| Location: | Mississippi |
|---|---|
| Posted: | Jul 22, 2026 |
| Due: | Aug 12, 2026 |
| Agency: | State Government of Mississippi |
| Type of Government: | State & Local |
| Category: |
|
| Solicitation No: | 9280-27-R-IFBD-00002 |
| Publication URL: | To access bid details, please log in. |
Procurement Details
| Smart Number | 9280-27-R-IFBD-00002 | Advertised Date | 07/22/2026 8:00 AM |
| RFx # | 3160008183 | Submission Date | 08/12/2026 2:00 PM |
| RFx Status | Open | Major Procurement Category | COMMODITIES |
| RFx Opening Date | 08/12/2026 2:00 PM | Sub Procurement Category | EQUIPMENT - NON-TECHNOLOGY |
| RFx Type | Invitation for Bid | ||
| Agency | UNIVERSITY OF SOUTHERN MISSISSIPPI | ||
| RFx Description | USM is seeking Double-Wall Insulated Vertical Towers and Associated Accessories | ||
| Name | Millissa Stork | millissa.stork@usm.edu | |
| Phone | 2288188001 | Fax |
| PRODUCT CATEGORY | PRODUCT DESCRIPTION |
| 83044 | Polyethylene Tanks |
| VENDOR NAME | VENDOR NUMBER | AWARD DATE | AWARD AMOUNT | FUNDING SOURCE |
|
Attachments
Bid 27_04 Bid Packet |
|
|
Attachments
Bid 27_04 Cover Sheet |
|
|
Attachments
Bid 27_04 Legal Ad |
|
|
Attachments
Bid 27_04 Specs Double Wall Insulated Vert Towers and Associated |
Bid # 27_04
RFX 3160008183
University of Southern Mississippi
Technical Specifications - Double-Wall Insulated Vertical Towers and Associated
Accessories
1. General Requirements
The University of Southern Mississippi is soliciting sealed bids for the procurement and delivery of
double-wall insulated vertical towers and associated accessories for installation at the Oyster
Hatchery and Research Center (OHRC), currently under construction at the Gulf Coast Research
Laboratory Cedar Point Campus.
The double-wall insulated vertical towers shall be new, unused, and of current manufacture. All
equipment furnished shall meet or exceed the specifications contained herein.
Reference to a preferred manufacturer, vendor, or model number is intended solely to establish
the minimum quality, performance, and functional requirements of the equipment. Equivalent
products may be considered provided they meet or exceed all listed specifications and
compatibility requirements.
Vendors shall clearly identify any deviations from these specifications in their bid submission.
Final inlet locations, orientations, and connection requirements for each double-wall insulated
vertical tower will be provided by the University following contract award and prior to fabrication.
The awarded vendor shall accommodate these requirements to ensure compatibility with facility
plumbing and installation requirements.
2.Intended Application
The double-wall insulated vertical towers will be utilized in marine aquaculture operations for
applications including, but not limited to, artificial seawater preparation, brine storage, dissolved
oxygen systems, wastewater handling, salinity monitoring, and other hatchery support functions.
Each tower shall be specifically designed for aquaculture and marine environments and
constructed using materials that are corrosion resistant, chemically compatible with seawater and
associated treatment chemicals, and suitable for long-term service in a commercial hatchery
facility.
1
3. Tank Specifications
3A. Insulated 10,000 Gallon Vertical HDPE Tank
Quantity: 2
Preferred Manufacturer: Bailiff Enterprises, Inc.
Product Number: IVTB10000-95-1.5
Minimum Technical Specifications
* Capacity: 10,000 gallons
* Dimensions: 146-inch diameter x 148-inch height
* Specific Gravity Rating: Minimum 1.2
* Color: UV-stabilized to inhibit algae growth
* Type: Vertical insulated single-wall tank
* Material: HDPE
* Insulation suitable for temperature control applications
* Suitable for potable water, fertilizer, and industrial chemical applications
Configuration
* Welded pipe support, if available
* Twenty-four (24) inch manhole opening on top
* Additional thirty (30) inch sidewall opening
Connection Characteristics
Top Pipe Entry (Bulkhead)
* Two (2) 2-inch inlets
* Two (2) 1-inch inlets
* One (1) 3-inch inlet
* Bulkhead for ultrasonic level sensor
* Four (4) inch PVC exhaust U-vents
Bottom Pipe Entry (Bulkhead)
* One (1) 2-inch outlet
2
3B. Insulated 5,000 Gallon Vertical HDPE Tank
Quantity: 2
Preferred Manufacturer: Bailiff Enterprises, Inc.
Product Number: IVTB05000-95-1.5
Minimum Technical Specifications
* Capacity: 5,000 gallons
* Diameter: 95 inches
* Specific Gravity Rating: Minimum 1.2
* Color: UV-stabilized to inhibit algae growth
* Type: Insulated single-wall vertical tank
* Material: HDPE
* Insulation suitable for temperature control applications
* Suitable for potable water, fertilizer, and industrial chemical applications
* Tie-downs suitable for wind loading conditions
Configuration
* Twenty-four (24) inch top manhole opening
* Additional thirty (30) inch sidewall opening
* Welded pipe support, if available
Connection Characteristics
Top Pipe Entry (PVC Threaded Bulkhead)
* Three (3) 2-inch inlets
* Two (2) 1-inch inlets
* One (1) 3-inch inlet
* Bulkhead for ultrasonic level sensor
* Four (4) inch PVC exhaust U-vents
Bottom Pipe Entry (PVC Threaded Bulkhead)
* One (1) 2-inch outlet
3
3C. Insulated 800 Gallon HDPE Double-Wall Vertical Tank
Quantity: 6
Preferred Manufacturer: Bailiff Enterprises, Inc.
Product Number: VTBDC0800-64-1.9
Minimum Technical Specifications
* Capacity: 800 gallons
* Dimensions: 64-inch diameter x 75-inch height
* Specific Gravity Rating: Minimum 1.2
* Color: UV-stabilized to inhibit algae growth
* Type: Double-wall vertical tank
* Material: HDPE with 2-inch polyurethane closed-cell foam insulation
* Suitable for temperature-controlled applications
* Suitable for potable water, fertilizer, and industrial chemical applications
Connection Characteristics
Pipe Entry (PVC Threaded Bulkhead)
* Four (4) 2-inch inlets
* Three (3) inch PVC exhaust U-vents
Pipe Outlet (Bulkhead)
* One (1) 2-inch outlet
4
4. Delivery Requirements
* FOB Destination: University of Southern Mississippi
* Vendor shall coordinate delivery with University personnel prior to shipment.
* All items shall be packaged to prevent damage during transit.
* Each shipment shall include:
Packing list
o
Applicable product documentation
o
* Vendor shall provide estimated delivery timeline with bid submission.
* Vendor shall identify any special unloading or rigging requirements at time of bid
submission
5

With GovernmentContracts, you can:
...- Fuel Tank Relocation.pdf ADVERTISEMENT FOR BIDS NOTICE is hereby given that the ...
State Government of Mississippi
Bid Due: 9/09/2026
...tank and fuel pump serving the generator, and the Automatic Transfer Switch (ATS). ...
DEPT OF DEFENSE
Bid Due: 9/03/2026
...PRODUCT DESCRIPTION 83073 Steel Tanks, Water Awarded VENDOR NAME VENDOR NUMBER AWARD DATE ...
State Government of Mississippi
Bid Due: 9/10/2026
...tank and fuel pump serving the generator, and the Automatic Transfer Switch (ATS). ...
DEPT OF DEFENSE
Bid Due: 9/03/2026