Annual Contract for Submersible Pump Repair

Location: Alabama
Posted: Oct 19, 2026
Due: Nov 19, 2026
Agency: Mobile Water Service System(MAWSS)
Type of Government: State & Local
Category:
  • 43 - Pumps and Compressors
  • J - Maintenance, Repair, and Rebuilding of Equipment
Solicitation No: IFB 26-060
Publication URL: To access bid details, please log in.

Annual Contract for Submersible Pump Repair

  • Contract or Solicitation Number IFB 26-060

  • Solicitation Description

    Contract Period: 1/1/27 through 12/31/27 with two 1-year ext. opt.

    A mandatory Pre-Bid meeting will be held prior to the bid opening at 10:00 am on November 6, 2026, in the MAWSS Operations Center Board Room located at 4725 Moffett Rd., Mobile, AL 36618 at the East Visitor Entrance.

  • Opening Date November 19th 2026

  • Contact Lane Cook (256) 520-0856 lane.cook@jacobs.com
    David Stejskal (251) 591-9248 david.stejskal@jacobs.com

  • Solicitation Document(s)

    IFB26-060SubmersiblePumpRepairAnnualContract_2026-10-19-110057.pdf

Attachment Preview

INVITATION FOR BID NUMBER IFB 26-060
NAME OF BID Annual Contract for Submersible Pump Repair
BIDS WILL BE RECEIVED AT MAWSS Purchasing Dept. Bid Box If sending bids by UPS/Fed Ex, deliver to: East Visitor Entrance 1610 Shelton Beach Rd. Ext., Mobile, AL 36618 4725 Moffett Road Attn: Purchasing Mobile, AL 36618 with IFB# marked on envelope
MANDATORY PRE-BID MEETING November 6, 2026 at 10:00 am in the MAWSS Operations Center Board Room
BID OPENING DATE November 19, 2026
BID CLOSING TIME 10:30 am Central Time
AWARD WILL BE MADE BY Total Cost
CONTRACT PERIOD 1/1/27 through 12/31/27 with two 1-year extension options
MATERIAL PICK-UP AND DELIVERY TO MAWSS Lift Station Facility 1610 Shelton Beach Road Ext or MAWSS treatment plant sites Mobile, AL 36618
ADDITIONAL INFORMATION CONTACT Lane Cook (256) 520-0856 lane.cook@jacobs.com David Stejskal (251) 591-9248 david.stejskal@jacobs.com
APPLICABLE SDP POLICY 17-01

Mobile Area Water and
Sewer System
4725 Moffett Road
Mobile, AL 36618-2246
PO Box 180249
Joyce Sawyer, Buyer II Mobile, AL 36618-0249
(251) 694-3110 Office
jasawyer@mawss.com
INVITATION FOR BID
October 19, 2026
INVITATION FOR BID NUMBER IFB 26-060
NAME OF BID Annual Contract for Submersible Pump Repair
MAWSS Purchasing Dept. Bid Box If sending bids by UPS/Fed Ex, deliver to:
East Visitor Entrance 1610 Shelton Beach Rd. Ext., Mobile, AL 36618
BIDS WILL BE RECEIVED AT
4725 Moffett Road Attn: Purchasing
Mobile, AL 36618 with IFB# marked on envelope
MANDATORY PRE-BID MEETING November 6, 2026 at 10:00 am in the MAWSS Operations Center Board Room
BID OPENING DATE November 19, 2026
BID CLOSING TIME 10:30 am Central Time
AWARD WILL BE MADE BY Total Cost
CONTRACT PERIOD 1/1/27 through 12/31/27 with two 1-year extension options
MAWSS Lift Station Facility
MATERIAL PICK-UP AND DELIVERY TO 1610 Shelton Beach Road Ext or MAWSS treatment plant sites
Mobile, AL 36618
Lane Cook (256) 520-0856 lane.cook@jacobs.com
ADDITIONAL INFORMATION CONTACT
David Stejskal (251) 591-9248 david.stejskal@jacobs.com
APPLICABLE SDP POLICY 17-01
Sealed bids must be in the Purchasing Department no later than the time specified to be considered. Submissions received
after the deadline will not be considered. Envelopes must bear the name of the supplier, company address and the words "IFB
26-060 Submersible Pump Repair" or "IFB 26-060 Submersible Pump Repair NO QUOTE." Facsimile or email bids will not be
accepted.
All bids must be submitted on the attached forms, or your bid will be disqualified. Bidder shall furnish all the information
required by the solicitation. The bidder's name must be typed or printed on the bid sheet and signed by the bidder or
appropriately authorized executive officer of the bidder's company. Bidders must initial any changes or erasures. Bidders
should retain a copy of bids for their records.
Bidders shall acknowledge receipt of all addenda to this solicitation by signing and returning each addendum or by identifying
the addendum number and the date on the bid form. Failure to acknowledge receipt of any addendum by a bidder will result
in rejection of the bid if MAWSS determines that the addendum contains information that materially changes the requirements.
All bids shall be quoted FOB Destination, freight prepaid with no additional charges. Unless otherwise specified in the bid, all
prices will be on a firm-fixed price basis and are not subject to adjustments based on costs incurred. MAWSS reserves the right
to reject any or all bids submitted, to waive any informality in any bid or in the bid process, or to terminate the bid process at
any time, if deemed by MAWSS to be in MAWSS's best interest.
A Purchase Order and this "Invitation for Bid" with "Specifications," "Conditions," "Bid Form," signed by the successful bidder's
authorized representative, and all attached drawings and other documents furnished by MAWSS to the bidders with the
Invitation for Bid in order to illustrate the contract requirements, will constitute a contract for the goods and/or services to be
purchased.
IFB 26-060 Submersible Pump Repair Annual Contract Page 1 of 24

IFB 26-060 SUBMERSIBLE PUMP REPAIR
CONDITIONS
The Board of Water and Sewer Commissioners of the City of Mobile will accept bids for Submersible Pump Repair in our
Purchasing Department Bid Box located at the East Visitor Entrance at 4725 Moffett Road, Mobile, AL. 36618 no later than
10:30 a.m. local time on November 19, 2026. Bids will be opened immediately after bid closing time in the Operations Center
Board room located at the East Visitor Entrance. Award will be by Total Cost. The bidder offers and agrees, if this bid is accepted,
to furnish the items as defined in the specifications for the unit price set opposite each item. Pricing shall be FOB Mobile,
Alabama. All items shall be picked up and delivered to our Lift Station Facility or MAWSS treatment plant sites as needed.
A mandatory Pre-Bid meeting will be held between representatives of Contractor and representatives of MAWSS prior to the
bid opening. The Pre-Bid meeting is scheduled for 10:00 am on November 6, 2026, in the MAWSS Operations Center Board
Room located at 4725 Moffett Rd., Mobile, AL 36618 at the East Visitor Entrance. Please arrive ten (minutes) early to ensure
sufficient time to get signed in.
A Bid Bond in the amount of five percent (5%) of this bid, not to exceed $1,000, is required.
All items provided shall be for commercial use and for the purposes reflected in the contract documents. No bid on closed out
or discontinued item(s) will be accepted. Item(s) that have a determinable shelf life must be disclosed at the time of bid
submittal.
Bidder understands that his/her bid shall be good and may not be withdrawn for a period of sixty (60) calendar days after the
scheduled closing time for receiving bids. MAWSS shall not be committed to the service or purchase of a pre-established
minimum quantity for any one item.
A bidder may not modify its bid after bid opening. Errors in the extension of unit prices stated in a bid or in multiplication,
division, addition or subtraction in a bid may be corrected by the MAWSS Purchasing Buyer prior to award. In such cases, unit
prices shall not be changed.
It is the responsibility of the bidder to determine prior to the bid opening whether any amendment, additions, deletions or
changes of any type have been made to this Invitation for Bid, Conditions, Specifications, Bid Form or any other bid documents.
Bid documents and any amendments made to this bid will be posted on our website at www.mawss.com.
A copy of the SDP (Supplier Diversity Program) policy that applies to this Invitation For Bid can be furnished upon request. It is the
responsibility of the bidder to read and make efforts to meet the goals of this policy. Please contact the Supplier Diversity Department at
supplier.diversity@mawss.com for any questions regarding ths policy. Bidders MUST acknowledge receipt of this policy by submitting the
SDP Policy Acknowledgement and the Subcontracting Plan/Good Faith Effort form with the bid proposal, regardless if using a Diverse
Contractor/Supplier or not. Contractors are required to use Contractors/Suppliers only in the areas for which the Contractors/Suppliers
are certified.
Reporting Requirements, if using a diverse contractor/supplier:
"The Contractor must file a written report with MAWSS's Supplier Diversity Office with a copy delivered to Accounting once a month
documenting the Contractor's continuing compliance with the MAWSS Supplier Diversity Program. This report will list all Diverse
Contractor/Supplier's subcontractors and supplier's currently performing work or providing supplies for the contract."
Invoicing Requirements: MAWSS requires additional information for all work performed and services provided. On the vendor's
invoice for payment should be a detailed listing of work performed, services provided, dates completed, locations involved
with maps highlighting the area, and any other pertinent information needed to verify the work and/or services were
completed in accordance with the bid specs. This additional information can be supplied in the form of detailed invoices,
completed work orders with photos attached, checklists, or any other documents used to track the work performed or services
provided, but details must be included on the actual invoice. A copy of the invoice and these additional details must be sent to
the "ADDITIONAL INFORMATION CONTACT" found on Page 1 of the bid documents, and a copy must be emailed to Accounts
Payable at AcctsPayable@mawss.com.
END OF CONDITIONS
IFB 26-060 Submersible Pump Repair Annual Contract Page 2 of 24

IFB 26-060 SUBMERSIBLE PUMP REPAIR
SCOPE OF WORK
PURPOSE
Mobile Area Water and Sewer System (MAWSS) operates a wastewater collection system, two (2) wastewater
treatment plants, two (2) water treatment plants, and a water distribution system. These operations include the
utilization of various pumps, including wet pit and dry pit submersible pumps (submersible pumps). Through the
course of normal operations, these pumps experience failures and must be removed from service for evaluation
and repair or replacement. This bid document intends to establish an annual contract for the evaluation and repair
of submersible pumps generally of size 11 HP to and including 55 HP (excluding vertical turbine pumps and motors).
MAWSS usually replaces 10 HP or less pumps when they need repair. On occasion, one or more of these smaller
pumps may be repaired under this contract.
This Agreement only applies to the repair of submersible pumps used by MAWSS in submerged applications. The
work herein does not apply to submersible pumps used in dry pit applications. Most MAWSS' submersible pumps
are used in wastewater applications.
The term "pumps" used herein shall mean only submersible pumps and include both the wet end part of the pump
along with the submersible motor and associated components.
PURCHASE ORDERS
As a result of this bid, Purchase Order(s) shall be issued as needed for evaluation and repair of submersible pumps.
A master agreement with subsequent individual orders shall be used. No work shall commence until the purchase
order has been approved.
QUANTITIES
The exact quantity of items to be evaluated or serviced/repaired cannot be quantified. Repair orders will be used
on an "as needed" basis. The quantities listed in the bid cost proposal are estimated only to provide a basis for
preparing and evaluating the bid and should not be construed as representing actual quantities to be purchased.
Purchase quantities may be none, partial, or more than the items/quantities listed herein.
DELIVERY
The goal of this bid is to provide a streamlined and speedy process for submersible pump repair services. The
awarded bidder shall, within eight (8) working days (MAWSS holidays excluded) of being notified by MAWSS of a
pump in need of repair, perform the following:
A. Load and transport the submersible pump from the MAWSS site to their facility
B. Assessment of the condition of the pump.
C. An evaluation of the work necessary to repair the pump
D. A cost estimate including the associated documents as required herein.
Repairs shall be made within ten (10) working days after receiving a Purchase Order and parts.
IFB 26-060 Submersible Pump Repair Annual Contract Page 3 of 24

All pumps requiring repair shall be picked up from the MAWSS Lift Station Facility located at Shelton Beach Road or
one of MAWSS's plants. Once repairs have been completed, the repaired item and all discarded parts from the
repaired item shall be returned to the same location at MAWSS from which it was taken.
Emergency repairs required for urgent requests where the health or safety of the public is at risk shall be completed
within forty-eight (48) hours instead of the ten (10) working days previously mentioned. Failure to communicate or
respond within the time specified for emergency repairs may result in the work being performed by others and /or
termination of this contract.
PRICE
Bidders shall provide bid amounts for the bid unit items listed, which include the repair of pumps and applying
coatings when requested. Price shall include transportation, labor, materials, and testing as defined herein.
CONTRACT TERM
This initial contract term shall be for one year (12 months) commencing from the date of execution by both parties.
RENEWAL
The contract shall be renewable two additional times for a period of one year (12 months) for each renewal if agreed
to by both parties. The Contract provisions and pricing must remain unchanged for the renewal periods. This would
provide a maximum contract time of 3 years (36 months) from the commencement of the date of the contract
award.
TERMINATION
MAWSS reserves the right to terminate this contract at the end of the initial, first, or second 12-month renewal
period without reason. MAWSS reserves the right to terminate this contract at any time upon the Repair Facility's
failure to comply with any provision of this Contract.
EXCLUSIVITY
Although MAWSS intends to use the Repair Facility for most of its pump repairs, MAWSS may use other repair
facilities on occasion if MAWSS determines that doing so is in MAWSS's best interest.
This contract does not give the bidder exclusive rights to repair MAWSS pumps.
WARRANTY
All work, materials, and equipment furnished by the Repair Facility shall be guaranteed and warranted by the
vendor/repair facility as specified in the Technical Specifications.
All materials, equipment, and workmanship furnished by the Repair Facility shall be guaranteed by the Repair
Facility to meet MAWSS required standards identified herein and follow the standards set forth by the pump
manufacturer.
IFB 26-060 Submersible Pump Repair Annual Contract Page 4 of 24

MAWSS REPRESENTATIVE
Jacobs will serve as MAWSS representative for this contract. All formal communications including notification
specified in the contract shall be sent to and received from Jacobs Project Manager Lane Cook
(lane.cook@jacobs.com or 256-520-0856). If Mr. Cook is not available, David Stejskal (david.stejskal@jacobs.com
or 251-591-9248) shall be the back-up contact.
IFB 26-060 Submersible Pump Repair Annual Contract Page 5 of 24

IFB 26-060 SUBMERSIBLE PUMP REPAIR
TECHNICAL SPECIFICATIONS
PART 1 - GENERAL
1.01 SCOPE
A. These Specifications form a part of the Contract documents and shall govern the repair of pumps used in
submerged applications at MAWSS. Repairs include the wet end (hydraulic) and motor of the submersible
pumps. Successful bidder, herein after referred to as Repair Facility, shall be responsible for providing all
services required for the repair, including labor, some materials, equipment, testing, pick-up, and delivery
of equipment.
B. This repair specification intends to achieve a consistent, high-quality diagnosis and timely repair of
submersible pumps. Not all repair situations can be covered in this repair specification. The repair objective
is to restore the submersible pump to its original manufactured condition unless specified otherwise herein.
C. The pumps covered by this annual contract include only the following:
i. Submersible pumps of sizes 11 HP up to 55 HP used at MAWSS in a submerged application.
ii. Submersible pumps of 10 HP and less, if desired by MAWSS. These pumps are generally replaced when
repairs are needed; however, there may be occasions when MAWSS prefers an assessment of such a
pump.
iii. Submersible pumps of sizes larger than 55 HP or other pumps including dry-pit submersibles shall be
considered on a case-by-case basis
1.02 REFERENCE DOCUMENTS
A. The following references are to be used in conjunction with these specifications in their latest editions:
1. VAUGHEN'S Pricing Publishing Co. Inc., Motor & Pump Repair Price Guide
2. UL - UL674 Electric Motors and Generators for use in Hazardous Locations
3. FM 3600 Electric Equipment for Use in Hazardous (Classified) Locations General Requirements
4. FM 3615 Explosionproof Electrical Equipment General Requirements
5. Electrical Apparatus Service Association's (EASA)-AR100-1998 Recommended Practice for the Repair of
Rotating Electrical Apparatus
6. IEEE- Std. 43, Recommended Practice for Testing Insulation Resistance of Rotating Machinery
7. IEEE- Std, 112, IEEE Standard Test Procedure for Polyphase Induction Motors and Generators
8. ISO-Std. 1940-1, Mechanical Vibration- Balance Quality Requirements of Rigid Rotors
9. NEMA- Std. MG-1-2009, Motors and Generators
10. ABMA- ANSI/ABMA Std. 7, Shaft and Housing Fits for Metric Radial ball and Roller Bearings.
11. National Electrical Code (NEC)
12. National Fire Protection Agency (NFPA)
IFB 26-060 Submersible Pump Repair Annual Contract Page 6 of 24

13. ANSI/HI 1.6-2000 Rotodynamic (Centrifugal and Vertical) Pumps for Hydraulic Performance Acceptance
Test
1.03 QUALIFICATIONS
A. Repair Facility must be able to meet all the following qualifications:
1. Repair Facilities must have at least 5 years of experience repairing submersible pumps.
2. Repair Facilities must be located within a 100-mile radius from the MAWSS offices located on 4725
Moffett Road, Mobile, AL 36618.
3. Repair Facility must be accredited by the Electrical Apparatus Service Association (EASA)
4. Repair Facility must have a minimum of two years of experience applying Belzona coatings.
5. Repair Facility must be able to perform explosion-proof repairs and meet requirements for hazardous
locations specified in Section 1.04.
6. Repair Facility must be able to perform repairs on the following submersible pumps. If the repair facility
is not certified to repair the following pumps, then the repair facility shall supply documentation
showing 5 years of experience working on the respective pump types.
a. Flygt
b. KSB
c. Wilo
7. Repair Facility must be able to perform a limited factory test to confirm the pump is operating properly
and within its expected performance curve upon MAWSS request. Repair facility may use a qualified
third-party testing facility if it is not capable of performing these services in-house.
B. The Bidder shall certify in writing that they meet without exception all of the qualifications identified in
this Section 1.03. Said certification shall be provided with the Bid Proposal.
1.04 HAZARDOUS LOCATIONS
A. The majority of submersible pumps that will be sent to the Repair Facility are explosion-proof equipment
from the manufacturer. The Repair Facility shall consider all submersible pumps submitted by MAWSS for
repair as explosion-proof unless specifically identified in writing as non-explosion proof by MAWSS. If the
Repair Facility discovers the equipment is not explosion-proof and MAWSS has not identified it as such, the
Repair Facility must contact MAWSS as soon as the equipment is determined to be non-explosion proof.
When the submersible pump to be repaired was manufactured explosion-proof, the repair shall maintain
the explosion-proof characteristics of the pump.
B. Repair Facility must be certified by Underwriters Laboratories to meet the requirements of UL674
Qualifications of Facilities Engaged in the Repair of Electric Motors and Generators for use in Hazardous
Locations. If a submersible pump has an existing UL tag, the Repair Facility shall apply a new UL tag. If there
is no UL tag on the submersible pump, the Repair Facility shall provide a written certification that the
submersible pump was repaired in strict accordance with UL requirements. This certification must be
provided when the submersible pump is returned to MAWSS. The said written certification shall identify
the date on which the Repair Facility was last certified by UL and the date on which the Repair Facility's UL
Certification expires. Repair Facility must be certified by UL at the time of the bid opening and maintain the
Certification for the duration of the contract. Provide a copy of the UL Certification with the Bid
documents.
IFB 26-060 Submersible Pump Repair Annual Contract Page 7 of 24

C. If Repair Facility is a manufacturer's certified shop and it receives a brand of submersible pump from
MAWSS for which the Repair Facility is a certified representative, the Repair Facility shall repair the pump
to FM Global standards to meet FM3600 and FM 3615 and tag the repaired equipment accordingly.
However, this same Repair Facility may repair brands of pumps that it does not represent as long as the
aforementioned UL requirements are met. Provide FM Certification with the Bid, if the Repair facility is a
submersible pump brand representative of Flygt, KSB, or WILO.
D. A list of certifications shall be provided that enumerates the certifications of the Repair Facility. The list
shall include the dates on which certifications were received and their expiration dates. A copy of each
certification shall be provided, or a written statement detailing the certification and the factory location
that authorized the facility to perform work on their products. These certifications shall be provided with
the Bid.
E. Provide a list of any facility audits conducted by the certifying agencies over the last 5 years, the
frequency of such audits, and any reports that were produced from the facility audits. This information
must be provided with the Bid.
PART 2 - REPAIR
2.01 GENERAL
A. This section provides the steps to be taken during the submersible pump repair process. These steps are
meant to streamline the process and provide guidance during the repair.
2.02 LOGISTICS
A. MAWSS shall notify the Repair Facility when there is a submersible pump requiring repair. MAWSS shall pull
the submersible pump and prepare it for transport. When the pump returns to MAWSS, MAWSS will install
the pump at the time deemed operationally necessary, which may be months after the pump returns to
MAWSS. This is especially the case for returned pumps that will be used as spares.
Timely retrieval, inspection, and repairs of MAWSS pumps are critical to MAWSS operations. A failure to
comply with the time requirements stated herein could result in the termination of this contract by MAWSS.
The Repair Facility shall transport the submersible pump from and return to MAWSS at one of the following
locations:
1. Lift Station Department Facility located at 1610 Shelton Beach Road Ext., Mobile, AL 36618
2. C.C. Williams Wastewater Treatment Plant located at 1600 Yeend St., Mobile, AL 36603
3. Wright Smith Jr. Wastewater Treatment Plant located at 1879 N. Conception Street Rd., Mobile, AL
36610
4. E.M. Stickney Water Treatment Plant located at 4800 Moffett Rd., Mobile, AL 36618
5. H.E. Myers Water Treatment Plant located at 1475 Hubert Pierce Rd. Mobile, Al 36608
B. The Repair Facility shall document the following information, as applicable, when the submersible pump
arrives:
1. Job Number/Estimate Number and MAWSS work order number.
2. Date of pickup and arrival.
3. Location associated with a pump, such as a lift station number or treatment plant location, based on
information provided by MAWSS.
IFB 26-060 Submersible Pump Repair Annual Contract Page 8 of 24

4. Pump make, model, and serial number
5. Motor HP
6. Motor Voltage
7. Any other data plate or pertinent information regarding the identification of the pump.
The above information shall be used to identify the pump in invoices and reports. Once documented, the
repair facility shall provide this information to MAWSS.
2.03 EVALUATION AND ESTIMATE
A. The Repair Facility shall inspect the pump and provide MAWSS with a written Evaluation and Cost Estimate
of the repairs needed for MAWSS approval before any repairs begin. The Evaluation and Estimate shall
include the condition of the pump upon arrival, a brief description of the pump requiring repair, photo
documentation of the pump, a detailed cost estimate, and an itemized list of needed repair parts.
1. The Estimate shall enumerate the pump part descriptions and manufacturer part numbers needed to
make the repairs. The estimate shall include both OEM parts and non-OEM alternative parts (where
applicable) with part delivery dates provided for both options (documentation from the parts supplier
may be requested by MAWSS.)
2. Coatings, lubricants, fasteners, electrical connectors, and other ancillary parts will be furnished by the
Repair Facility and must be included in the total and estimated via industry standard protocols where
Vaughens does not make known. A separate line-item cost for machining hours must also be priced in
the estimate, showing unit cost and number of hours.
3. Repairs shall be completed and returned to MAWSS within ten (10) working days after the date of
receiving parts or purchase order from MAWSS, whichever is furnished last. MAWSS must be notified
upon receiving the parts at the repair facility.
4. Disassembly shall be per procedures provided by the original equipment manufacturer (OEM) if
applicable.
5. The Evaluation and Estimate shall include the following as applicable:
a. Condition of cable entry, glands, body, impeller, impeller coating, volute, wear rings, power and
control cables, bearings, and seals
b. Measurement of insulation resistance
c. Deviations from manufacturer's acceptable tolerances
d. Condition of volute coating substantiated with photos of damaged or missing coating
e. Itemized new parts with description and manufacturer part numbers (both OEM and non-OEM)
required to repair the pump. MAWSS will purchase the parts and provide them to the repair facility.
f. See Section 2.04 below for additional information.
g. Total working days to complete the repair, along with a justification if longer than the time specified
herein after receipt of parts. If additional working days are required beyond those specified herein,
the MAWSS will be notified immediately upon the repair facility's knowledge of the delay.
Documentation shall be provided by the Repair Facility if requested by MAWSS to substantiate
reasons for the delay.
h. Man-hours for labor shall not exceed the normal/customary time allotment as indicated in
Vaughen's Motor and Pump Repair Price Guide (latest edition) for the task performed except for
IFB 26-060 Submersible Pump Repair Annual Contract Page 9 of 24

where tasks that are not denoted within the guide. Man-hours for task not listed shall be identified
as such in the repair cost estimate with a justification provide for the time.
i. Total cost for repair.
j. Options and recommendations for repair/replacement, if any.
k. If machining is required, identify hours and labor cost for machining. If materials are required for
the machine work, itemize the materials required and the machine shop cost. Markup on machine
shop materials must not exceed 12% of the machine shop cost to Repair Facility. Invoices from the
machine shop or the Repair Facility, if they are doing the machining, must be provided with the
pump repair invoice to MAWSS.
6. The original broken parts from the repaired submersible pump shall be returned to MAWSS when the
repaired pump is provided to MAWSS.
B. MAWSS will review the Evaluation and Estimate provided and determine if repairs will proceed. If approved
for repairs, MAWSS will proceed with a Purchase Order (PO) to the Repair Facility authorizing the Facility to
proceed with making the approved repairs. No repairs shall be made if a P.O. has not been issued to the
Repair Facility.
C. If an evaluation and cost estimate is provided to MAWSS and MAWSS chooses not to make the repairs, the
repair facility shall be compensated as follows for the pick-up, evaluation, cost estimate, and return of all
pump parts and components to MAWSS:
Evaluation and Estimate - Submersible Pump $600.00
MAWSS makes no obligation whatsoever to approve repairing all pumps sent for evaluation. Upon receipt
of the evaluation and estimate report, MAWSS will review the report and respond with repair decision
regarding a decision on repairing the pump to the Repair Facility typically within 10 business days. If
MAWSS decides not to repair the pump, the Repair Facility shall return the pump to MAWSS within 5
business days and submit an invoice for the evaluation cost within 20 business days.
2.04 PARTS MARK-UP AND LABOR ESTIMATE
A. Percentage mark-up for any parts that may be furnished by the Repair Facility shall not exceed 12% of part
supplier's invoice to the Repair Facility. Itemized receipts from the parts supplier shall be provided to
MAWSS with the invoice for repairs. At a minimum, receipts shall show the name and address of the parts
vendor, part manufacturer, part description, part number, quantity, and cost of each.
B. All labor necessary to remove and install new parts shall be included in the Evaluation and Estimate.
C. Parts prices and Repair Facility mark-up percentage shall be included in the Evaluation and Estimate
provided to MAWSS.
D. MAWSS reserves the right to audit and inspect the shop for any repairs completed under this annual
contract.
2.05 PUMP EVALUATION AND REPAIR
A. After submersible pump identification information is documented, proceed with photographing the pump
before disassembly, and note the visual condition of the pump as received. Note any damage whatsoever
that is visible on the exterior of the pump, like cracks, broken or missing components, physical damage,
worn/eroded parts, cable damage, coating damage, etc.
IFB 26-060 Submersible Pump Repair Annual Contract Page 10 of 24

This is the opportunity summary page. It provides an overview of this opportunity and a preview of the attached documentation.
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

Follow Uncrewed Aircraft System Marketplace Commercial Solutions Opening Active Contract Opportunity Notice ID

DEPT OF DEFENSE

Bid Due: 3/11/2031

Follow Uncrewed Aircraft System Marketplace Commercial Solutions Opening Active Contract Opportunity Notice ID

DEPT OF DEFENSE

Bid Due: 3/11/2031

Follow U.S. Army Contracting Command - Anniston Army Depot (CCTA-HDA) Organic Industrial Base

DEPT OF DEFENSE

Bid Due: 5/18/2030

Follow Mobile Integrated Launch Capability Active Contract Opportunity Notice ID 26-MDA-12366 Related Notice

DEPT OF DEFENSE

Bid Due: 9/30/2028

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.