MU - New Basketball & Volleyball Arena

Location: Ohio
Posted: Oct 27, 2026
Due: Nov 11, 2026
Agency: Ohio Facility Construction Commission
Type of Government: State & Local
Category:
  • 78 - Recreational and Athletic Equipment
Solicitation No: MUN-100133
Publication URL: To access bid details, please log in.
Publish Date Due Date Number Owner Contractring Authority Project Name Primary Service Estimated Project Cost Q&A Short List Notes
2026/10/27 2026/11/11 MUN-100133 Miami University Local Higher Education MU - New Basketball & Volleyball Arena CxA $242,000,000 N/A TBD

Attachment Preview

Request for Qualifications (Commissioning Agent)
State of Ohio Standard Forms and Documents
Administration of Project: Local Higher Education
Project Name MU - New Basketball & Volleyball Arena Response Deadline 11/11/2026 1:30 pm local time
Project Location 200 S Fisher Drive Project Number MUN-100133
City / County Oxford/Butler Project Manager John Porchowsky
Owner Miami University Contracting Authority Local Higher Education
Delivery Method Design Build Prevailing Wages State
Publish Date 10/27/2026 Ohio Register Number
No. of paper copies requested (stapled, not bound) 3 No. of electronic copies requested on CD (PDF) 1
Submit the requested number of Statements of Qualifications (Form F110-330) directly to John Porchowsky at
jp@miamioh.edu. See Section H of this RFQ for additional submittal instructions. Paper copies will be mailed or hand
delivered by the due date to Miami University - Cole Service Building 101 S. Fisher Drive Oxford, Ohio 45056 ATTN: John
Porchowsky.
Submit all questions regarding this RFQ in writing to John Porchowsky at jp@miamioh.edu with the project number included in
the subject line (no phone calls please). Questions will be answered and posted to Opportunities page on the OFCC website
at http://ofcc.ohio.gov on a regular basis until one week before the response deadline. The name of the party submitting a
question will not be included on the Q&A document.
Project Overview
A. Project Description
This project comprises design-, construction- and acceptance-phase commissioning of the major building systems for the
a new basketball and volleyball arena on the Oxford campus of Miami University. The project will pursue LEED Silver
Certification; therefore, commissioning must comply with the requirements of both Fundamental and Enhanced
Commissioning credits for LEED v.4.
The Criteria Architect and the Owner are completing the programming and conceptual design phases. The contract will
commence with Schematic design review and continue from there to the end of the acceptance phase.
The project consists of constructing a new 256,000 gross square foot building located at 200 S Fisher Drive, Oxford, Ohio
45056.
The building systems envisioned to be commissioned include HVAC Systems, Electrical Systems, and Plumbing
Systems, Specialty low voltage electrical systems. HVAC systems include but are not limited to DOAS units, fan coil units,
data room units, smoke evacuation system, exhaust fans, unit heaters, chilled beams, variable air volume terminals /
valves, variable frequency drives, chilled water hydronic systems, hot water hydronic systems. Plumbing systems include
but are not limited to domestic hot water generation systems, domestic hot water return systems, water conditioning
systems, sanitary ejector pumps, storm sump pumps. Electrical systems include but are not limited to electrical motor
starters, electrical switchgear, lighting control systems, emergency generators, automatic transfer switches, and
distribution panels.
Members of the selected Design-Build team are as follows:
Design-Builder - Turner Construction Company
Architect of Record - MSA Design
Consulting Engineer - Heapy Engineering.
The criteria architecture team for the project is The SLAM Collaborative. The 100% design development drawings can
be found by clicking the link to a Google drive here.
B. Scope of Services
Miami University requests that prospective firms submit proposals that identify the most cost-effective scope of services
for the project identified above. Services may include some or all of the following:
Establish the verification and testing methods to be used during commissioning.
Develop the forms for recording of the systems performance and testing procedures/results.
F130-08-2026-JAN Publish Date: 10/27/2026; Ohio Register # Page 1 of 5

Request for Qualifications (Commissioning Agent) continued
Develop a Facility Requirements and Operations and Maintenance Plan including the following details:
* Sequence of operations for the building
* Building occupancy schedule
* Equipment run-time schedules
* Setpoints for all HVAC equipment
* Set lighting levels throughout the building
* Minimum outside air requirements
* Any changes in schedules or setpoints for different seasons, days of the week, and times of day
* A systems narrative describing the mechanical and electrical systems and equipment
* A preventive maintenance plan for building equipment described in the systems narrative
* A commissioning program that includes periodic commissioning requirements, ongoing commissioning tasks,
and continuous tasks for critical facilities
Develop a monitoring-based commissioning plan including the identification of points that will be measured and
evaluated. Scope shall include both energy and water-consuming systems. Provide as-needed updates to the systems
manual, including explanations for any modifications to the original design. The following items shall be included in
each monitoring-based commissioning plan:
* Roles and responsibilities
* Measurement requirements (meters, points, metering systems, data access)
* The points to be tracked, with frequency and duration for trend monitoring
* The limits of acceptable values for tracked points and metered values
* The elements used to evaluate performance, including conflict between systems, out-of-sequence operation of
systems components, and energy and water usage profiles
* An action plan for identifying and correcting operational errors and deficiencies
* Training to prevent errors
* Planning for repairs needed to maintain performance
* Frequency of analyses in the first year of occupancy (at least quarterly)
Provide thermal imaging of building envelopes and electrical equipment including but not limited to switchgear, panels,
motors, and other electrical equipment.
Provide details that cannot be, or were not, fully developed during design, such as scheduling of commissioning
activities, develop actual lines of reporting and approvals, coordination, etc.
Inspect the equipment and systems to verify proper installation and adequate operational checkout by installing
contractors.
Review and comment on all change orders affecting commissioned systems that may occur during the construction
phase.
Coordinate, conduct, and document the testing of equipment and systems during the commissioning phase.
Report to the owner and contractors any deficiencies in the specified building systems or equipment. Attend meetings to
review report and resolve issues. Identify party or parties responsible for correcting deficiencies.
Submit written monthly progress reports during the construction and acceptance phases.
Assist Owner and DB in the LEED v.4 documentation and certification process throughout the project and provide all
required commissioning forms and reports in formats required for LEED v.4 Silver certification at both the Design Phase
submission and Construction Phase submission.
Provide final report that all of the building systems have been commissioned and that they meet the design criteria and
design intent.
F130-08-2026-JAN Publish Date: 10/27/2026; Ohio Register # Page 2 of 5

Request for Qualifications (Commissioning Agent) continued
Return to the project to re-commission the HVAC systems during the season in which the HVAC systems were not
originally commissioned.
Provide other services deemed appropriate by the proposer for the given project that provide value to the University.
Participate in any conflict resolution efforts as it relates to commissioned equipment or areas of construction.
Additional Information
Owner's and DB's staff may attend any- or all-commissioning activities.
Commissioning authority's proposal should include a proposed average for hours per week on-site during the
construction phase, not including travel time or home office activities.
For this proposal, the selected firm will be required to separate their fee proposal into three parts:
1. Fundamental LEED Commissioning Services:
These Commissioning Services will meet the requirements of the Fundamental Building Systems Commissioning
Prerequisite, (EAp1) as described in the U.S. Green Building Council's (USGBC) Leadership in Energy &
Environmental Design LEED version 4.0.
2. Option 1 Path 1 & 2: Enhanced and Monitoring-Based Commissioning
3. Option 2: Enhanced Commissioning - Building Envelope Services
Final fee and final scope of services will be negotiated after selection.
The selected Commissioning Agent ("CxA"), as a portion of its required Scope of Services and prior to submitting its
proposals, will discuss and clarify with the Owner and/or the Contracting Authority, the cost breakdown of the Consultant
Agreement detailed cost components to address the Owner's project requirements. Participate in the Encouraging
Growth, Diversity & Equity ("EDGE") Program as required by statute and the Agreement.
As required by the Agreement, and as properly authorized, provide the following categories of services: Program
Verification, Schematic Design, Design Development, Construction Document Preparation, Construction Administration,
Post-Construction, and Additional Services of all types.
Refer to the Ohio Facilities Construction Manual for additional information about the type and extent of services required
for each. A copy of the standard Agreement can be obtained at the OFCC website at http://ofcc.ohio.gov.
During the construction period, provide not less than 8 hours (excluding travel time) on-site construction administration
services each week, including (1) attendance at progress meetings, (2) a written field report of each site visit, (3) on-site
representation comprised of the CxA and its consultant staff involved in the primary design of the project, all having
relevant and appropriate types of construction administration experience.
For purposes of completing the Relevant Project Experience Matrix in Section F of the Statement of Qualifications (Form
F110-330), below is a list of relevant scope of work requirements for this RFQ:
1. Sports Arena Commissioning
2. Large assembly spaces
3. Mechanical Systems
4. Electrical Systems
5. Smoke Evacuation Systems
6. Building Envelope
C. Funding / Estimated Budget
Total Project Cost $242,000,000t State Funding $0
Construction Cost $214,511,208 Other Funding $242,000,000
Estimated CxA Fee .1% to .15%
NOTE: The CxA fee percentage for this project includes all professional design services, and consultant services necessary for proper
F130-08-2026-JAN Publish Date: 10/27/2026; Ohio Register # Page 3 of 5

Request for Qualifications (Commissioning Agent) continued
completion of the commissioning services for the successful completion of the project.
D. Services Required (see note below) E. Anticipated Schedule
Primary Mechanical Professional Services Start 12 / 26
Secondary Electrical Construction Notice to Proceed 09 / 26
Envelope Substantial Completion of all Work 09 / 28
Fire Alarm - Smoke Evacuation Professional Services Completed 11 / 28
Plumbing
F. EDGE Participation Goal
Others Percent of initial Total CxA Fee 5%
G. Evaluation Criteria for Selection
* Demonstrated ability to meet Owner's project requirements.
* Previous experience compatible with the proposed project (e.g., type, size).
* Relevant past work of prospective firm's proposed consultants.
* Past performance of prospective firm and its proposed consultants.
* Qualifications and experience of individuals directly involved with the project.
* Proposer's previous experience (numbers of projects, sizes of projects) when working with its proposed
consultants.
* Specification writing credentials and experience.
* Approach to and success of using partnering and Alternative Dispute Resolution.
* Proximity of prospective firms to the project site.
* Proposer's apparent resources and capacity to meet the needs of this project.
* The selected CxA and all its consultants must have the capability to use the Internet within their normal business
location(s) during normal business hours.
Interested CxA firms are required to submit the Commitment to Participate in the EDGE Business Assistance Program
form in its Statement of Qualifications (Form F110-330) submitted in response to the RFQ, to indicate its intent to contract
with and use EDGE-certified Business(es), as a part of the CxA's team. The Intent to Contract and to Perform and / or
waiver request letter and Demonstration of Good Faith Effort form(s) with complete documentation must be attached to
the CxA's Technical Proposal. Both forms can be accessed via the OFCC website at http://ofcc.ohio.gov. The Intent to
Contract and to Perform form is again required at the Fee Proposal stage.
For all Statements of Qualifications, please identify the EDGE-certified Business(es), by name, which will participate in the
delivery of the proposed professional services solicited in the RFQ.
H. Submittal Instructions
Firms are required to submit the current version of Statement of Qualifications (Form F110-330) available via the OFCC
website at http://ofcc.ohio.gov.
Electronic submittals, if requested, should be combined into one PDF file named with the project number listed on the
RFQ and your firm's name, followed by "SOQ". Use the "print" feature of Adobe Acrobat or similar software for creating a
PDF rather than using a scanner. If possible, please reduce the file size of the PDF. In Acrobat, go to Advanced, then
PDF Optimizer. Electronic submittals are limited to a maximum file size of 25 MB.
Paper copies of the Statement of Qualifications, if requested, should be stapled only. Do not use special bindings or
coverings of any type. Cover letters and transmittals are not necessary.
Facsimile or e-mailed copies of the Statement of Qualifications will not be accepted.
Firms are requested to identify professional registrations, memberships, and any other appropriate design and
construction industry credentials. Identify that information on the resume page for individual in Block 22, Section E of the
F110-330 form.
F130-08-2026-JAN Publish Date: 10/27/2026; Ohio Register # Page 4 of 5

Selection Criteria Value Score
1. Primary Firm Location, Workload and Size (Maximum 10 points)
a. Proximity of firm to project site Less than 50 miles 5
50 miles to 100 miles 2
More than 100 miles 0
b. Amount of fees awarded by Contracting Authority in previous 24 months Less than $cc 2
$100,000 to $500,000 1
More than $500,000 0
c. Number of relevant professionals Less than 3 professionals 0 Max = 3
3 to 6 professionals 1
More than 6 professionals 2
2. Primary Qualifications (Maximum 30 points)
a. Project management lead Experience / ability of project manager to manage scope / budget / schedule / quality 0 - 10
b. Project administration lead Experience / ability to effectively administer project controls and processes 0 - 5 Max = 20
c. Technical staff Experience / ability of technical staff to verify fully coordinated construction documents 0 - 10
d. Construction administration staff Experience / ability of field representative to identify and solve issues during construction 0 - 5
3. Key Consultant Qualifications (Maximum 20 points)
a. Key discipline leads Experience / ability of key consultants to perform effectively and collaboratively 0 - 15
b. Proposed EDGE-certified Consultant participation* One additional point for every 2 percent 0 - 5
increase in professional services over the
advertised EDGE participation goal
4. Overall Team Qualifications (Maximum 10 points)
a. Previous team collaboration Less than 2 sample projects 0
2 to 4 sample projects 2
More than 4 sample projects 5
b. Team organization Clarity of responsibility / communication demonstrated by table of organization 0 - 5
5. Overall Team Experience (Maximum 30 points)
a. Previous team performance Past performance as indicated by evaluations and letters of reference 0 - 10
b. Experience with similar projects / delivery methods Less than 2 projects 0 - 3
2 to 6 projects 4 - 6
More than 6 projects 7 - 10
c. Budget and schedule management Performance in completing projects within original construction budget and schedule 0 - 5
d. Knowledge of Ohio Capital Improvements process Less than 2 projects 0 - 1
2 to 6 projects 2 - 3
More than 6 projects 4 - 5
Subtotal

Commissioning Agent Selection Rating Form
State of Ohio Standard Forms and Documents
Project Name MU - New Basketball Volleyball Arena Proposer Firm Proposer Firm
Project Number MUN-100133 City, State, Zip City, State, Zip
Selection Criteria Value Score
1. Primary Firm Location, Workload and Size (Maximum 10 points)
Less than 50 miles 5
a. Proximity of firm to project site 50 miles to 100 miles 2
More than 100 miles 0
Less than $cc 2
b. Amount of fees awarded by Contracting Authority in
$100,000 to $500,000 1
previous 24 months
More than $500,000 0
Less than 3 professionals 0
Max
c. Number of relevant professionals 3 to 6 professionals 1
= 3
More than 6 professionals 2
2. Primary Qualifications (Maximum 30 points)
Experience / ability of project manager to
a. Project management lead 0 - 10
manage scope / budget / schedule / quality
Experience / ability to effectively administer
b. Project administration lead 0 - 5
project controls and processes
Experience / ability of technical staff to verify Max =
c. Technical staff 0 - 10
fully coordinated construction documents 20
Experience / ability of field representative to
d. Construction administration staff 0 - 5
identify and solve issues during construction
3. Key Consultant Qualifications (Maximum 20 points)
Experience / ability of key consultants to
a. Key discipline leads 0 - 15
perform effectively and collaboratively
One additional point for every 2 percent
b. Proposed EDGE-certified Consultant participation* increase in professional services over the 0 - 5
advertised EDGE participation goal
4. Overall Team Qualifications (Maximum 10 points)
Less than 2 sample projects 0
a. Previous team collaboration 2 to 4 sample projects 2
More than 4 sample projects 5
Clarity of responsibility / communication
b. Team organization 0 - 5
demonstrated by table of organization
5. Overall Team Experience (Maximum 30 points)
Past performance as indicated by evaluations
a. Previous team performance 0 - 10
and letters of reference
Less than 2 projects 0 - 3
b. Experience with similar projects / delivery methods 2 to 6 projects 4 - 6
More than 6 projects 7 - 10
Performance in completing projects within
c. Budget and schedule management 0 - 5
original construction budget and schedule
Less than 2 projects 0 - 1
d. Knowledge of Ohio Capital Improvements process 2 to 6 projects 2 - 3
More than 6 projects 4 - 5
* Must be comprised of professional design services consulting firm(s) and NOT the primary firm
Subtotal
** Leadership in Energy & Environmental Design administered by the Green Building Certification Institute
Notes: Evaluator:
Name
Signature Date
F130-08-2026-JAN Publish Date: 10/27/2026; Ohio Register # Page 5 of 5

This is the opportunity summary page. It provides an overview of this opportunity and a preview of the attached documentation.
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

Project ID: GD 26-53 Title: Maintenance Facility Painting Project Addenda: 0 Release Date:

Greater Dayton Regional Transit Authority

Bid Due: 12/01/2026

OWP - Knox 10 October 16, 2026 | ODNR Project Name Knox 10

State of Ohio - Department of Natural Resources

Bid Due: 11/19/2026

DCS 2027 Roof Replacement at Wright Elementary Schools Bids are due at or

Dublin City Schools

Bid Due: 11/17/2026

Bid Title: City of Gahanna's Urban Forestry Master Plan Category: Request for Proposals

City of Gahanna

Bid Due: 11/20/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.