14T19:52:50.0000000Z
Commodity Code
Construction Services
Mandatory Conference/Site Visit
—
—
Special Instructions
Project Manager Contact: Tommy Mangum e-mail: Tommy.Mangum@raleighnc.gov
Description
All windows, glass doors, and glass present in a metal or wood door, including all windows on the first level of buildings and windows/doors within 8 feet of ground level, will be covered with minimum ¾ inch Severe Weather CCX grade plywood. This is to also include anything below the ground level that may be accessible or accessible from a horizontal reach from the ground or platform area within 4 feet. Plywood should be secured into the framing around the windows and doors. All doors should remain operable (screws into the metal part of the door are acceptable). Windows and doors of buildings that have current cages/bars are to be covered with plywood as well. Any foundation penetrations that would lead to access to the building basements for crawl space will be covered with same plywood material.
Attachments
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

..., windows, storefront and curtain wall; interior framing and finishes; casework; and complete ...

State Government of North Carolina

Bid Due: 12/08/2026

...- Stone 05b - Cold Form Metal Framing 06f - Architectural Woodwork 06x ...

University of North Carolina System

Bid Due: 11/12/2026

...- Cold Form Metal Framing 06f - Architectural Woodwork 06x - Solid Surface ...

University of North Carolina System

Bid Due: 11/12/2026

...Framing & Drywall, BP-09B Acoustical Ceilings, BP-09D Painting & Wallcovering. BP-09E Carpet...

Wake County Public School System

Bid Due: 11/10/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.