RFQ 26-511 Airport Park Breakroom & Ceiling Renovation

Location: Louisiana
Posted: May 4, 2026
Due: May 19, 2026
Agency: City of Shreveport
Type of Government: State & Local
Category:
  • Z - Maintenance, Repair or Alteration of Real Property
Publication URL: To access bid details, please log in.


RFQ 26-511 Airport Park Breakroom & Ceiling Renovation
It shall be the responder's responsibility to make inquiry as to the addenda issued.

Attachment Preview

SHREVEPORT PUBLIC ASSEMBLY & RECREATION
AIRPORT PARK COMMUNITY CENTER
KITCHEN & LOBBY CEILING RENOVATIONS
6500 KENNEDY DRIVE
SHREVEPORT, LOUISIANA 71109
PROJECT ASSOCIATES
ARCHITECT
RUSSELL G. DeLANCY, AIA, ARCHITECT
505 TRAVIS STREET, SUITE 560
SHREVEPORT, LOUISIANA 71101
(318) 673-7868
PROJECT LOCATION MAP
SHREVEPORT
REGIONAL
AIRPORT
PROJECT SITE
AIRPORT PARK COMMUNITY CENTER
6500 KENNEDY DRIVE
SHREVEPORT, LOUISIANA
NORTH
HOLLYWOOD AVE.
W. 70TH STREET
CITY OF SHREVEPORT
CITY ADMINISTRATION
CITY OF SHREVEPORT
TOM ARCENEAUX - MAYOR
TOM DARK - CHIEF ADMINISTRATIVE OFFICER
CITY COUNCIL
TABATHA H. TAYLOR - DISTRICT A
GARY BROOKS - DISTRICT B
JIM TALIAFERRO - DISTRICT C
GRAYSON BOUCHER - DISTRICT D
DR. ALAN JACKSON, JR. - DISTRICT E
JAMES GREEN - DISTRICT F
URSULA BOWMAN - DISTRICT G
SHREVEPORT PUBLIC ASSEMBLY & RECREATION
SHELLY RAGLE - DIRECTOR
DETAIL NUMBER
GENERAL NOTES
1. ALL WORK SHALL CONFORM WITH THE FOLLOWING CODES:
- 2023 LOUISIANA STATE UNIFORM CONSTRUCTION CODE
- 2021 INTERNATIONAL BUILDING CODE
- 2021 INTERNATIONAL EXISTING BUILDING CODE
- 2021 INTERNATIONAL MECHANICAL CODE
- 2021 INTERNATIONAL PLUMBING CODE
- 2021 INTERNATIONAL FUEL GAS CODE
- 2015 NFPA 101 LIFE SAFETY CODE REQUIREMENTS
- 2010 ADA-ABA ACCESSIBLITY GUIDELINES
- 2020 NATIONAL ELECTRIC CODE
2. ALL WORK SHALL CONFORM TO ALL OTHER PERTINENT CODES, REGULATIONS, LAWS AND
ORDINANCES AS REQUIRED BY THE CITY OF SHREVEPORT AND THE STATE OF LOUISIANA.
3. ALL PLAN DIMENSIONS INDICATED ARE TO COLUMN CENTERLINE, TO FACE OF CONCRETE,
FACE OF PARTITION, OR TO FACE OF MASONRY UNLESS NOTED OTHERWISE.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL DIMENSIONS IN THE FIELD AND, IN
THE EVENT OF DISCREPANCY, REPORTING SUCH DISCREPANCY TO THE ARCHITECT, BEFORE
COMMENCING WORK.
5. TEMPORARY BARRICADES FOR THE PROTECTION OF PEDESTRIANS SHALL BE PROVIDED AS
REQUIRED BY THE CITY OF SHREVEPORT AND/OR THE STATE OF LOUISIANA.
6. DURING CONSTRUCTION PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF 2A-10B:C
WITHIN A 75 FOOT TRAVEL DISTANCE OF ALL PORTIONS OF THE BUILDING ON EACH FLOOR.
LOCATE AS DIRECTED BY THE LOUISIANA STATE FIRE MARSHAL.
7. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, SPECIAL
KNOWLEDGE OR EFFORT.
DRAWING SYMBOLS
ROOM
XXX
ROOM NAME & ROOM NUMBER
X/X.XX
X/X.XX
X
XX
EXTERIOR ELEVATION MARK
SHEET NUMBER
INTERIOR ELEVATION MARK
PARTITION TYPE
WINDOW FRAME TYPE
DETAIL NUMBER
X/X.XX
DETAIL NUMBER
X
X.XX
X
X.XX
XX
DOOR NUMBER
X
X/X.XX
SHEET NUMBER
DETAIL SECTION MARK
ENLARGED PLAN DETAIL
BUILDING SECTION MARK
SHEET NUMBER
WALL SECTION MARK
PLAN KEY NOTE
ABBREVIATIONS
@
A.F.F.
ALUM.
ANOD.
APPROX.
BD.
BLDG.
BLK.
BM.
C
C.B.
C.I.P.
C.J.
C.L.
CLR.
CMU
COL.
CONC.
DBL.
DET.
DIA.
DIM.
DN.
AP
D.S.P.
DWGS.
EA.
E.F.D.
ELEC.
EQ.
EWC
EXIST.
EXT.
F.D.C.
F.D.H.C.
FEC
FIN.FL.
F.H.C.
FIN.
F.L.
FLR.
F.O.C.
F.O.S.
F.O.M.
GA.
GALV.
GEN.
G.I.
GYP.
HT.
H.B.
H.M.
H.P.
AT
ABOVE FINISHED FLOOR
ALUMINUM
ANODIZED
APPROXIMATELY
BOARD
BUILDING
BLOCK
BEAM
COMPACT STALL
CATCH BASIN
CAST IN PLACE
CONTROL JOINT
CENTER LINE
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
DOUBLE
DETAIL
DIAMETER
DIMENSION
DOWN
ACCESSIBLE PARKING
DRY STANDPIPE
DRAWINGS
EACH
EMERGENCY FLOOR DRAIN
ELECTRICAL
EQUAL
ELECTRIC WATER COOLER
EXISTING
EXTERIOR
FIRE DEPT. CONNECTION (INPUT)
FIRE DEPT. HOSE CONNECTION
(2-1/2" & 1-1/2" OUTLETS)
FIRE EXTINGUISHER CABINET
FINISH FLOOR
FIRE HOSE CABINET
FINISHED
FLOW LINE
FLOOR
FACE OF CONCRETE
FACE OF STUD
FACE OF MASONRY
GAUGE
GALVANIZED
GENERAL
GALVANIZED IRON
GYPSUM
HEIGHT
HOSE BIBB
HOLLOW METAL
HIGHPOINT
HORIZ.
I.D.
INT.
JAN.
LAV.
LLH.
LLV.
MANUF.
MAS.
MAX.
MECH.
M.H.
MIN.
MISC.
M.O.
MTL.
N.I.C.
O.C.
O.D.
OPG.
P.L.
P.P.
PR.
R.D.
REINF.
REQ'D
R.O.
S
SCHED.
S.D.
SECT.
SHT.
SIM.
SP
SPECS.
S/S
STD.
STL.
STRUCT.
T.C.
TEL.
T.O.C.
T.O.S.
T.S.
T.W.
TYP.
U.N.O.
W/
W/O
W.C.
W.S.P.
W.W.M.
W.P.
HORIZONTAL
INSIDE DIAMETER
INTERIOR
JANITOR'S CLOSET
LAVATORY
LONG LEG HORIZONTAL
LONG LEG VERTICAL
MANUFACTURER
MASONRY
MAXIMUM
MECHANICAL
MANHOLE
MINIMUM
MISCELLANEOUS
MASONRY OPENING
METAL
NOT IN CONTRACT
ON CENTER
OUTSIDE DIAMETER
OPENING
PROPERTY LINE
POWER POLE
PERIMETER
ROOF DRAIN
REINFORCED (ING)
REQUIRED
ROUGH OPENING
STALL WIDTH
SCHEDULE
STORM DRAIN
SECTION
SHEET
SIMILAR
SPRINKLER RISER
SPECIFICATIONS
SERVICE SINK
STANDARD
STEEL
STRUCTURAL
TOP OF CURB
TELEPHONE
TOP OF CONCRETE
TOP OF STEEL
TOP OF SPANDREL
TOP OF WALK, WALL
TYPICAL
UNLESS NOTED OTHERWISE
WITH
WITHOUT
WATER CLOSET
WET STANDPIPE
WELDED WIRE MESH
WATERPROOF
DRAWING INDEX
COVER SHEET
A1.01 DEMOLITION PLAN
A2.01 FLOOR PLAN
A2.02 REFLECTED CEILING PLAN
A3.01 INTERIOR ELEVATIONS / MILLWORK SECTIONS
APRIL 21, 2026
CITY OF SHREVEPORT
REVISIONS:
GENERAL DEMOLITION NOTES
1. ALL DEMOLITION WORK WILL BE PERFORMED IN A SAFE AND ORDERLY MANNER.
2. ALL DEBRIS SHALL BE PROPERLY AND LEGALLY HAULED AND DISPOSED.
3. DEMOLITION CONTRACTOR WILL BE RESPONSIBLE FOR ALL FEES, APPLICATIONS
AND LICENSES ASSOCIATED WITH DEMOLITION AND DISPOSAL.
4. OWNER SHALL MAINTAIN FIRST RIGHT OF REFUSAL ON ALL REMOVED ITEMS.
5. ALL DEMOLITION WORK SHALL BE COORDINATED WITH NEW WORK AND SHALL
INCLUDE ALL NECESSARY PENETRATIONS IN WALLS AND FLOOR SLABS ASSOCIATED
WITH NEW SCOPE.
6. DURING DEMOLITION ACTIVITY, EXTREME CARE SHALL BE TAKE NOT TO DAMAGE
EXISTING FEATURES THAT ARE TO REMAIN INPLACE. ANY DAMAGE TO EXISTING
FEATURES INTENED TO REMAIN SHALL BE REPAIRED/REPLACED TO THE SATISFACTION
OF THE OWNER AT THE CONTRACTOR'S EXPENSE.
7. ALL DEMOLITION ACTIVITY SHALL BE COORDINATED AND SCHEDULED WITH THE
BUILDING OWNER.
8. ALL DOORS AND FRAMES IDENTIFIED TO BE REMOVED SHALL BE SALVAGED FOR REUSE.
THIS SCOPE SHALL ALSO INCLUDE THE SALVAGE OF ALL HARDWARE.
9. CONTRACTOR SHOULD BE AWARE OF LOAD BEARING WALL DURING DEMOLITION
ACTIVITIES. PROPER BRACING SHOULD BE USED TO INSURE STRUCTURAL INTEGRITY.
DEMOLITION PLAN NOTES
D1 REMOVE EXISTING CEILING PANELS AND GRID. PREP AREA TO RECEIVE NEW GRID AND ACOUSTIC CEILING PANELS.
D2 REMOVE VERTICAL PORTION OF ACOUSTIC CEILING PANELS. PREP AREA TO CONSTRUCT NEW DRYWALL BULKHEAD.
D3 REMOVE EXISTING LIGHT FIXTURES SHOWN DASHED. PREP TO RECEIVE NEW FIXTURE. SEE REFLECTED CEILING PLAN.
D4 REMOVE EXISTING HVAC SUPPLY AIR GRILLS SHOWN DASHED. PREP DUCT TO RECEIVE NEW GRILL.
D5 REMOVE EXISTING HVAC RETURN AIR FILTER GRILLS SHOWN DASHED. PREP DUCT TO RECEIVE NEW RETURN AIR FILTER GRILL.
D6 SALVAGE EXISTING CEILING MOUNTED SPEAKERS FOR REINSTALLATION.
D7 EXISTING SLOT DIFFUSER TO REMAIN. CLEAN.
D8 REMOVE EXISTING EXIT LIGHT SHOWN DASHED. PREP TO RECEIVE NEW EXIT FIXTURE.
D9 REMOVE EXISTING MILLWORK.
EXISTING VENT HOOD TO REMAIN. PROTECT FROM DEMOLITION SCOPE.
REMOVE EXISTING STAINLESS STEEL SINK & FAUCET. PREP PLUMBING TO RECEIVE NEW SCHEDULED SINK & FAUCET.
REMOVE EXISTING ELECTRIC RANGE.
PARTITION LEGEND
EXISTING PARTITION TO REMAIN
EXISTING PARTITION TO BE REMOVED
NEW PARTITION (SHOWN ON FLOOR PLAN)
DEMOLITION PLAN
SCALE: 1/8" = 1'-0"
APRIL 21, 2026
2
2
GAMES
1
103
1
CORRIDOR
2
102
1
LOBBY
101
2
6
GALLEY
104
3
7
4
2/A3.01 9
8
5
CITY OF SHREVEPORT
REVISIONS:
FLOOR PLAN GENERAL NOTES
1. ONLY AREAS THAT HAVE RECEIVED ROOM NAMES & NUMBERS ARE IN THE SCOPE OF WORK. ALL OTHER AREAS ARE N.I.C.
2. REFER TO SHEET A1.01 FOR DEMOLITION SCOPE.
3. REFER TO SHEET A2.02 FOR REFLECTED CEILING PLAN.
PARTITION LEGEND
EXISTING PARTITION TO REMAIN
EXISTING PARTITION TO BE REMOVED (SHOWN OF DEMOLITION PLAN)
NEW PARTITION NON-FIRE RATED
FLOOR PLAN KEY NOTES
PREP AREA TO RECEIVE NEW ACOUSTIC LAY-IN CEILING PANELS AND GRID. SEE REFLECTED CEILING PLAN FOR SCOPE.
DRYWALL BULKHEAD SHOWN DASHED. SEE REFLECTED CEILING PLAN.
EXISTING ICE MACHINE TO REMAIN. REMOVE FROM KITCHEN AREA AND REINSTALL AT COMPLETION OF WORK.
NEW REFRIGERATOR EQUAL TO GE MODEL GTS22KYNRFS. VERIFY POWER.
NEW KITCHEN SINK EQUAL TO ELKAY STAINLESS STEEL SINK MODEL LGR4322C. PROVIDE WITH DRAINS AND FAUCET SET
EQUAL TO ELKAY LK3001CR. PROVIDE ALL NECESSARY PLUMBING WORK.
EXISTING VENT HOOD TO REMAIN IN PLACE.
NEW ELECTRIC SLIDE-IN RANGE EQUAL TO GE MODEL GR5500PVSS. VERIFY POWER.
NEW MILLWORK. PAINTED FRONTS W/ PLASTIC LAMINATE TOP & FULL BACKSPLASH.
PROVIDE COOKING RESTRICTION SIGNAGE IN BREAK ROOM. SEE 12/A3.01
GENERAL FINISH NOTES
1. NEW DRYWALL BULKHEADS SHALL HAVE AN ORANGE PEEL TEXTURE, PAINTED TO MATCH THE ADJACENT EXISTING WALL.
2. NEW CEILING PANEL SHALL EQUAL TO ARMSTRONG SCHOOL ZONE FINE FISSURED #1713, 24" X 24" SQUARE EDGE. COLOR: WHITE.
3. NEW CEILING GRID SHALL EQUAL TO ARMSTRONG PRELUDE XL 15/16" EXPOSED TEE GRID SYSTEM. COLOR: WHITE.
4. THE NEW MILLWORK FRONTS, DOORS AND DRAWERS ARE TO BE PAINTED SEMI-GLOSS, COLOR TO BE SELECTED BY OWNER.
5. THE NEW MILLWORK COUNTER TOP & BACKSPLASH SHALL BE PLASTIC LAMINATE EQUAL TO WILSONART. COLOR AND TEXTURE TO BE SELECTED BY OWNER.
FLOOR PLAN
SCALE: 1/8" = 1'-0"
APRIL 21, 2026
C1
C2
C8
C4
8"
C3
6"
C5
C3
C3 C5
C4
C7
C6
C7
CITY OF SHREVEPORT
REVISIONS:
CEILING LEGEND
NEW 2 X 4 LED LAY-IN LIGHT FIXTURE EQUAL TO
LITHONIA LIGHTING CPX LED PANEL, 4000K, PRISMATIC A12 LENS
NEW 2 X 4 LED LAY-IN LIGHT FIXTURE EQUAL TO
LITHONIA LIGHTING CPX LED PANEL, 4000K, PRISMATIC A12 LENS, 90 MINUTE EMERGENCY BATTERY PACK
NEW 2 X 2 LED LAY-IN LIGHT FIXTURE EQUAL TO
LITHONIA LIGHTING CPX LED PANEL, 4000K, PRISMATIC A12 LENS
NEW 2 X 2 LED LAY-IN LIGHT FIXTURE EQUAL TO
LITHONIA LIGHTING CPX LED PANEL, 4000K, PRISMATIC A12 LENS, 90 MINUTE EMERGENCY BATTERY PACK.
NEW EXIT LIGHT EQUAL TO LITHONIA LIGHTING, LQM, RED LETTERS, WHITE HOUSING, BATTERY BACK-UP.
REINSTALLED EXISTING SPEAKER. CLEAN SPEAKER BEFORE REINSTALLATION.
NEW 24 X 24 SUPPLY AIR CEILING DIFFUSER EQUAL TO TITUS TMS, FULL FACE LAY-IN MOUNT
NEW 24 X 24 RETURN AIR CEILING FILTER GRILL EQUAL TO TITUS 350RF, LAY-IN T BAR MOUNT, 1" FILTER.
REINSTALLED EXISTING SLOT DIFFUSER. CLEAN DIFFURSER BEFORE REINSTALLATION.
C2
C1
GENERAL CEILING NOTES
1. WORK IS ONLY SCHEDULED IN ROOMS THAT HAVE RECIEVED ROOM NAMES AND NUMBERS ON THE FLOOR PLAN. ALL OTHER AREAS ARE N.I.C.
2. PROVIDE NEW CEILING GRID COMPATIBLE WITH SCHEDULED CEILING PANELS. COLOR: WHITE.
3. COORDINATE ALL OTHER TRADES WITH CEILING WORK TO MINIMIZE DAMAGING EXPOSURE TO OTHER WORK.
4. WHERE APPLICABLE, SUPPORT LIGHT FIXTURE WITH HANGER WIRE AT EACH CORNER.
5. PROVIDE 1 BOX OF ATTIC STOCK OF EACH TYPE OF CEILING PANEL.
7. INSTALL NEW SUSPENDED CEILING AT THE ORIGINAL CEILING HEIGHT. FIELD VERIFY.
REFLECTED CEILING PLAN NOTES
NEW CEILING INSTALLED AT 14'-0"
NEW CEILING INSTALLED AT 10'-0"
NEW CEILING INSTALLED AT 8'-0"
NEW HVAC SUPPLY REGISTER. PROVIDE ALL NECESSARY DUCT WORK FOR PROPER INSTALLATION.
NEW LIGHT FIXTURE. PROVIDE ALL NECESSARY WIRING AND SUPPORTS FOR PROPER INSTALLATION.
EXISTING VENT HOOD TO REMAIN. CLEAN.
NEW DRYWALL FURR-DOWN.
NEW HVAC RETURN AIR GRILL. PROVIDE ALL NECESSARY DUCT WORK FOR PROPER INSTALLATION.
REFLECTED CEILING PLAN
SCALE: 1/8" = 1'-0"
APRIL 21, 2026
1'-7 1/2"
7/A3.10
8'-2"
4'-0"
EXISTING VENT HOOD TO REMAIN
1'-2"
2'-6 1/2"
DRYWALL FURRDOWN
5/A3.01
COOKING RESTRICTION
SIGNAGE
SEE 12/A3.01
1'-2"
9'-8"
3'-2 1/2"
3'-3"
7/A3.01
3'-2 1/2"
1'-2"
DRYWALL FURRDOWN
1'-2"
2'-4"
7/A3.01
8'-2"
5'-10"
8/A3.01
DRYWALL FURRDOWN
5/A3.01
4/A3.01
STAINLESS STEEL SINK
5/A3.01
CITY OF SHREVEPORT
REVISIONS:
2'-4 1/2"
2'-6"
NEW WALL BASE
EXISTING DOOR & FRAME
INTERIOR ELEVATION
SCALE: 1/2" = 1'-0"
2'-0"
PLAS LAM CLAD
3/4" WATER RESISTANT PLYWOOD COUNTER TOP
& SPLASH
SCHEDULED SINK
2'-5 1/2"
CABINET PULLS
APPLIANCE BY OWNER
FULL HEIGHT BACK SPLASH
2'-0"
PLAS LAM CLAD
3/4" MDF COUNTER TOP & SPLASH
FULL HEIGHT BACK SPLASH
8'-0"
ADJUSTABLE SHELF
INTERIOR ELEVATION
SCALE: 1/2" = 1'-0"
2'-0"
PLAS LAM CLAD
3/4" MDF COUNTER TOP & SPLASH
PAINTED
1/4" MDF BACK
PAINTED
3/4" MDF BOTTOM
3/4"
FALSE DRAWER
FRONT
PAINTED
3/4" MDF DOOR
1/2" DRAWER BOX
W/ 1/4" PLYWOOD BOTTOM
PAINTED
1/4" MDF BACK
PAINTED
3/4" MDF ADJ SHELF
PAINTED
3/4" MDF BOTTOM
3/4"
PAINTED
3/4" MDF DOOR
COORDINATE ELECTRICAL
REQUIREMENTS
SCHEDULED APPLIANCE
3"
3"
USE WATER RESISTANT PLYWOOD
AT SINK COUNTER TOP
MILLWORK SECTION
SCALE: 1 1/2" = 1'-0"
MILLWORK SECTION
SCALE: 1 1/2" = 1'-0"
MILLWORK SECTION
SCALE: 1 1/2" = 1'-0"
1'-6"
FULL HEIGHT BACK SPLASH
5'-10"
APPLIANCE BY OWNER
INTERIOR ELEVATION
SCALE: 1/2" = 1'-0"
NEW WALL BASE
EXISTING ICE MAKER
EXISTING DOOR & FRAME
DRYWALL FURRDOWN
PAINTED
1/4" MDF BACK ON
1X WOOD CLEATS
PAINTED
3/4" MDF DOOR
PAINTED
INTERIOR
1'-2"
PAINTED
3/4" MDF ADJ SHELVES
DRYWALL FURRDOWN
PAINTED
3/4" MDF DOOR
PAINTED
1/4" MDF BACK ON
1X WOOD CLEATS
PAINTED
3/4" MDF ADJ SHELVES
PAINTED
INTERIOR
1'-2"
SCHEDULED APPLIANCE
PAINTED
1/4" MDF BACK ON
1X WOOD CLEATS
PAINTED
3/4" MDF DOOR
PAINTED
INTERIOR
1'-2"
VENT HOOD
MILLWORK SECTION
SCALE: 1 1/2" = 1'-0"
MILLWORK SECTION
SCALE: 1 1/2" = 1'-0"
MILLWORK SECTION
SCALE: 1 1/2" = 1'-0"
SCHEDULED ACOUSTIC CEILING
WOOD STUD FRAMING
SECURED TO STRUCTURE
2X HEADER
4 3/4"
ALIGN EDGE ANGLE TRIM
WITH DRYWALL
SCHEDULED ACOUSTIC CEILING
CEILING DETAIL
SCALE: 1 1/2" = 1'-0"
SCHEDULED ACOUSTIC CEILING
WOOD STUD FRAMING
2X HEADER
4 3/4"
ALIGN EDGE ANGLE TRIM
WITH DRYWALL
LINE OF EXISTING PARTITION
CEILING DETAIL
SCALE: 1 1/2" = 1'-0"
SIGNAGE MUST DISPLAY:
RAISED CHARACTER VERBAL
DESCRIPTION
PROVIDE SIGNAGE W/ LIGHT COLORED
CHARACTERS/TEXT & DARK BACKGROUND
ARCHITECT TO SELECT COLORS
9"
BY ORDER OF THE
STATE FIRE MARSHAL
COOKING SHALL NOT
PRODUCE ANY
GREASE LADEN VAPORS
SIGNAGE
SCALE: 3" = 1'-0"
APRIL 21, 2026
This is the opportunity summary page. It provides an overview of this opportunity and a preview of the attached documentation.
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.