J041--TVHS VFD Replacement
Active
Contract Opportunity
Notice ID
36C24926Q0229
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
249-NETWORK CONTRACT OFFICE 9 (36C249)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information View Changes
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
  • Updated Published Date: Jun 04, 2026 02:26 pm CDT
  • Original Published Date: May 26, 2026 03:16 pm CDT
  • Updated Date Offers Due: Jun 16, 2026 11:00 am CDT
  • Original Date Offers Due: Jun 16, 2026 11:00 am CDT
  • Inactive Policy: Manual
  • Updated Inactive Date: Jul 16, 2026
  • Original Inactive Date: Jul 16, 2026
  • Initiative:
    • None
Classification View Changes
  • Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
  • Product Service Code: J041 - MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT
  • NAICS Code:
    • 238220 - Plumbing, Heating, and Air-Conditioning Contractors
  • Place of Performance:
    Tennessee Valley Healthcare System Medical Center Nashville , 37212
Description View Changes
The purpose of this amendment is to post Questions and Answers to Solicitation 36C24926Q0229 TVHS VFD Replacements
Questions and Answers 36C24926Q0229 VFD Replacements
Question: Is this is a brand new contract OR if there is (was) an incumbent performing these services.

Answer: This is a new contract

Question: Is there a scheduled site visit or if one can be arranged? We would appreciate any details you could provide, including the date and time, if applicable.

Answer: Site visit will be scheduled and no pictures will be provided. Email Stephen.Browne@va.gov to set up a site visit.

Question: Specification Section 5.b requires NICET Level I or NETA Level II certification. Will the Government accept licensed electricians and manufacturer-certified VFD/controls technicians as an equivalent qualification?

Answer: Because this a replacement and the systems are tied to the Fire system. You would need electricians and manufacturer-certified VFD/controls technicians as an equivalent qualification?

Question: Please confirm whether electrical one-lines, mechanical and electrical plans, existing VFD schedules, control diagrams, BAS point lists, fire alarm interface diagrams, or record/as-built drawings are available for the listed VFD locations. If available, please provide them with amendment.

Answer: Because this a replacement we can provide locations and point lists, upon request

Question: Please confirm whether photos of the existing VFDs, disconnects, bypasses, conduit entries, mounting locations, BAS/control panels, and related fan room and mechanical room conditions can be provided by amendment.

Answer: Because this a replacement we can provide locations and pictures upon request

Question: Please confirm whether the Government will schedule a pre-bid site visit or escorted field verification before the quote due date so vendors can review existing VFD locations, mounting conditions, access, conduit entries, control interfaces, and outage constraints.

Answer: Outage constraints can be worked by scheduling after contract is awarded. We can set up a pre bid site visit if needed. (See Question 2)

Question: The SOW states the facility standard is Danfoss and the technical evaluation subfactor requires Danfoss-manufactured VFDs. Please identify the required Danfoss model, series, or product line and any required options or accessories.

Answer: The Danfoss model series would be determined by the size required for the equipment

Question: The equipment list specifies a disconnect with bypass for each unit. Please clarify whether the bypass is required to be an integral VFD bypass package, a separate disconnect and bypass assembly, or another specific VA-standard configuration.

Answer: Some of the VFDs being replaced are standalone VFDs, these require build in bypass and disconnect. Others are dual systems with added cabinets with disconnects and contactors as interlocks so only one can run at a time.

Question: Please provide or clarify the required BAS point list, communication protocol, graphics requirements, trend requirements, alarm requirements, and sequence updates for each VFD.

Answer: Because this a replacement we can provide locations and point lists, upon request

Question: Please identify which listed VFDs, AHUs, fans, or pumps require fire alarm interface, shutdown, monitoring, or sequence integration. If available, please provide fire alarm drawings or sequence documentation by amendment.

Answer: Only supply and returns for AHUs and some exhaust fans
FR 3
AHU 9 Supply 1
133129
40
FR 3
AHU 9 Return 1
90770
10
FR 3
AHU 9 Return 2
98773
10
FR 1
AHU 5 Supply 1
96487
40
FR 1
AHU 5 Supply 2
96486
40
FR 17
AHU 54
No #
25
FR 17
RF 54 A
No #
5
FR 17
RF 54 b
No #
5
FR 10
AHU 33
99076
25
FR 4
AHU 22
No #
15
FR 4
RF 22
No #
7.5
FR 11
AHU 26
90743
40
F-8
RF 31
116838
7.5
FR 10
EF72
123027
1.5
FR 10
EF55
123024
2
FR 10
EF64
123023
20
FR 12
AHU 4
No #
5
FR 3
Tertiary Pump
33694
15
F-8
HWP 6
No #
5
FR 9
AHU 32
99075
30
FR 16
AHU 52 Supply
88170
40
FR 16
AHU 52 Return
88174
5
FR 16
AHU 51 Supply
88171
40
FR 16
AHU 51 Return
88175
5

Question: Please clarify whether any of the listed AHUs, return fans, exhaust fans, or pumps are part of a smoke control or other life safety sequence that requires special testing, witnessing, or documentation.

Answer: Only the AHUs

Question: Please identify any listed equipment serving critical, sensitive, or restricted hospital areas and any outage limitations beyond the general after-hours and weekend coordination requirement.

Answer: AHU 54 would have to be scheduled for after-hours

Question: Please clarify whether the Government requires witnessed functional testing for each VFD, BAS point verification, bypass testing, fire alarm interface testing, or other commissioning checkpoints.

Answer: Yes, this part of commissioning

Question: Please clarify available loading and unloading areas, freight or service elevator access if applicable, staging limitations, parking limitations, and whether work areas require special access procedures beyond standard badging.

Answer: Contractor parking is available. Contractors for this project will be escorted by VA personnel.

Question: Please confirm whether one qualified prime contractor employee may serve in multiple project roles, such as Superintendent, Site Safety and Health Officer, Quality Control Manager, and Project Manager, provided that the individual meets all applicable qualification requirements and can properly perform each required function for the project.

Answer: Provided that this person is onsite during installation.
Attachments/Links
Contact Information
Contracting Office Address
  • VISN 9 CONSOLIDATED ACQUISITION 3400 LEBANON ROAD
  • MURFREESBORO , TN 37129
  • USA
Primary Point of Contact
Secondary Point of Contact


History

Related Document

May 26, 2026[Combined Synopsis/Solicitation (Original)] J041--TVHS VFD Replacement
Jun 16, 2026[Combined Synopsis/Solicitation (Updated)] J041--TVHS VFD Replacement
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...) for free government expertise related to contract opportunities. APEX Accelerators are funded ...

DEPT OF DEFENSE

Bid Due: 6/24/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.