| Location: | Maryland |
|---|---|
| Posted: | Jun 12, 2026 |
| Due: | Jun 23, 2026 |
| Agency: | COMMERCE, DEPARTMENT OF |
| Type of Government: | Federal |
| Category: |
|
| Solicitation No: | 1333ND26QNB680282 |
| Publication URL: | To access bid details, please log in. |
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
The NIST neutron imaging team, in the Radiation Physics Division of the Physical Measurement Laboratory, is developing a far-field grating neutron interferometer to measure the projection of the pair correlation function, G(Z), of a sample of interest. This interferometer geometry requires precision alignment of 3 gratings about the roll direction of the neutron beam. Since G(Z) is a vector quantity, aligned perpendicular to the grating direction, the grating alignment stages need to be able to rotate a full 360°, with high resolution. The gratings are lines etched into silicon wafers, where the period of the lines is of order 1 micrometer and the wafers are 100 mm in diameter. The mass of a grating, including a holder is of order 100 g. The interferometer pattern is measured by translating one of the gratings, so that that mass of the alignment system must be kept to as low as achievable. For control hardware, the separation of two of the gratings along the beam ranges from 1 mm to 300 mm. The third grating is separated by up to 5 m. The overall grating alignment system requires translating the gratings in the vertical direction, requiring that the grating roll stages (which much also translate) be less than 1 kg in mass.
This procurement is to obtain quantity three high precision rotation stages (resolution better than 0.00005 degrees) with a clear aperture to allow the beam to pass unattenuated and required cabling, control hardware, and control software.

With GovernmentContracts, you can:
.... These specimens are prepared using a dual-beam focused ion beam scanning electron ...
COMMERCE, DEPARTMENT OF
Bid Due: 7/24/2026
...a hybrid crystalline and ion beam sputtered coating. Crystalline coating component comprises...
COMMERCE, DEPARTMENT OF
Bid Due: 7/23/2026
...beam 160-leaf multileaf collimator (MLC) Onboard 1.5 Tesla (or greater) magnetic resonance imaging... ...
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Bid Due: 7/30/2026
...procedures. Is there an alternative welding method(s) (i.e. Robotic, electron beam, friction stir, ...
DEPT OF DEFENSE
Bid Due: 8/07/2026