Dental Lab At Juanita Sanchez Educational Complex Drawings

Location: Rhode Island
Posted: Oct 19, 2026
Due: Nov 16, 2026
Agency: City of Providence
Type of Government: State & Local
Category:
  • 65 - Medical, Dental, and Veterinary Equipment and Supplies
  • Q - Medical Services
Publication URL: To access bid details, please log in.

Dental Lab At Juanita Sanchez Educational Complex Drawings

Attachment Preview

BUILDING SITE
LOCUS MAP JS DENTAL LAB PROJECT TITLE:
THURBERS AVENUE JS Dental Lab
PROVIDENCE, RI 02905
182 Thurbers Avenue
Providence, RI 02905
ARCHITECTURAL MECHANICAL
M1.1 MECHANICAL PROPOSED PLAN - DUCTWORK
A0.0 COVER SHEET
A0.1 ABBREVIATIONS, SYMBOLS, & MATERIALS
A0.2 GENERAL NOTES
A0.3 LIFE SAFETY/CODE DIAGRAM
PLUMBING
PROJECT NUMBER:
P0.1 PLUMBING LEGEND, NOTES, & SCHEDULES
AD1.1 DEMO FLOOR PLAN 2601
PD1.0 PLUMBING DEMO FLOOR PLAN - SANITARY, WASTE, & VENT
AD1.2 DEMO RC PLAN
PD1.1 PLUMBING DEMO FLOOR PLAN - DOMESTIC WATER & GAS
P1.0 PLUMBING PROPOSED FLOOR PLAN - SANITARY, WASTE, & VENT
A1.1 NEW WORK FLOOR PLAN
P1.1 PLUMBING PROPOSED FLOOR PLAN - DOMESTIC WATER & GAS
A1.2 NEW WORK RC PLAN
P2.0 PLUMBING DETAILS
A6.0 DOOR & WINDOW SCHEDULE;
WALL TYPES AND DETAILS;
FINISH SCHEDULE & SPECIFICATIONS
ELECTRICAL
E0.1 ELECTRICAL LEGEND
ED1.0 ELECTRICAL DEMO FLOOR PLAN - LIGHTING
ED1.1 ELECTRICAL DEMO FLOOR PLAN - POWER
E1.0 ELECTRICAL PROPOSED FLOOR PLAN - LIGHTING
E1.1 ELECTRICAL PROPOSED FLOOR PLAN - POWER
E2.0 ELECTRICAL SPECIFICATIONS
FIRE ALARM
FA0.1 FIRE ALARM LEGEND
FA1.0 ELECTRICAL PROPOSED FLOOR PLAN - FIRE ALARM
FIRE PROTECTION
FP0.1 FIRE PROTECTION LEGEND
FPD1.0 FIRE PROTECTION DEMO FLOOR PLAN
FP1.0 FIRE PROTECTION PROPOSED FLOOR PLAN
ISSUED FOR:
BIDDING
10/14/2026
STAMP:
RU SSELL
A
C R
R I M
E Y
* *
ARCHITECT
ARCHITECT MEP+FP ENGINEERS
Eric Army, AIA
Owner
Juanita Sanchez
Educational Complex
Signal Works BUILDING ENGINEERING RESOURCES
11 Aleppo Street 66 MAIN STREET
Providence, RI 02909 NORTH EASTON, MA 02356
182 Thurbers Avenue
p 401 . 400 . 2724 P: (508) 230.0260
Providence, RI 02905
p (401) 456-1781

ABBREVIATIONS SYMBOLS
EELLEEVVAATTIIOONN
((IINN PPLLAANN))
WWAALLLL SSEECCTTIIOONN
DDEETTAAIILL
1
4 2 IINNTTEERRIIOORR EELLEEVVAATTIIOONN
3 /A 3
6
.1
DDOOOORR TTAAGG
FINISH TAG 11 Aleppo Street
Providence RI 02909
WWIINNDDOOWW TTAAGG 401.400.2724
SignalWorksArchitecture.com
WINDOW CONDITIONS TAG
CONSULTANT:
WWAALLLL TTYYPPEE
CCEEIILLIINNGG TTYYPPEE
ROOM TAG
DDAATTUUMM//SSPPOOTT EELLEEVVAATTIIOONN
RREEVVIISSIIOONN TTAAGG
PROJECT TITLE:
JS Dental Lab
CCAALLLLOOUUTT
182 Thurbers Avenue
Providence, RI 02905
CCOOLLUUMMNN GGRRIIDD RREEFFEERREENNCCEE
NOTE
ALIGN
ALIGN FINISHES OF NOTED
ELEMENTS
ISSUED FOR:
BIDDING
10/14/2026
TITLE MARK
REVISIONS:
MATERIALS
STAMP:
ALUMINUM GRAVEL
RU SSELL
A
C R
R I M
E Y
BATT GYPSUM * *
INSULATION PLASTER ARCHITECT
BRICK, PLYWOOD
STONE
SHEET TITLE:
MASONRY
ABBREVIATION, SYMBOL, AND
MATERIALS
CONCRETE RIGID
INSULATION
PROJECT NORTH:
N
CONCRETE STEEL
MASONRY
PROJECT ARCHITECT: BTB
DRAWN:MM
EARTH DIMENSIONAL BLOCKING
LUMBER PROJECT NUMBER:
#2601
SHEET NUMBER: REV:
A0.1 ~

GENERAL CONDITIONS NOTES: CODE REFERENCES ARCHITECTURAL GENERAL NOTES:
1. THE CONTRACTOR SHALL VISIT THE SITE AND BE FULLY COGNIZANT OF ALL EXISTING CONDITIONS PRIOR TO SUBMITTING ANY PROPOSITIONS OR BIDS. IF ANY RISBC-1 RHODE ISLAND BUILDING CODE (510-RICR-00-00-1) INCORPORATES THE INTERNATIONAL BUILDING CODE, 2021 EDITION, BY REFERENCE.
ASBESTOS, KNOWN MATERIALS CONTAINING ASBESTOS OR ANY MATERIALS CLASSIFIED BY THE EPA AS HAZARDOUS MATERIALS ARE DISCOVERED, THEN THE
CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH THE OWNER, AS REQUIRED, FOR THE REMOVAL OF THESE CONDITIONS, PRIOR TO THE BEGINNING OF NFPA 1 - FIRE CODE (2021 EDITION) ADOPTED AS THE FOUNDATION OF THE RHODE ISLAND FIRE CODE.
THIS PROJECT. IF THE CONTRACTOR PARTICIPATES IN ANY PORTION OF THE REMOVAL PROCESS IN HIS COORDINATION WITH THE OWNER, THEN THE CONTRACTOR
SHALL PROVIDE THE OWNER WITH A WRITTEN STATEMENT RELEASING THE OWNER OF ANY FUTURE LIABILITY FROM THE CONTRACTOR, HIS EMPLOYEES AND ANY NFPA 101 - LIFE SAFETY CODE (2021 EDITION) ADOPTED AS THE BASIS FOR THE RHODE ISLAND LIFE SAFETY CODE (RILSC).
SUBCONTRACTORS HIRED BY THE CONTRACTOR RELATED TO THIS WORK. THESE DRAWINGS AND SPECIFICATIONS DO NOT REPRESENT AN ASSESSMENT OF THE
PRESENCE OR AN ASSESSMENT OF THE ABSENCE OF ANY TOXIC OR HAZARDOUS MATERIALS ON THIS PROJECT SITE. THE OWNERS ARE SOLELY RESPONSIBLE FOR SUCH NFPA 101 CHAPTER 43 - BUILDING REHABILITATION NOW INCLUDED IN THE RILSC FOR CLEARER GUIDANCE ON REQUIREMENTS IN EXISTING BUILDINGS.
AN ASSESSMENT AND SHOULD BE CONSULTED FOR ANY QUESTIONS THEREIN. IF THE CONTRACTOR DISCOVERS ANY TOXIC OR HAZARDOUS MATERIALS, AS DEFINED BY
THE APPROPRIATE GOVERNING AUTHORITIES, IN THE COURSE OF HIS WORK, HE MUST NOTIFY THE OWNERS IN WRITING, AS PER THE GUIDELINES BY ALL GOVERNING RISBC-3 RHODE ISLAND PLUMBING CODE (510-RICR-00-00-3) INCORPORATES THE INTERNATIONAL PLUMBING CODE, 2021 EDITION, BY REFERENCE.
AUTHORITIES. THE CONTRACTOR SHALL RESOLVE THE APPLICABLE REGULATIONS AND PROCEDURES WITH THE OWNER AT THE TIME OF DISCOVERY.
2. ALL THE DIMENSIONS OF EXISTING CONDITIONS SHOWN, OR NOT SHOWN BUT REQUIRED, MUST BE VERIFIED IN THE FIELD BY THE CONTRACTOR PRIOR TO
RISBC-4 RHODE ISLAND MECHANICAL CODE (510-RICR-00-00-4) INCORPORATES THE INTERNATIONAL MECHANICAL CODE, 2021 EDITION, BY REFERENCE.
CONSTRUCTION. LABELED DIMENSIONS CONTROL THE DESIGN INTENT, DO NOT SCALE DRAWINGS. DIMENSIONS FOR PROPOSED WORK ARE NOT ADJUSTABLE
2. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES, LAWS, ORDINANCES AND LOCAL MUNICIPAL REGULATIONS AND AMENDMENTS RELATED
WITHOUT APPROVAL FROM THE ARCHITECT.
TO THIS PROJECT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE OWNER AT ONCE UPON DISCOVERY OF ANY CONFLICTS OR DISCREPANCIES RISBC-5 RHODE ISLAND ELECTRICAL CODE (510-RICR-00-00-5) INCORPORATES THE NATIONAL ELECTRICAL CODE, 2023 EDITION, BY REFERENCE.
BETWEEN THE AFOREMENTIONED AND THE WORK CONTRACTED FOR THIS PROJECT OR A CHANGE OF AN APPLICABLE CODE OR STATUE BY LOCAL AUTHORITIES.
3. PROVIDE ALL TEMPORARY FRAMING AND SHORING REQ'D TO SUPPORT EXISTING STRUCTURE DURING DEMOLITION AND ALTERATION OF ANY LOAD BEARING BUILDING
RISBC-7 RHODE ISLAND EXISTING BUILDING CODE (510-RICR-00-00-7) INCORPORATES THE INTERNATIONAL EXISTING BUILDING CODE, 2021 EDITION, BY REFERENCE
COMPONENTS.
3. THE CONTRACTOR SHALL COORDINATE AND BE RESPONSIBLE FOR ALL WORK BY HIS SUBCONTRACTORS AND THEIR COMPLIANCE WITH ALL THESE GENERAL NOTES.
THE CONTRACTOR SHALL IDENTIFY ANY CONFLICTS BETWEEN THE WORKS OF THE SUBCONTRACTORS, AS DIRECTED BY THESE DRAWINGS, DURING THE LAYOUT OF RISBC-8 STATE OF RHODE ISLAND ENERGY CONSERVATION CODE (510-RICR-00-00-8) INCORPORATES THE IECC, 2024 EDITION, W/ AMENDMENTS
4. PROVIDE TEMPORARY, SECURE / WEATHER-PROOF ENCLOSURE @ ALL NEW AND ALTERED OPENINGS TO EXTERIOR DURING DEMOLITION AND CONSTRUCTION.
THE AFFECTED TRADES. THE CONTRACTOR SHALL REVIEW THESE CONDITIONS WITH THE ARCHITECTURAL DESIGNER FOR DESIGN CONFORMANCE BEFORE BEGINNING
ANY INSTALLATION.
5. PROVIDE TEMPORARY DUST-PROOF BARRIERS BETWEEN AREA OF WORK AND EXISTING INTERIOR SPACES TO REMAIN.
4. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING AND PROPOSED DIMENSIONS AND CONDITIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE SITE INFORMATION NOTES:
6. PRIOR TO BEGINNING DEMOLITION, IDENTIFY WITH OWNER ANY APPLIANCES, CABINETS, FIXTURES OR OTHER ITEMS TO BE SELECTIVELY REMOVED AND STORED
OWNER AT ONCE UPON THE DISCOVERY OF ANY CONFLICTS OR DISCREPANCIES BETWEEN THE AFOREMENTIONED AND THE DRAWINGS AND SPECIFICATIONS OF THIS
ONSITE FOR FUTURE REUSE.
PROJECT. THE CONTRACTOR SHOULD FOLLOW DIMENSIONS AND SHOULD NOT SCALE THESE DRAWINGS. IF DIMENSIONS ARE REQUIRED BUT NOT SHOWN, THEN THE
PARCEL ID: MAP 54/LOT 923
CONTRACTOR SHALL REQUEST THE DIMENSIONS FROM THE OWNER BEFORE BUILDING ANY PART OF THE PROJECT, WHICH REQUIRES THE MISSING DIMENSIONS.
7. DEMOLISH FIXTURES AND EQUIPMENT AS SHOWN, REMOVE ALL ASSOCIATED PLUMBING & WIRING NOT TO BE REUSED IN NEW WORK.
LOT AREA: 215,186.4 SF
5. ANY CHANGES, ALTERNATIVES OR MODIFICATIONS TO THESE DRAWINGS AND SPECIFICATIONS MUST BE APPROVED IN WRITING BY THE OWNER, AND ONLY WHEN SUCH
8. OWNER TO DETERMINE IN FIELD WITH CONTRACTOR EXTENT TO WHICH EXISTING FLOORING DISTURBED BY CONSTRUCTION WILL BE REMOVED AND REPLACED.
WRITTEN APPROVAL CLEARLY STATES THE AGREED COST OR CREDIT OF THE CHANGE, ALTERNATIVE OR MODIFICATION TO THIS PROJECT. FOR INFORMATION,
TOTAL BUILDING AREA: 110,000 SF CONTRACTOR SHALL SUGGEST APPROPRIATE STEPS TO ADEQUATELY REFINISH FLOORING AS NEEDED.
DRAWINGS OR OTHER DOCUMENTS, NOT SHOWN OR INCLUDED IN THE PERMIT OR CONSTRUCTION DRAWINGS OR SPECIFICATIONS, THE CONTRACTOR SHALL REQUEST
THE MISSING INFORMATION, DRAWINGS OR DOCUMENTS FROM THE OWNER BEFORE STARTING OR PROCEEDING WITH THE CONSTRUCTION AFFECTED BY THE MISSING
LAND USE: PUBLIC SPACE (PS) 9. IN NO CASE SHALL DIMENSIONS BE SCALED FROM DRAWINGS. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS IN THE FIELD BEFORE PROCEEDING 11 Aleppo Street
INFORMATION, DRAWINGS OR DOCUMENTS.
WITH SUBSEQUENT WORK. Providence RI 02909
EXISTING BUILDING TYPE: IIIB
6. THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS IS TO PROVIDE THE DESIGN GUIDANCE FOR THE CONTRACTOR TO REASONABLY PLAN FOR ALL ITEMS 401.400.2724
10. ALL DIMENSIONS ARE TO CENTER LINE ( ) OF NEW WALLS AND FACE OF FINISH TO EXISTING WALLS UNLESS OTHERWISE NOTED.
NECESSARY FOR A COMPLETE JOB. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL MATERIALS, LABOR AND EXPERTISE NECESSARY TO ACHIEVE A
EXISTING USE: EDUCATION SignalWorksArchitecture.com
COMPLETE JOB AS INTENDED IN THESE DRAWINGS AND SPECIFICATIONS. THE CONTRACTOR IS FULLY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS,
11. DIMENSIONS MARKED "MIN." INDICATE A MINIMUM CLEARANCE THAT MUST BE MAINTAINED.
TECHNIQUES, SEQUENCES, FINAL DIMENSIONS AND PROCEDURES FOR THE WORK SHOWN ON THESE DRAWINGS AND SPECIFICATIONS. IT IS THE CONTRACTOR'S
CONSULTANT:
PROPOSED USE: NO CHANGE
RESPONSIBILITY TO ENACT THE AFOREMENTIONED IN COMPLIANCE WITH GENERALLY ACCEPTED STANDARDS OF PRACTICE FOR THE CONSTRUCTION INDUSTRY FOR
12. REFER TO SHEET A0.0 FOR SYMBOLS AND ABBREVIATIONS. REFER TO SHEETS A0.1, ET. AL. FOR GENERAL NOTES AND SPECIFICATIONS
THE TYPE OF WORK SHOWN ON THESE DRAWINGS AND SPECIFICATIONS. THE OWNER RESERVES THE RIGHT OF REVIEW FOR ALL MATERIALS AND PRODUCTS FOR
NUMBER OF STORIES: 3
WHICH NO SPECIFIC BRAND NAME OR MANUFACTURER IS IDENTIFIED IN THESE DRAWINGS AND SPECIFICATIONS. (7?) THE CONTRACTOR SHALL VERIFY WITH THE
13. ALL FINISH WALL SURFACES TO BE FLUSH UNLESS NOTED OTHERWISE. PROVIDE FURRING AS REQUIRED.
OWNER THE NEED FOR SHOP DRAWINGS OR SAMPLES OF MATERIALS OR PRODUCTS, WHICH WERE NOT IDENTIFIED IN THESE DRAWINGS OR SPECIFICATIONS, AS WELL
SPRINKLERED: YES
AS ANY MATERIAL, PRODUCT OR EQUIPMENT SUBSTITUTIONS PROPOSED IN PLACE OF THOSE ITEMS IDENTIFIED IN THESE DRAWINGS AND SPECIFICATIONS.
14. ALL GYP. BD. WALLS TO BE TAPED, SANDED AND PRIMED TO LEVEL 5 FINISH ("IMPERIAL" PLASTER SKIMCOAT, PRIMED AND PAINTED) UNLESS NOTED OTHERWISE.
7. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY AND COORDINATE ALL UTILITY CONNECTIONS, UTILITY COMPANIES' REQUIREMENTS AND INCLUDE ANY RELATED
15. ALL WORK SHALL COMPLY WITH CURRENTLY ADOPTED STATE BUILDING CODE AND ASSOCIATED CODES ADOPTED VIA INCORPORATION.
COSTS ASSOCIATED WITH THIS RESPONSIBILITY IN THE PROPOSAL OR BID. THE CONTRACTOR IS ALSO RESPONSIBLE FOR WRITING LETTERS OF CONFORMATION
DEMOLITION GENERAL NOTES:
REGARDING OPERATIVE AGREEMENTS FOR THIS PROJECT BETWEEN THE CONTRACTOR AND THE LOCAL FIRE DEPARTMENT; THE LOCAL WATER AGENCY; THE LOCAL
16. IF THE ARCHITECT HAS NOT BEEN RETAINED FOR CONSTRUCTION ADMINISTRATION, THEN THE ARCHITECT IS NOT RESPONSIBLE FOR SEEING THAT THE CONTRACTOR
NATURAL OR PROPANE GAS PROVIDER; THE LOCAL ELECTRICITY PROVIDER; THE LOCAL TELEPHONE SERVICE PROVIDERS; THE LOCAL CABLE TV PROVIDER; THE
1. THE DEMOLITION WORK SHOWN ON THESE DRAWINGS MAY NOT BE THE COMPLETE DEMOLITION REQUIRED TO ACCOMMODATE THE NEW WORK, WHICH IS SHOWN ADHERES TO THE CONSTRUCTION DRAWINGS.
OWNER'S SECURITY SERVICE PROVIDER AND ANY UNNAMED UTILITY TYPE SERVICE PROVIDER. THE CONTRACTOR SHALL PROVIDE COPIES OF ANY SUCH AGREEMENTS
ELSEWHERE. THE INTENT OF THESE DRAWINGS IS TO GENERALLY SHOW THE DEMOLITION SCOPE OF WORK EXPECTED OF THE CONTRACTOR. THE CONTRACTOR
TO THE OWNER, IF REQUIRED OR REQUESTED.
WILL BE RESPONSIBLE TO COORDINATE ANY ADDITIONAL DEMOLITION WORK AND VERIFY THE EXTENT OF DEMOLITION REQUIRED IN ORDER TO ACCOMMODATE
MECHANICAL GENERAL NOTES:
ANY NEW WORK.
8. THE CONTRACTOR IS FULLY RESPONSIBLE TO ENACT THE APPROPRIATE SAFETY PRECAUTIONS REQUIRED TO MAINTAIN A SAFE WORKING ENVIRONMENT. THE
CONTRACTOR SHALL ALSO INDEMNIFY AND HOLD HARMLESS THE OWNER, THEIR CONSULTANTS AND EMPLOYEES FROM ANY PROBLEMS, WHICH RESULT FROM THE
2. ALL THE DIMENSIONS SHOWN, OR NOT SHOWN BUT REQUIRED, MUST BE VERIFIED IN THE FIELD BY THE CONTRACTOR PRIOR TO CONSTRUCTION. THE 1. IT IS THE INTENTION OF THE DESIGNER, THAT ALL MECHANICAL DUCTS, WIRING, EQUIPMENT AND OTHER MECHANICAL WORK WILL BE CONCEALED WITHIN THE
CONTRACTOR'S PERFORMANCE OF THE WORK RELATED TO THE SAFETY OF THE CONSTRUCTION SITE.
INFORMATION SHOWN ON THESE DRAWINGS WAS DERIVED BY THE ARCHITECTURAL DESIGNER WITHOUT ANY SURVEYING OR ENGINEERING EQUIPMENT AND IS WALL, FLOOR, CEILING OR ROOF STRUCTURE OF THE BUILDING, EXCEPT IN AREAS WITH OPEN CEILINGS OR IN UTILITY ROOMS. THE CONTRACTOR WILL REVIEW
9. THE CONTRACTOR SHALL CARRY THE APPROPRIATE WORKMAN'S COMPENSATION AND LIABILITY INSURANCE, AS REQUIRED BY THE LOCAL GOVERNMENT AGENCY INTENDED TO BE HELPFUL, BUT NOT NECESSARILY ACCURATE. WITH THE DESIGNER ANY CONFLICTS WITH THIS INTENTION BEFORE FRAMING IS ENCLOSED OR ANY DEVICE IS INSTALLED.
HAVING JURISDICTION FOR THIS ISSUE, AS WELL AS COMPLY WITH THE GENERALLY ACCEPTED INDUSTRY STANDARDS OF PRACTICE FOR A PROJECT OF THIS SCOPE. IT
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY WITH THE OWNER, IF HE WILL BE REQUIRED TO CARRY FIRE INSURANCE OR OTHER TYPES OF 3. ALL BIDS OR PROPOSALS MUST CLEARLY IDENTIFY WHAT WORK WILL BE PERFORMED AND WHAT WORK WILL NOT BE PERFORMED. THE CONTRACTOR WILL ALSO 2. ALL EXTERIOR AND INTERIOR GRILLES AND LOUVERS SHALL BE CENTERED OR ALIGNED WITH SIGNIFICANT ARCHITECTURAL DESIGNER OBJECTS SUCH AS DOORS, PROJECT TITLE:
INSURANCE, AS WELL AS, MAKING THE OWNER ADDITIONALLY INSURED ON THEIR POLICIES FOR THE DURATION OF THE PROJECT. HE SHOULD ALSO ASSIST THE IDENTIFY ANY ALLOWANCES FOR WORK TOO UNCERTAIN TO BID FROM THE INFORMATION SHOWN ON THESE DRAWINGS. WINDOWS OR OTHER ADJACENT ELEMENTS. THE CONTRACTOR WILL REVIEW WITH THE DESIGNER ANY CONFLICTS WITH THIS INTENTION DURING THE REVIEW OF JS Dental Lab
THE SYSTEM LAYOUT SUBMITTAL (SEE DESIGN/BUILD REQUIREMENTS).
OWNER IN IDENTIFYING THE AMOUNT OF COVERAGE REQUIRED FOR THEIR CO-INSURANCE NEEDS.
4. THE CONTRACTOR WILL COORDINATE THE CAPPING AND PATCHING OF ALL EXISTING PLUMBING FIXTURES, SPRINKLER SYSTEMS AND RELATED EQUIPMENT
SHOWN TO BE REMOVED WITH THE EXISTING ROUGH-IN SYSTEM TO REMAIN. THE CONTRACTOR WILL VERIFY THE WORK REQUIRED FOR INSTALLING AND 3. THE CONTRACTOR WILL VERIFY THE DUCT ROUTE AND TERMINATION DEVICES AT THE EXTERIOR FOR ALL EXHAUST FANS, RANGE EXHAUST OR OTHER SIMILAR
10.THE CONTRACTOR SHALL MAINTAIN A CLEAN AND ORDERLY JOB SITE ON A DAILY BASIS. THE CONTRACTOR SHALL NOT UNREASONABLY ENCUMBER THE SITE WITH
CONNECTING NEW PLUMBING FIXTURES AND RELATED EQUIPMENT, AS SHOWN ON THE NEW WORK PLANS, TO THE REMAINING EXISTING SYSTEM. THE MECHANICAL-TYPE SYSTEMS WITH THE DESIGNER FOR DESIGN CONFORMANCE DURING THE SYSTEM LAYOUT SUBMITTAL REVIEW. UNLESS OTHERWISE APPROVED BY
MATERIALS OR EQUIPMENT. THE CONTRACTOR SHALL NOT ENDANGER EXISTING STRUCTURES AND ANY NEWLY CONSTRUCTED STRUCTURE BY OVERLOADING THE
AFOREMENTIONED WITH MATERIALS OR EQUIPMENT. THE CONTRACTOR SHALL PROTECT ALL EXISTING CONSTRUCTION TO REMAIN AND NEW CONSTRUCTION AFTER IT CONTRACTOR WILL REVIEW WITH THE ARCHITECTURAL DESIGNER IN THE FIELD ANY CONDITIONS THAT WILL CONFLICT WITH THIS INTENT. THE DESIGNER, THE INTENT FOR ALL TERMINATIONS TO THESE SYSTEMS IS TO OCCUR AT ROOF SURFACES, WHICH CAN NOT BE SEEN FROM THE STREET OR WITHIN A 182 Thurbers Avenue
VERTICAL ROOFTOP SURFACES, SUCH AS A PARAPET WALL OR EXTERIOR WALL CONDITION, WHICH CAN NOT BE SEEN FROM THE GROUND.
IS INSTALLED. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE TEMPORARY ENCLOSURES OR PROTECTION, AS NEEDED, TO PROTECT THE EXISTING STRUCTURE Providence, RI 02905
5. THE CONTRACTOR WILL COORDINATE THE CAPPING AND PATCHING OF THE MECHANICAL SYSTEM AND RELATED DEVICES SHOWN TO BE REMOVED WITH THE
AND ANY NEWLY CONSTRUCTED STRUCTURES FROM THE ILL EFFECTS OF WEATHER FOR THE DURATION OF THE ENTIRE CONSTRUCTION PROCESS.
EXISTING SYSTEM TO REMAIN. THE CONTRACTOR WILL VERIFY THE WORK REQUIRED FOR INSTALLING ANY NEW MECHANICAL SYSTEM AND RELATED EQUIPMENT, 4. THE CONTRACTOR WILL REVIEW ALL MECHANICAL-RELATED REQUIREMENTS OF RHODE ISLAND REGULATIONS / BUILDING CODE AND COMPLY WITH THE PROVISIONS
11.THE CONTRACTOR IS FULLY RESPONSIBLE FOR ANY DAMAGE INCURRED BY HIM OR HIS SUBCONTRACTORS TO ANY EXISTING STRUCTURE OR WORK, ANY STRUCTURE AS SHOWN ON THE NEW WORK PLANS, TO THE REMAINING EXISTING SYSTEM OR EQUIPMENT. THE CONTRACTOR WILL REVIEW WITH THE ARCHITECTURAL SPECIFIED. IF ANY CONFLICTS RESULT WITH THE DESIGN INTENT, THE CONTRACTOR WILL REVIEW SUCH SITUATIONS WITH THE DESIGNER FOR DESIGN
OR WORK IN PROGRESS; UNUSED MATERIAL INTENDED FOR USE IN THE PROJECT; OR ANY EXISTING SITE CONDITION WITHIN THE SCOPE OF WORK INTENDED BY THESE DESIGNER IN THE FIELD ANY CONDITIONS THAT WILL CONFLICT WITH THIS INTENT. CONFORMANCE BEFORE INSTALLING.
DRAWINGS AND SPECIFICATIONS. THIS RESPONSIBILITY WILL INCLUDE ANY MATERIALS AND LABOR REQUIRED TO CORRECT SUCH DAMAGE TO THE OWNER'S
SATISFACTION AT NO COST TO THE OWNER UNLESS AGREED TO BY THE OWNER IN WRITING. 6. THE CONTRACTOR WILL COORDINATE THE CAPPING AND PATCHING OF ALL EXISTING ELECTRICAL FIXTURES AND RELATED EQUIPMENT SHOWN TO BE REMOVED 5. THE CONTRACTOR WILL VERIFY AND IDENTIFY ANY REQUIRED BLOCKING IN THE FRAMING NECESSARY FOR MECHANICAL DEVICE SUPPORT OR ENCLOSURE.
WITH THE EXISTING SYSTEM TO REMAIN. THE CONTRACTOR WILL VERIFY THE WORK REQUIRED FOR INSTALLING AND CONNECTING NEW ELECTRICAL FIXTURES
12.THE CONTRACTOR SHALL WARRANTY ACCORDING TO STATE CONSTRUCTION LAW ALL WORK DONE BY HIM, HIS EMPLOYEES AND HIS SUBCONTRACTORS AGAINST ALL AND RELATED EQUIPMENT, AS SHOWN ON THE NEW WORK PLANS, TO THE REMAINING EXISTING SYSTEM. THE CONTRACTOR WILL REVIEW WITH THE 6. THE CONTRACTOR WILL PROVIDE VENTILATION DUCTS AS NECESSARY FOR THE APPLIANCES SHOWN (RANGE HOOD, CLOTHES DRYER, ETC.) AS REQUIRED BY STATE /
VISIBLE DEFECTS OR ERRORS THAT BECOME APPARENT WITHIN THE FIRST YEAR AFTER THE COMPLETION OF THE PROJECT, AS ACCEPTED BY THE OWNER. THE ARCHITECTURAL DESIGNER IN THE FIELD ANY CONDITIONS THAT WILL CONFLICT WITH THIS INTENT. LOCAL BUILDING CODE.
CONTRACTOR SHALL, ADDITIONALLY, WARRANTY ALL DEFECTS AND ERRORS NOT VISIBLE, BUT CONTAINED WITHIN CONSTRUCTED WORK, FOR A PERIOD OF TEN
7. THE CONTRACTOR WILL PROTECT EXISTING MATERIALS TO REMAIN, AS REQUIRED. DAMAGE TO EXISTING MATERIALS TO REMAIN, BECAUSE OF INADEQUATE
YEARS FROM THE COMPLETION OF THE PROJECT, ALSO ACCORDING TO STATE CONSTRUCTION LAW. ANY AND ALL DEFECTS AND ERRORS THAT DO BECOME APPARENT
PROTECTION SHALL BE FIXED, REPAIRED OR REPLACED, AS REQUIRED BY THE ARCHITECTURAL DESIGNER, AT THE SOLE EXPENSE OF THE CONTRACTOR
SHALL BE PROMPTLY REPAIRED BY THE CONTRACTOR TO THE OWNER'S SATISFACTION AT NO COST TO THE OWNER FOR MATERIALS OR LABOR. ALTERATIONS OR
INCLUDING BUT NOT NECESSARILY LIMITED TO LABOR AND MATERIALS. PLUMBING GENERAL NOTES:
CHANGES TO THIS WARRANTY MUST BE MUTUALLY AGREED TO IN WRITING BY BOTH THE CONTRACTOR AND THE OWNER.
8. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR OBTAINING ANY ADDITIONAL PERMITS, ENGINEERING, SHORING AND ANY CONSTRUCTION DOCUMENTS BY 1. THE CONTRACTOR WILL VERIFY AND IDENTIFY ALL REQUIRED BLOCKING IN THE FRAMING NECESSARY FOR PLUMBING FIXTURE SUPPORT OR ENCLOSURE.
13.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE APPROPRIATENESS OF THE APPLICATION OF ALL THE PRODUCT SELECTIONS SHOWN OR INTENDED IN
OTHERS RELATED TO THIS WORK, WHETHER OR NOT THEY ARE REQUIRED, FROM THE LOCAL AUTHORITIES.
THESE DRAWINGS AND SPECIFICATIONS. THE INTENDED MEANING OF "APPROPRIATENESS" IS THE PROPER SYSTEM, MODEL AND SPECIFIC SELECTION REQUIRED FOR
2. THE CONTRACTOR WILL VERIFY THE ROUTE AND TERMINATION AT THE ROOF FOR ALL VENT STACKS. UNLESS OTHERWISE INDICATED ON THE DRAWINGS, IT IS THE
THE INTENDED USE AS SHOWN ON THESE DRAWINGS AND SPECIFICATIONS. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THE MOST CURRENT MODEL NAME OR
9. THE CONTRACTOR IS RESPONSIBLE TO PROPERLY STORE AND PROTECT ANY MATERIAL DESIGNATED ON THE DRAWINGS TO BE SALVAGED AND RE-INSTALLED AS INTENTION OF THE DESIGNER, THAT ALL SUCH TERMINATIONS OCCUR AT LOCATIONS NOT VISIBLE FROM THE STREET.
NUMBER FROM THE SELECTED MANUFACTURER. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT ANY INSTALLERS, WHICH HE SELECTS FOR THE VARIOUS
PART OF THE NEW WORK INTENT.
PRODUCTS WILL FOLLOW ALL THAT PRODUCT MANUFACTURER'S REQUIRED AND RECOMMENDED METHODS AND PROCEDURES TO ACHIEVE THE DESIRED RESULTS
3. THE CONTRACTOR WILL REVIEW ALL PLUMBING RELATED REQUIREMENTS OF THE LOCAL BUILDING AND ENERGY CODES AND VERIFY THAT ALL NEW WORK WILL ISSUED FOR:
CLAIMED BY SUCH MANUFACTURERS FOR THEIR PRODUCTS. IN ADDITION, THESE DRAWINGS AND SPECIFICATIONS IDENTIFY SOME REQUIRED SYSTEMS AND PRODUCTS
IN GENERIC TERMS. THE CONTRACTOR IS RESPONSIBLE TO MAKE SPECIFIC SELECTIONS FOR THESE SYSTEMS AND PRODUCTS THAT SATISFY THE SAME CONDITIONS CONSTRUCTION GENERAL NOTES: COMPLY WITH ALL THE PROVISIONS REQUIRED OF THIS PROJECT. IF ANY CONFLICTS EXIST WITH THE DESIGN INTENT, THE CONTRACTOR WILL REVIEW SUCH BIDDING
SITUATIONS WITH THE DESIGNER FOR DESIGN CONFORMANCE BEFORE INSTALLING.
OUTLINED ABOUT THE IDENTIFIED MANUFACTURED ITEMS.
1. THE CONTRACTOR WILL BE RESPONSIBLE TO MAINTAIN THE SECURITY OF THE JOB SITE DURING THE CONSTRUCTION PROCESS UNTIL FINAL ACCEPTANCE BY THE
10/14/2026
OWNER OR UNTIL AN ALTERNATE DATE, AS MUTUALLY AGREED BETWEEN THE OWNER AND THE CONTRACTOR. 4. IN ALL EXPOSED CEILING AREAS, THE CONTRACTOR SHALL REVIEW WITH THE DESIGNER ANY POTENTIAL VISIBLE PLUMBING LINES, DRAINS, FIXTURE SUPPORTS,
14.IF THE CONTRACTOR FINDS FAULT WITH, DISAGREES WITH, OBJECTS TO, OR WOULD LIKE TO CHANGE THE SCOPE OF THESE GENERAL NOTES OR HIS STATED
RESPONSIBILITIES, AS OUTLINED IN THESE GENERAL NOTES, THEN THE CONTRACTOR MUST RESOLVE SUCH CHANGES WITH THE OWNER IN WRITING BEFORE SIGNING A CUTOUTS OR ANY OTHER PLUMBING RELATED WORK FOR DESIGN CONFORMANCE. THIS REVIEW WILL OCCUR IN THE FIELD PRIOR TO COMMENCING ANY WORK THAT REVISIONS:
2. THE CONTRACTOR WILL VERIFY THE ROUGH-IN DIMENSIONS AND REQUIREMENTS FROM THE APPROPRIATE MANUFACTURER OR FABRICATOR FOR DOORS, WOULD AFFECT THE VISUAL QUALITY OF THE EXPOSED CEILING AREA.
CONTRACT. FAILURE TO DO SO SHALL CONSTITUTE AN UNDERSTANDING OF THESE GENERAL NOTES AND THEIR ACCEPTANCE BY THE CONTRACTOR.
WINDOWS, EQUIPMENT, CABINETRY, PLUMBING FIXTURES, ELECTRICAL FIXTURES, APPLIANCES AND ANY OTHER DEVICES BEFORE PROCEEDING TO LAY OUT
AREAS WHERE SUCH ITEMS ARE LOCATED. 5. THE CONTRACTOR WILL VERIFY THE FOLLOWING FOR ALL HOT WATER HEATERS IN THIS PROJECT:
15.THE CONTRACTOR SHALL IDENTIFY IN HIS PROPOSAL OR BID, WHICH PERMITS HE EXPECTS TO OBTAIN AND WHICH PERMITS AND APPLICATION FEES HE EXPECTS THE
A. REQUIRED COMBUSTION AIR IS PROVIDED AS PER U.P.C. TABLE 13-1.
OWNER TO PROVIDE.
3. ALL CONNECTIONS AND FASTENERS ARE INTENDED TO BE CONCEALED, UNLESS OTHERWISE NOTED. WHERE SUCH DEVICES CAN NOT BE CONCEALED AS INTENDED B. REQUIRED ACCESS IS PROVIDED AS PER U.P.C SEC.1311.
NOTIFY THE ARCHITECTURAL DESIGNER FOR REVIEW OF DESIGN CONFORMANCE. C. REQUIRED TEMPERATURE AND PRESSURE RELIEF IS PROVIDED AS PER U.P.C. SEC. 1007(E).
16.THE CONTRACTOR IS RESPONSIBLE TO IDENTIFY ANY CONFLICTS BETWEEN HIS CONTRACT WITH THE OWNER AND THESE DRAWINGS. THE ARCHITECT, THE
D. REQUIRED SEISMIC BRACING IS PROVIDED AS PER U.P.C. SEC. 1310(E).
CONTRACTOR AND THE OWNER SHALL REVIEW THESE CONFLICTS IN ORDER TO AMEND ONE OF THESE DOCUMENTS BEFORE THE START OF THE CONSTRUCTION. IF A
4. FIREBLOCKING SHALL BE PROVIDED IN ALL LOCATIONS IDENTIFIED BY LOCAL / STATE BUILDING CODE AND IN ANY ADDITIONAL LOCATIONS IDENTIFIED BY THE E. REQUIRED INSULATION IS PROVIDED AS PER LOCAL ENERGY CODE.
CONFLICT IS DISCOVERED WITHOUT THIS PRIOR RESOLUTION, THEN THESE DRAWINGS SHALL TAKE PRECEDENCE OVER ANY OTHER DOCUMENTS IN RESOLVING A
LOCAL AUTHORITIES OR LOCAL ORDINANCES
CONFLICT. STAMP:
6. THE CONTRACTOR WILL PROVIDE NON-REMOVABLE BACK FLOW PREVENTION DEVICES AT ALL NEW HOSE BIBS.
5. THE CONTRACTOR WILL VERIFY ALL ROOF AND FRAMING SPACES REQUIRED TO BE VENTILATED WITH THE LOCAL FIELD INSPECTOR OR LOCAL CODE AND PROVIDE
17.THE CONTRACTOR SHALL ASSUME THAT SITE MEETINGS WITH THE OWNER, THE ARCHITECT AND THE CONTRACTOR PRESENT SHALL BE HELD ONCE EVERY WEEK,
THE APPROPRIATE NET FREE VENTILATION AREA, BUT IN NO CASE SHALL IT BE LESS THAN 1/50TH OF THE AREA OF THE SPACE TO BE VENTILATED. WHEN THE 7. ALL DISHWASHERS WILL BE CONNECTED DIRECTLY TO THE DRAINAGE SYSTEM WITH AN APPROVED AIR GAP FITTING.
UNLESS THEY ARE MUTUALLY CHANGED OR CANCELED. THE CONTRACTOR SHALL KEEP WRITTEN NOTES OF ALL RELEVANT INFORMATION DISCUSSED AT THESE
MEANS OF THE VENTILATION IS VISIBLE FROM A COMMONLY USED SPACE, PASSAGEWAY, YARD OR PUBLIC RIGHT OF WAY, THE CONTRACTOR SHALL REVIEW THIS
MEETINGS AND PROVIDE COPIES TO THE OWNER AND THE ARCHITECT, UNLESS DIFFERING ARRANGEMENTS ARE RESOLVED WITH THE ARCHITECT AND THE OWNER.
SITUATION WITH THE ARCHITECTURAL DESIGNER FOR DESIGN CONFORMANCE BEFORE INSTALLING SUCH DEVICES, EQUIPMENT OR MATERIALS. 8. THE CONTRACTOR WILL PROVIDE ACCESS PANELS AS NECESSARY TO SERVICE CONCEALED PLUMBING EQUIPMENT.
THE ARCHITECT SHALL PROVIDE ANY REQUESTED SKETCHES OR ANY REQUESTED INFORMATION THAT IS REQUIRED DURING THESE MEETINGS. THE OWNER AND THE
CONTRACTOR SHALL ALSO PROVIDE ANY REQUESTED INFORMATION THAT IS REQUIRED DURING THESE MEETINGS. C
RU SSELL
A R
6. THE CONTRACTOR WILL VERIFY AND PROVIDE THE REQUIRED BLOCKING AND BACKING FOR ALL CABINETRY, WALL-MOUNTED ACCESSORIES, BUILT-IN EQUIPMENT, 9. THE CONTRACTOR WILL BE RESPONSIBLE FOR COORDINATING THE WARRANTY INFORMATION AND RESPONSIBILITY WITH THE OWNER FOR ALL EQUIPMENT. IF R I M
E Y
LIGHT FIXTURES OR OTHER DEVICES REQUIRING BLOCKING OR BACKING. SPECIAL ARRANGEMENTS ARE NOT COORDINATED, THE CONTRACTOR WILL BE RESPONSIBLE FOR ALL FIXTURES AND EQUIPMENT HE INSTALLS FOR A PERIOD OF TWO
18.THE ARCHITECT OR THE OWNER CAN WRITE AND ISSUE FIELD ORDERS FOR CHANGES TO THE DRAWINGS AND SPECIFICATIONS, AS REQUESTED BY OWNER OR THE
YEARS. ANY REPAIRS REQUIRED AND PERFORMED BY THE CONTRACTOR OR HIS DESIGNATED SUBCONTRACTOR WILL BE AT NO COST TO THE OWNER, INCLUDING
CONTRACTOR. IF ADDITIONAL (OR REDUCTION OF) COST TO THE PROJECT IS REQUIRED, THEN THESE FIELD ORDERS SHALL BECOME THE BASIS OF A CHANGE ORDER.
7. THE CONTRACTOR WILL VERIFY AND PROVIDE ALL CODE REQUIRED FIREPROOFING AT ALL PENETRATIONS INTO AND THROUGH A FIRE RATED FLOOR, WALL, PARTS AND LABOR COSTS.
19.THE CONTRACTOR SHALL WRITE AND ISSUE ALL CHANGE ORDERS, WHICH SHALL INCLUDE A COST BREAKDOWN FOR ALL THE WORK DESCRIBED IN SUCH A CHANGE CEILING OR ROOF ASSEMBLY. * *
10. THE FIXTURES AND EQUIPMENT LISTED IS PROVIDED FOR THE CONTRACTOR'S BENEFIT TO COORDINATE THE INSTALLATION OF THE SAME. THE CONTRACTOR CAN
ORDER. ANY CHANGE ORDER WILL NOT BE BINDING TO THE OWNER UNTIL BOTH THE CONTRACTOR AND THE OWNER HAVE SIGNED IT.
8. ALL CHANGES OR OFFSETS IN FLOOR FINISH MATERIAL WILL OCCUR UNDER A THRESHOLD, WHEN PROVIDED, OR AT THE CENTERLINE OF A DOOR TRANSITION PROPOSE SUBSTITUTES FOR ALL FIXTURES AND EQUIPMENT LISTED, IF HE CAN DEMONSTRATE AN EQUAL QUALITY ALTERNATIVE AND IT IS APPROVED BY THE OWNER.
ARCHITECT
UNLESS OTHERWISE INDICATED ON THE DRAWINGS. OTHER LOCATIONS OF THESE CONDITIONS SHALL BE VERIFIED WITH THE ARCHITECTURAL DESIGNER IN THE
20.UPON SUBSTANTIAL COMPLETION THE CONTRACTOR SHALL NOTIFY THE ARCHITECTURAL DESIGNER, WHO SHALL COORDINATE A WALK-THROUGH OF THE PROJECT
FIELD FOR DESIGN CONFORMANCE BEFORE INSTALLING ANY MATERIAL.
WITH THE OWNER AND THE CONTRACTOR AND THEN PROVIDE A PUNCH LIST OF ITEMS TO COMPLETE. ARRANGEMENTS FOR FINAL PAYMENT WILL BE MADE AT THAT
TIME.
9. THE SEALANT, CAULKING AND FLASHING LOCATIONS SHOWN ON THESE DRAWINGS ARE NOT INTENDED TO COVER ALL CONDITIONS REQUIRING THESE PRODUCTS.
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY ALL CONDITIONS REQUIRING THESE PRODUCTS, SIMILAR PRODUCTS AND REVIEW THESE
CONDITIONS NOT IDENTIFIED IN THE DRAWINGS WITH THE ARCHITECTURAL DESIGNER FOR DESIGN CONFORMANCE.
SHEET TITLE:
GENERAL NOTES
10.COMPLETE ALL WORK REQUIRED TO MEET LOCAL / STATE ENERGY CONSERVATION REQUIREMENTS INCLUDING BUT NOT LIMITED TO ALL MANDATORY AND
SPECIAL FEATURES, AS WELL AS ANY LOCAL ORDINANCES AND ANY NEW REQUIREMENTS IDENTIFIED BY THE LOCAL BUILDING FIELD INSPECTOR.
11.THE CONTRACTOR SHALL IDENTIFY IN HIS PROPOSAL WHICH UTILITY TYPE (WATER, ELECTRICITY, TELEPHONE, INTERNET, ETC.) CONNECTIONS, USE AND
RELATED COSTS WILL BE INCLUDED IN HIS OVERHEAD AND WHICH COSTS HE EXPECTS THE OWNER TO PROVIDE. ANY UTILITY TYPE COST WHICH IS NOT
IDENTIFIED, AS AN OWNER PROVIDED ITEM, WILL BE ASSUMED TO BE INCLUDED IN THE CONTRACTOR'S OVERHEAD COST.
12.THE CONTRACTOR SHALL IDENTIFY AND PROVIDE THE REQUIRED SIDEWALK AND PUBLIC PASSAGE ENCLOSURE PROTECTION AT ANY AFFECTED RIGHT-OF-WAY
AREAS OR PUBLIC ACCESS LOCATIONS. THE CONTRACTOR WILL REVIEW ALL INTENDED SIGNAGE WITH THE ARCHITECTURAL DESIGNER FOR DESIGN
CONFORMANCE. PROJECT NORTH:
N
13.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS OF CONSTRUCTION AND ANY DIRECTION FROM THE OWNER OR THE ARCHITECTURAL
DESIGNER SHALL NOT BE CONSTRUED TO OVERRIDE THIS RESPONSIBILITY UNLESS MUTUALLY AGREED TO IN A WRITTEN DOCUMENT IDENTIFYING A SPECIFIC
AREA OF WORK FOR WHICH THE CONTRACTOR WILL NOT BE RESPONSIBLE
PROJECT ARCHITECT: BTB
DRAWN:MM
PROJECT NUMBER:
#2601
SHEET NUMBER: REV:
A0.2 ~

EXISTING-TO-REMAIN
EXIST. STG. / NOT IN SCOPE
ROOM
11 Aleppo Street
Providence RI 02909
401.400.2724
SignalWorksArchitecture.com
CONSULTANT:
NEW DENTAL LAB
1,825sf
@50net = 36.5 =
37occ.
PROJECT TITLE:
JS Dental Lab
SCOPE OF WORK SUMMARY: EXISTING
CLASSROOM
182 Thurbers Avenue
THE PROJECT CONSISTS OF DEMOLITION OF AN EXISTING 1,155sf
Providence, RI 02905
ADMINISTRATIVE OFFICE & SUPPORT SPACE TO INCORPORATE A @ 20net = 57.75 =
NEW DENTAL LAB SUITE AS THE PRIMARY EDUCATIONAL SPACE. 58occ.
AN ADJACENT, UNDERUTILIZED COMPUTER LAB SPACE w/
AVAILABLE NATURAL DAYLIGHTING WILL UTILIZED AS THE
SUPPLEMENTAL EDUCATIONAL SPACE FOR CLASSROOM-SETTING
LEARNING.
C.P.T. = 67' - 8"
THERE IS NOT SCOPE OF WORK PLANNED FOR THE CLASSROOM
SPACE AS THE FURNISHINGS AND FINISHES HAVE BEEN DEEMED
TO BE IN GOOD WORKING ORDER.
THE SCHOOL HAS STATED THAT THE DENTAL PROGRAM WILL
HAVE 20 STUDENTS IN TOTAL.
ISSUED FOR:
BIDDING
10/14/2026
REVISIONS:
STAMP:
RU SSELL
A
C R
R I M
E Y
* *
ARCHITECT
SHEET TITLE:
LIFE SAFETY/ CODE DIAGRAM
PROJECT NORTH:
N
PROJECT ARCHITECT: BTB
DRAWN:MM
PROJECT NUMBER:
#2601
1 LIFE SAFETY DIAGRAM
A0.3 1/4"=1'-0"
SHEET NUMBER: REV:
A0.3 ~
T.T.D.=
111
-
4"
CODE REVIEW SUMMARY
THE SMALL FIT-OUT OF TWO EXISTING SPACES FOR
THE SPECIFIED USE DOES NOT MAKE CHANGES TO
EGRESS COUNTS OR IMPACT THE OVERALL
OCCUPANCY OF THE BUILDING. MEANS OF EGRESS
REMAIN UNCHANGED ARE EXISTING POINTS OF
EGRESS ARE SUITABLE FOR THE INTENDED USE OF
THE SPACES.
AUTOMATIC SPRINKLER SYSTEM WILL REMAIN AND IS
BEING MODIFIED TO ACCOMMODATE THE SMALL
FIT-OUT PROJECT FOR THE DENTAL LAB.

DEMOLITION KEYNOTES
001 REMOVE & DISPOSE OF WALL(S) IN THEIR
ENTIRETY.
002 SAWCUT EXISTING CMU TO PROVIDE AN R.O. FOR
4'-0" WIDE x 3'-4" HIGH NEW WINDOW w/ SILL HEIGHT OF
48" AFF. CONTRACTOR TO PREPARE R.O. TO RECEIVE
NEW WINDOW/FRAME. CONTRACTOR RESPONSIBLE
FOR PROVIDING CLEAN & SQUARE R.O. SUITABLE FOR
FINISH-GRADE WORK.
LIMIT OF WORK
CORRIDOR
003 SAWCUT EXISTING CMU TO PROVIDE AN R.O. FOR
029A
5'-4" WIDE x 7'-0" HIGH NEW DOOR w/ SIDELITE AS
SHOWN. CONTRACTOR TO PREPARE R.O. TO RECEIVE
NEW DOOR FRAME. CONTRACTOR RESPONSIBLE FOR
PROVIDING CLEAN & SQUARE R.O. SUITABLE FOR
FINISH-GRADE WORK
BREAK ROOM
047 004 DEMO WALLS AS SHOWN UP TO 7'-8" HEIGHT TO
MATCH ADJACENT SOFFIT IN SPACE. CONTRACTOR TO
PROVIDE ALL NECESSARY WORK TO SECURE LGMF TO
STRUCTURAL DECK ABOVE, AS REQ'D TO MEET DESIGN
INTENT. CONTRACTOR TO PREPARE SOFFIT FOR
FINISH-GRADE WORK.
11 Aleppo Street
005 REMOVE & SALVAGE DOOR/FRAME AND STORE
Providence RI 02909
FOR REINSTALLATION. COORDINATE SCOPE OF WORK
401.400.2724
w/ NEW WORK PLANS
SignalWorksArchitecture.com
006 DEMO & DISPOSE OF ALL MILLWORK IN SPACE. CONSULTANT:
MAINTAIN EXISTING PLUMBING INFRASTRUCTURE.
STORAGE REFERENCE PLUMBING DRAWINGS FOR ADDITIONAL
050 RESOURCE ROOM INFORMATION. COORDINATE EXTENT OF SCOPE w/
030 NEW WORK PLANS
007 DEMO & DISPOSE ALL EXISTING FINISH FLOORING
AND RESLIENT BASE WITHIN SPACE. CONTRACTOR
RESPONSIBLE FOR PREPARING SUBSTRATE TO
RECEIVE NEW FINISH FLOORING. COORDINATE
CORRIDOR
EXTENT OF SCOPE w/ NEW WORK PLANS
028
CORRIDOR
008 MODIFY EXISTING CEILING FOR CONSTRUCTION
031C
OF NEW WALL TYPE AS SHOWN IN NEW WORK FLOOR
PLAN. CONTRACTOR RESPONSIBLE FOR PROVIDING
ALL NECESSARY, MATCHING TILES, GRID, AND
ACCESSORIES FOR A SUCCESSFUL INSTALL
PROJECT TITLE:
009 SAW-CUT & TRENCH CONCRETE FLOORING TO A
JS Dental Lab
DEPTH NECESSARY AT THE AREA SHOWN TO
ACCOMMODATE NEW WORK SCOPE FOR CONDUIT &
PIPING FOR THE FUTURE EQUIPMENT. COORDINATE
YOUTH DEVELOPMENT
FINAL PATHING w/ MEP+FP DRAWINGS.
081 182 Thurbers Avenue
TRUANCY OFFICES
Providence, RI 02905
010 CONTRACTOR TO MODIFY EXISTING
031A
SURFACE-MOUNT ELECTRICAL RACEWAY / OUTLETS TO
ACCOMMODATE THE NEW DOOR OPENING.
GENERAL DEMOLITION SCOPE NOTES
1. ALL EXISTING FRAMES AND STOREFRONTS FRAMES
ARE TO BE SANDED SUITABLE TO RECEIVE NEW FINISH
PAINT
HEARING OFFICE 2. WALL INFILLS ARE TO BE OF SIM CONSTRUCTION AS
HEARING HEARING 036 036A THE ADJACENT SURFACES. ALL SEAMS/GAPS/ETC ARE
034 035 TO BE TAPED AND MUDDED TO RECEIVE A CLASS IV
FINISH.
ISSUED FOR:
BIDDING
LEGEND
10/14/2026
= DEMO WALL / ITEM TO BE REMOVED
REVISIONS:
= EXISTING WALL TO REMAIN
= TRENCH CONCRETE FLOORING
STAMP:
RU SSELL
A
C R
R I M
E Y
* *
ARCHITECT
COMPUTER LAB
SHEET TITLE:
026
DEMO FLOOR PLAN
PROJECT NORTH:
N
PROJECT ARCHITECT: BTB
DRAWN:MM
PROJECT NUMBER:
#2601
KEYPLAN
1 DEMO FLOOR PLAN NTS SHEET NUMBER: REV:
AD1.1 ~
AD1.1 1/4"=1'-0"

RESOURC 03 E R OOM
03 0
CO RRI
030C 8'-8" (TYP)
SD
YOUTH DEVE 081 LOPME NT 8'-8" (TYP)
TRUA NCY O FFICES
031A
EX IT
HEAR 03 ING 4
STORAG E
050

GENERAL NOTES
1. DEMO PLANS ARE TO BE COORDINATED WITH NEW
WORK PLANS. ANY QUESTIONS ARE TO BE ASKED TO
THE ARCHITECT PRIOR TO PRICING EFFORTS.
2. REVIEW ANY UNFORESEEN CONDITIONS IN FIELD W/
ARCHITECT.
3. ALL CEILING FIXTURES SHOWN FOR DEMOLITION,
INCLUSIVE OF LIGHTING, GRILLES, DIFFUSERS,
SPEAKERS, ETC. ARE TO BE REMOVED, COMPONENTS
LIMIT OF WORK
MADE SAFE, AND STORED SAFELY FOR
RELOCATION/REINSTALLATION. COORDINATE EXTENT
OF WORK w/ NEW WORK RC PLAN
DEMOLITION KEYNOTES
BREAK ROOM
047 001 REMOVE & DISPOSE OF WALL(S) IN THEIR ENTIRETY.
002 SAWCUT EXISTING CMU TO PROVIDE AN R.O. FOR 4'-0"
WIDE x 3'-4" HIGH NEW WINDOW w/ SILL HEIGHT OF 48" AFF.
CONTRACTOR TO PREPARE R.O. TO RECEIVE NEW
WINDOW/FRAME. CONTRACTOR RESPONSIBLE FOR
PROVIDING CLEAN & SQUARE R.O. SUITABLE FOR
11 Aleppo Street
FINISH-GRADE WORK.
Providence RI 02909
003 SAWCUT EXISTING CMU TO PROVIDE AN R.O. FOR 5'-4" 401.400.2724
WIDE x 7'-0" HIGH NEW DOOR w/ SIDELITE AS SHOWN. SignalWorksArchitecture.com
CONTRACTOR TO PREPARE R.O. TO RECEIVE NEW DOOR
CONSULTANT:
FRAME. CONTRACTOR RESPONSIBLE FOR PROVIDING CLEAN &
SQUARE R.O. SUITABLE FOR FINISH-GRADE WORK
STORAGE
RESOURCE ROOM
050
004 DEMO WALLS AS SHOWN UP TO 7'-8" HEIGHT TO MATCH
030
ADJACENT SOFFIT IN SPACE. CONTRACTOR TO PROVIDE ALL
NECESSARY WORK TO SECURE LGMF TO STRUCTURAL DECK
ABOVE, AS REQ'D TO MEET DESIGN INTENT. CONTRACTOR TO
PREPARE SOFFIT FOR FINISH-GRADE WORK.
005 REMOVE & SALVAGE DOOR/FRAME AND STORE FOR
REINSTALLATION. COORDINATE SCOPE OF WORK w/ NEW
CORRIDOR
WORK PLANS
030C
006 DEMO & DISPOSE OF ALL MILLWORK IN SPACE. MAINTAIN
EXISTING PLUMBING LINES. REFERENCE PLUMBING
DRAWINGS FOR ADDITIONAL INFORMATION. COORDINATE
EXTENT OF SCOPE w/ NEW WORK PLANS
PROJECT TITLE:
007 DEMO & DISPOSE ALL EXISTING FINISH FLOORING AND JS Dental Lab
RESLIENT BASE WITHIN SPACE. CONTRACTOR RESPONSIBLE
FOR PREPARING SUBSTRATE TO RECEIVE NEW FINISH
SD
YOUTH DEVELOPMENT 8'-8" FLOORING. COORDINATE EXTENT OF SCOPE w/ NEW WORK
081 (TYP) PLANS 182 Thurbers Avenue
7'-8" Providence, RI 02905
008 MODIFY EXISTING CEILING FOR CONSTRUCTION OF NEW
WALL TYPE AS SHOWN IN NEW WORK FLOOR PLAN.
TRUANCY OFFICES CONTRACTOR RESPONSIBLE FOR PROVIDING ALL
031A NECESSARY, MATCHING TILES, GRID, AND ACCESSORIES FOR
A SUCCESSFUL INSTALL
EXIT
009 SAW-CUT & TRENCH CONCRETE FLOORING TO A DEPTH OF
X' - XX" AT THE AREA SHOWN TO ACCOMMODATE NEW WORK
SCOPE FOR CONDUIT & PIPING FOR THE FUTURE EQUIPMENT.
010 DEMO & DISPOSE ALL ACT GRID, TILE, AND
ACCESSORIES. SALVAGE ALL OTHER CEILING EQUIPMENT
HEARING
HEARING FOR RELOCATION. COORDINATE SCOPE w/ NEW WORK PLANS
034 HEARING OFFICE
035
036 036A
CEILING LEGEND
ISSUED FOR:
BIDDING
=GYP. BOARD CEILING
10/14/2026
REVISIONS:
=2'X2' ACOUSTICAL CEILING
TILE & GRID
STAMP:
=2'X2' DIRECT / INDIRECT
RECESSED LED BASKET FIXTURE
RU SSELL
A
C R
=SUPPLY CEILING REGISTER R I M
E Y
* *
=RETURN CEILING REGISTER
ARCHITECT
SD =SMOKE DETECTOR
COMPUTER LAB =SPRINKLER PENDANT SHEET TITLE:
026 DEMO RC PLAN
=CEILING SPEAKER PANEL
PROJECT NORTH:
N
PROJECT ARCHITECT: BTB
DRAWN:MM
PROJECT NUMBER:
#2601
KEYPLAN
1 DEMO REFLECTED CEILING PLAN NTS SHEET NUMBER: REV:
AD1.2 ~
AD1.2 1/4"=1'-0"

LIMIT OF WORK
STERILE & LAB
047
EXISTING STORAGE
050
NO SCOPE -
EXISTING TO REMAIN
MECH
030C
IMAGING
030B
DENTAL LAB
030A
002
A A 001
LATIGID
NEW WORK KEYNOTES
101 INFILL WALL w/ IN-KIND CONSTRUCTION SIM TO
WALL TYPE "A". CONTRACTOR TO PROVIDE A
LEVEL 5 FINISH AND PAINT TO MATCH ADJACENT
SURFACE
102 ALL FFE, INCLUSIVE OF MILLWORK IS TO BE
PROVIDED/INSTALLED BY AN OUTSIDE VENDOR.
SEE SUPPLEMENTAL INFORMATION PROVIDED IN
THE PROJECT MANUAL. THE CONTRACTOR IS
RESPONSIBLE FOR COORDINATING w/ OUTSIDE
VENDOR AND CARRY COSTS IN THEIR BASE BID.
103 REINSTALL SALVAGED DOOR/FRAME FROM
HEARING [034]. CONTRACTOR TO PREP DOOR &
FRAME TO RECEIVE NEW PAINT
RTF-1
11 Aleppo Street
Providence RI 02909
401.400.2724
SignalWorksArchitecture.com
FLOOR PLAN LEGEND CONSULTANT:
= NEW WALL
= EXISTING WALL
NO SCOPE -
EXISTING TO REMAIN
1A
1
STORAGE
1 PROJECT TITLE:
JS Dental Lab
003
1
182 Thurbers Avenue
1A Providence, RI 02905
004
1A
RTF-1
TR 1 TR 2 TR 3 TR 4 TR 5
1A
PROVIDE PLYWOOD 1
BLOCKING FOR WALL-HUNG ISSUED FOR:
EQUIPMENT BIDDING
10/14/2026
1B 1B A6 4 .0 REVISIONS:
A
STAMP:
RU SSELL
A
C R
R I M
E Y
* *
ARCHITECT
CLASSROOM
030 SHEET TITLE:
PROPOSED FLOOR PLAN
PROJECT NORTH:
N
PROJECT ARCHITECT: BTB
DRAWN:MM
PROJECT NUMBER:
#2601
KEYPLAN
1 NEW WORK FLOOR PLAN NTS SHEET NUMBER: REV:
A1.1 ~
A1.1 1/4"=1'-0"

EXIS NO SCOP E - EM AIN
TING TO R
MECH 030C IMAGING 030B 8'-8" (TYP)
MEC 030 H C
IM AGING 030B
030B
SD 8'-8"
SOFFIT
7'-8" (TYP)
DENTAL 030A LAB
EX
S
7'-8"
SOFFIT
7'-8"
SOFFIT
7'-8"
EXISTING STOR 050 AGE
NO S COPE
-
EXISTING TO RE MAIN

CEILING LEGEND
NEW 2'X2' ACOUSTICAL CEILING
TILE & GRID
LIMIT OF WORK
EXST 2'X2' ACOUSTICAL CEILING
TILE & GRID
STERILE & LAB
047
2'X2' DIRECT / INDIRECT
RECESSED LED BASKET FIXTURE
11 Aleppo Street
Providence RI 02909
401.400.2724
SUPPLY CEILING REGISTER
SignalWorksArchitecture.com
CONSULTANT:
RETURN CEILING REGISTER
EXISTING STORAGE
050
NO SCOPE -
NO SCOPE - EXISTING TO REMAIN SD SMOKE DETECTOR
EXISTING TO REMAIN
SPRINKLER PENDANT
MECH
CEILING SPEAKER PANEL
030C
PROJECT TITLE:
IMAGING
JS Dental Lab
030B
SD
SOFFIT 8'-8"
7'-8" (TYP) 182 Thurbers Avenue
EXST SOFFIT
Providence, RI 02905
7'-8"
DENTAL LAB
030A
EXIT
SOFFIT
7'-8"
SOFFIT
7'-8"
SOFFIT
7'-8"
ISSUED FOR:
BIDDING
10/14/2026
REVISIONS:
STAMP:
RU SSELL
A
C R
R I M
E Y
* *
ARCHITECT
CLASSROOM
030 SHEET TITLE:
REFLECTED CEILING PLAN
PROJECT NORTH:
N
PROJECT ARCHITECT: BTB
DRAWN:MM
PROJECT NUMBER:
#2601
KEYPLAN
1 REFLECTED CEILING PLAN NTS SHEET NUMBER: REV:
A1.2 ~
A1.2 1/4"=1'-0"

EYOND E BY

11 Aleppo Street
Providence RI 02909
401.400.2724
BASIS OF DESIGN: DCI HOLLOW METAL - BORROWED LITE FRAME SignalWorksArchitecture.com
CONSULTANT:
NEW 8" BOND LINTEL W/ (2) #5 BARS
CUT INTO EXISTING 8" CMU WALL -
PRIME AND PAINT AS SPECIFIED - SEE
INTERIOR FINISH SCHEDULE.
1 DOOR TYPES 2 FRAME TYPES ALIGN WITH ADJA D C O E O N R T
B.O. BOND LINTEL
A6.0 1/4"=1'-0" A6.0 1/4"=1'-0" ANCHOR PLATE BY 1
FRAME MFG.
MASONRY ANCHORS PER MFG's
REQUIREMENTS
PTD KD HOLLOW METAL INTERIOR
WINDOW FRAME. ENSURE
FRAME W BE IN Y D O O N W D G CO AP R S N . ERS ARE TIGHT AND FREE OF
1/4" SAFETY LAMINATED INTERIOR
GLAZING
1A
NOTE:
SIM CONSTRUCTION TO TYPE "1" EXCEPT PARTITIONS TO BE
7'-0" TALL w/ GWB TOP "CAP"
PROJECT TITLE:
A A A
JS Dental Lab
1B
4 DOOR AND WINDOW ELEVATION NOTE:
SIM CONSTRUCTION TO TYPE "1" EXCEPT PARTITIONS TO BE
DOUBLE A6.0 1-'1/4"=1'-0" 3'-6" TALL w/ GWB TOP "CAP"
STUDS
182 Thurbers Avenue
Providence, RI 02905
HM DOOR
HM DOOR FRAME
(CLEAR COAT) F C R O A A M T) E (CLEAR WINDOW FRAME BEYOND
ANCHOR PLATE BY
FRAME MFG.
SEALANT
EACH SIDE
1/4" SAFETY LAMINATED INTERIOR
GLAZING
WINDOW
FRAME BEYOND
ANCHOR PLATE BY
FRAME MFG.
3 DOOR DETAILS M RE A Q SO UI N R R E Y M A E N N C TS HORS PER MFG's
A6.0 1"=1'-0" PTD KD HOLLOW METAL INTERIOR
WINDOW FRAME. ENSURE
CORNERS ARE TIGHT AND FREE OF
GAPS.
1/4" SAFETY LAMINATED INTERIOR
GLAZING
EXISTING CMU WALL - PRIME AND WINDOW FRAME BEYOND
PAINT AS SPECIFIED - SEE INTERIOR PTD KD HOLLOW METAL INTERIOR
FINISH SCHEDULE. EXISTING 8" CMU WALL - PRIME WINDOW FRAME. ENSURE
AND PAINT AS SPECIFIED - SEE CORNERS ARE TIGHT AND FREE OF
INTERIOR FINISH SCHEDULE. GAPS.
MASONRY ANCHORS PER MFG's
REQUIREMENTS
6 WINDOW JAMB DETAIL ISSUED FOR:
5 WINDOW HEAD AND SILL DETAIL
A6.0 1-1/2"=1'-0" BIDDING
A6.0 1-1/2"=1'-0"
10/14/2026
REVISIONS:
STAMP:
RB-1
P-1
RU SSELL
A
C R
R I M
E Y
P-2
P-3
* *
ARCHITECT
P-4
P-5
SHEET TITLE:
DOOR & WINDOW SCHEDULE;
WALL TYPES AND DETAILS;
FINISH SCHEDULE &
ACT-1
'
SPECIFICATIONS
P-3
P-4
PROJECT NORTH:
N
RTF-1
PROJECT ARCHITECT: BTB
DRAWN:MM
PROJECT NUMBER:
#2601
SHEET NUMBER: REV:
A6.0 ~

DUCTWORK LEGEND CALL OUT AND TAG LEGEND
EQUIPMENT EQUIPMENT DESIGNATION
RECTANGULAR RETURN OR EXHAUST GRILLE (REQUIRING VV
POWER)
NUMBER
RECTANGULAR 4-WAY SUPPLY DIFFUSER
TYPICAL FOR #
REGISTERS,
MANUAL VOLUME DAMPER DESIGNATION
GRILLES &
DIFFUSERS
BALANCE TO CFM INDICATED
AIR ENTERING OPENING
CONNECT TO EXISTING
AIR LEAVING OPENING
LLIIMMIITT OOFF WWOORRKK
SSTTEERRIILLEE && LLAABB
004477
EEXXIISSTTIINNGG SSTTOORRAAGGEE
005500
IIMMAAGGIINNGG
003311AA
DDEENNTTAALL LLAABB
003300AA
RRTTFF--11
6x21 16x12 EXISTING
EXHAUST DUCT UP
TO REMAIN
12x6 16x8
12x5 18x8
16x10 20x10
5x21
10x8 10x10
10x4 10x4
7x01
5 6x6
12x5
12x5
12x5 10x4 10x4
12x5
8x21
14x8
6x21
5
x 4 1
C
O
N
T
IN
U E S
1
2 x
6
CONTINUES
4x8 4x8
4 x 8
6x21
6x21 6x21
8
16x12
CONTINUES
RELOCATE EXISTING
RELOCATE EXISTING
FCU-14 TSTAT TO SECTION
FCU-13 TSTAT TO SECTION
OF WALL TO REMAIN
OF WALL TO REMAIN
20x10 EXISTING
OUTDOOR AIR DUCT
TO REMAIN
8
E
B
E
C
E C
D
C E
E E
B
A A A
A
B B
A
A A A
A
6
EXISTING FCU-18
TSTAT TO REMAIN
F
F
F
F
F
RELOCATE EXISTING
FCU-12 TSTAT TO BE
OUTSIDE OF NEW ROOM
PARTITION
SEUNITNOC SEUNITNOC
KEYNOTES
A RELOCATE EXISTING CEILING RGD INTO NEW ACT CEILING. PROVIDE AND INSTALL
FLEX DUCT AS REQUIRED FOR RELOCATION. EXISTING DUCTWORK TO REMAIN.
11 Aleppo Street
B EXISTING FAN COIL UNIT TO REMAIN. REMOVE AND REPLACE AIR FILTERS, IF
Providence RI 02909
EQUIPPED.
C NEW CEILING TRANSFER FAN CONTROLLED BY NEW COOLING THERMOSTAT SET 401.400.2724
TO ACTIVATE WHEN ROOM TEMPERATURE RISES ABOVE 80 degreesF. TRANSFER FAN SignalWorksArchitecture.com
SHALL BE DUCTED TO THE ADJACENT SPACE BY NEW 8" ROUND ACOUSTICALLY
CONSULTANT:
LINED DUCT TO A CEILING GRILLE. FAN SHALL BE TYPICAL TO GREENHECK MODEL
SP-A510-VG, CAPABLE OF TRANSFERRING 500 CFM BUT EQUIPPED WITH A SPEED
CONTROLLER SET TO 350 CFM. FAN SHALL BE PROVIDED WITH A 115-VOLT CIRCUIT
BY THE ELECTRICAL CONTRACTOR. CEILING GRILLE SHALL BE TYPICAL TO PRICE
MODEL 635, 14x14 NECK SIZE, LAY-IN FRAME WITH WHITE FINISH. B E R
D NEW WALL TRANSFER GRILLE INSTALLED 12" ABOVE FINISHED FLOOR. TRANSFER
GRILLE SHALL BE TYPICAL TO PRICE MODEL 635, 16x16 NECK SIZE, 1-1/4" FLAT
FRAME, COUNTERSUNK SCREW FASTENING, WITH WHITE FINISH.
E EXISTING CEILING RGD TO REMAIN. ALL ASSOCIATED DUCTWORK TO REMAIN.
F PROVIDE AND INSTALL NEW CEILING EXHAUST GRILLE TYPICAL TO PRICE MODEL
635, 8x8 NECK SIZE, LAY-IN FRAME WITH WHITE FINISH. PROVIDE AND INSTALL NEW
6" ROUND BRANCH DUCT TAKE-OFF WITH VOLUME DAMPER IN EXISTING 12x6
EXHAUST DUCT TO REMAIN. PROVIDE AND INSTALL NEW 6" ROUND DUCT
THROUGH EXISTING WALL FROM NEW TAKE-OFF TO NEW CEILING GRILLE.
BALANCE EXISTING EXHAUST GRILLES FROM 295 CFM TO 245 CFM AND BALANCE
NEW STORAGE ROOM EXHAUST GRILLE TO 100 CFM.
PROJECT TITLE: G REMOVE AND CLEAN EXISTING FCU RETURN GRILLE FOR RELOCATION IN TO
ADJACENT SPACE AS INDICATED ON FLOOR PLAN. CAP AND SEAL EXISTING JS Dental Lab
OPENING IN FCU RETURN AIR DUCT. PROVIDE AND INSTALL NEW 14" ROUND FLEX
DUCT WITH HELICAL SUPPORT WIRE RATED FOR RETURN AIR APPLICATIONS FROM
RELOCATED EXISTING RETURN GRILLE BACK TO EXISTING FCU RETURN
DUCTWORK. PROVIDE AND INSTALL ALL NECESSARY TRANSITIONS FROM EXISTING 182 Thurbers Avenue
RETURN GRILLE DUCT CONNECTION SIZE TO THE 14" ROUND FLEX DUCT AND NEW Providence, RI 02905
14" ROUND CONNECTOR TO THE EXISTING FCU RETURN DUCTWORK.
ISSUED FOR:
C 100% CD SET
10/14/2026
G REVISIONS:

4 1
STAMP:
G
SHEET TITLE:
MECHANICAL PROPOSED
FLOOR PLAN - DUCTWORK
PROJECT NORTH:
N
PROJECT ARCHITECT: BTB
DRAWN:KB
PROJECT NUMBER:
1 PROPOSED FLOOR PLAN - DUCTWORK #2601
M1.1 1/4"=1'-0"
SHEET NUMBER: REV:
~
M1.1
BER JOB#: 26066

This is the opportunity summary page. It provides an overview of this opportunity and a preview of the attached documentation.
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

OEV27007095 |MPA 603 LITERACY AND DYSLEXIA ENDORSEMENT PROVIDERS The Rhode Island Department of

State Government of Rhode Island

Bid Due: 2/29/2028

Info Opening Time Solicitation Number Solicitation Status Bid Title Posting Group Posting Entity

State Government of Rhode Island

Bid Due: 2/28/2027

RFP27007072 |DOC On-Site Psychiatric Services DOC is seeking proposals from qualified vendors to

State Government of Rhode Island

Bid Due: 11/18/2026

Info Opening Time Solicitation Number Status Bid Title Posting Group Posting Entity Contact

State Government of Rhode Island

Bid Due: 11/19/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.