6515--575 / Equipment / Sterilization Containers / 575-25-3-1072-0089 (VA-25-00091504)

Location: Federal
Posted: Jul 28, 2025
Due: Aug 4, 2025
Agency: VETERANS AFFAIRS, DEPARTMENT OF
Type of Government: Federal
Category:
  • 65 - Medical, Dental, and Veterinary Equipment and Supplies
Solicitation No: 36C25925Q0634
Publication URL: To access bid details, please log in.
Follow
6515--575 / Equipment / Sterilization Containers / 575-25-3-1072-0089 (VA-25-00091504)
Active
Contract Opportunity
Notice ID
36C25925Q0634
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
NETWORK CONTRACT OFFICE 19 (36C259)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information View Changes
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
  • Updated Published Date: Jul 28, 2025 02:08 pm MDT
  • Original Published Date: Jul 18, 2025 03:09 pm MDT
  • Updated Date Offers Due: Aug 04, 2025 12:00 pm MDT
  • Original Date Offers Due: Aug 04, 2025 12:00 pm MDT
  • Inactive Policy: Manual
  • Updated Inactive Date: Oct 03, 2025
  • Original Inactive Date: Oct 03, 2025
  • Initiative:
    • None
Classification View Changes
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
  • NAICS Code:
    • 339113 - Surgical Appliance and Supplies Manufacturing
  • Place of Performance:
    ,
Description View Changes
The purpose of this amendment is to respond/answer questions regarding solicitation 36C25925Q0634.
The solicitation has Line item 2 as SKF05 and Line item 3 as SKF02 but we believe they should be BSKF05 and BSKF02 respectively.
Yes, these should be BSKF02 and BSKF05, baskets.
I wanted to confirm the postal code for the place of performance (ship to address) and whether it is 81507 or 81501.
81507 is the ship to address zip code.
May I kindly request if you could provide: Manufacturer names and part numbers (if available); Or any technical data sheets, catalog references, or brand-specific equivalents? The line-item codes provided in the RFQ (e.g., SC08FG, SKF05, MAT042) appear to be internal references, and we are unable to cross-reference them without further specification.
These line items are not internal inventory numbers; they are Case brand numbers.
We are not requiring any specific brand, this is an OR EQUAL solicitation. The brands shown in this solicitation are examples.
Since the RFQ references both Aesculap and CASE Medical but only references the CASE Medical part # s in the RFQ, would it be feasible to also add-in the corresponding Aesculap part # s (attached). We ve found that specific part # s provide an inherent advantage. Therefore, requesting that the Aesculap part # s also be referenced within the RFQ.
Please refer to the sample product information below.
https://www.bing.com/search?q=what+is+the+equivalent+aesculap+to+sc08fg+container+case+size&qs=GS&pq=what+is+the+equivalent+aesculap+to+sc08fg+container+case&sc=12-56&cvid=AF642BFCA4C3499CAD04FF1628ED1EBC&FORM=QBRE&sp=1&lq=0
https://casemed.com/index.php/products/containers

Is the QR code required on every container - immediately provides instructions for use as well as data specifications such as size, weight, and product codes and can be accessed from a tracking scanner or any smart phone or tablet.
See the updated list of Salient Characteristics below. Item 5. Please identify how these are provided.
Does the Grand Junction VAMC prefer a sterilization container which is also validated as a bio-hazard transport bin for soiled sets/instruments?
Per the SPS department this feature is not required.
Salient Characteristics:
Must be compatible with sterilization cycles including Prevac, IUSS, Gravity, Steam, and low temp sterilization for STERRAD 100NX machines.
Must have ergonomic handles.
Must have a filter retention plate with audible click or valve to replace filter.
Must have containers that are validated to be stacked during sterilization and storage.
Must have accompanied manufacturer s instructions for use.
Must be compatible with automated washer disinfectors with ability to withstand temperatures of 190 degrees.
Attachments/Links
Contact Information View Changes
Contracting Office Address
  • 6162 S WILLOW DR SUITE 300
  • Greenwood Village , CO 80111
  • USA
Primary Point of Contact
Secondary Point of Contact


History

Related Document

Jul 18, 2025[Combined Synopsis/Solicitation (Original)] 6515--575 / Equipment / Sterilization Containers / 575-25-3-1072-0089 (VA-25-00091504)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...VETERANS AFFAIRS, DEPARTMENT OF Office 242-NETWORK CONTRACT OFFICE 02 (36C242) General Information...-EDGE UD ...

VETERANS AFFAIRS, DEPARTMENT OF

Bid Due: 6/09/2026

..., DEPARTMENT OF Sub-tier VETERANS AFFAIRS, DEPARTMENT OF Office 241-NETWORK CONTRACT OFFICE 01 ...

VETERANS AFFAIRS, DEPARTMENT OF

Bid Due: 6/12/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.