Amendment 0002
The purpose of Amendment 0002 is to incorporate the following into Solicitation W912DW25BA013, for project entitled, “Repair Ghost DFAC - Building 3757 (CE0879)” on Joint Base Lewis-McChord (JBLM), Washington:
Section 1.3. Area Description; added the following paragraph:
Section 1.3.3.1., Paragraph h. Roofing and Envelope, added paragraphs 5 & 6:
Section 1.3.3.1., Paragraph i. Civil, added paragraph 5:
Section 1.3.3.1., Paragraph j. Cold Storage Requirements, the following verbiage was added:
j. Cold Storage Requirements: Contractor to provide (2) dual-temperature cold storage containers for the duration of construction.
(1) Containers should be standard 10 ft walk-in containers with capacity around 400-500 cubic feet each. Approximate external dimensions will be 10 ft (length) x 8 ft (width) x 8.5 ft (height). The term “container” is not limited to connex-style refrigerated containers. Both smooth-sided outdoor walk-in cooler/freezer units and refrigerated container units are acceptable, provided they meet all requirements herein. Containers must be suitable for outdoor placement and delivered as complete, plug-and-play cold storage units. Containers shall include shelving adequate for safe storage and access.
(2) Containers shall be dual-temperature storage capable of refrigeration and freezing in separate compartments OR one dedicated refrigeration container and one dedicated freezer container. Refrigeration mode shall be able to maintain approximate temperatures of +35°F to +45°F and Freezer Mode shall be able to maintain temperatures of 0°F to -10°F.
(5) The containers will be actively used by the customer during construction. The Contractor shall maintain the units in fully operational condition throughout the duration of the project. At project completion, the Contractor shall disconnect the units, restore all disturbed building electrical connections to their prior condition, and remove the containers from the site.
Section 8.1. Work Condition; added the following paragraph:
2. Attachment 9 – Building Envelope Report has been added to the list of attachments.
Note to Bidders: The due date for receipt of bids in response to this solicitation remains unchanged and is as stated on the original SF1442.
All other terms and conditions of this Solicitation remain unchanged.
NOTICE TO BIDDERS: Bidders must acknowledge receipt of this amendment, and any previous amendments, by number and date on the Standard Form 1442, Back, Block 19.
//////////BREAK//////////
Amendment 0001
The purpose of Amendment 0001 is to incorporate the following into Solicitation W912DW25BA013, for project entitled, “Repair Ghost DFAC - Building 3757 (CE0879)” on Joint Base Lewis-McChord (JBLM), Washington:
A completed bid includes:
-Fully executed Form 1442-with amendments acknowledged
-Bid Bond
-Fully completed Bid Schedule
TO:
A completed bid includes:
-Fully executed Form 1442-with amendments acknowledged
-Bid Bond
-Fully completed CLIN Schedule from Section 00 10 00 of this solicitation
Note to Bidders: The due date for receipt of bids in response to this solicitation remains unchanged and is as stated on the original SF1442.
All other terms and conditions of this Solicitation remain unchanged.
NOTICE TO BIDDERS: Bidders must acknowledge receipt of this amendment, and any previous amendments, by number and date on the Standard Form 1442, Back, Block 19.
//////////BREAK//////////
This solicitation (W912DW25B17HG) is an Invitation for Bid (IFB) for the project entitled, Repair Ghost DFAC (Building 3757) on Joint Base Lew is-McChord (JBLM), Washington. The Contractor shall furnish all labor, personnel, equipment, materials, operating supplies, tools, supervision, and transportation, in accordance with the plans and specifications to perform all tasking within the associated Statement of Work.
This solicitation is a 100% Small Business set-aside, restricted to 8(a) firms. As such, competition for this solicitation is set aside for eligible 8(a) firms ONLY.
NAICS Code for this acquisition is 226220 - Commercial and Institutional Building Construction; Small Business Size Standard: $45M.
The magnitude of construction for this anticipated contract is estimated to be between $5,000,000.00 and $10,000,000.00.
| Jul 2, 2025 | [Presolicitation (Original)] Repair Ghost DFAC (Building 3757) |
| Aug 14, 2025 | [Solicitation (Original)] Repair Ghost DFAC (Building 3757) |
| Aug 26, 2025 | [Solicitation (Updated)] Repair Ghost DFAC (Building 3757) |
| Sep 3, 2025 | [Solicitation (Updated)] Repair Ghost DFAC (Building 3757) |
| Sep 10, 2025 | [Solicitation (Updated)] Repair Ghost DFAC (Building 3757) |

With GovernmentContracts, you can: