BACKUP GENERATOR SERVICE
| Location: |
Federal |
| Posted: |
May 13, 2025 |
| Due: |
May 16, 2025 |
| Agency: |
INTERIOR, DEPARTMENT OF THE |
| Type of Government: |
Federal |
| Category: |
- J - Maintenance, Repair, and Rebuilding of Equipment
|
| Solicitation No: |
140R1725Q0053 |
| Publication URL: |
To access bid details, please log in. |
J--BACKUP GENERATOR SERVICE
Active
Contract Opportunity
Department/Ind. Agency
INTERIOR, DEPARTMENT OF THE
Sub-tier
BUREAU OF RECLAMATION
Office
GRAND COULEE POWER OFFICE
Looking for contract opportunity help?
General Information
-
Contract Opportunity Type: Sources Sought (Original)
-
Original Published Date: May 13, 2025 07:11 am PDT
-
Original Response Date: May 16, 2025 05:00 pm PDT
-
Inactive Policy: 15 days after response date
-
Original Inactive Date:
May 31, 2025
-
Initiative:
Classification
-
Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
-
Product Service Code: J061 - MAINT/REPAIR/REBUILD OF EQUIPMENT- ELECTRIC WIRE AND POWER DISTRIBUTION EQUIPMENT
-
NAICS Code:
-
811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
-
Place of Performance:
Description
This Sources Sought notice is for informational and planning purposes only. It does not constitute a solicitation and is not to be considered as a commitment by the Government. All firms responding to this Sources Sought notice are advised that their response to this notice is not a request that will be considered for contract award. The information from this market research is for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research, and the Government will not entertain question concerning this market research.
The intent of this notice is to determine the availability of business to provide testing and preventive maintenance on ten (10) Emergency Generator located at Grand Coulee Dam in Washington State.
The requirement is to conduct preventive maintenance and to test and operate ten emergency generators as follows: the emergency generators shall be load tested with a Contractor-furnished load bank at a minimum of 30 percent of generator rated capacity for 30 minutes monthly and once every 3 years at a minimum of 80 percent of generator rated capacity for 4 hours. The ten generators are listed below.
- Perkins - 45KW located at Feeder Canal Check Structure with manual transfer switch.
- Aptech - 200KW located Left Power House (LPH) Tailrace.
- Aptech - 125KW located 230 YD (portable - trailer mounted).
- Aptech - 200KW located at LPH No. 2 - Control Bay with manual transfer switch.
- Aptech - 200KW located at Industrial Area (IA)- Mechanical Repair Shop (MRS)
- Caterpillar - 350KW location Pumping Generating Plant (PGP) No. 1 -Transformer Deck.
- Generac - 30KW location 911 Tower site w/ Auto Transfer Switch.
- Magnum - 186kW located at Industrial Area (IA) - Mechanical Repair Shop (MRS) (portable - trailer mounted)
- Cummins- 80kW located at Security Building
- Caterpillar - C15, 500kw, with CAT 800 Auto Transfer Switch - located at new Fire Station.
Potential offers having technical capabilities necessary to meet the needs of the described requirement are invited to provide a capabilities statement via email. The capability statement must include the following:
1) Company name and point of contact information.
2) UEI or Cage Code Number
3) Business size whether large or small. If small please provide socio-economic status such as 8(A), HUBZONE, SDVOSB, ETC if applicable.
4) Brief explanation of the services and capabilities your company provides.
Responses are due no later than 1700, Pacific Time, Friday, May 16, 2025, and shall be electronically submitted to Terry Mest at tmest@usbr.gov. All responses will be used to determine the appropriate acquisition strategy for a potential future acquisition. Response is strictly voluntary; no reimbursement will be made for any cost associated with providing information in response to this synopsis or any follow-up information requests.
Attachments/Links
Contact Information
Contracting Office Address
-
PO BOX 620
-
GRAND COULEE , WA 99133
-
USA
Primary Point of Contact
-
Mest, Terry
-
tmest@usbr.gov
-
Phone Number
5096339327
-
Fax Number
5096339175
Secondary Point of Contact
History
-
May 13, 2025 07:11 am PDTSources Sought (Original)
Daily notification on new contract opportunities
With GovernmentContracts, you can:
- Find more opportunities and win more business
- Receive daily alerts for all new bid opportunities
- Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
See also
...Follow PRESSURE SWITCH Active Contract Opportunity Notice ID N0010426QAB73 Related Notice...|JOSHUA.D.MARTIN76.CIV@US.NAVY.MIL| PAYMENT BY ...
DEPT OF DEFENSE
Bid Due: 6/26/2026
...transfer switch and two (2) fusible safety disconnect switches, two (2) precast pull ...
ENERGY, DEPARTMENT OF
Bid Due: 6/29/2026
...transfer switch, backup generator, and main AC switchboard. c. Furnish and install over ...
ENERGY, DEPARTMENT OF
Bid Due: 7/31/2026
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.