Dual Chamber Aerospace Heat Treat Furnace

Location: Georgia
Posted: Nov 25, 2024
Due: Nov 25, 2024
Agency: DEPT OF DEFENSE
Type of Government: Federal
Category:
  • 44 - Furnace, Steam Plant, and Drying Equip, Nuclear Reactors
Solicitation No: L5WC03
Publication URL: To access bid details, please log in.
Follow
Dual Chamber Aerospace Heat Treat Furnace
Active
Contract Opportunity
Notice ID
L5WC03
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE AIR FORCE
Major Command
AIR FORCE MATERIEL COMMAND
Sub Command
AIR FORCE SUSTAINMENT CENTER
Office
FA8571 MAINT CONTRACTING AFSC PZIM
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • Original Published Date: Nov 25, 2024 07:12 am EST
  • Original Response Date: Nov 25, 2024 08:00 am EST
  • Inactive Policy: Manual
  • Original Inactive Date: Dec 23, 2024
  • Initiative:
    • None
Classification
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: 4430 - INDUSTRIAL FURNACES, KILNS, LEHRS, AND OVENS
  • NAICS Code:
    • 333414 - Heating Equipment (except Warm Air Furnaces) Manufacturing
  • Place of Performance:
    Warner Robins , GA 31098
    USA
Description

Dual Chamber Aerospace Heat Treat furnace for processing aluminum, PH stainless, titanium, ferrous alloys.



- Meets AMS2750, TO 1-1A-9



- Boeing 5621 Pyrometry



- NADCAP Non-vacuum atmospheric pressure chamber certified to post process Additive Manufactured parts



- Roll away quench tank w/dual baths: water & oil quench Certified Temperature Uniformity



- Survey Work Volume: Lower Radiant Chamber 2,000°F 12“W x 12“H x 36“Deep Meets Class 3, +/- 15°F from 1,200°F to 2,000°F



- Gas Tight Chamber w/gas flow control Upper Convection Chamber 1200°F 18“W x 12“H x 48“Deep Meets Class 1, +/- 5°F from 200°F to 1,200°F



- Rapid cooling capability - 1,000°F to 350°F in > 30 mins


Attachments/Links
Contact Information
Contracting Office Address
  • CP 478 926 7509 235 PERRY ST BLDG 255
  • ROBINS AFB , GA 31098-1672
  • USA
Primary Point of Contact
Secondary Point of Contact
History
  • Nov 25, 2024 07:12 am ESTSources Sought (Original)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL
* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.