SP-300 Potentiostat, Potentiostat/galvanostat board and a standard cell cable with electrometer

Location: Tennessee
Posted: Apr 29, 2025
Due: May 7, 2025
Agency: ENERGY, DEPARTMENT OF
Type of Government: Federal
Category:
  • 66 - Instruments and Laboratory Equipment
Solicitation No: RFQ371738
Publication URL: To access bid details, please log in.
Follow
SP-300 Potentiostat, Potentiostat/galvanostat board and a standard cell cable with electrometer
Active
Contract Opportunity
Notice ID
RFQ371738
Related Notice
Department/Ind. Agency
ENERGY, DEPARTMENT OF
Sub-tier
ENERGY, DEPARTMENT OF
Office
ORNL UT-BATTELLE LLC-DOE CONTRACTOR
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Solicitation (Original)
  • Original Published Date: Apr 29, 2025 06:07 pm EDT
  • Original Date Offers Due: May 07, 2025 05:00 pm EDT
  • Inactive Policy: Manual
  • Original Inactive Date: May 10, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: 6630 - CHEMICAL ANALYSIS INSTRUMENTS
  • NAICS Code:
    • 334516 - Analytical Laboratory Instrument Manufacturing
  • Place of Performance:
    Oak Ridge , TN 37830
    USA
Description

SP-300 Potentiostat, Potentiostat/galvanostat board and a standard cell cable with electrometer



Request for the exact or domestic equivalent multi-channel, modular design potentiostat/galvanostat/EIS analyzer based on a portable chassis is required. Needs to be capable of USB and ethernet communication. Needs the following operational modes: floating, grounded, counter electrode to ground, working electrode to ground. EIS experiment functionality from 10 micro-Hz to 7 MHz. No separate analyzer should be required. Both sine and multi-sine techniques need to be available. Current and voltage should be possible to be measured simultaneously, with compliance voltage of +/- 12 Volt and reference voltage adjustable between -10 to +10 volts, with same range between working and reference electrodes. Resolution must be programmable from 300 micro-volts down to 1 micro-volts. Needs to apply and measure currents from 1 pico-amp to 500 milli-amps, a current control resolution of 0.004% and accuracies to 0.1% of FSR. Should be possible to be interfaced with boosters of 1,2,4 or 10 Amps on the same chassis. Multi-amp boosters should be possible to be paired for higher currents. Should be expandable to include a linear scan generator for true analog waveforms, up to 1 MV/s with data aquisition rates as fast as 1 micro-second. Requires an ultra-low current option to +/- 100 femto-amps on 1 pico-amp range with greater than 10^14 ohms input impedance. Should be capable of switching control modes in under 5 microseconds, without adverse spiking of the current in the connected cell. Requires an external input for control of potential or current via external analog input from separate device. Needs to have at least nine user-selectable bandwidths for full stability control on channels. Analog filters (50 kHz, 1 kHz, 5 Hz) as well as digital filtering in software. Needs to be able to acquire data at 20 micro-second frequency. Needs to be capable of 2-5 terminal measurements (for simultaneous WE-RE and RE-CE voltage and EIS techniques). Needs to be possible to self-calibrate. Software should be freely available and not require licenses or cloud computing. Needs to be able to interface with LabView virtual instrument software. needs to be able to load prior settings upon loading a previously-run data file. Should be able to group or synchronize channels for duplicate measurements. Software should be able to fit and simulate cyclic voltammetry curves. EIS analysis tools should include Mott-Schottky analysis. Should be able to run multiple sets of settings in a specific order utilizing a batch mode.


Attachments/Links
Contact Information
Contracting Office Address
  • Oak Ridge National Laboratory PO Box 2008
  • Oak Ridge , TN 37831
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Apr 29, 2025 06:07 pm EDTSolicitation (Original)
Daily notification on new contract opportunities

With GovernmentContracts, you can:

  • Find more opportunities and win more business
  • Receive daily alerts for all new bid opportunities
  • Get contract opportunities matched to your business
ONE WEEK FREE TRIAL

See also

...your input and participation in this process. 2. BACKGROUND: The Department of General ...

State Government of Tennessee

Bid Due: 6/15/2026

...permitting and mobile inspections for Environmental Health. We appreciate your input and participation... ...

State Government of Tennessee

Bid Due: 6/15/2026

...your input and participation in this process. 2. BACKGROUND: The Tennessee Department of ...

State Government of Tennessee

Bid Due: 6/15/2026

* Disclaimer: Information regarding bids, requests for proposals (RFPs), or requests for qualifications (RFQs) is provided on this website only for convenience and does not constitute official public notice. Persons wishing to respond to or inquire about bids, RFPs, or RFQs should contact the appropriate government department.